Tender For Repair/Maintenance Of Perimeter Lights, Street Light, Poles, Cable And Other Connected Items In The Area Of 1 Fod, Chhiber, 151 Ta And Other Locations Under Ge (Utilities) Udh Ur.
Tender Overview
Project Description
Tender for Repair/Maintenance Of Perimeter Lights, Street Light, Poles, Cable And Other Connected Items In The Area Of 1 Fod, Chhiber, 151 Ta And Other Locations Under Ge (Utilities) Udh Ur.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Oct-2026 | BOQ REVISED | BOQ | 10-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair/Maintenance of perimeter lights, street light, poles, cable and other connected items in the area of 1 FOD, chhiber, 151 TA and other locations under GE (Utilities) Udhampur. Contract No: GE/U-112/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion including earth pit chamber board of 3.15 mm thick mild steel sheet sheet of size min 45cmx30cm fixed with 12 mm thick MS rod two nos upto 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letter min 6 cm height i.e Earth pit No . Location Earthing test value and date and other letters complete all as directed by Engr-in-Charge. |
| 3 | Earthing complete with GI steel earth plate electrode 60cm x 60cmx6.3mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI iron or steel earth wire 4mm dia (8 SWG) by means of nuts, volts checks nuts and washers made of GI iron or steel earth wire protected by GI iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, pre-cast RCC over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Part-I and testing after completion. |
| 4 | Taking down unserviceable street/Security light fittings of any capacity, type , make and position (such as CFL light fitting, HPSV/MH/LED and from any tye and any height of pole etc) for repairing the same after complete dismantling, checking replacement of unserviceable parts and components as required and make the light fittings operational to give rated illumination incl cleaning the acrylic cover and refixing the same with necessary electrical connection complete all as specified and directed. (The U/S street light fittings should be removed from site and to be stored at one place for repairing purpose. The Nos of U/S light fittings to be removed, the place of repairing and refixing schedule will be as per direction and specified by Engr-in-Charge.) Note :- (Spare parts/components shall be measured and paid separately) under respective item Sch 'A'). |
| 5 | S&F in replacement of driver for LED light fitting of capacity 60W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engr-in-Charge. |
| 6 | S&F in replacement of driver for LED light fitting of capacity 60W to 90W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge.as per existing make and model complete all as specified and directed by Engr-in-Charge. |
| 7 | S&F in replacement of driver for LED light fitting of capacity 120W to 150W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engr-in-Charge. |
| 8 | S&F in replacement of driver for LED light fitting of capacity 210W to 300W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engr-in-Charge. |
| 9 | S&F in replacement of driver for LED light fitting of capacity 40 to 45W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engr-in-Charge. |
| 10 | S&F in replacement of panel for LED light fitting of capacity 60W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. Make : as per existing make and model complete all as specified and directed. |
| 11 | S&F in replacement of panel for LED light fitting of capacity 60W to 90W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engr-in-Charge. |
| 12 | S&F in replacement of Panel for LED light fitting of capacity 120W to 150W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and modelcomplete all as specified and directed by Engr-in-Charge. |
| 13 | S&F in replacement of panel for LED light fitting of capacity 210W to 300W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed complete all as specified and directed by Engr-in-Charge. |
| 14 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cables, foundation of poles, stays and getting out in any type of soil complete all specified & directed by Engr-in-Charge. |
| 15 | Excavation in trenches exc. 1.50 metre depth and not exc. 3.00 metre deep.for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable bricks for re-use at site obtained during excavation complete all as specified and directed by Engr-in-Charge. |
| 16 | Returning , filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all specified & directed by Engr-in-Charge. |
| 17 | Removing of excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified & directed by Engr-in-Charge. |
| 18 | Scrapping , cleaning and preparation of old surfaces of steel tubular pole/PCC of any type. size , height, swan neck type (9 mtr long) steel fitting including brackets, clamps, nuts bolts, washer etc complete and M&L for painting with two coat for aluminium paint after preparation of the steel surfaces and as directed by the Engr-in-Charge. |
| 19 | Mateial and labour for applied strap with two coats black and white paint in strap alternatevely all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30 cm and number of strap shall be 05 Nos complete all as specified and as directed by Engr-in-Charge. |
| 20 | Material and labour for writing pole No with sub stn No on pole with applied two coat of black paint and writing the pole No and Sub Stn No with white luminaire paint of letter size 75 mm complete and all as specified and directed by Engr-in-Charge. |
| 21 | Supply and fixing in replacement MS clamp any shape and size along with nuts, bolts and washers etc of sizes as required complete all as specified and directed by Engr-in-Charge. |
| 22 | Terminal box made out of SMC with hinged door and locking arrangements of size 140x140x95mm (in repair) including Backlite 4 way connector,M.S. Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer ,electrical connections including MCB SP 6-32 Amps complete all as specified and as directed by Engr-in-Charge. Make - Sintex product code No GSJB-1414 or or equivalent from the list of make given in particular sepecifivation |
| 23 | Supply and fixing non transparent looping SMC pole box 3 phase of size 310×210×120 mm made out of 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete with hold fast including 4 Nos aluminium busbar not less 150 cm and caacity 60 amp of requird size fixed on unbrakable insulator and one no single pole MCB 1 to 3 amp 'C' curve including taking out of old unserviceable one,complete all as specified and directed by Engr-in-Charge. |
| 24 | Replacement of old unserviceable rusted GI tubing brackets, 40mm bore, light grade with new GI tubing bracket, 40mm bore, light grade, 1.20 metre length ,made to shape including MS clamp with nuts, bolts and washers etc complete all as specified & directed by Engr-in-Charge. |
| 25 | Taking out UNSV two core/three core aluminium / copper cable of any sizes/ capacity complete all specified & directed by Engr-in-Charge. |
| 26 | S & F PVC insulated and sheathed 2.5 sq mm Three core multi stranded, copper conductor cable from junction box/OH line to street light fitting or for engagement lights complete all specified & directed by Engr-in-Charge. |
| 27 | S & F PVC insulated and sheathed 1.5 sqmm, three core, multi stranded, copper conductor cable from junction box/OH line to street light fitting or for engagement lights complete all specified & directed by Engr-in-Charge. |
| 28 | PVC insulated multi stranded aluminum conductor PVC cable sheathed 10 Sqmm twin core (in replacement) and making connections of street light fittings with overhead lines/UG Cable complete all as specified & directed by Engr-in-Charge. |
| 29 | PVC insulated multi stranded aluminum conductor PVC cable sheathed 6 Sqmm twin core (in replacement) and making connections of street light fittings with overhead lines/UG Cable complete all as specified & directed by Engr-in-Charge. |
| 30 | PVC insulated multi stranded aluminum conductor PVC cable sheathed 4 Sqmm twin core (in replacement) and making connections of street light fittings with overhead lines/UG Cable complete all as specified & directed by Engr-in-Charge. |
| 31 | Taking out UNSV XLPE UG cable of any sizes/ capacity including disconnection of all electrical connection and make good the distrubed surface complete all specified & directed by Engr-in-Charge. |
| 32 | XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 35 sqmm, 3.5 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge. |
| 33 | XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 25 sqmm, 4 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge. |
| 34 | XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 16 sqmm, 4 core, laid in trenches/ducts/through pipe complete all as specified and directed. |
| 35 | XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 16 sqmm, 2 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge. |
| 36 | XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 10 sqmm, 2 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge. |
| 37 | Double walled corrugated pipe (DWC) of size 50 mm conforming to IS:14930(part-II)/IS 16205 Part II with necessary snap fit coupler complete all as specified & directed by Engr-in-Charge. |
| 38 | S & F LED Highbay light with lens , 150 watt, 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge.Make:- Bajaj Cat No OPTIBAY150W WHNBPCSD or equvallent from the list of make given in particular specification. |
| 39 | S & F LED flood light, 150 watt, with lens , 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge.Make- Bajaj Cat No Glean-gf180LWH NB-A5PCSD or equvallent from the list of make given in particular specification. |
| 40 | S & F LED flood light, 250 watt, with lens , 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge.Make- Bajaj Cat No Glean-GLEAM F 220L WH SY PC SD V2 or equvallent from the list of make given in particular specification. |
| 41 | S&F Multi Colour (Red, green, orange ) LED flood light, 150 watt, with lens , 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge. |
| 42 | S & F LED flood light, 120 watt, with lens 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge.Make :- Bajaj Cat No PRAZEF144LWHNB-A5TGSDMT or equivalent from the list of make given in particular sepecifivationNote: For item Serial no 16.00 to 27.00(a) MS clamp,Brackets required for fixing of fitting are inclusive of rate quoted.(b) Necessary grouting/making good on existing surfaces in inclusive of rate quoted.(c) GI pipe of required dimensions if required at site shall be provided by the contractor. |
| 43 | S & F LED flood light,50 wat, with lens 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge.Make :-Bajaj Cat No GLATT MT60L WH POPCSD or equivalent from the list of make given in particular sepecifivationNote: For item Serial no16.00 to 27.00(a) MS clamp,Brackets required for fixing of fitting are inclusive of rate quoted.(b) Necessary grouting/making good on existing surfaces in inclusive of rate quoted.(c) GI pipe of required dimensions if required at site shall be provided by the contractor. |
| 44 | S&F LED street light fitting withlens , 90 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge.Note :- Necessary fixing authority including reducers may be included in rateMake- Bajaj Cat No BAJAJ' VISTA 90 WAtt or equivalent from the list of make given in particular sepecifivation |
| 45 | LED street light fitting with lens 70/72 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. Note :- Necessary fixing authority including reducers may be included in rateMake :-Bajaj Cat No BAJAJ' VISTA 70/72 WAtt or equivalent from the list of make given in particular sepecifivation |
| 46 | LED street light fitting with lens , 60 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. Note :- Necessary fixing authority including reducers may be included in rateMake:- Bajaj Cat No BAJAJ' VISTA 60 WAtt or equivalent from the list of make given in particular sepecifivation |
| 47 | S & F appointment light LED 10 watts complete all as specified and directed by Engr-in-Charge. |
| 48 | Post top lantern, LED Warm white , type 40 watt , 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection complete all as specified and directed by Engr-in-Charge.Make:- Bajaj Cat No BGCTNP 40W LED WW or equivalent from the list of make given in particular sepecifivation |
| 49 | LED bollard Warm white lights of 9/11 watt capacity including taking down existing unserviceable garden lights of any type/capacity complete all as specified and directed by Engr-in-Charge. Make: Bajaj Cat No BGBOM 605 9W LED WW or equivalent from the list of make given in particular sepecifivation |
| 50 | S&F in replacement of automatic street light control switch of 8 KW three phase using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitabe rating power contractor (s), one Incoming and three Outgoing MCBs rating of 20-32 Amps & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection class-2 (Hansel make). The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed. Model No SWADEEP 66- 8 KW3P or L&T or equivalent from the list of make given in particular sepecifivation |
| 51 | S&F in replacement of automatic street light control switch of 3 KW single phase(20 Amp per phase) having protection IP-66 using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitable rating power contractor (s), one Incoming and three Outgoing MCBs rating of 20 Amps & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection . The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed by Engr-in-Charge.Make - Navdeep with smart timer Model no -Navdeep-66-3kw 1P. or equivalent from the list of make given in particular sepecifivation |
| 52 | polycarbonate globe with gallery 300mm dia round suitable for retrofit LED lamp B22 Base (in replacement) complete all as specified & directed by Engr-in-Charge. |
| 53 | LED lamp warm white/white 11 Watt (in replacement) complete all as specified & directed by Engr-in-Charge. |
| 54 | LED lamp warm white/white 9 Watt (in replacement) complete all asspecified & directed by Engr-in-Charge. |
| 55 | Supply and fixing in replacement 63 amps TPN MCB, complete all as specified and directed by Engr-in-Charge. |
| 56 | Supply and fixing in replacement 40 amps SPN MCB, complete all as specified and directed by Engr-in-Charge. |
| 57 | Supply and fixing SPN, DBs for lexic MCB complete with SPN MCB 40 Amp, 10 KA, 240 V fixing on pole with necessary clamp and nut, bolts and as directed by Engr-in-Charge. |
| 58 | Supply and fixing MCB SP 10 to 32 amps, complete all as specified and directed by Engr-in-Charge. |
| 59 | Supply and fixing in replacement 40 amps TP power contactor, complete all as specified and directed by Engr-in-Charge. |
| 60 | Supply of exterior rated BIS registered decorative LED Post Top luminaires. Luminaire should have system wattage of 72W (+/-5%), with system lumen output of minimum 8100 lumen with all LED ON, system efficacy of 110lms/w or more and operating voltage of 100-277V AC. Offered with color temperature (CCT) of 3000K with CRI > 80 and dedicated optics for each LED (PC lens) to ensure better uniformity of light distribution. Fixture should have step layered top enclosure in spun Aluminium minimum thickness of 1.2 mm designed to suit urban landscape and Lower spun aluminium of minimum thickness of 1.5 mm with Diameter not exceeding 570 mm, should be UV protected pure polyester powder coated grey after phosphochromate treatment. It should be Pressure Die Casting heat sink for heat dissipation and clear polycarbonate cover offering IK09 (Impact Resistance) with good transmission factor, and LED lifetime of L70B50 @ 50000 hours at 50°C, LED make should be of ceramic base of Nichea, Osram, Cree, Lumiled only. The light fixture should have Operating temperature of 50 °C. Product is offered with IP 66 protection for serviceable LED Compartment and IP66 protection for Control Gear compartment with tool free access. Fixture should have diameter of 560 mm and height not more than 450 mm, weighing about 8.5kg with tolerance (+/- 5%). It should have built-in potted electronic LED driver with APFC, (SMPS based constant current supply), PF > 0.95, THD < 10%, Open Circuit Protection, over Voltage protection, Surge Voltage built in 4kV and External Surge protection up-to 10kV (DM/CM) & other safety test as per IS 15885 Part-2/Sec 13. Suitable for pole arm mounting with ID of Ø41mm with 3 nos. SS Hex bolt M8X25 screws. Make Havells Cat No EROSPT72WLED730PSYMTOPC or approved make of particular specification. |
| 61 | S &F LED Tiranga Rop light 18 Mtr,IP 65,Input Power 10W/meter,Input Voltage 220-240 VAC Input frequency 50 Hzs,Input current 0.045 Amp/Mtr,Power factor 0.95,Width of strip(+/- 0.1 mm) 8 mm length/reel-18 mtrs,No of led per mtr 120 LED,LED Beam angle 120 degree ,Rope light per Colours length 6 mtr orange, 6 mtr white ,6 mtr Green,Fixing method silicone clip ,Ingrass Protection -IP -65, Ingrass protection method silicone tube ,silicone tube dimention 11.5x5.5 mm+/- 0.5 mm,working temp range-20 degree celcius to + 45 degree celcious ,working humidity range 10-90 RH and all as directed by engineer in charge . |
| 62 | Dismantling of unserviceable concerete/steel tubular pole any size upto 9 mtr long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed by Engr-in-Charge. |
| 63 | Supply and erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws. Poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-37, 9 mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height of 1.5 m and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engineer-in-Charge. Note: - Excavation, Earth Work and PCC in foundation shall be measured and paid for separately. |
| 64 | M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 65 | M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed by Engr-in-Charge. |
| 66 | S & F GI tubing medium grade of size 40 mm dia in protection of cable of difference dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc complete all as specified and directed by Engr-in-Charge. |
| 67 | S & F GI tubing medium grade of size 50 mm dia in protection of cable of difference dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc complete all as specified and directed by Engr-in-Charge. |
| 68 | Supply and fixing street light bracket made out of 40 mm light grade GI tubing minimum 1.5 Mtr long with with suitable adapter to suit the opening of street light on one end alongwith integrated fabricated adapter round cup type with 02 Nos studs on outer side to fix the braket on top of existing steel tubular pole two way, with necessary MS clamps with one coat of red oxide and two coats of alluminium paint upon fabricated adapter including nut, bolts, washers complete all as specified and directed by Engr-in-Charge. |
| 69 | S&F of Steel tubular swaged Ring suitable for 12 m long pole for semi highmast light and for fixing of four nos flood loghts with bolts, nuts and screws, ring made out of ERW MS tubing conforming to IS-2713 including drilling of holes of required size for fixing of brackets , painting the exposed surfaces of ring with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of silver paint on the surface complete all as specified and directed by Engr-in-Charge. |
| 70 | Attending day to day complain of street light/perimeter ligts, high mast lights, flood lights, gate lighrs, garden lights, post of lantern lights, ornamental lights, decorative lights of any type, size, make, model, capacity and any condition from any height of steel tubular pole, mini high mast pole, High mast pole, buildings including disconnection of electrical connection from timer panel, MCB, and street light pole for checking the loose connecton and decarbanising between coper and alluminium conductor and reconnection of the same after checking the servicibility of electric supplly from Timer Panel to Juncion box, pole and upto LED lights fittings of any type complete with PVC tape, proper insulation and tide the wire on pole . Note : The contractor has to attend minimum 5 to 10 complain of no lights in street lights connection due to carbon, loose connection, disconnection of cable due to monkey nuisance, heavy wind flow and rain effects on electrical circuit. To attend 5 to 10 complain daily . Note : (i) Contractor should organise his staff strength in such a manner that One electrican and Two Helper shall be provided with sutable vehicle by the contractor for attending street light electrical connection unserviceability complaints at different location in the AOR of AGE E/S and all as directed . All the precautionary equipment like safety belt, earth road, hand gloves, ladder, and T&P shall be provided by the contractor. (ii) If he fails to attend the complain daily the penalty of Rs. 2000 per complain per day will be charged and deducted from the next due RAR. |
| 71 | Repairs to street light SMC box including cutting of damage cable end and refixing of cable end to busbar after repairing with complete insulation, lugs, nut bolts of suitable size and cable gland including fixing arrangement with nut bolts and clamps complete all as specified and directed by Engr-in-Charge. |
| 72 | S &F Joy LED Strings light 10 Mtr,21D IP 44, Input Voltage 220-240 VAC Input frequency 50 Hzs,Input current 0.045 Amp/Mtr,Power factor ss Protection -IP -44, ,working temp range-20 degree celcius to + 45 degree celcious ,working humidity range 10-90 RH and all as directed by engineer in charge .Make :- Havells Cat No LHEHCJP1UN4K010 or equivalent from the list of make given in particular sepecifivation |
| 73 | Supply and fixing PVC insulation tape red,yellow, blue colour 25 mm 25 mtr length tape Roll Lall as specified and directed by Engr-in-Charge. |
| 74 | Labour only for cutting/pruning the overhanging or adjacent branches of trees of any girth HT/LT overhead line including cutting the bamboos, removing the shrub from poles and cleaning the jungle below and upto 3.00 metre clear distance from the middle conductor of the line on either Side complete and removing rubbishes from Site all as directed.Note : (1) pole to pole distance from 40 to 60 mtrs will be measured as one span. (2) All the precautionary equipment like safety belt, earth road, hand gloves, ladder, and T&P shall be provided by the contractor. (3) The tree pruning will be start within 15 days of commencement of works, If he fails to attend the tree prunning complain the penalty of Rs. 2000 per span will be charged and deducted from the next due RAR. |
| 75 | Supply and fixing of stainless steel reducer complete with nut and bolts of size 50 to 40mm to 40 to 32 mm as directed of length 15 to 20 cm as per site requirement and mounting/fixing on any type and size of steel tubular pole of any height for fixing of street light complete with necessary electrical connection complete all as specified and directed by Engr-in-Charge. |
| 76 | S&F single colour warm white LED flexible strip light of 25mtr length with driver, IP20 complete with accessories including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge. |
| 77 | S&F single colour warm white LED flexible strip light of 50mtr length with driver, IP20 complete with accessories including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge. |
| 78 | Supply and Fixing of modular switches 1 way, 16 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 79 | Supply and Fixing modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed by Engr-in-Charge. |
| 80 | S&F GI Modular gang sunk-in pressed terminal boxes of size 3/4 module not less than 1.2 mm thick factory made for following module complete all specified and directed. Note: Flushing of module box in wall with cement and repairing the wall as before is deemed to be included in quoted rate.Metal flush box 3/4 module complete all as specified and directed by Engr-in-Charge. |
| 81 | S&F white cover plate with frame 4 module with frame of following module complete all as specified and directed by Engr-in-Charge. |
| 82 | S&F submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ AC plug points/Power points complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 83 | M & L for welding of steet light bracket on swan neck steel tubullar pole including fixing of MS pipe of size 40mm dia, 20 cm in length duly painnted on the neck of pole for fixing of street light fitting and providing 80 to 100 mm base plate on the edge of pole complete with necessary nuts and bolts, providing hole in the pipe including replacement of old complete all as specified and directed by Engr-in-Charge.Note : The cost of necesary T&P eqipment, like ladder, hydra, crane and welding machine work are deemed to be includeed in the quoted rates. |
| 84 | Taking down unserviceable LT panel of any size and any capacity including disconnection of all electrical connection complete all as specified and make good the distrubed surface to the exist complete all as specified and directed by Engr-in-Charge. |
| 85 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. |
| 86 | Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands. (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables(v) cable glands for incoming and out going suitable cables is including rate quated by vendover (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables, Panel to be fixed at 450mm above Natural Ground Level on Brick Masonry Platform including Cement Concrete 1:2:4 (20mm graded stone aggregates) 100mm thick around the Area upto 1.50 Metre in all directions from the Panel all as ordered including Provision of Cattle Fencing with Open-able Gate (1.20 Metre to 1.50 Metre in Height) around the Area upto 1.50 Metre, complete all as specified and as directed by Engr-in-Charge. (PCC platform of suitable size in cement concrete tybe-B1 using 20mm graded stone aggregate for mounting the feeder pillar box shall deemed to be included in the quoted rate ) and to accommodate the following incoming and outgoing controls and suitable size:- Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. :- |
| 87 | INCOMING(a) MCCB four pole 160 Amps, 25 KA at 415 Volts- 01 No.(b) 250 Amps rated copper bus bar suitable for 3 phase 4 wire system - 01 No.(c) Phase indicating lamp RYB neon type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils OUT GOING :(a) MCCB four pole 100 Amps, 25 KA at 415 Volts-04No |
| 88 | All as above items No - 84 above but following capacity for INCOMING(a) MCCB four pole 200 Amps, 36 KA at 415 Volts- 01 No.(b) 300 Amps rated copper bus bar suitable for 3 phase 4 wire system - 01 No.(c) Phase indicating lamp RYB neon type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils(f) Changeover Switch -200 A, 4 pole-01 Nos OUT GOING(a) MCCB four pole 160 Amps, 25 KA at 415 Volts-02 No(b) MCCB four pole 125 Amps, 25 KA at 415 Volts-01 No |
| 89 | All as above items No - 84 above but following capacity for Incoming(a) MCCB 160 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No.(b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 240 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set.Outgoing (a) MCCB 125 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25 KA-01 No.(b) MCCB 63 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25 KA-03 No, Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level.(iii) Outgoing MCCBs shall be fed with solid busbar connectors.(iv) Cables shall be terminated using gun metal /SS glands.(v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables.(vi) cable glands for incoming LT cable 95 sqmm -01 Nos and out going cables 70 sqmm -02 Nos and 50 sqmm - 01 Nos and 25 sqmm -04 Nos is including rate quated by vendover. |
| 90 | All as above items No -84 above but following capacity for Incoming:-(a) MCCB 160 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No,Outgoing:-(a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 240 Amp,4 pole, not less than 75 cm long mounted on insulators 01 setNote- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level(iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands.(vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables(v) cable glands for incoming and out going suitable cables is including rate quated by vendover |
| 91 | Supply and fixing of single overhang circular decorative arms of 1 mtr length one side, suitable to be mounted on Pole of 4 mtr - 9 mtr height. The Decorative arm should be made out of M.S. round tubular Pipe sections of 48mm Diameter attached to a pipe of 76mm dia to support suspended mounting of the LED Drop Down Post Top. The circular arm should be properly welded to the pipe by means of 3 segments of 29mm diameter (as shown in the reference drawing). A decorative Cast Iron embellishment knob at the top and designer element with 10mm square rod on the arm for aesthetics addition is required. The whole arm should be painted in pure polyester Paint in approved color shade of Pole. The Decorative arm to be approved by Engineer in Charge & Architect. Orbit Plus S Round Arm for Poleor equivallent of bajaj/philips/Crompton/Hallonix |
| 92 | Supply of 5-Meter-high Pole (lower section - 0.6 mtr, remaining M.S Pipe -4.4 mtr), having lower section OD 140 mm and top section 76mm diameter and Made out of GI pipe as per IS 1239. Round Mild steel plate of dimension 290 mm dia X 12 mm thick, should be joined with the pole at the bottom through welded joints, with 4 no. circular holes of dia 20mm at PCD 225mm suitable for M12 bolts. The pole must have an ornamental decorative casting at Bottom (Casting height 175mm/ lower dia 325mm) and middle casting (height 256mm and dia 2.7mm) with floral design patterns as shown in drawing. The two casting rings in the middle section (casting height 25mm/ Outer dia 116mm) as show in the reference drawing. The pole shall have window cutting of 300 mm x 100 mm weatherproof flush door & locking arrangement for housing of the pole to accommodate electrical accessories (Bakelite plate and connector) for power supply connection. The window cover is fitted with allen screws to the pole and is to be provided in bottom section of pole. The body of the pole shall be machined and polished properly to give it a smooth surface as per IS 2629 and IS2633. The pole shall have decorative casting at the top of the shaft. The decorative pole shall be duly pre-treated and painted UV resistant coating in approved color shade. The Pole & the cast iron embellishments should be machined & polished properly to get the smooth finish. The coating should have a DFT of 80-90microns. Entire unit shall be given an extensive three Stage treatment with PU based etch primer, Zinc phosphate primer and Poly Urethane paint of approved color & prescribed for such surfaces to make it absolutely rust and corrosion proof, as well as giving it a pleasing appearance. Make Havells Cat No EROSPOLET01035M or equivallent approved make from particular specification. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender