Tender For Preventing/Corrective Maintenance Of Cooling Appliances, Earthing, Stand By Diesel Gen -Sets & Rain Water Harvesting And Existing External Water Pipelines And Other Allied Works At Various Location And Maintenance Of Street Light Poles, St
Tender Overview
Project Description
Tender for Preventing/Corrective Maintenance Of Cooling Appliances, Earthing, Stand By Diesel Gen -Sets & Rain Water Harvesting And Existing External Water Pipelines And Other Allied Works At Various Location And Maintenance Of Street Light Poles, Street Light Fittings, Timers, Junction Boxes And Other Connected Misc E/M Works At 3U Det & Cleaning Of Ug Sumps, Overhead Reservoirs And Allied Works At 3U Det Under Ge C Bell Bay
BOQ
| Sl. No. | Item Description |
| 1 | M & L for Servicing of Split type air conditioner in citu (Split type air conditioner comprises wiith out door and indoor unit complete) of capacity 1.5 TR of any make and any type cleaning of outdoor condenser coil with water pressure pump and indoor unit coil cleaning by proper bresh and checking of electrical circuit and replacement of defective electric blower fan motor,over load protector,relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning complete all as specified and directed. |
| 2 | Description all as per Srl item No 1.00 above but, capacity 2 TR complete all as specified and directed. |
| 3 | Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2 x 4.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete as specified and directed. |
| 4 | Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 4 x 6.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete all as specified and directed. |
| 5 | M&L for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB including removal old unsv one complete all as specified . |
| 6 | M&L for Modular AC BOX with a two pin and earth plug and socket complete with one single pole MCB including removal old unsv one complete all as specified . |
| 7 | M&L for AC plug top complete all as specified and directed. |
| 8 | S & F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and directed. |
| 9 | Material & labour for filling up & charging of R - 22/ R-32/ R-410 refrigerant or any type of refrigerant gas suitable to the existing AC unit as per site requirement for window/spilt type air conditioner of capacity 1.5TR, refrigerator and water cooler of capacity 80/40 litres after completion of leak testing of complete system and making good by bracing complete all as specified and directed. |
| 10 | M&L for Brazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, as directed and testing commissioning including taking down & refixing of out door unit in same or new location complete all as specified and directed. |
| 11 | S&F electric blower fan motor of split AC 230 volt 1340 RPM single shaft with ball bearing for any make split AC 1/1.5/2.0 Ton capacity complete all as specified and directed. |
| 12 | S&F outdoor unit fan motor 1/20 HP 230 Volt Split AC of capacity 1.5 ton complete all as specified and directed. |
| 13 | S&F swing motor of same quality and charecteristics suitable for any make of AC 1/1.5 / 2.0 Ton split / window type complete all as specified and directed. |
| 14 | S&F overload protector for split type AC of capacity 1.5 ton carrier make complete all as specified and directed. |
| 15 | S&F running capacitor 35/45/50/55 MFD and complete all as specified and directed. |
| 16 | S&F starting capacitor 100/120 MFD complete and complete all as specified and directed. |
| 17 | S&F outdoor Stand for mounting of existing outdoor unit including anchor fastners of suitable size & model complete all as specified & directed |
| 18 | S&F in repairs new outdoor unit for 1.5 TR capacity Split AC working with non CFC complete set all as specified and directed. |
| 19 | S&F hermetically sealed 1.5 TR compressor of same make as that of the existing for split AC with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed f |
| 20 | S & F for thermostat switch of any make of split AC 1.5 ton capacity including removal of old existing unsv one complete all as specified and directed. |
| 21 | S & F for PCB (Printed circuit board) of normal unit suitable for existing 1.5 ton capacity split AC including removal of old existing unsv one complete all as specified and directed. |
| 22 | S & F for PCB (Printed circuit board) of inverter type unit suitable for existing 1.5 ton capacity split AC including removal of old existing unsv one complete all as specified and directed. |
| 23 | S & F for copper tubing of 3/8\\" size sizes for suction / discharge line of any make split AC of capacity 1.5 ton with rubber insulation of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed. |
| 24 | Description all as per Srl item No 23.00 here-in above but, 5/8” size complete all as specified and directed. |
| 25 | Description all as per Srl item No 23.00 here-in above but, 1/4” size complete all as specified and directed. |
| 26 | Description all as per Srl item No 23.00 here-in above but, 1/2” size complete all as specified and directed. |
| 27 | S & F in repairs for fan motor of indoor unit split type air conditioner 1.5 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase complete all as specified and directed. |
| 28 | Supply only universal remote suitable for the existing model AC's including 02 Nos of batteries complete all as directed |
| 29 | S & F for flexible PVC pipe 20 mm dia drain pipe from indoor unit including removal of old existing unsv one complete all as specified and directed. |
| 30 | S & F ODU fan blade for AC including necessary fittings as required complete all as specified and directed |
| 31 | S&F Out door unit condensor copper coil 1.5 TR / 2TR including necessary fittings as required complete all as specified and directed |
| 32 | S&F Out door unit condensor copper coil 1.5 TR / 2TR inverter type including necessary fittings as required complete all as specified and directed |
| 33 | S&F Single pole contactor for Outdoor Units including necessary fittings as required complete all as specified and directed |
| 34 | S&F Coil sensor & frosting sensor for indoor units including necessary fittings as required complete all as specified and directed |
| 35 | M&L for vinyl label of standard size 4x6 cm of MES Number fix on cooling appliances complete all as specified and directed |
| 36 | Supply, installation, testing and commissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA all as specified and directed by Engineer-in-Charge. |
| 37 | M & L for removing and shifting and re install of split type AC 1.5TR / 2TR from old location to new location including all types of necessary fittings and fabrication work as required while shifting and replacement of old damaged minor parts with the new one all as specified and directed by Engineer-in-Charge. |
| 38 | M & L for insulation on copper pipe complete all as specified and as directed |
| 39 | M&L for earthing complete with steel earth plate electrode 60 × 60 cm × 3.15 mm thick electrode burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with 4 mm GI wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1, using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick Cl cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade GI pipe for watering, 40 mm dia light grade Gl pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified and indicated including testing on completion including retrieving of old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed by Engineer-in-Charge. NOTE : - (i). Earthing strip GI/copper upto 7.5m will be measured and paid under this item only. (ii). The earth chamber shall be constructed 50 cm away from the edge of earth pit and the cost of the same is deemed to be included in rate quoted for above item. |
| 40 | M&L for earthing complete with steel earth plate electrode 60 × 60 cm × 3.15 mm thick electrode burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with 25 x 4 mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1, using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick Cl cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade GI pipe for watering, 40 mm dia light grade Gl pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified and indicated including testing on completion including retrieving of old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed by Engineer-in-Charge. NOTE : - (i). Earthing strip GI/copper upto 7.5m will be measured and paid under this item only. (ii). The earth chamber shall be constructed 50 cm away from the edge of earth pit and the cost of the same is deemed to be included in rate quoted for above item. |
| 41 | M&L for earthing complete with hot dip galvanized steel pipe in pipe electrode, outer pipe 88mm dia medium grade and inner pipe 55 mm dia including testing, 3 mtr long and having 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.3 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32x6 mm strip with minimum two Nos of GI nut bolts and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 kg bags of carbon based earthing compound. The resistance of the compound should be less than 0.1 Ohm. The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between 7 - 9. Connected to the earthing test point, Fiber reinforced plastic pit not less than 300x300 mm with pit cover, including necessary returning filling & removal of extra soil , to achieve earth resistance value less than 2 Ohms including testing complete all as specified. NOTE:- If the desired result not obtained after testing the contractor should do re-eathing without any extra cost. |
| 42 | Taking down and S&F in repalcement GI strip 25 mm x 4 mm to be burried in ground for loop earthing and ground grid including excavation and earthwork in any type of soil complete all as specified and directed.Note:- GI Strip along wall / Columns /Beams shall be installed on suitable insulators and MS clips all as required. |
| 43 | Material and labour for Gl earth Wire 4 mm as main earth lead along wall or buried in ground/Wall/ ceiling etc, complete all as specified and directed. |
| 44 | Supply and lay 40 mm dia, GI pipe, light grade, burried in trenches/or to be fixed on wall as earth continuity protection in repairs including necessary excavation and earth work in hard / dense soil, returning & filling in, watering and well ramming, removal of surplus soil to a distance not exc 50 mtrs complete all as specified and directed |
| 45 | M&L for Sub main wiring surface / concealed with two single core PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, FRLS cable drawn in surface / concealed conduit, including PVC conduit medium grade, heavy duty, ISI marked not less than 20 mm dia, in any type of wall, roof, etc, with all connected fittings , including PVC insulated unsheathed Two run of 4.0 Sqmm cable and one run of 4.0 sqmm earth wire with multistranded copper conductor of green colour as continuous earth conductor cable connected to earth dolly and make good to match with the existing surfaces after completion all as specified. Note:- (i) Cutting in chases and pointed in brick wall/stone wall or any type of surface where required for concealing the conduit shall be done by contractor without any extra cost. (ii) Two runs of 4 Sqmm cable with one run of 04 Sqmm earth wire along with PVC conduit shall be measured as one RM |
| 46 | M&L for Sub main wiring surface / concealed with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLS cable drawn in surface / concealed conduit, including PVC conduit medium grade, heavy duty, ISI marked not less than 20 mm dia, in any type of wall, roof, etc, with all connected fittings , including PVC insulated unsheathed Two run of 6.0 Sqmm cable and one run of 6.0 sqmm earth wire with multistranded copper conductor of green colour as continuous earth conductor cable connected to earth dolly and make good to match with the existing surfaces after completion all as specified. Note:- (i) Cutting in chases and pointed in brick wall/stone wall or any type of surface where required for concealing the conduit shall be done by contractor without any extra cost. (ii) Two runs of 4 Sqmm cable with one run of 04 Sqmm earth wire along with PVC conduit shall be measured as one RM |
| 47 | S&F DB Box, in sheet metal enclosure MCB DB 04 way TPN Double door, factory made suitable for MCB TPN as incomer and suitable for SP/TP in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, 415 volts, including blanking plate as required etc. DB box to be flushed and fixed in wall complete and making all electrical connections complete all as specified and directed by the Engr-in-Charge. |
| 48 | S&F MCB TPN 32 / 40 Amps, 415V, 10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing all as specified and directed. |
| 49 | S & F sheet metal enclosure for MCB DB Box, SPN, 240 Volts, 100 amps rated busbar, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including fixing the DB box flushed in wall of any type and making good the distrubed surface to match as the existing finishes all as specified and directed by Engr-in-charge |
| 50 | S&F MCB SPN 32 Amps 240V, 10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing all as specified and directed. |
| 51 | S&F MCB SP 6 to 32 Amps 240V, 10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs of suitable size for incoming and outgoing all as specified and directed. |
| 52 | Supply & Laying 2 Core x 6 Sqmm XLPE, insulated, armoured, heavy duty, electric cable with stranded aluminium conductors, 1100 volts grade, laid in tranches/fixing on wall/poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, including taking down existing unserviceable cable from trenches / GI protections pipes, complete all as specified and as directed Note:- Excavation, earthwork, GI pipe, etc shall be measured and paid extra under respective items. |
| 53 | Description all as per Srl item No 52.00 here-in above but, 2 core x 10 Sqmm |
| 54 | Description all as per Srl item No 52.00 here-in above but, 4 core x 10 Sqmm |
| 55 | Taking out old serviceable XLPE LT cable of any size and rerouting or relaying the same complete all as specified and directed. |
| 56 | S&F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having inner dia 40 mm complete terminated up to termination end point complete all as directed by Engr-in-Charge. |
| 57 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge |
| 58 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed by Engineer-in-Charge |
| 59 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge |
| 60 | M&L for road cutting by manually for laying of LT UG cable/Galvanised Iron pipe including making good to distrubed surface after the completion of work with PCC 1:2:4 type B-2 on top including levelling and cambering according to existing road surface, refilling, watering, ramming etc all as specified and as directed. |
| 61 | S&F GI pipe 50mm bore light grade with all fittings laid in trenches/on wall / on poles etc/ for protection complete all as specified and directed. |
| 62 | Taking down LED street light fitting/ LED flood light fitting of any watts and type from any height of pole/walls/high mast of any location and detecting the fault in the fitting by checking the accessories, wiring and refixing the same after repairs & incorporating the faulty spares complete all as directed by Engineer-in-Charge. |
| 63 | Supply only LED Driver suitable for existing upto 30 W LED light fittings complete all as specified and directed. Note for item :Drivers shall be techincally compatible for existing type of fittings & frame size shall be matched to existing fittings. |
| 64 | Description all as per item No.63.00 above but, Driver suitable for more than 30 W and upto 60 W LED light Fittings |
| 65 | Description all as per item No.63.00 but, Driver suitable for more than 90 W and upto 150 W LED light Fittings |
| 66 | Supply, installation & testing LED street light Luminaries compressing pressure, die cast housing for better aesthetics and thermal management. Comprises of extruded aluminium housing with pre-wired gear tray with LED’s & drive, heat resistant flat glass suitable gasketed for IP 66 protection, high grade power coating and fitted with toughened glass with high power LED’s of not less than 60 watt incl surge protection complete including taking down existing fittings all as specified and directed. |
| 67 | Supply and fixing post top lantern LED type 35 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 66 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 68 | S&F in replacement of GI Pipe bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary arrangement for fixing the existing street light fitting on pole / wall with two sets of clamps made out of flat iron 32 x 6mm, bolts, nuts and washers including applying two coats of aluminium paint over on coat of red oxide zinc chrome primer complete all as directed by Engr-in-Charge. |
| 69 | M & L for PVC cable with copper conductor 1.5 sqmm, 2 core, 1100 volts grade multistranded for connecting from existing junction box to street light fitting including PVC conduit complete all as specified and directed |
| 70 | Supply and fixing of PVC Junction box of size 140 x 140 x 95 mm, pole mounting hinged type including necessary clamp for MCB mounting and mounting of Box on pole/pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as directed by Engr-in-charge. |
| 71 | Supply and fixing of PVC Junction box of size 270 x 225 x 135 mm, pole mounting hinged type including necessary clamp for MCB mounting and mounting of Box on pole/pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as directed by Engr-in-charge. |
| 72 | M&L for cleaning LT/Street light poles of 8.5/9.0 mtrs long and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of synthetic enamel weather proof emulsion distemper paint and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engineer-in-Charge. |
| 73 | Supply & Fix MCB TPN, 32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002, integrated label holder, sliding bottom clamp, IP 20 protected terminal, sliding shutters, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. |
| 74 | Description all as per item No.73.00, but MCB SPN 32 A, 240V |
| 75 | Description all as per item No.73.00, but MCB SP 6-32 A, 240V |
| 76 | M&L for General Servicing of DG set 320 KVA Capacity at run of 200 hours or 2 months which ever comes first (twice in Contract period based on condition ) comprising of following jobs i/c Transportation, Labour charges & minor material required for servicing etc. as reqd complete all as specified and directed.(i) Cleaning & greasing of the parts.(ii) Tappet setting as per standard(iii) Fan belt, tensioner pulley and lever adjustments.(iv) Tightening of all the nuts, bolts and clamps.(v) Testing & checking of AC & DC Wiring.(vi) Self & Charging Alternator cleaning and testing, checking of working & minor fault removal.(vii) Checking of Supply & return fuel pipes from fuel tank to engine.(viii) Checking of FIP timing by Fuel cut off method. |
| 77 | Description all as per item No.76.00, but DG set 140 KVA Capacity |
| 78 | Description all as per item No.76.00, but DG set 125 KVA Capacity |
| 79 | Description all as per item No.76.00, but DG set upto 62.5 KVA Capacity |
| 80 | Disconnecting, removing and dismantling radiator assembly from the DG set 320 KVA Capacity and descaling the radiator thoroughly with using suitable any other chemical solvent agent as approved by the Engineer-in-Charge, stopping of leakeage at place to copper cores and tubes by brazing scrapping the existing Oil paint, dusting and painting the radiator with enamelled paint etc re-installing and commissioning all as directed by Engineer-in-charge |
| 81 | Description all as per item No.80.00, but DG set 140 KVA Capacity |
| 82 | Description all as per item No.80.00, but DG set 125 KVA Capacity |
| 83 | Description all as per item No.80.00, but DG set upto 62.5 KVA Capacity |
| 84 | M&L for repair/ maintenanance opening of AMF Panel, Cleaning of dust using blower & cleaning agents. Checking/Detecting, Removal of Faults, Re-wiring of old u/s wiring & Testing of Control Wiring complete as reqd for diesel generating set of from 25 KVA to 125 KVA capacity three phase 415 Volts, 50 HZ AC with all standard features, safeties etc., complete as directed and specified by engineer in charge. |
| 85 | M&L for removing defective AVR from Alternator and replacing with new AVR upto 125 KVA DG sets Make as per existing all as specified and directed by Engineer -in-Charge |
| 86 | Description all as per item No.85.00 above but, Alternator capacity upto 320 KVA Capacity all as specified and directed by Engineer -in-Charge |
| 87 | Supply & fixing diesel filter suitable for capacity upto 125 KVA DG set Primery & secondary set complete all as specified and directed. |
| 88 | Description all as per item No.87.00 above but, capacity upto 320 KVA primary and secondary set. |
| 89 | Supply & fixing Engine oil filter suitable for capacity of DG sets upto 125 KVA complete all as specified and directed. |
| 90 | Description all as per item No. 89.00 above but, capacity upto 320 KVA |
| 91 | Supply and fixing in repair / replace of Air cleaner elements inner and outer for DG sets upto 125 KVA complete all as specified and directed. |
| 92 | Description all as per item No.91.00 above but, capacity upto 320 KVA |
| 93 | Material & Labour for Half engine opening and rectify the fault , Replacement of water liner and checking of Coolent/ water leakage in side engine of DG Set upto 125 KVA such as works of Engine piston, cylinder head, lathe works including replacement of bearing bush, turbo charger, connecting rod bolt, piston ring set, cylinder liner, intermediate ring, bush for injector etc and replacement of other worn out or damaged items as required all as specified and as directed by Engineer-in-Charge. |
| 94 | Material & Labour for Half engine opening and rectify the fault , Replacement of water liner and checking of Coolent/ water leakage in side engine of DG Set upto 320 KVA such as works of Engine piston, cylinder head, lathe works including replacement of bearing bush, turbo charger, connecting rod bolt, piston ring set, cylinder liner, intermediate ring, bush for injector etc and replacement of other worn out or damaged items as required all as specified and as directed by Engineer-in-Charge. |
| 95 | Material & Labour for Alternator Winding of DG Set upto 62.5 KVA and replacement of other worn out or damaged items as required all as specified and as directed by Engineer-in-Charge. |
| 96 | Supply and fixing in repair of Water Pump of Radiator suitable for DG set Radiator up to 125 KVA complete all as specified and directed. |
| 97 | Description all as per item No.96.00 above, capacity upto 320 KVA |
| 98 | M&L for Removal & replacement of flywheel gear ring suitable for upto 125 KVA DG set connection & testingcomplete all as specified and directed. |
| 99 | Description all as per item No.98.00 above but, capacity upto 320 KVA |
| 100 | M&L for Removal & replacement of thermostat suitable for upto 125 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge. |
| 101 | Description all as per item No.100.00 above capacity upto 320 KVA |
| 102 | Supply and fixing of copper terminal end suitable for batteries of capacity 12V 180AH complete all as specified and directed by Engineer-in-Charge. |
| 103 | Supply and fixing in repair for all type of hose pipe with clamps , over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings suitable for DG set upto 125 KVA all as directed by Engineer-in-Charge. |
| 104 | Description all as per item No.103.00 above but, capacity upto 320 KVA |
| 105 | Supply & Fixing in repair of Battary Charger 12V DC, 5 Amp of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Rectifier Unit etc suitable for smoothing functioning of DG set as required on site complete all as directed and specified by engineer in charge. |
| 106 | Description all as per item No.105.00 above but, capacity Battary Charger 24V DC, 10 Amp complete all as directed and specified by Engineer in charge. |
| 107 | Supply only distil water for top up in Batteries |
| 108 | Supply only Hand crank fuel transfer pump Drum Rotary hand pump for DHPPfrom barrel to DG set |
| 109 | Supply only electrolyte battery solution (Dilute sulphuric acid have specific gravity 1210 degree) in 10 litrs sealed gallon packing complete all as specified and directed by Engineer-in-Charge. |
| 110 | Supply and filling of Premixed coolent. |
| 111 | Supply and filling in sump/topping up engine oil, multi grade 20w40 in engine or relpacement of engine oil. |
| 112 | Supply & Fixing in repair of DC 12V Stop Solenoid suitable for DG Set complete all as directed and specified by engineer in charge. |
| 113 | Supply & Fixing in repair of DC 24V Self Solenoid Coil suitable for DG Set complete all as directed and specified by engineer in charge. |
| 114 | Supply and replacement of Bty 12 Volt 100 AH suitable DG set complete all as directed and specified by engineer in charge. |
| 115 | Supply and replacement of Bty 12 Volt 180 AH suitable DG set complete all as directed and specified by engineer in charge. |
| 116 | M&L for repairing of self starter of DG set capacity 12 Volts including transporting upto workshop to carry out necessary replacement of burnt copper winding with new copper winding/ coil of existing gauge from rotor and stator coil, cleaning of slots, dryings varnishing and proper insulating to winding complete all as specified and directed. |
| 117 | Description all as per item No.116.00 above but capacity 24 Volts complete all as directed and specified by engineer in charge. |
| 118 | Supply, fixing and testing for smoothing fuctioning Fan Belt suitable for DG set up to 125 KVA complete all as specified and directed. |
| 119 | Description all as per item No.118.00 above but capacity upto 320 KVA complete all as directed and specified by engineer in charge. |
| 120 | Material and Labour for replacement of crank shaft of DG set having all as directed by Engineer-in-Charge. |
| 121 | Supply & Lay XLPE 3.5 Core x 50 Sqmm, insulated, armoured, heavy duty, electric cable with stranded aluminium conductors, 1100 volts grade, laid in tranches/fixing on wall/poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, including taking down existing unserviceable cable from trenches / GI protections pipes, complete all as specified and as directed |
| 122 | Description all as per Srl item No 121.00 here-in above but of size, 3.5 Core x 35 Sqmm |
| 123 | S&F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having inner dia 40 mm complete terminated up to termination end point complete all as directed by Engr-in-Charge. |
| 124 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge |
| 125 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed by Engineer-in-Charge |
| 126 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge |
| 127 | Taking down the existing Unserviceable panel board ON/Off push button and replaced with new push button complete all as specified and directed by the Enginner-in-charge |
| 128 | Taking down the existing defective injector and fuel injection pump (FIP) for up to 125 KVA Capacity DG Set installed at various installation and replacement of work out spares like delivery valves, Nozzles, bearings, fly weight, packing kit, and copper washer kit and recalibration of FIP and refixing in same position and testing of full load checking of pressure complete all as specified and directed by the Engineer-in-charge |
| 129 | Description all as per Srl item No 128.00 here-in above but 320 KVA Capacity DG set |
| 130 | Taking down the existing defective DC Ammeter and volt meter from the panel and replaced with new Combined DC Ammeter and Volt meter including necessary wiring and wiring material complete all as specified and directed by the Engineer-in-charge |
| 131 | Taking down the existing defective/damaged Oil flexible ( Metal mesh/rubber) hose and replaced with new Oil flexible hose for upto 160 KVA capacity Genset including replacement of connector etc., complete all as specified and directed by the Engineer-in-charge |
| 132 | M&L for attend Complaints and rectify issue of any Dgset in panel wiring , engine, alternator including replacement of parts complete all as specified and directed by the Engineer-in-charge |
| 133 | S & F in replacement sheet metal enclosure verticle MCB DB TPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified |
| 134 | Supply & Fixing in MCCB 63 Amp complete all as directed and specified by engineer in charge. |
| 135 | Supply & Fixing in repair of Four Pole Contactor, 415V AC, 2 NO+NC, 160 Amp complete all as directed |
| 136 | Description all as per Srl item No 135.00 here-in above but upto 100 Amp complete all as directed and specified |
| 137 | M&L for Dewatering of existing old water by using pumps from RCC water main collection sump reservoir (inside) of Dia upto 40 m and Depth upto 7m complete all as specified and directed Note:- (i) Work is to be executed at upto 18 to 25m height/depth. (ii) All necessary T&P, labour and materials shall be arranged by the contractor. |
| 138 | Description all as per Srl item No 137.00 here-in above but Over Head Tank above ground level of capacity upto 50,000 litres (OHT) |
| 139 | Description all as per Srl item No 137.00 here-in above but Underground sump of capacity upto 25,000 litres |
| 140 | Description all as per Srl item No 137.00 here-in above but Underground sump of capacity more than 25,000 liters upto 80,000 litres |
| 141 | M&L for Alternate water supply arrangement during cleaning of tank with the help of portable water tanks of sufficient qty by collecting water from the sump ( cleaning) or by help of water tanks from civil supply including pumps and necessary PVC moulded pipe food grade till completion of cleaning work of tank complete all as specified and directed at site Note:- (i) Work is to be executed at upto 18 to 25m height/depth. (ii) All necessary T&P, labour and materials shall be arranged by the contractor. |
| 142 | M&L for cleaning of RCC water main collection sump reservoir (inside) of Dia upto 40 m and Depth upto 7m the complete tank, removing the sediments settled at the bottom of tank, scraping with the help of shovels, hard brushes and physical cleaning of tanks (Reservoir) by de-scaling/brooming silt and sludge and other deposits from inner side (bottom of dome), collecting and taking them out with the help of manual labour and depositing at a distance notless than 50m Note:- (i) Work is to be executed at upto 18 to 25m height/depth. (ii) All necessary T&P, labour and materials shall be arranged by the contractor. |
| 143 | Description all as per Srl item No 142.00 here-in above but Over Head Tank above ground level of capacity upto 50,000 litres (OHT) |
| 144 | Description all as per Srl item No 142.00 here-in above but Underground sump of capacity upto 25,000 litres |
| 145 | Description all as per Srl item No 142.00 here-in above but Underground sump of capacity more than 25,000 liters upto 80,000 litres |
| 146 | M&L for Cleaing of RCC water main collection sump reservoir (inside) of Dia upto 40 m and Depth upto 7m making the tank clean and washing properly with bleaching powder mixed with water (1:10) and again lime wash complete all as specified and directed by Engr -in- Charge. |
| 147 | Description all as per Srl item No 146.00 here-in above but Over Head Tank above ground level of capacity upto 50,000 litres (OHT) |
| 148 | Description all as per Srl item No 146.00 here-in above but Underground sump of capacity upto 25,000 litres |
| 149 | Description all as per Srl item No 146.00 here-in above but Underground sump of capacity more than 25,000 liters upto 80,000 litres |
| 150 | M&L for applying two coats of Anti Fungal rubber Paint (white in colour) over one coat of primer at internal RCC/PCC walls of RCC water main collection sump reservoir (inside) of Dia upto 40 m and Depth upto 7m |
| 151 | Description all as per Srl item No 150.00 here-in above but Over Head Tank above ground level of capacity upto 50,000 litres (OHT) |
| 152 | Description all as per Srl item No 150.00 here-in above but Underground sump of capacity upto 25,000 litres |
| 153 | Description all as per Srl item No 150.00 here-in above but Underground sump of capacity more than 25,000 liters upto 80,000 litres |
| 154 | Material & Labour for applying on internal & external walls of RCC water main collection sump reservoir (inside) of Dia upto 40 m and Depth upto 7m Two or more coats of 100% Premium acrylic emulsion rubber paint having VOC less than 50 gm/litre Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.complete all as specified and directed |
| 155 | Description all as per Srl item No 154.00 here-in above but Over Head Tank above ground level of capacity upto 50,000 litres (OHT) |
| 156 | Description all as per Srl item No 154.00 here-in above but Underground sump of capacity upto 25,000 litres |
| 157 | Description all as per Srl item No 154.00 here-in above but Underground sump of capacity more than 25,000 liters upto 80,000 litres |
| 158 | M&L for writing the date of cleaning, and capacity of tank in paint (white letters on black back ground) by the help of paintercomplete all as specified and directed by Engr-in- Charge. |
| 159 | M&L for removing of any vegetation growth on and around the tank complete all as specified and directed by Engr-in- Charge. Please Enable Macros to View BoQ information |
| 160 | M&L for removing of any vegetation growth on and around the tank complete all as specified and directed by Engr-in- Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender