Tender for Repair/ Maintenance To Lt Network System In Chibber Area And Other Locations Under Ge (U) Udh Ur.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair/ maint to LT network system in Chibber area and other locations under GE (U) Udhampur. Contract No: GE/U-113/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Dismantling of old UNSVdamage/rusted PCC pole/steel tubular poles of any size necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified, and make good the distrubed surface complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply and fixing of steel tubular swaged poles swan neck type with two coat of aluminium paint ovar a coat of red oxide zinc chrome prime in externally exposed to view portion and black bituminous painting to intenal surface and portion embeded in concrete incl making five alternative strips 30 cm wide in different colour above ground level or plinth level incl marking of MES pole No in black paint complete with cast iron base plate, final tapper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00 mtr long) andcomplete all as specified and directed by Engineer-in-Charge |
| 4 | Dismantling of overhead ACSR (Aluminium conductor steel reinforced) from existing electric pole and removing unserviceable ACSR from sitecomplete all as specified and directed by Engineer-in-Charge. |
| 5 | Dismantling of insulator of any type and size from existing poles after opening nuts, bolts and removing from site complete all as specified and directed by Engineer-in-Charge. |
| 6 | Dismantling of cross arms fixed on steel tubular poles carefully and removing from site complete all as specified and directed by Engineer-in-Charge. |
| 7 | M & L for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed by Engineer-in-Charge. |
| 8 | M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates for filling in road cuts/hard standing etc complete all as specified and directed by Engineer-in-Charge. |
| 10 | Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 mtr depth for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable bricks for re-use at site obtained during excavation complete all as specified and directed by Engineer-in-Charge. |
| 11 | All as per item No 09 here-in-before but exc. 1.50 metre depth and not exc. 3.00 metre deep. |
| 12 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers n.exc. 25 cm in soils complete all as specified and directed by Engineer-in-Charge. |
| 13 | Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 14 | M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 15 | M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 16 | M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed by Engineer-in-Charge. |
| 17 | S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and directed by Engineer-in-Charge. |
| 18 | S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and directed by Engineer-in-Charge. |
| 19 | S&F double walled corrugated (DWC) pipe of size 63 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and directed by Engineer-in-Charge. |
| 20 | S&F double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and directed by Engineer-in-Charge. |
| 21 | Taking up old serviceable/unserviceable UG cable from trench/pcc/interlocking/tiles including disconnection disconection from electrical equipment for replacement , repair and re-laying or re-routing of size including make good the distrubed surface as per existing :- (Earth work shall be measured and paid separately under appropriate items of Sch-'A')complete all as specified and directed by Engineer-in-Charge. |
| 22 | (a) 16 Sqmm 4 Core to 35 Sqmm 3.5 Core |
| 23 | (b) 50 Sqmm 3.5 Core to 95 Sqmm 3.5 Core |
| 24 | (c) 120 Sqmm 3.5 Core to 185 Sqmm 3.5 Core |
| 25 | (d) 240 Sqmm 3.5 Core to 400 Sqmm 3.5 Core |
| 26 | Supply & lay test and commissiong of LT Cable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor including cable lugs of suitable size, including necessary electrical connection of 1100 volts earthed grade cross sectional area as illustrated below Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately).complete all as specified and directed by Engineer-in-Charge. |
| 27 | (a) 16 sqmm 4 core |
| 28 | (b) 25 sqmm 3.5 core |
| 29 | (c) 35 sqmm 3.5core |
| 30 | (d ) 50 Sqmm 3.5 core |
| 31 | (e) 70 Sqmm 3.5 core |
| 32 | (f) 95 sqmm 3.5 core |
| 33 | (f) 120 sqmm 3.5 core |
| 34 | (g) 150 sqmm 3.5 core |
| 35 | (h) 185 sqmm 3.5 core |
| 36 | (j) 300 sqmm 3.5 core |
| 37 | (k) 400 sqmm 3.5 core |
| 38 | Supply and fixing or laying galvanized steel tubing medium grade (ISI) marked for protection of under ground cable of size 80 mm bore complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fixing or laying galvanized steel tubing medium grade (ISI) marked for protection of under ground cable of size 50 mm bore complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and fixing or laying galvanized steel tubing medium grade (ISI) marked for protection of under ground cable of size 40 mm bore complete all as specified and directed by Engineer-in-Charge. |
| 41 | M&L for cutting/boring the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately.complete all as specified and directed by Engineer-in-Charge. |
| 42 | Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exceeding 20 cm girth.complete all as specified and directed by Engineer-in-Charge. |
| 43 | Earthing complete with GI steel earth plate electrode 60cm x 60cmx6.3mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI iron or steel earth wire 4mm dia (8 SWG) by means of nuts, volts checks nuts and washers made of GI iron or steel earth wire protected by GI iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, pre-cast RCC over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Part-I and testing after completion.complete all as specified and directed by Engineer-in-Charge. |
| 44 | Earthing complete with galvanised steel earth plate electrode size 60 cm x 60 cm, 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth strip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC 1:3:6 type C-1(using 20 mm graded stone aggregate), pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 5 of MES Schedule Part- I and testing on completion . (Concrete pit shall be 20 cm to 30 cm away from main pit).complete all as specified and directed by Engineer-in-Charge. |
| 45 | Dismantling of existing street light fitting of any size/type complete with bracket including necessary electrical connection complete all as specified and directed by Engineer-in-Charge. |
| 46 | S & F Energy saving & environment friendly LED street light fittings made out of pressure die cast anodized alluminium housing equal or less than 60 watt including necessary electrical connection complete all as specified and direced by Engr-in-Charge. |
| 47 | Refixing of Energy saving & environment friendly LED street light fittings made out of pressure die cast anodized alluminium housing with toughned glass visor equal or less than 60 watt including necessary electrical connection complete all as specified and direced by Engr-in-Charge. |
| 48 | Supply and fixing non transparent looping SMC kiosks pole box 3 phase of size 310×210×120 mm made out of engineering plastic one piece moulding siemens gray colour with hold fast including 4 Nos aluminium strips 60 amp of requird size fixed on unbrakable insulator and one no single pole MCB 1 to 3 amp 'C' curve including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. |
| 49 | S & F rigid non metallic PVC conduit of size 25 mm dia exclusive of boxed (junction/terminal) but inclusive of all tee, bends, elbows, reucers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed by Engineer-in-Charge. |
| 50 | S & F PVC insulated and sheathed 2.5 sq mm Three core multi stranded, copper conductor cable from junction box/OH line to street light fitting or for engagement lights complete all specified & directed by Engr-in-Charge. |
| 51 | Supply and fixing in replacement GI bracket 40 mm dia 1.5 Mtr long light grade made to shape including taking down old and u/s existing fitting complete.complete all as specified and directed by Engineer-in-Charge. |
| 52 | Taking down existing U/S Lt Panel of any type and size and any condition complete including disconnection of electric connection complete from site/wall and making good the distrubed surface complete all as specified and directed by the Engr-in-Charge. |
| 53 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands. (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables(v) cable glands for incoming and out going suitable cables is including rate quated by vendover (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables,Panel to be fixed at 450mm above |
| 54 | Natural Ground Level on Brick Masonry Platform including Cement Concrete 1:2:4 (20mm graded stone aggregates) 100mm thick around the Area upto 1.50 Metre in all directions from the Panel all as ordered including Provision of Cattle Fencing with Open-able Gate (1.20 Metre to 1.50 Metre in Height) around the Area upto 1.50 Metre, complete all as specified and as directed by Engr-in-Charge. (PCC platform of suitable size in cement concrete tybe-B1 using 20mm graded stone aggregate for mounting the feeder pillar box shall deemed to be included in the quoted rate ) and to accommodate the following incoming and outgoing controls and suitable size:- Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. :- |
| 55 | INCOMING(a) ACB four pole 800 Amps, 50 KA at 415 Volts, adjustable,thermal , magnetic and triping circuit- 01 No.(b) 1600 Amps rated Alluminium bus bar suitable for 3 phase 4 wire system - 01 No.(c) Phase indicating lamp RYB neon type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils (f) Changeover Switch -250 A, 4 pole-01 Nos OUT GOING(a) MCCB four pole 400 Amps, 36 KA at 415 Volts-02 No(b) MCCB four pole 320 Amps, 25 KA at 415 Volts-03 No(c) MCCB four pole 160 Amps, 25 KA at 415 Volts-01 Nocomplete all as specified and directed by Engineer-in-Charge. |
| 56 | All as above items No - above but following capacity for INCOMING(a) MCCB four pole 630 Amps, 3 KA at 415 Volts- 01 No.(b) 1260 Amps rated alluminium bus bar suitable for 3 phase 4 wire system - 01 No.(c) Phase indicating lamp RYB neon type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils OUT GOING(a) MCCB four pole 320 Amps, 25 KA at 415 Volts-04No(b) MCCB four pole 100 Amps, 25 KA at 415 Volts-02No |
| 57 | All as above items No - above but following capacity for INCOMING(a) MCCB four pole 200 Amps, 25 KA at 415 Volts- 01 No.(b) 400 Amps rated alluminium bus bar suitable for 3 phase 4 wire system - 01 No.(c) Phase indicating lamp RYB neon type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils OUT GOING(a) MCCB four pole 100 Amps, 25 KA at 415 Volts-05No(b) MCCB four pole 63 Amps, 25 KA at 415 Volts-01 No |
| 58 | S&F out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3.15mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel should have suitable size of Alluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.2 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates. Panel to be fixed at 450mm above Natural Ground Level on Brick Masonry Platform including Cement Concrete 1:2:4 (20mm graded stone aggregates) 100mm thick around the Area upto 1.50 Metre in all directions from the Panel all as ordered including Provision of Cattle Fencing with Open-able Gate (1.20 Metre to 1.50 Metre in Height) around the Area upto 1.50 Metre, complete all as specified and as directed by Engr-in-Charge. |
| 59 | (PCC platform of suitable size in cement concrete tybe-B1 using 20mm graded stone aggregate for mounting the feeder pillar box shall deemed to be included in the quoted rate ) and to accommodate the following incoming and outgoing controls and suitable size:- Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels.Incoming (a) MCCB 400 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No,Outgoing (b) Bus bar electrolytic grade alluminium of capacity 800 Amps and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 800 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set(c) MCCB four pole 160 Amps, 25 KA at 415 Volts-04 No |
| 60 | Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands. (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables(v) cable glands for incoming and out going suitable cables is including rate quated by vendover |
| 61 | M&L for Premix ready mix road repair patching compound for instant repair manufactured with a blend bitumen, aggregates and high grade polymer to ensure immediate bonding with existing surface available in bag of 25 Kg.complete all as specified and directed by Engineer-in-Charge. |
| 62 | Supply and fix earth pit chamber board of 3.15 mm thick mild steel sheet sheet of size min 45cmx30cm fixed with 12 mm thick MS rod two nos upto 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letter min 6 cm height i.e Earth pit No . Location Earthing test value and date and other letters complete all as directed by Engr-in-Charge. |
| 63 | Supply, install, 400 amp Aluminium Bus bar not less than 75 cm in length with double door enclouser dully flush in wall/wall mounted/pole mounted/grouting on earth complete with angle iron of suitable size and size 400 mmX400 mmx 100 mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 2 mm CRCA MS sheet for cable entry and locking arrangement complete including making good the disturbed surface complete all as specified and directed. Note : The PCC and required clamp of suitble size as per IS code deemed to included in the quoted rates and nothing extra will be given to the contractor. complete all as specified and directed by Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender