Tender For Periodical Services In Md Accn/ Otm Accn And Welcome Maintenance Of Offrs Md Accn And Internal Electrifiation At Ebs Babugarh Under Age B/R-Ii Of Ge (North) Meerut Cantt
Tender Overview
Project Description
Tender for Periodical Services In Md Accn/ Otm Accn And Welcome Maintenance Of Offrs Md Accn And Internal Electrifiation At Ebs Babugarh Under Age B/R-Ii Of Ge (North) Meerut Cantt
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-Nov-2026 |
| 2 | 17-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc.all as specified & directed |
| 2 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks complete all as specified and directed |
| 4 | Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises,removing the demolished material out of MOD land complete all as specified. |
| 5 | Demolition cement concrete (unreinforced) in ground floors and paving n exc 15 cm thick and removing the demolished material out of MOD land complete all as specified. |
| 6 | M&L Non skid ceramic coloured tiles 7-8mm thick (Square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm in floors set and jointed in neat cement slurry and pointed with white or colour cemnt to match including 15 mm th screed ded in cm 1:6 all as specified and directed |
| 7 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) 25 mm thick for Sub base flooring all as specified |
| 8 | S&F non skid coloured ceramic tiles coloured of 7 to 8 mm (square/ rectangular ) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors set and jointed in neat cement slurry and pointed with white or coloured cement over 15mm screed bed in CM 1:6 complete all as specified and directed. |
| 9 | All as per item No 7.00 above but as in skirting over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 10 | S&F Coloured Glazed colour ceramic tiles in vertical surfaces 300x 600x7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM(1:4) joint free with grout of matching shade complete, all as specified |
| 11 | M&L for vitrified ceramic tiles light shade 10 mm thick (square/rectangular) area of each tiles not exceeding 0.36 sqm, in floors etc, with neat cement slurry over and including 15 mm thick screed bed of cement mortar 1:6 including pointing in white or coloured cement with pigment to match the shade of tiles complete all as specified and directed. |
| 12 | All as per item Srl item No 11 here-in-before but on vertical surfaces such as skirting fixed on and including 10mm thick rendering in cement mortar 1:4 as backing coat complete all as specified and directed. |
| 13 | M&L for vitrified ceramic tiles light shade 10 mm thick (square/rectangular) area of each tiles exceeding 0.42 sqm but not exc 1.00 Sqm, in floors etc, with neat cement slurry over and including 15 mm thick screed bed of cement mortar 1:6 including pointing in white or coloured cement with pigment to match the shade of tiles complete all as specified and directed. |
| 14 | All as per item Srl item No 14 here-in-before but on vertical surfaces such as skirting fixed on and including 10mm thick rendering in cement mortar 1:4 as backing coat complete all as specified and directed. |
| 15 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons laid and pointed in any mortar etc complete all as specified and directed. |
| 16 | M&L for Makrana white marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms, floors and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade all as specified and directed |
| 17 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite and including 15mm thick screed bed or backing coat in cement mortar (1:6) and jointed with grey cement slurry and pointed with white cement and with admixture or pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed. |
| 18 | Providing edge moulding to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete. |
| 19 | M&L for kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match thick shade of the slab including rubbing and polishing laid over 15mm thick screed bed in cm (1:6) complete all as spd. |
| 20 | All as per item No 20 above here-in-before but on vertical surfaces of walls /skirting/dado etc complete all as spd. |
| 21 | M & L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete. complete all as specified and directed. |
| 22 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each. complete all as specified and directed |
| 23 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqm each. complete all as specified and directed |
| 24 | S & F for 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid Moulded WPC door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 25 | S & F for Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madecomplete all as specified & directed. |
| 26 | S & F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45x85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madecomplete all as specified & directed. |
| 27 | S&F heavy duty stainless steel butt hinges 100mm in size complete all as specified and directed. |
| 28 | S&F aluminium alloy, anodised, sliding door bolt of length 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed |
| 29 | S&F aluminium anodised barrel tower bolts extruded section of size 200 mm, all as specified and directed |
| 30 | S&F aluminium handle extruded fabricate type anodised of size 150 mm complete all as spd and directed. |
| 31 | S&F steel windows with pressed steel frame made out form 1.25mm thick steel with one or more rebate (double shutter) with glazed shutters and fly proofing shutters including guard bars, hings peg stay handles tower bolts lugs including treated with for or coal tar black paint on steel surface in contact/embedded in concrete/masonry work complete all as specified and directed |
| 32 | S&F powder coated Anodised aluminium window and ventilator shutters, fixed typewithout sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 33 | M&L Framed work such as in repair grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-410-O or Fe-310-O, complete all as specified. |
| 34 | S&F, in repair MS angle iron framed work as in doors or gates of angle or other section conforming to Fe 290(Gde E-165) with gusset plates, rails, braces, etc complete including hanging also fastening and fixing complete as specified and directed. |
| 35 | Hacking out old broken glass (any thickness, size, quality or description) not exc 0.5 sq.m from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed. |
| 36 | M&L for 3mm thick figured glass, pin head type and glazing with oil putty in square not exc. 0.5 sq.m in each pane complete all as specified and directed. |
| 37 | S&F Glazing with sheet, 3mm thick, ordinary quality and glazing with oil putty and glazing pins in squares exceeding 0.5 Sqm in each pane. complete all as specified and directed |
| 38 | M&L for 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and directed. |
| 39 | S & F for 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels,commercial type on both sides face is covered with decorative face veneer with lipping/frame to match all as specified and directed |
| 40 | S&F Glazed and skelton shutters 30 mm thick Ist class hard wood, opened rebated and prepared to receive wire mesh etc, edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for sucuring witre mesh etc. Size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.24(a). complete all as specified and directed |
| 41 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed |
| 42 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed |
| 43 | Dismantling wall and ceiling boards(fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness, including cover fillets.complete all as specified and directed. |
| 44 | roviding & fixing fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG false ceiling at all heights with GRG (Glass Fibre With Reinforced Gypsum) false ceiling tiles of perforated Size 595 x 595 mm of approved texture, 12mm (b) Semi With perforated 12mm thick thick micro tegular design and patterns having moisture micro tegular edged or 1 0 mm content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge. |
| 45 | Dismantling boarding, any description fixed in any position fixed with screws complete |
| 46 | M&L, in repair, 18/19mm thick MDF Solid board, exterior grade, prelaminated one side with decorative choice laminations and other side balanceing white lamination, fixed with SS screws to WPC frame work in cup boards, and kitchen cabinet rebated complete all as specified and directed. |
| 47 | S&F 6 mm thick one side prelaminated decorative WPC sheet and other side plain in cupboard & like items inclusive of solvent cement & fixing at site complete all as specified and directed.. |
| 48 | S&F Modular auto concealed soft closed hinges 35mm 110 degree size complete all as specified and directed. |
| 49 | S&F stainless steel handle 200mm complete all as specified and directed. |
| 50 | S&F stainless steel handle 150mm complete all as specified and directed. |
| 51 | S&F PVC tape 18mm wide with adhesive complete all as specified and directed. |
| 52 | S&F for Telescopic drawer channel rollers for shelves of size 300mm long complete stainless steel of grade 304 complete all as specified and directed. |
| 53 | S&F for Telescopic drawer channel rollers for shelves of size 500mm long complete stainless steel of grade 304 complete all as specified and directed. |
| 54 | M&L for applying a coat of cement slurry @ 0.488 Kg/Sqm mixed with tapercreate @ 0.253 Kg/Sqm after cleaning and drying the old/new surfaces(Make of tapercreate M/S CICO Engg Services) then applying the layer of fibre glass cloth while the above coat is still green. The overlap of fibre glass cloth shall be not less than 100 mm.(Make of fibre glass cloth M/S The Structure Water Proofing Co Pvt Ltd) and then applying 1.5 mm thick layer @ 1.288 Kg/Sqm mixed with taper create @ 0.570 Kg/Sqm and coarse sand @ 1.289 Kg/Sqm. Allow the treatment to air curing for four hours followed by water curing for 48 hours all as directed. |
| 55 | M&L for 10 mm thick cement plaster on brick/ concrete surface in CM 1:3, but mixing water proofing compound at the rate of 2% of cement by weight (WPC shall be paid separately). |
| 56 | M&L Cement concrete Type E2 (1:5:10) using 40 mm graded stone aggregate in mass concrete in sunken floor complete all as specified. |
| 57 | M&L 75 mm thick PCC type D2 (1:4:8) using 40 mm graded stone aggregate as in sub base of flooring. complete all as specified and directed |
| 58 | M&L for 25mm thick cement concrete type B-0 1:2:4 (12.5mm graded aggregate) as in sub floors finished rough. complete all as specified and directed |
| 59 | Roughening surfaces of old concrete floor/wall by picking, sweeping clean and washing down with water to remove dust, etc and brushing and applying neat cement slurry with 3.0 Kg of cement per sq metre complete all as specified and directed. |
| 60 | S&F in repairs 20-25 mm dia draphery rods shall be made of stainless steel 20-25 mm dia pipe with decorative wooden finials as per style SW-5 , grade J4 , gauge 20mm with final / side knobs ,including fixing half openable brackets BR 100mm long with tighting alanke nuts/ side end brackets, ( in respective of complete accessories) complete all as specified and directed. |
| 61 | M & L for Providing and injecting chemical chlorpyrifos emulsifiable concentrate for Post Constructional Anti termite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron. complete all as specified and directed |
| 62 | M & L for Anti termite Treatment of soil under existing floors using chemical chlorpyrifos emulsifiable concentrate @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors all as specified . |
| 63 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 64 | S&F 4.80mm thick sheet glass, ordinary quality and glazing with oil putty in square all as specified and directed |
| 65 | S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on aluminium partitions inclusive of Solvent Cement and fixing at site complete all as specified and directed |
| 66 | M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel over one coat of primer all as specified & directed |
| 67 | M&L preparation of old steel surface of any description over 10cm width or girth and applying one coat of synthetic enamel over two coat of primer all as specified & directed |
| 68 | M&L preparation of newly or previously untreated wooden surface of any description over 10cm width or girth and applying one coat of synthetic enamel over two coat of primer all as specified & directed |
| 69 | M&L preparation of old wood surface of any description over 10cm width or girth and applying one coat of synthetic enamel over one coat of primer all as specified & directed |
| 70 | Taking down of cement plaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc. complete all as specified and directed |
| 71 | M & L 15 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and smooth withusing extra cement complete all as specified & directed. |
| 72 | M&L Rendering 5 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified. |
| 73 | M& L preparing plastered new surfaces of ceiling and applying two coats of white wash on ceiling surface complete all as specified and directed |
| 74 | M&L for 15 mm thick rendering using ready mix plaster bags in cement mortar1:4 on brick / concrete surfaces of external walls finished even and fiar, using water proofing compound @200ML weight of 50kg cement or as per manufacturer instructions complete all as specified and directed : |
| 75 | M&L for two component polymer modified flexible cementitious waterproof (breathable) coating of equivalent flexible and elastic polymer modified, 2 component cementitious coating system having UV resistance applied in 2 coats in the form of slurry at right angles by way of brush at a total consumption of 2 Kg per sqm over the vertical brick wall, curing, testing etc completed including gola vata & joints treatment etc. complete all as specified and as diected by Engr-in-charge. |
| 76 | M&L for providing protective levelling plaster for horizontal & vertical surfaces of average 15 thick in cement mortar (1:4) including mixed with liquid integral waterproofing admixture @ 200 ml per bag of cement, finished smooth, curing etc. complete as specified and as diected by Engr-in-charge. |
| 77 | Supply Liquid water proofing compound complete all as specified and directed |
| 78 | M&L complete removal of existing treatment of wall by mechanical and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed. |
| 79 | M&L for 1 coat of priming plastered and other surface with alkali resistant priming paint using roller complete all as specified and directed. |
| 80 | M & L for newly plastered surfaces of wall applying two coats of distemper oil emulsion complete all as specified and directed. |
| 81 | Providing and applying 3mmthickness wall care putty on wall over plastered surface toprepare the surface even and smooth.complete all as specified and directed. |
| 82 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces using roller for painting . |
| 83 | M&L complete removal of existing treatment of wall by mechanical means and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm . |
| 84 | M& L complete removal of existing treatment of Old surfaces of walls applying two coats of white wash complete all as specified and directed |
| 85 | M& L preparing plastered Old surfaces of ceiling applying one coats of white wash complete all as specified and directed |
| 86 | Taking up or down steel tubing and connection 15 mm bore pipe and removing from site. complete all as specified and directed |
| 87 | All as per Sl Item No.62 here-in-before but 20 mm bore pipe. complete all as specified and directed |
| 88 | Supplying and laying of 15 mm bore galvanized iron tubes medium grade with all fittings and fixed on walls/ceiling or laying in floors complete all as specified. incl holding the pipe with stainless steel ring with powder coated aluminium frame at 1 mtr c/c to be fixed walls where as required |
| 89 | Supplying and laying of 20mm bore galvanized iron tubes medium grade with all fittings and fixed on walls/ceiling or laying in floors complete all as specified. incl holding the pipe with stainless steel ring with powder coated aluminium frame at 1 mtr c/c to be fixed walls where as required. |
| 90 | Cutting chases ,pinning in brick work girth exc 10cm but n exc 20 cm and making good to facing where required and poining ein cement mortar 1:3 to ends of edges of landing, sun shades, chajjas, shelves etc complete all as specified and directed |
| 91 | S&F in repairs 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm- 690 gms) complete all as specified and directed |
| 92 | S&F in Floor 140mm over all length with flap door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed |
| 93 | S&F fancy type CP angle valve/concealed stop cock of cast copper alloy (ISI Marked) chromium plated fancy type scrwed down high pressure with capstain head screwed both ends for iron pipe 20mm bore complete all as specified and as directed by engr-in-charge. |
| 94 | S&F in repair Vitreous China wash basin including pedestal, white, flat back, size 550 x 400 mm, including fixing acessories like galvanised brackets & rag bolts,32 mm CP waste coupling complete all as specified. |
| 95 | S&F in repair vitreous china wash down water closet pan (padestal pattern), white including plastic water closet seat cover, white, closed pattern flat bottom and mild steel chromium plated or aluminised hinging device. complete all as specified and directed |
| 96 | S&F in repairs Health faucet cast copper alloy chromium plated with flexible chrome hose and wall SS hooks complete all as specified and directed. |
| 97 | S&F in repairs Vitreous china wash down water closet single piece complete single unit including double syphonic flusing cistern white, seat cover, connection to drain trap complete. all as specified and directed. |
| 98 | S&F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe fixed in repair. complete all as specified and directed |
| 99 | S&f Iin repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 100 | S&F fancy type glass corner fancy type of size 250mm x 250mm of 6 to 7mm thick toughned glass with CP railing fixed with fancy type screws complete all as specified and directed. |
| 101 | S&F (in repair)chromium plated towel rail 20mm dia D type 600 mm long as a approved quality.complete all as specified and directed. |
| 102 | Supply and fixing waste pipe any type of pipe 32mm bore suitable for wash hand basins/sinks complete all as specified & directed |
| 103 | S&F in repair 10 litre capacity PVC valveless, Syphonic action type, fluhing cistern low level,white with inlet ball valve, float and handle including brackets and PVC flush pipe etc complete all as specified and directed. |
| 104 | Supply & fix in repairs PVC connections of 450mm long suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed. |
| 105 | Supply & fixed, in repair, PVC connections 15mm size with brass/ PVC nut both side of length 600mm complete all as directed. |
| 106 | S&F in repair sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing with Granite Stone and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed |
| 107 | S&F in repair Brass chromium plated shower rose 125mm size all as specified and directed |
| 108 | S&F in repair CP soap dish complete all as specified |
| 109 | S &F in repair stainless steel CP grating doom 100mm dia complete all as specified |
| 110 | Taking down eaves gutter and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan-necks etc including cleaning or refixing or removal to store (measured overall as fixed along the center line over fittings and accessories) and S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointed fixed to walls upto double storey inc formwork complete all as specified and as directed by Engr-in-charge. |
| 111 | Taking down eaves gutter and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan-necks etc including cleaning or refixing or removal to store (measured overall as fixed along the center line over fittings and accessorie) S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointed fixed to walls upto double storey incl necessary formwork complete all as specified and as directed by Engr-in-charge. |
| 112 | S&F factory made 600 x 450 mm beveled edge mirror 5.5mm thick of selected quality glass and fixed to wooden plugs with chromium plated brass screws and cup washers (In repairs) complete all as specified and directed |
| 113 | S&F in repair of vitreous china squatting pan ‘Orrisa pattern’ size 580 x 440 mm white with integral foot rest including replacement of ‘P’ or ‘S’ trap lime concrete bedding and making good floor complete all as specified and directed. |
| 114 | Supply and fix PVC bends 75mm bore, any radius complete all as specified & directed. |
| 115 | Supply and fix PVC bends 110 mm bore, any radius complete all as specified & directed. |
| 116 | S&F 110mm PVC (SWR) vent cowl all as specified |
| 117 | S&F 110 PVC (SWR) junction single, (Single T) equal or unequal all as specified |
| 118 | S^F 110mm PVC (SWR) 'S' trap all as specified |
| 119 | S&F in repair Gun metal globe or gate valves with Iron wheel head screwed both ends for iron pipe 20 mm dia.fixed in repair) complete all as specified and directed |
| 120 | S&F (in repair)chromium plated towel rail 20mm dia D type 600 mm long as a approved quality.complete all as specified and directed. |
| 121 | M&L for pcc 1:3:6 type C1 using 20mm graded stone aggragate as in bed bricks, coping etc including weathering slightly rounded or chamfered angles and throating making grovves for fixing of man hole cover including necessary form work. complete all as specified and directed |
| 122 | Taking down old existing water proofing treatment from the top of RCC/ arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises complete all as specified & directed. |
| 123 | Material and Labour for 10mm thick cement paster in CM 1:4 mixed with WPC @ 2 % by weight of cement finised even and smooth without using extra cement on roof surface when concreate is green and wall (WPC will be measured and paid seperately as supply only rate). |
| 124 | M & L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application and over two coat aluminium paint and incl remove existing treatment complete all as specified |
| 125 | M&L for chequered cement concrete colour tiles size 20 cmx20mmx25 mm thick, with grey pigment cement and colour pigment, set, jointed and pointed in neat cement slurry over and including 20 mm thick screed bed in cm (1:6) complete all as specified and directed. |
| 126 | Dismantling asbestos cement (corrugated, semi-corrugated, etc) sheet in roof coverings and height of buildings upto 6mtr with out stair case all as specified and directed. |
| 127 | Supplied and fixed pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with hot dip galvanised self dirilling and self tapping screws neoprene and EPDM washers complete all as specified and directed |
| 128 | Supplied and fixed pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with hot dip galvanised self dirilling and self tapping screws neoprene and EPDM washers complete all as specified, directed |
| 129 | S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc including notching, drilling, fittings, riveting and / or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing fittings angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing conf to Fe-410-w (Gde-E -250) quality A complete all as specified and directed. |
| 130 | Demolition of reinforced concrete of any description and any poisition not otherwise specifically provide ( reinforcement cut to faciliatate demolition) complete all as specified and directed |
| 131 | M & L precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggegrate) as in Chullah hood chajja and manhole cover, kitchen shelves etc set in cement mortar 1:6.including all neccesary formwork & finishing exposed concrete surface all as specified and directed |
| 132 | M&L for Cleaning and removing all scale and dirt from water tank exc 250 ltr not exc 500 ltr etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed |
| 133 | M&L for Cleaning and removing all scale and dirt from water tank exc 500 ltr not exc 1000 ltr etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed |
| 134 | Taking down copper/ aluminium point wiring (light, fan, bell, socket or power etc.) complete with all accessories like switches, sockets, regulators, ceiling roses, light fittings etc. for taking credit and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floors / ceiling etc complete all as specified and directed. NOTE- For Industrial bldgs with height approx 30 feets, all T & P arrangements will be done at contractor end , no crane facility will be provided by the department for any item in contract. |
| 135 | M&L for concealed point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSH, conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable FR-LSH ,ISI marked including PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, alongwith frame inner plate suitable for fixing moduler switches, sockets, regulator etc or with 3mm thick plastic laminated sheet top cover concealed in wall any height with and including continuous green earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly including cutting holes in or through the walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed for:The point wiring shall include the wiring of light/ outlets of any length from the distribution board via switch to the point. (a) One light point controlled by one way switch. |
| 136 | All as described item Ser No 135 here-in-before One light point controlled by 2-way switch. complete all as specified and directed |
| 137 | All as described item Ser No 135 here-in-before One ceiling fan/ exhaust fan point controlled by one way switch. complete all as specified and directed |
| 138 | All as described item Ser No 135 here-in-before One 3 pin socket outlet 6 Amps on the same board with other switches. complete all as specified and directed |
| 139 | All as described item Ser No 135 here-in-before One 3 pin socket outlet 6 Amps on the Independent board. complete all as specified and directed |
| 140 | All as described item Ser No 135 here-in-before One bell/ buzzer point controlled by one push button on the same board with other switches or independent. complete all as specified and directed |
| 141 | All as described item Ser No 135 here-in-beforebut with 2.5 Sq mm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor complete all as specified and as directed. |
| 142 | All as described item Ser No 135 here-in-before but using 4 sqmm copper conductor for with 4 sqmm earth wire for one 20 amps socket outlet on independent board all as directed. |
| 143 | All as described item Ser No 135 here-in-before but for supply and drawing 1.5 sqmm copper conductor cable with one 1.5 sqmm continuous earth wire into existing conduit after taking out the existing wiring including replacement of required size of terminal box with 3mm thick bakelite sheet cover fixed with brass screws all as specified and as directed for :- (a) One light point / Fan point controlled by one way switch. |
| 144 | All as described item Ser No 143 here-in-before One light point controlled by 2-way switch. complete all as specified and as directed |
| 145 | All as described item Ser No 143 here-in-before One 3 pin socket outlet 6 Amps on the same board with other switches. complete all as specified and as directed |
| 146 | All as described item Ser No 143 here-in-before One 3 pin socket outlet 6 Amps on the Independent board. complete all as specified and as directed |
| 147 | All as described item Ser No 143 here-in-before One bell/ buzzer point controlled by one push button on the same board with other switches or independent. complete all as specified and as directed |
| 148 | All as per ser item SEr No 143 here-in-before but for supply and drawing 2.5 sqmm copper conductor cable with one 2.5 sqmm continuous earth wire into existing conduit after taking out the existing wiring including replacement of required size of terminal box with 3mm thick bakelite sheet cover fixed with brass screws all as specified and as directed for one 16 amps socket outlet on independent board. complete all as specified and as directed |
| 149 | S&F Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked complete all as specified and directed. |
| 150 | S&F Modular Switch, 1 module, 6A, AC, 240V, two way ISI Marked complete all as specified and directed.. |
| 151 | S&F Modular Socket, 2 module, 6A, 3 pin combined, AC, 240V, ISI Marked complete all as specified and directed.. |
| 152 | S&F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked complete all as specified and directed.. |
| 153 | S&F Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked complete all as specified and directed.. |
| 154 | S&F modular outer plate with inner plate frame 3 module suitable for modular switch & board complete all as specified and directed. |
| 155 | All as described item Ser No 154 here-in-before but 4 module complete all as specified and as directed |
| 156 | All as described item Ser No 154 here-in-beforebut 6 module complete all as specified and as directed |
| 157 | All as described item Ser No 154 here-in-before but 8 module complete all as specified and as directed |
| 158 | All as described item Ser No 154 here-in-before but 12 module complete all as specified and as directed |
| 159 | S&F modular metal flush box 3 module suitable for modular switch & board complete all as specified and directed. |
| 160 | All as described item Ser No 159 here-in-before but 4 module complete all as specified and directed. |
| 161 | All as described item Ser No 159 here-in-before but 6 module complete all as specified and directed. |
| 162 | All as described item Ser No 159 here-in-before but 8 module complete all as specified and directed. |
| 163 | All as described item Ser No 159 here-in-before but 12 module complete all as specified and directed. |
| 164 | S&F in repair Switch Piano, flush type single pole, one way 6 Amps complete all as specified and as directed. |
| 165 | S&F in repair Switch Piano flush type two way 6 Amps complete all as specified and as directed. |
| 166 | S&F in repair Switch Piano, flush type single pole, one way 16 Amps complete all as specified and as directed. |
| 167 | S&F in repair Switch bell push 6 Amps flush type complete all as specified and directed. |
| 168 | S&F in repair socket outlet 3 pin and 6 Amps flush type complete all as specified and as directed. |
| 169 | S&F in repair socket outlet flush type 2 in 1, 3 pin , 6 and 16 Amps complete all as specified and as directed |
| 170 | S&F in repair switch/socket combined complete with box, 16 Amps, complete all as specified and as directed. |
| 171 | S&F in repair switch/socket combined, flush type, 16 Amps, complete all as specified and as directed. |
| 172 | S&F Modular 5 Step Fan Regulator, 1/2 module, 120W, AC, 240V, ISI Marked complete all as specified and directed.. |
| 173 | S&F non modular 5 Step Fan Regulator (switch type/socket type), 1/2 module, 120W, AC, 240V, ISI Marked complete all as specified and directed. |
| 174 | S&F in repair Ceiling rose PVC/ Polycorbonate insulated body with three terminals complete all as specified and as directed. |
| 175 | S&F in repair bell, Ding Dong AC, 230 volts, SP complete all as specified and as directed. |
| 176 | S&F in repairs lamp holder, angular/ straight ,PVC / Polycarbonate type with batten back plate, AC, 240V, Pin type, ISI marked complete all as specified and directed.. |
| 177 | S & F 20 W surface / wall mounted,single rod 4 feet LED T-8 batten having luminous efficacy of ≥100 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser,CRCA housing with white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge.NOTE: The rate to be quoted by the contractor should be inclusive of the LED T-8 batten along with a 4 feet LED rod. |
| 178 | S&Fin repairs Retrofit polycarbonate diffuser type 20 watt retrofit LED tube rod 4 feet,100Lm/Watt,CRI >80, PF >0.90, operating volatage 140- 240V complete all as specified and directed. |
| 179 | S & F 20 W surface / wall mounted, 4 feet LED T-5 batten industrial type having PC diffuser, luminous efficacy of ≥120 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection 4kV and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, housed in PC with white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz,50000Hr run including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge. |
| 180 | S & F 10 W surface / wall mounted, 2 feet LED T-5 batten having PC diffuser, luminous efficacy of ≥100 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in PC with white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge. |
| 181 | S&F post top light any shape with opal acrylic diffuser,die cast aluminium bottom housing, IP65/66 suitable for outdoor including all the accessories required for fixing as per OEM recommendation all as specified and directed by Engr-In-Charge. |
| 182 | S&F in repairs LED Bollard garden light cylindrical shape with opal acrylic diffuser IP65/66 suitable for outdoor IP65 including all the accessories required for fixing all as specified and directed by Engr-In-Charge. |
| 183 | S&F in repairs, Wall mounting focus light with polycarbonate diffuser prewired incl 14/15 Watts LED lamp complete all as specified and directed. |
| 184 | Supply & fix in repair/ replacement LED 10 watt (Bulk head light fitting) cast aluminium oval shape body finished with stove enameled & heat resistant oval shape designed clear /diffuser glass cover with rubber gasket complete all as specified and as directed. |
| 185 | S&F in repairs pressure die-cast alluminium housing 18 Watt LED flush / surface/recessed mounting down light luminaire powder coated finish in round or square shape with integral electronic driver THD<10% complete all as specified and directed. |
| 186 | S&F in repairs pressure die-cast alluminium housing 12 Watt LED flush / surface/recessed mounting down light luminaire powder coated finish in round or square shape with integral electronic driver THD<10% complete all as specified and directed. |
| 187 | S&F in repairs 25 Watt prewired pressure die cast housing LED bldg security light luminaire IP 66 ingress protection ,Efficacy 120lm/watt ,built-in surge protection,electronic driver incl suitable OD GI pipe bracket, mounting clamps with nuts, bolts and washers, electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose/junction box to the fixture complete all as specified and directed by the engineer-in-charge. |
| 188 | All as described item ser No 187 here-in-before but 35 Watts.complete all as specified and directed. |
| 189 | S&F 15 watt LED bulb 2 pin B22 base,100 Lumems per watt,PF≥0.9, 180° wide beam angle voltage surge protection 4kV ,6500K cool white/warm white,operating voltage 100-240V complete all specified and directed. |
| 190 | All as described item Ser No 189 here-in-before but 20 Watts. complete all as specified and directed. |
| 191 | All as described item Ser No 189 here-in-before but 12 Watts complete all as specified and directed. |
| 192 | All as described item Ser No 189 here-in-before but 9 Watts complete all as specified and directed. |
| 193 | All as described item Ser No 189 here-in-before but 5/6 Watts complete all as specified and directed. |
| 194 | S & F in repair 36W LED recessed mounted 2'X2' panel light having CRCA sheet housing, PC diffuser, luminous efficacy of 120 lumen/W, CRI > 80, PF ≥ 0.9, CCT 6500K/3000K, independent isolated SMPS based constant current electronic LED driver with THD < 15%,built-in surge voltage protection min 4kV and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, IP 20 protection, input voltage range 140- 270V , input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge. |
| 195 | M & L for submain wiring with two single core 6 sq mm nominal area with 1100 volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 6 sq mm multi stranded copper conductor cable (FRLSH) ISI marked for continuous green earth wire drawn in and including concealed rigid non-metallic PVC conduit (ISI mark) of size 25 mm or higher dia medium grade with all fitting marked including cutting, chasing for conduit and making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed.Note:- Two runs of 6 Sqmm Cable and one run of 6 Sqmm cable together in & including PVC conduit shall be measured as one RM. |
| 196 | M & L for submain wiring with four single core 6 sq mm FRLSH nominal area for 3 phase & neutral with 1100 volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 6 sq mm multi stranded copper conductor cable (FRLSH) ISI marked for continuous green earth wire drawn in and including concealed rigid non-metallic PVC conduit (ISI mark) of size 19/20 mm dia medium grade with all fitting marked including cutting, chasing for conduit and making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed.Note:- Four runs of 6 Sqmm Cable and one run of 6 Sqmm cable together in & including PVC conduit shall be measured as one RM. |
| 197 | M & L for submain wiring with two single core 10 sq mm nominal area with 1100 volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 10 sq mm multi stranded copper conductor cable (FRLSH) ISI marked for continuous green earth wire drawn in and including concealed rigid non-metallic PVC conduit (ISI mark) of size 25 mm dia medium grade with all fitting marked including cutting, chasing for conduit and making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed.Note:- Two runs of 10 Sqmm Cable and one run of 10 Sqmm cable together in & including PVC conduit shall be measured as one RM. |
| 198 | M & L for submain wiring with four single core 10 sq mm FRLSH nominal area for 3 phase & neutral with 1100 volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 10 sq mm multi stranded copper conductor cable (FRLSH) ISI marked for continuous green earth wire drawn in and including concealed rigid non-metallic PVC conduit (ISI mark) of size 25 mm or higher dia medium grade with all fitting marked including cutting, chasing for conduit and making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed.Note:- Four runs of 10 Sqmm Cable and one run of 10 Sqmm cable together in & including PVC conduit shall be measured as one RM. |
| 199 | S&F in repairs, incl clamping and fixed to wall / pole / channels, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables with stranded aluminium conductor, 1100 volts grade, 16 Sqmm 4 core complete all as specified and directed. |
| 200 | S&F in repair Metallic Enclosure, SPN double door DB, IP43, door earthing,isolated neutralbar ,240V, AC, 4 way, with 200 Amps rated busbar ISI Marked complete all as specified and directed. |
| 201 | All as described item Ser No 200 here-in-before but 08 way complete all as specified and directed. |
| 202 | All as described item Ser No 200 here-in-before but 12 way complete all as specified and directed. |
| 203 | All as described item Ser No 200 here-in-before but TPN DB, vertical mounting, 415V, 4way with 200Amps rated busbar, double door. complete all as specified and directed. |
| 204 | All as described item Ser No 200 here-in-before but VTPN DB, incomer MCCB type, 415V, 4way with 200Amps rated busbar, double door. complete all as specified and directed. |
| 205 | S&F in repairs, 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16KA with Thermal - Magnetic Released complete all as specified and directed. |
| 206 | All as described item Ser No 205 here-in-before but 100Amps 16KA complete all as specified and directed. |
| 207 | S&F in repair MCB SP 6-32 Amps, 10 kA, 415 volts, 50 Hz suitable for fixing in MCB DB 'B' series complete all as specified and as directed. |
| 208 | S&F in repair MCB SP 6-32 Amps, 10 kA, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed. |
| 209 | S&F in repair Isolator DP, 40A, AC, 240V, ISI/CE Marked conforming to IEC 60947-3,biconnect terminals complete all as specified and directed. |
| 210 | All as described item Ser No 209 here-in-before- but 63A complete all as specified and directed |
| 211 | S&F in repair Isolator 4P, 63A, AC, 415V, ISI/CE Marked complete all as specified and directed. |
| 212 | Taking down unserviceable plug and socket of any description, supply and fix sheet metal enclosure with single pole and neutral with two pin and earth plug and socket along with a 20 to 30Amps rated SP MCB, 230 volt, 50 HZ as required at site, complete all as specified and as directed. |
| 213 | Supply & fix in repair condenser 2.5 MFD suitable for ceiling/ Exhaust fan complete all as specified and as directed. |
| 214 | Supply & fix in repair condenser 3.15 / 4 MFD suitable for ceiling/ Exhaust fan complete all as specified and as directed. |
| 215 | Supply only insulation tape roll 20 mm wide 15 Mtr long ISI marked all as directed. complete all as specified and directed. |
| 216 | Supply and fix Water heater storage type steel body with heating element upto 2KW, capacity 25 ltr, BEE 5 star complete including providing hold fast in wall and PVC connection 45 cm long with 15 mm dia brass union at both end heavy duty complete all as specified and directed by Engr-in-charge. |
| 217 | Supply and fix Water heater storage type steel body with heating element upto 2KW, capacity 50 ltr, BEE 5 star complete including providing hold fast in wall and PVC connection 45 cm long with 15 mm dia brass union at both end heavy duty complete all as specified and directed by Engr-in-charge. |
| 218 | Carrying out Electrical maint work of day to day Internal Electric or Fans or Geysers or Solar Water Heaters complaints such as repair / rectification / replacement of defective items like wiring, cables, switches, sockets,holders, ceiling rose, call bells, condensers,tube rods,fittings,fixtures,LED drivers,MCB's,MCCB's,DB's,Heating Elements,Thermostats, Hot water connections etc. by providing skilled Technician at any location under GE (North) Meerut AoR all as specified and directed by Engr-in-Charge.(Store required will be provided seperately) |
| 219 | S&F in replacement of PVC water disributer 3 way with PVC pipe 15 mm with 15 mm dia flexible braided OD for Desert cooler of any size/capacity. |
| 220 | S&F in replacement of Submersible pump 18 watt, 230V, single phase for Desert cooler of any size/capacity. complete all as specified and directed. |
| 221 | S&F in replacement of wood wool pad for desert cooler of suitable size in wire net complete weight not less than 450 gms. ( set of three ) complete all as specified and directed. |
| 222 | S&F in replacement fan motor copper wounded suitable for desert cooler 230 Volts, 50HZ, single phase, Heavy duty, AC supply four speed 180 watts of 450 mm sweep complete with fan blade and legs completed. |
| 223 | S&F in repairs, PVC fresh air fan, 300mm sweep with louvers, AC, 230V incl T/D old u/s one and depositing to MES complete all as specified and directed. |
| 224 | S&F in repair PVC exhaust fan, 250mm sweep with lovers, AC, 230V incl taking down old u/s one and depositing to MES complete all as specified and directed. |
| 225 | S&F in repair metal exhaust fan, 300mm sweep with lovers/bird guard, AC, 230V incl taking down old u/s one and depositing to MES complete all as specified and directed. |
| 226 | S&F in repair wall mounted fan 400mm sweep, smooth oscillation,3 speed control,copper winded motor ,electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose/junction box to the fixture complete incl taking down old u/s one and depositing to MES Storeyard all as specified and directed by the engineer-in-charge. |
| 227 | Supply & fix in repair/ replacement copper cable 1100 volts grade with multi-stranded copper conductors of size 1.5 Sqmm complete all as specified and as directed |
| 228 | Supply & fix in repair/ replacement copper cable 1100 volts grade with multi-stranded copper conductors of size 2.5 Sqmm complete all as specified and as directed |
| 229 | Supply & fix in repair/ replacement copper cable 1100 volts grade with multi-stranded copper conductors of size 4.0 Sqmm complete all as specified and as directed |
| 230 | Supply & fix in repair/ replacement PVC insulated copper cable 1100 volts grade twin twisted flexible conductor 23/0.76 complete all as specified and as directed |
| 231 | Supply & fix in repair/ replacement PVC insulated copper cable 1100 volts grade twin twisted flexible conductor 40/0.60 complete all as specified and as directed |
| 232 | Supply & fix in repair/ replacement Temper proof digital energy meter Single Phase 230 volts of capacity 5-30A complete all as specifeid and as directed. NOTE: Taken down unsv Electric meter of any description will be deposited in E/M store. |
| 233 | Supply & fix in repair/ replacement Temper proof digital energy meter three Phase 415 volts of capacity 10-40A complete all as specifeid and as directed. NOTE: taken down unsv Electric meter of any description will be deposited in E/M store. |
| 234 | M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including 4.0 mm galvanized iron wire as earth lead, extended upto 7.5 m or upto test terminal point, drawn through 15mm dia med. gr. GI pipe for protection of galvanized iron wire in the ground, further connecting with suitable size of earthing lead to Distribution boards etc., including excavation, earth work, Charcoal & Salt all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, wire net, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt-I, complete all as specified and as directed. NOTE: a) GI Pipe for protection of earthing strip and earth strip beyond 7.5m or test point shall be measured and paid seperately under relevant items. |
| 235 | Taking down ceiling fan of any description, sealing cable ends, dismantling blades, cleaning all dust, applying grease, filling cavaties with fillet, painting with synthetic enamel paint by spraying including reassembling blades and hanging ceiling fan including connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose fan connector complete all as specified and as directed. |
| 236 | All as per item description here-in-before but exhaust fans of any sweep complete all as specified and as directed. |
| 237 | Dismantling the unserviceable bearing and supply and fix sealed bearing suitable for the existing Ceiling fans / exhaust fans complete all as specified and as directed. |
| 238 | Dismantling the unserviceable Gun metal bush and supply and fix new gun metal bush suitable for existing wall mounted/ pedestal/ exhaust fans complete all as specified and as directed. |
| 239 | Dismantle the unserviceable shackle assembly and supply and fix new shackle assembly comprising GI bolts, nuts, rubber bush and split pin complete all as specified and as directed. |
| 240 | Material & labour for removing the defective fan winding of any material and rewinding with super enamelled copper wire of existing (or higher gauge), in case where winding is of any other material), applying insulation varnish, pre heating and binding with empire tubes, crimple sheet, etc. as required for rewinding, replacement of body screws, and after that, testing and commissioning on full load for 4 hrs continuous running in the presence of MES maintenance incharge, complete all as specified and directed. (a) Ceiling fan of size upto 1200/1400 mm sweep. |
| 241 | All as described item Ser No 240 here-in-before Exhaust fan of size 350 to 450mm Sweep. complete all as specified and directed. |
| 242 | All as described item Ser No 240 here-in-before Exhaust fan of size upto 300 mm Sweep. complete all as specified and directed. |
| 243 | Taking down the electric Geyser of capacity 25 ltrs/ 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, electrical connections, dismantling the unit, painting with one coat of synthetic enamel paint and refixing in its original position and reconnecting the inlet/ outlet water pipes and testing on completion complete all as specified and as directed. |
| 244 | Supply and fixing of following items in repairs, suitable for single phase, 230 Volts, 50 Hz for existing type electric Geyser of capacity 25/50 ltrs including taking down unsv spares items complete all as specified and as directed:- (a) Geyser heating element 1500 / 2000 watts push/ thread type porcelain / Circular / triangular type as required at site. |
| 245 | All as described item Ser No 244 here-in-before but Thermostat as per the existing type at site. complete all as specified and directed. |
| 246 | All as described item Ser No 244 here-in-before but Thermostate controller of existing type at site. complete all as specified and directed. |
| 247 | All as described item Ser No 244 here-in-before but Indication lamp red/ green. complete all as specified and directed. |
| 248 | All as described item Ser No 244 here-in-before but Aperture plate assembly complete for the geyser of capacity 25 ltr complete all as specified and directed. |
| 249 | All as described item Ser No 244 here-in-before but Aperture plate assembly complete for the geyser of capacity 50 ltr complete all as specified and directed. |
| 250 | Taking down the electric geyser of capacity 25 Ltrs / 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, dismantling the unit, taking out the inner leaking copper shell, brazing the copper shall, testing for leaks, re-assembling the geyser including provision of additional glasswool as required, refixing in position, testing for functionality and commissioning complete all as specified and as directed. |
| 251 | Taking down unserviceable PVC connection of any description and supply and fix new PVC connection 15mm dia 450mm long with brass nuts, and rubber washers on both sides suitable for cold/ hot water complete all as specified and as directed. |
| 252 | Taking down unserviceable PVC connection of any description and supply and fix new PVC connection 15mm dia 600mm long with brass nuts, and rubber washers on both sides suitable for cold/ hot water complete all as specified and as directed. |
| 253 | Servicing of Solar water Heater of any capacity complete by cleaning solar panel with suitable cleaning agent, providing new rubber pipes along with clamps of suitable size for arresting leakages complete all as specified and as directed. |
| 254 | Supply and fixing in repairs Solar water heater heating element of capcity 3 KW, single phase, 230 Volts, 50 Hz for existing type Solar water geyser including taking down unsv spares complete all as specified and as directed. |
| 255 | Disconnect and remove unserviceable starting relay and Supply and fix new starting relay suitable for existing model of following cooling appliances complete all as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs |
| 256 | All as described item Ser No 255 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs complete all as specified and as directed. |
| 257 | Disconnect and remove unserviceable over load protector and supply and fix new overload protector (OLP) suitable for existing model of following cooling appliances complete all as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs |
| 258 | All as described item Ser No 257 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs complete all as specified and as directed. |
| 259 | Disconnect and remove unserviceable thermostat and supply and fix new thermostat suitable for existing model of following cooling appliances complete all as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs |
| 260 | All as described item Ser No 259 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs complete all as specified and as directed. |
| 261 | Disconnect and remove unserviceable starting capacitor and supply and fix new starting capacitor suitable for existing model of following cooling appliances complete all as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs |
| 262 | All as described item Ser No 261 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs complete all as specified and as directed. |
| 263 | Disconnect and remove unserviceable running capacitor and supply and fix new running capacitor suitable for existing model of following cooling appliances complete ass as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs |
| 264 | All as described item Ser No 263 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs complete all as specified and as directed. |
| 265 | Disconnect and remove unserviceable compressor and supply and fix new sealed rotary/ reciprocating compressor, including brazing the suction/discharge lines suitable for existing model of following cooling appliances, filling the gas and testing on all as specified and as directed. (a) Water cooler of capacity 40/80 Ltrs |
| 266 | All as described item Ser No 265 here-in-before but Water cooler of capacity 60/120 Ltrs complete all as specified and as directed. |
| 267 | All as described item Ser No 265 here-in-before but Refrigerator/ deep freezer of capacity upto 165 Ltrs complete all as specified and as directed. |
| 268 | All as described item Ser No 265 here-in-before but Refrigerator/ deep freezer of capacity 310/320 Ltrs complete all as specified and as directed. |
| 269 | M&L for Checking of leakage of of the following cooling appliances by putting the nitrogen pressure, identifying the leaks / defects ,repairing the same by brazing/ welding of bottom leg supports and testing and vaccuumising the system and charging suitable refrigerant gas and oil in desired level complete all as specified and as directed . (a) Water cooler of capacity 40/80 Ltrs |
| 270 | All as described item Ser No 269 here-in-before but Water cooler of capacity 60/120 Ltrs complete all as specified and as directed |
| 271 | All as described item Ser No 269 here-in-before but Refrigerator/ deep freezer of capacity upto 165 Ltrs complete all as specified and as directed |
| 272 | All as described item Ser No 269 here-in-before but Refrigerator/ deep freezer of capacity 310/320 Ltrs complete all as specified and as directed |
| 273 | Taking down the corroded body of water cooler of any capacity, tinkering the corroded sheet metal parts, bottom base, angle iron frame, fan motor base plate, side covers, legs, door etc. with appropriate gauge MS sheet, angles by welding and brazing, renewal of nuts and bolts sheets metal screws, re-assembling, preparing the surface and painting with two coats of synthetic enamel paint over a coat of zinc chrome primer including renewal of door gasket where ever required complete all as specifeid and as directed. |
| 274 | Taking out unserviceable waste water tray of any description and supply and fix new steel waste water tray suitable for existing water coolers complete all as specified and as directed. |
| 275 | Taking out unserviceable ball valve assembly and supply and fix new PVC ball valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of size 15 mm dia bore suitable for water coolers / desert coolers complete all as specified and as directed. |
| 276 | Taking out unserviceable push button tap and supply and fix new chromium plated push button tap of size 15 mm dia bore suitable for water cooler complete all as specified and as directed. |
| 277 | Taking out unserviceable stop valve of any description and supply and fix new stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions of size 15mm dia complete all as specified and as directed. |
| 278 | Taking out unserviceable PVC waste water pipe from Water cooler and supply and fix new PVC waste water pipe of suitable size complete all as specified and as directed. |
| 279 | Supply and fixing in replacement of new compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection making all existing connection including testing complete all as directed for 1.5 ton Window /Split type Air conditioners (inverter/non-inverter). |
| 280 | capacity 2 ton Window /Split type Air conditioners (inverter/non-inverter). complete all as specified and directed |
| 281 | M&L for charging Gas refrigerant R22/R32/R410A/R134a in the sealed system of window/Split type (inverter/non inverter) AC 1.5/2 Ton capacity after checking leakage / pressure vacuumising, flushing the sealed unit including replacement of filter dryer and capillary tube complete all as specified and directed. |
| 282 | Taking down of window/Split AC 1.5/2.0 ton capacity of any type/any model and cleaning / servicing of AC, overhauling of blower motor replacement of worn out parts, preparation of body for painting one coat of black paint inner side and one coat synthatic enameled paint on the outer cover of AC and marking of SM/MES No and testing of full load of summer season and reinstallation at site complete all as specified and directed. Note : Worn out parts shall be measured & paid seperately. |
| 283 | S&F in repair Blower motor 1/6 HP with base / rubber bush complete Suitable for split AC of capacity 1.5/2 TR any make / model complete all as specified and directed |
| 284 | All as per item here-in-before but Condensor fan motor Suitable for Split AC/ Window AC double ended of capacity 1.5 / 2 Ton AC complete all as specified and directed |
| 285 | All as per item here-in-before but Condensor fan blade metallic. complete all as specified and directed |
| 286 | All as per item here-in-before but Drum type blower fan PVC as per existing. complete all as specified and directed |
| 287 | All as per item here-in-before but Running capacitor 36 mfd. complete all as specified and directed |
| 288 | All as per item here-in-before but Starting capacitor 100 to 120 mfd complete all as specified and directed |
| 289 | All as per item here-in-before but Selector switch, any make / any model complete all as specified and directed |
| 290 | All as per item No here-in-before but Thermostate complete all as specified and directed |
| 291 | All as per item here-in-before but with plastic / jute Air filter. complete all as specified and directed |
| 292 | All as per item here-in-before but cooling coil assembly suitable for any make / any model as per site requirement. complete all as specified and directed |
| 293 | All as per item here-in-before but Condensor coil assembly. complete all as specified and directed |
| 294 | All as per item here-in-before but Wiring kit complete. |
| 295 | All as per item here-in-before but Capacitor 6 mfd. complete all as specified and directed |
| 296 | All as per item here-in-before but Blower motor 1/3 HP for indoor unit split type AC suitable for any Make / any model as per site requirement. complete all as specified and directed |
| 297 | All as per item here-in-before but Running capacitor 45 mfd. complete all as specified and directed |
| 298 | All as per item here-in-before but Blower fan 3 Ft long suitable for split AC (as per existing) complete all as specified and directed. |
| 299 | Supply and fix in replacement of electronic circuit plate (PCB) with remote control including necessary repairs to electronic circuit operation suitable for 1.5 / 2.0 ton split/window type AC . complete all as specified and directed |
| 300 | Supply and fix in replacement Air break contactor relay 6.2 Amps, 415 Volts AC suitable for split type AC complete all as specified and directed. |
| 301 | Labour for shifting of split AC ( Indoor/Outdoor unit) 1.5 /2 ton capacity from one place to another place as required at site including (i) disconnecting existing copper tubing (ii) disconnecting PVC pipe connection (iii) installation of the same AC (Indoor/Outdoor unit) at new location complete with (i) Gas charging tested on full load (ii) new stand for ODU complete all as specified and directed. |
| 302 | Taking out unserviceable plug top of any description and supply and fix new plug top 3 pin 16 Amps single phase 230 volts complete all as specified and as directed. |
| 303 | Taking out unserviceable plug top of any description and supply and fix new plug top 3 pin 5 Amps single phase 230 volts complete all as specified and as directed. |
| 304 | Disconnect and remove unserviceable copper cable of any description and supply and connect new PVC insulated and PVC round sheathed 3 core, 1.5 Sqmm Copper conductor cable, heavy duty, 1100 Volts grade all as specified and as directed. |
| 305 | Disconnect and remove unserviceable copper cable of any description and supply and connect new PVC insulated and PVC round sheathed 3 core, 2.5 Sqmm Copper conductor cable, heavy duty, 1100 Volts grade all as specified and as directed. |
| 306 | Disconnect and remove unserviceable electronic voltage stabilizer of any description and supply and fix automatic electronic voltage stabilizer of capacity 5.0 KVA having features such as Intelligent time Delay system, Low and High Voltage Cut-off Protection, latest IC Technology to protect from power fluctuations, Thermal over load protection, wide input variation between 170V to 270V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% and of following capacity suitable for Water cooler/ Refrigerator/ Air Conditioner, etc. complete all as specified and as directed. |
| 307 | Disconnect and remove unserviceable electronic voltage stabilizer of any description and supply and fix automatic electronic voltage stabilizer of capacity 5.0 KVA having features such as Intelligent time Delay system, Low and High Voltage Cut-off Protection, latest IC Technology to protect from power fluctuations, Thermal over load protection, wide input variation between 90V to 300V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% and of following capacity suitable for Water cooler/ Refrigerator/ Air Conditioner, etc. complete all as specified and as directed. |
| 308 | Disconnect and remove unserviceable electronic voltage stabilizer of any description and supply and fix automatic electronic voltage stabilizer of capacity 4.0 KVA having features such as Intelligent time Delay system, Low and High Voltage Cut-off Protection, latest IC Technology to protect from power fluctuations, Thermal over load protection, wide input variation between 170V to 270V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% and of following capacity suitable for Water cooler/ Refrigerator/ Air Conditioner, etc. complete all as specified and as directed. |
| 309 | Disconnect and remove unserviceable electronic voltage stabilizer of any description and supply and fix automatic electronic voltage stabilizer of capacity 4.0 KVA having features such as Intelligent time Delay system, Low and High Voltage Cut-off Protection, latest IC Technology to protect from power fluctuations, Thermal over load protection, wide input variation between 90V to 300V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% and of following capacity suitable for Water cooler/ Refrigerator/ Air Conditioner, etc. complete all as specified and as directed. |
| 310 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with BLDC motor. complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender