Tender For Repair/ Maintenance Of Servo Voltage Stabilizer And Lt Power Supply At Chnc Under Ge (U) Udh Ur.
Tender Value
47 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
19 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Servo Voltage Stabilizer And Lt Power Supply At Chnc Under Ge (U) Udh Ur.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair/ Maint of Servo voltage stabilizer and LT power supply at CHNC under GE (U) Udhampur. Contract No: GE/U-117/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Material and Labour for earthing complete with galvanized iron of street or earth plate of size 60cmx60cmx6 mm thick buried directly in ground. Vertically total depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 32x6 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer ( including making of test point with GI strip of size 32x6 mm) including GI protection pipe 40 mm light grade dia for protection of strip upto test point all as directed GI pipe medium grade 20 mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40 mm graded stone aggredates complete including excavation and earth work, all as specified and show in plate No 3 of SRR-2009 Part-1, PCC pit shall be provided at least 50cm away from the earth pit and not just on earth pit including testing on completion complete all as specified and directed by Engr-in-Charge. |
| 3 | Opening, maintenance and general servicing of servo voltage stabilizer of capacity 250 kVA incuding removal of sludge from disserstate coils, buck boost transfomers, tightening of all nuts and bolts, cleaning of stabilzer coils, checking and servicing of servo mechanisam, gear, syncronising system, automatic voltage regulator circuits and other allied electrical components complete all as specefied and directed by Engr-in-charge. Note : (a) Voltage stabilizer must be repaired by original manufacturer or by authorised service provider of the company. b) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item c) All T & P and transportaion arrangement are deemed to be included in the rates quoted. |
| 4 | Supply and fixing following parts suitable for three phase servo voltage stabilizer 250 kVA capacity as per existing make or as recommanded by original stabilizer manufacturer ie M/s Volina or equvalent complete all as specefied and directed by Engr-in-charge. |
| 5 | Servo control panel |
| 6 | Servo ciircuit card (PCB) |
| 7 | Servo control box |
| 8 | Multifunction meter |
| 9 | PCB Holder |
| 10 | Voltmeter |
| 11 | Ammeter |
| 12 | Trigger Transformer 18V |
| 13 | Push button/Auto Manual switch/Micro switch/Limiti switch/Lever switch/Potential meter |
| 14 | Indicator Light/DPDT/SPDT/SPST |
| 15 | Servo Motor with RC |
| 16 | Carbon Brush |
| 17 | Dimmer 10 to 32 Amp |
| 18 | Transformers (per phase) |
| 19 | Opening, maintenance and general servicing of servo voltage stabilizer of capacity 1250 kVA incuding removal of sludge from disserstate coils, buck boost transfomers, tightening of all nuts and bolts, cleaning of stabilzer coils, checking and servicing of servo mechanisam, gear, syncronising system, automatic voltage regulator circuits and other allied electrical components complete all as specefied and directed by Engr-in-charge. Note : (a) Voltage stabilizer must be repaired by original manufacturer or by authorised service provider of the company. b) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item c) All T & P and transportaion arrangement are deemed to be included in the rates quoted. |
| 20 | Supply only following parts suitable for three phase servo voltage stabilizer 1250 kVA capacity as per existing make or as recommanded by original stabilizer manufacturer ie M/s Electric Instrumentation only complete all as specified and directed by Engr-in-Charge. |
| 21 | Control card H-999 |
| 22 | Control card J-1195 |
| 23 | THH Transformer T-HH |
| 24 | Step Syn Motor 20kg SS-202 |
| 25 | RFP Card REP-301 |
| 26 | Pot meter 5k 1W |
| 27 | Carbon Brush |
| 28 | Tension spring |
| 29 | E-Wire 200 AMPS |
| 30 | Carbon brush holder |
| 31 | M&L for Dehydration including filtration and cleaning of Servo Voltage Stabilizer oil by dehydrating machine incl testing of sample before and after dehydration and filtration all as specified and directed by Engr-in-Charge.NOTE:- dehydration machine and testing kit will be provided by the Cont.Sample testing will be carried out in the presence of Engr-in-Charge on site. |
| 32 | Supply & Filling /pouring of up to the appropriate level Servo Voltage Stabilizer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed by Engr-in-Charge.NOTE:- Dielectric strength test shall be carried out at site before poring/filling in Servo Voltage Stabilizer in the presence of Engr-in-Charge on the site |
| 33 | M & L Preparing surfaces of Servo Voltage Stabilizercomplete body and applying painting two coats of superior quality synthetic enamel paint using spray gun including sticker work and writing of MES/SM Nos etc complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply, install and commissioning of UPS capacity 30 KVA/30 KW IGBT Rectifier & IGBT Inverter Tranformerless UPS, 3 Phase input and 3 Phase output, PWM technology, IGBT based.The power factor of UPS to be 0.99 at 100% Load(a) Inclusive of Cealed maintanance free bateries for 30 Min backup on full load.Battry min 26 AH 40 Nos (b) Angle Iron paited batteries rack(c) With and tinned copper batteries inter linked cables and thimbles(d) LCD display and built in bypass arrangement with auto change over protection incase of high and low voltages, single phasing and phase reversal protection etc.(e) Warranty :- 3 Years on UPS & 2 Years on 12V VRLA Batteries. |
| 35 | Supply, install and commissioning of UPS capacity 20 KVA/20 KW IGBT Rectifier & IGBT Inverter Tranformerless UPS, 3 Phase input and 3 Phase output, PWM technology, IGBT based.The power factor of UPS to be 0.99 at 100% Load(a) Inclusive of Cealed maintanance free bateries for 30 Min backup on full load.Battry min 26 AH 32 Nos (b) Angle Iron paited batteries rack(c) With and tinned copper batteries inter linked cables and thimbles(d) LCD display and built in bypass arrangement with auto change over protection incase of high and low voltages, single phasing and phase reversal protection etc.(e) Warranty :- 3 Years on UPS & 2 Years on 12V VRLA Batteries. |
| 36 | Supply and fixing in replacement of Air Circuit Breaker 415V Microprocessor based SR18G release of capacity 2000A 4P 50K MDO rated current at 50°C conformance to IS/IEC 60947-2 & IEC 60947-2. ACB should have High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity and Having Electromechanical operation not less than 20000. ACB Should have overload phase protection, overload Neutral, short circuit, instantaneous,earth fault & individual fault LED indication complete all as specified & Directed by Engr-in-Charge. |
| 37 | Supply and fixing in replacement of Air Circuit Breaker 415V Microprocessor based SR18G release of capacity 1600A 4P 50K MDO rated current at 50°C conformance to IS/IEC 60947-2 & IEC 60947-2. ACB should have High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity and Having Electromechanical operation not less than 20000. ACB Should have overload phase protection, overload Neutral, short circuit, instantaneous,earth fault & individual fault LED indication complete all as specified & Directed by Engr-in-Charge. |
| 38 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 500 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 39 | Supply and lay DWC ( Double wall corruated ) pipe 180 x 152 mm conforming to IS 14930/ IS 16205 for protection of LT / HTCable of size 500 sqmm including neccesory Snap-Fit cuppler required for fixing all as specified and directed by Engr-in-Charge. |
| 40 | Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge. |
| 41 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed by Engineer-in-Charge |
| 42 | Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, as specified and directed by Engr-in-Charge. |
| 43 | Supply,Erection, Testing and commissioning in replacement of Automatic Power Factor correction OEM built capacitor panel suitable for indoor application, 300 kVAR, 440 Volt, 3 Phase AC, 50 Hz, APFC Panel shall be designed and manufactured by OEM only, all components Make like MCCB, MPP Capacitors, capacitor duty contactor, Reactors, APFC Relay, wire shall be as of same OEM including encapsulated copper busbar, Pan assembly shall be used for better heat dissipation and pi cooling, outgoing MCB/MCCB must be directly mounted on the PA assembly capcitors shall be sup type with high overcurrent withstand capacity capacitors steps of (12x25kVAR) for real time compensation which makes systems Reliable and sustainable complete all as specified and directed by Engr-in-Charge. |
| 44 | Supply,Erection,Testing and commissioning in replacement of 32V/15A Automatic float cum booster charger housed in common panel/enclosure powder coated, the panel shall be rigid self supporting structure reassembled totally enclosed cubical constructed out of sheet metal of 2mm thick, the panel shall have hinged door with adequate cross ventilation on both sides as well as on the top to avoid the uniques rise of temprature. The panel shall be duly cicared with chemical finish of synthetic enameled light grey internally as well as externally, charger equipment shall employ static semi conductor full wave silicon controlled rectifier suitable for operation in conjuction withg air cooled transformer single phase 230 volts 50 cycic supply, The charger shall consist one automatic/manual float charger and boost charger. The specification of the battery cjharger shall be as under AC input range 190 to 240 V 50 Hz, including rechargeable 2 volt 100 AH tubular gel VRLA battery- 16 Nos with angle Iron paited batteries rack complete all as specified and directed by Engr-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender