Tender For Reconstruction Of Garrage,Bathroom And Misc Works Of Kothi No 2Patiala
Tender Value
9.85 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
0 days left
EMD
19706
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Reconstruction Of Garrage,Bathroom And Misc Works Of Kothi No 2Patiala
BOQ
| Sl. No. | Item Description |
| 1 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. |
| 2 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth |
| 3 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 & vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 4 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works,where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 5 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 6 | 12.50 mm thick cement plaster 1:4 |
| 7 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 8 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 9 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge |
| 10 | Cement concrete 1:4:8 with brick balast 40mm gauge mixing by manual means |
| 11 | Supply and erection of G.I. pipe ‘A’ quality of suitable length and dia. confirming to IS:1239 (Part-I) 1979, including fixing up to a given depth below G/L, the hole of excavation about 30cm dia. and given depth to be filled in up to 15cm below G/L with 1:2:4 cement concrete including painting of pole with two coats of approved aluminium paint as required. - G.I. Pipe Pole 6.1 metre Long, Dia. 80mm, Planting Depth 120cm with Pit Depth 135cm. |
| 12 | Supply and erection of G.I. Pipe (AClass) Single arm bracket of suitable length to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the existing surface/ wall with 2nos. MS flat clamp 25mm x 5mm, 30cm long and 4nos. fastner 10mm x 75mm long with two coats of an approved aluminium paint complete in all respect as approved by the Engineerin-charge at site. - Single Arm Bracket 1 metre Long G.I. Pipe 40mm Dia. |
| 13 | Laying of under ground cable to be laid 1 metre below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc. |
| 14 | Making of cement concrete muff of overall size 450 mm dia., suitable length (15cm below ground level) with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole/GI pipe pole.The outer surface of the muff shall be finished with 1:2 cement plaster with two coats of white snowcem complete in all respect as approved and desired by the Engineer in-Charge at site. - Cement Concrete Muff of Overall Size450mm dia., 60cm long |
| 15 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound)confirm to IS:14772 (Recessed/ On surface),robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size &hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete inall respect as approved and desired by the Engineer In-Charge at site. - SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement. |
| 16 | Providing & fixing bajaj LED Luminaire (45 W) street light |
| 17 | Grassing of grounds with doob grass including uprooting rank vegetation and weeds by digging the area to a depth of 15 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, mixing fertilizer, rough dressing and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts, planting grass roots in rows 10 cm apart in both directions, watering, weeding and maintenance till turf is formed. |
| 18 | Planting seasonals at flowering stage in beds including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting at 20cm distance from plant to plant and row to row. |
| 19 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 20 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. - 0.50 mm (+ 0.05 %) thick |
| 21 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (with fan box) |
| 22 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring light point |
| 23 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring 6Amp. wall socket point |
| 24 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring 6Amp. Plug control comprising wall socket point |
| 25 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.0sq.mm (Un-sheathed) |
| 26 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed) |
| 27 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (Un-sheathed) |
| 28 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4sq.mm (Un-sheathed) |
| 29 | CONCEALED IN WALL: providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge24-02- 2025-Providing and fixing CPVC pipe 25mm |
| 30 | P/F brass ball walve:- Ball Valve 25mm dia |
| 31 | P/F and jointing Union Coupling in GI pipes lines:- 25mm dia |
| 32 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. |
| 33 | Providing and fixing in position vitreous china ware white lavatory suits of approved make including brasstuds without CP fittings :- size 630mmx500mm |
| 34 | Waist pipe PVC 32mm dia |
| 35 | Providing and fixing in position Chinaware Floor mounted European type one piece EWC with matching cistern with P or S trap (to the approval of the Engineer-in-charge) with seat cover complete in all respect and to the entire satisfaction of engineer in charge. b floor mounted EWCsize 69x36x74 cm |
| 36 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. |
| 37 | Providing & Fixing in postion 15 mm i/d bib cock of best quality (as approved by the Engineer-in-charge). |
| 38 | Providing & fixing in position best Indian make PVC flexible tube connection. B PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 39 | Providing and fixing in position gratings 150mm x 150mm for gully trap. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender