Tender For Provn Of Facade Lighting For Vyas Library At Nda Khadakwasla (Spl Wk)
Tender Value
38.65 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
8 days left
EMD
77500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Facade Lighting For Vyas Library At Nda Khadakwasla (Spl Wk)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-Oct-2026 | CORRIGENDUM | Other | 07-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fix RGB/RGBW surface mounted Flood luminaire 50 Watt narrow/med beam , angle as per site requirements (- 10°; 25°; 30°; 40°; 60°; 10°x30°; 15°x30°; 15°x60°; 15°x45°) suitable for outdoor applications of Facade Lighting. Complete with in built driver or external driver with IP 67 protection, Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement. Power consumption should be 50W+ 10% at steady state full intensity, Luminaire luminous flux range of 2500 Lumens,THD<10%. Power factor of complete luminaire 0.95 at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should have in built DMX chip and compatible to DMX512 control protocol. The luminaire should have powder coating aluminium housing. Ingress Protection IP 66 Impact resistance level IK 07. Operating Temperature: -10°C to +50°C, Operating voltage range 140V-270V with 10KV surge protection ,SCDM<5, Life class of 50000burning hours @l70 B50 Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate , Should have its Inhouse NABL Accredited Testing Lab with in its own Manufacturing Unit, all technical Parameters should comply IS 10322 Standards complete all as specified and directed |
| 2 | Supply and erecting of RGBW / DMX Linear light fitting 40W - IP66, IK07, having cast aluminum body with PC lens, suitable for DMX 512 Protocol, with built in / external driver having system output of min - 2400 lumens, With LED driver, THD < 10%, CCT RGBW, pf - > 0.9, Operating voltage range - 140V - 270V, with 10KV surge protection, SCDM <5, Life class of 50000 BH @ L70 B50, 3 year warranty including driver, Beam Angle requirements as per site selection - 10°; 25°; 40°; 18°X35°, as per Havells cat part COLORLINE 40W DMX 25 deg. complete all as specified and directed |
| 3 | Supply and fix outdoor architecural RGBW/DMX Neon Flex Light strip for outdoor facade lighting,1Mtr roll, with Inbuilt decoder, with Silicon cover, In-built DMX control option for RGBW products to provide design freedom with highly dynamic architectural scene, Operating temperature: - 20°C to 50°C, corrosive gases and UV., Suitable for operating voltage range - 24V DC, Life class of 50000 BH @ L70 B50 Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement. Power consumption should be 15w/m to 18W/Mtr at steady state full intensity complete all as specified and directed |
| 4 | S & F Aluminium Profile 19 mm wide for Neob Flex Light high Grade on wall complete all as specified and directed |
| 5 | S& F LED Driver AC100~200V input, DC24V output, 250W, constant voltage power supply IP Rating : IP67 housed in PVC junction Box complete all as specified and directed |
| 6 | Supply & fix DMX Controller 2X512, Stand Alone DMX 512 controller to more advanced moving and color mixing luminaires The dual channel DMX 512 controller comes with a variety of features including RTC/calendar, Ethernet facilities, dry contact port triggering, multi-zone programming and SD memory card. The lighting levels, colors and effects can be programmed from a PC using the DMX software, Type C USB port : 5VDC /0.6 A ,Power Consumption <10W ,IP20 complete all as specified and directed |
| 7 | Supply and fix DMX Splitter Individual optical isolation per port. Housing types: Box. Min. 08 Port DMX Outputs per universe DMX line termination complete all as specified and directed complete all as specified and directed |
| 8 | Supply & Fix DMX Booster - Individual optical isolation per port. Housing types: Box. Min. 08 Port DMX Outputs per universe DMX line termination complete all as specified and directed complete all as specified and directed |
| 9 | Supply & fix DMX extension cable one metre length with male& female IP 67 connector ont complete all as specified and directed |
| 10 | Supply & fix water proof (IP 67 rating) Male-Female Connector set (Same as Light Connectors) for connecting DMX cables. complete all as specified and directed |
| 11 | Supply and fix 25 mm dia. PVC conduit for DMX cable fixed on Saddle Clips and conduit accessories complete all as specified and directed |
| 12 | Supply & fix XLR Connector Cable Male to Female with accessories complete all as specified and directed |
| 13 | Supply & fix Splitter box for Both Sites & accessories complete all as specified and directed |
| 14 | Supply MCB DB TPN 4 way 415V AC double door complete all as specified and directed |
| 15 | Supply and fixing miniature circuit breaker (MCB) 6 to 32A,240V, 10 KA 'C' curve of single poles and current Complete with connection testing and commissioning complete all as specified and directed |
| 16 | Supply and fixing miniature circuit breaker (MCB) TPN 40 to 100A 415V 10KA 'C \\" curve of following poles and current carrying capacity in the DB complete with connection testing and commissioning. complete all as specified and directed |
| 17 | Programming Charges for DMX control system and Installation & Guiding Charges including site visit and other work complete all as specified and directed |
| 18 | Excavation in trenches in hard/dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed. |
| 19 | Returning and filling in, including spreading and well ramming in layers n exc 25 cm complete all as specified and directed |
| 20 | Removing excavated surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5 mtr above starting point complete all as specified and directed. |
| 21 | Supply and laying 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection complete all as specified and directed by Engr-In-Charge Make : as per sample approved complete all as specified and directed |
| 22 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium multistrand conductor, 1100 volts grade, cross sectinal area 16 sqmm 4 core complete all as specified and directed Please Enable Macros to View BoQ information |
| 23 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium multistrand conductor, 1100 volts grade, cross sectinal area 16 sqmm 4 core complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Nov 07, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender