Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #58130537

Tender For Repair/Maint To Lt Distribution System At 222 Asc Bn, Fpd And Other Locations Under Ge(U) Udh Ur.

Issued by Statutory Bodies & Commissions/Committees · Reasi, Jammu and Kashmir
Tender Value
49 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
9 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint To Lt Distribution System At 222 Asc Bn, Fpd And Other Locations Under Ge(U) Udh Ur.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 28-Oct-2026 BOQ REVISED BOQ 09-Nov-2026

BOQ

Name of Work:- Repair/maint to LT Distribution System at 222 ASC Bn, FPD and other locations under GE(U) Udh ur.
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work:Repair/maint to LT Distribution System at 222 ASC Bn, FPD and other locations under GE(U) Udhampur. Contract No: GE/U-110/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2Supply, laying, jointing & testing in replacement XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 4 core laind in trenches or passing through pipe or fixed on poles complete all as specified and directed by Engr-in-Charge.
3Description all as per serial item No 1.00 here-in-before but of size 16 Sqmm 4 core.
4Description all as per serial item No 1.00 here-in-before but of size 25 Sqmm 4 core.
5Description all as per serial item No 1.00 here-in-before but of size 35 Sqmm 3.5 core.
6Description all as per serial item No 1.00 here-in-before but of size 50 Sqmm 3.5 core.
7Description all as per serial item No 1.00 here-in-before but of size 70 Sqmm 3.5 core.
8Description all as per serial item No 1.00 here-in-before but of size 95 Sqmm 3.5 core.
9Description all as per serial item No 1.00 here-in-before but of size 120 Sqmm 3.5 core.
10Description all as per serial item No 1.00 here-in-before but of size 150 Sqmm 3.5 core.
11Description all as per serial item No 1.00 here-in-before but of size 240 Sqmm 3.5 core.
12Description all as per serial item No 1.00 here-in-before but of size 300 Sqmm 3.5 core.
13Description all as per serial item No 1.00 here-in-before but of size 400 Sqmm 3.5 core.
14Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed by engineer in charge.
15Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge
16Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.
17Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
18S&F double walled corrugated (DWC) pipe of size 180 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT/HT cable in trench/under ground complete all as spd and directed. Make: REX/Tirupati Plastomatics Pvt Ltd
19S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT/HT cable in trench/under ground complete all as spd and directed. Make: REX/Tirupati Plastomatics Pvt Ltd
20S&F double walled corrugated (DWC) pipe of size 90 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT/HT cable in trench/under ground complete all as spd and directed. Make: REX/Tirupati Plastomatics Pvt Ltd
21S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT/HT cable in trench/under ground complete all as spd and directed. Make: REX/Tirupati Plastomatics Pvt Ltd
22M&L for cement concreate 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level complete all as specified and directed by Engr-in-Charge.
23M&L for PCC 1:4:8 type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc complete all as specified and directed by Engr-in-Charge.
24Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe complete all as specified and directed by Engineer-in-Charge.
25Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 80 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe, complete all as specified and directed by Engineer-in-Charge.
26Dismantling of unserviceable steel tubular pole swaged pole/PCC pole including PCC complete with acessories complete all as specified and directed by Engr-in-Charge.
27S&F in replacement erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engr-in-Charge.Note: - (a) Excavation and Earth Work, PCC in foundation shall be measured and paid for separately.
28Cleaning the existing exposed surfaces of steel tubular pole of 9.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engr-in-Charge.
29Supply, installation, testing and commissioning in repair of outdoor type,weather proof, LT Panel made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50 x 50 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
30(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 800 amps for Phases neutral - 01 set (b) Phase indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos(c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job(d) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable CT of appropriate ratio. Incoming :-(a) MCCB 4 pole , Ics=100%Icu- 50 KA, 415 Volts, 400 Amps , with thermal adjustable and adjustable magnetic setting with extended terminals -01 No.incoming :-(b) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 200 Amps , with thermal adjustable and adjustable magnetic setting with extended terminals -1 No.(c) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 125 Amps , with thermal adjustable and adjustable magnetic setting with extended terminals -1 No. (d) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and adjustable magnetic setting with extended terminals -1 No. (e) PCC 1:3:6 type C-2 for grouting 4 legs of LT Panel
31All as per item No 28 above but having following capacity for INCOMING(a) MCCB four pole 250 Amps, 36 KA at 415 Volts- 01 No.(b) 500 Amps rated Aluminium bus bar suitable for 3 phase 4 wire system - 01 No.(c) Phase indicating lamp RYB neon type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils OUT GOING(a) MCCB four pole 160 Amps, 25 KA at 415 Volts-01 No(b) MCCB four pole 100 Amps, 25 KA at 415 Volts-01 No(c) MCCB four pole 63Amps, 25 KA at 415 Volts-01 No
32Labour only for re-stretching properly sagged/loose ACSR conductor of any size fixed on LT poles by means of machine method to the permissible limit at different location including tightening of cross arms or D clamps and binding with new binding wire, tightening of jumpers complete all as specified and directed by Engr-in-Charge.Note: - (i) Each line of conductor shall be measured.(ii) Rate including unwinding of old winding wire and rewind with new binding wire after restretching)
33S&F in replacement Shackle type porcelain vitreous white, brown or green insulator of size 75 mm height & 90 mm dia including galvanized mild steel straps of size 31 x 3 mm and bolt of size 12 mm dia, washers and nuts of 75 mm height & 90 mm dia for working pressure 1100 volts grade complete all as specefied and directed by Engr-in-charge.
34S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator 1100 V grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia complete all as specified and directed by Engineer-in-Charge.
35M&L for defect rectification of LT 1.1 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pules, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 11 KV / 1.1 KV complete all as specified and directed by Engineer-in-Charge.
36M & L in replacement for heat shrinkable End joint for PVC/XLPE insulated armoured cable of size upto 50Sqmm 3.5/4 core complete all as specified and directed by Engineer-in-Charge.
37All as per serial item No: 34.00 above but LT cable size of 70 to 150 Sqmm
38All as per serial item No: 34.00 above but LT cable size of 185 to 300 Sqmm
39S&F in replacement Stay assembly complete with acessories as shown in electrical plate no 1 (loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) with 16 mm dia stay rod complete all as specefied and directed by Engr-in-charge including taking down old U/S same items.
40S&F in replacement Galvanized steel wire 4 mm dia for continious earth wire on poles and cradles at road crossing with fixing arrangement complete all as specefied and directed by Engr-in-charge.
41S&F in replacement on LT overhead line separator 3 way complete all as specefied and directed by Engr-in-charge.
42S&F in replacement on LT overhead line separator 4 way complete all as specefied and directed by Engr-in-charge.
43M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20x15cm size complete all as specified and directed by Engr-in-Charge.
44M&L for repairing the existing LT panel/ Feeder Pilller Box/ APFC Panel any type or size by taking proper shutdown from power house and disconnecting and re-connecting cables connection both in coming and outgoing using appropriate size of thimbles, making proper welding, drilling for smooth functioning of panel / feeder door, replacement of unserviceable aluminium bus bar of suitable capacity/size as per existing including bakelite insulators, terminals, base plate, necessary nuts, bolts & washers, locking arrangement complete all as specified and directed by Engr-in-Charge. Note: - Necessary accessories like MCCB/MCB, CT coil, ammeter, voltmeter, indication lamp, selector switch, Proper Loacking Arrangement, Base Frame etc shall be measured and paid separately as supply & fixing under respective item.
45S&F in replacement MCCB four pole 63 Amps,50 Hz with breaking capacity 16KA, Ics = 100% Icu , 415 Volts, Adjustable thermal & Fixed magnetic setting including making all incoming/ outgoing connections complete all as specified and directed by Engineer in Charge.
46Description all as per serial item No 43.00 here-in-before but 100 Amps, 4P, with breaking capacity 16 KA.
47Description all as per serial item No 43.00 here-in-before but 125 Amps with breaking capacity 16 KA.
48Description all as per serial item No 43.00 here-in-before but 160 Amps with breaking capacity 36 KA.
49Description all as per serial item No 43.00 here-in-before but 200 Amps with breaking capacity 36 KA.
50Description all as per serial item No 43.00 here-in-before but 250 Amps with breaking capacity 36 KA.
51Description all as per serial item No 43.00 here-in-before but 315 Amps with breaking capacity 36 KA.
52Description all as per serial item No 43.00 here-in-before but 400 Amps with breaking capacity 36 KA.
53Description all as per serial item No 43.00 here-in-before but 630 Amps with breaking capacity 36 KA.
54S&F in replacement Ampere meter digital type of ratio 0-100 Amp, size 95 Sqmm square type including making incoming/outgoing connections complete all as specified and directed by Engr-in-Charge.
55S&F in replacement Voltmeter digital type of ratio 0-415 volt , size 95 Sqmm square type including making incoming/outgoing connections complete all as specified and directed by Engr-in-Charge.
56M&L in replacement selector switch rotary type including making connections complete all as specified and directed by Engr-in-Charge.
57M&L in replacement Indicator lamp assembly LED type with red/green/blue including making connections complete all as specified and directed by Engr-in-Charge.
58M&L in replacement of Current transformer (CT) ratio 100/5 including making connections complete all as specified and directed by Engr-in-Charge.
59S&F change over switch FP 200 Amps, 415 Volt, 4 pole with enclouser & connecting accessories complete all as specefied and directed by Engr-in-charge.
60S&F change over switch FP 100 Amps, 415 Volt, 4 pole with enclouser & connecting accessories complete all as specefied and directed by Engr-in-charge.
61S&F change over switch FP 63 Amps, 415 Volt, 4 pole with enclouser & connecting accessories complete all as specefied and directed by Engr-in-charge.
62M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board including necesary excavation and earth work complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
63M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanised earth wire 4.0mm dia as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board including necesary excavation and earth work complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
64Supply & fixing in repair replacement for heat shrinkable Three finger breakout for suitable of PVC/XLPE insulated armoured cable in end of cabel of size upto 50Sqmm 3.5/4 core complete all as specified and directed by Engr-in-Charge.
65Description all as per serial item No 64.00 here-in-before but LT cable size of 70 to 150 Sqmm.
66M&L for switchyard gravelling of 15.0 cm (loose thickness) by broken stone of 40 mm size in and around two pole/ four pole structure/ substation complete all as specified and directed by Engr-in-Charge.
67Taking out/dismantling any type of LT Panel by disconnecting the electric connection carefully after taking proper shutdown and removing from the site and stacking complete all as specefied and directed by Engr-in-charge.
68M&L for ACSR conductor of required size for over head lines on poles including streching,tighting of poles insulator with binding wire of sutable size with insulator/streching of ACSR conductor, including taking down all as specified and diected by Engr in charge.Note: Retrived ACSR Conductor will be deposited at EM store yard with own arrangement by Contractor.
69Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 3x95 sqmm + 1x70 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
70Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply,lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 3x70sqmm + 1x50 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
71Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 3x 150sqmm + 1x120 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
72M&L for Boring for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified by Engr-in-Charge.
73Lopping/prooning of tree branches upto the extend to obtain clearance all around the HT/LT over head lines conductor upto 3 mtr from farthest conductor on pole including removing of cut branches & cleaning of site comple all as specified and directed by Engr in charge. (Note:- (a) The trees branches etc will be left as it is & will not be carried away by the contractor/DEL as the wood belongs to CEO/DEO & they will be responsiblr to lift the wood. (b) Pruning of all tree branches in one tree shall be measured as one Job. (c ) Contractor will employ sufficient labour to complete the Job with in time as directed. (d) Contractor will be responsible for any type mis-happening/accident while pruning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work & clear it before resuming power supply. However, full assistance will be provided by MES staff. (f) The contractor will provide proper tools & safety to his staff for purning of trees.
74M&L for road cuttig existing road for crossing of underground electric cable for laying of any size GI tubing including necessary excavation and earth work including repairing the same as per existing with pre mix bituminious carpet complete all as specefied and as directed by Engr-in-charge. Note: - Width of trench shall be 15 cm and depth shall be upto 30 cm.
75Opening, maintenance and general servicing of servo voltage stabilizer of capacity 50 KVA and 100 KVA incuding removal of sludge from disserstate coils, buck boost transfomers, tightening of all nuts and bolts, cleaning of stabilzer coils, checking and servicing of servo mechanisam, gear, syncronising system, automatic voltage regulator circuits and other allied electrical components complete all as specefied and directed by Engr-in-charge. Note: a) Voltage stabilizer must be repaired by original manufacturer or by authorised service provider of the company. b) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item c) All T & P and transportaion arrangement are deemed to be included in the rates quoted.
76Supply only following parts suitable for three phase servo voltage stabilizer upto 100KVA capacity as per existing make or as recommanded by original stabilizer manufacturer complete all as specified and directed.
77(a ) Volt Meter (Digital/Analog)
78(b) Ampere meter with CT (Digital/analog)
79(c) Micro Processor based control card for each phase
80(d) Servo synchronizing motor single phase AC 230 Volts, 3 Kg torque
81(e) RC Net work for 3 Kg torque servo motor
82(f) Carbon Brush of any capacity
83M&L Preparing surface of servo Voltage Stabilizer complete body and applying painting two coats of suoerior quality synthetic enamel paint using spray gun including sticker work and writing of MES/SM Nos etc complete all as specified and directed by Engineer-in-charge.
84S&F in replacement 45 Watt LED street light new generation energy saving and envoirenment friendly (suitable for fixing on 40 mm dia MS pipe) with pressure die cast aluminium housing & toughened glass with high efficency LEDs as lightibg source , IP-66 degree protection and impact resistance of IK08, individual LED's must have peanut lenses and lens embeded PC cover with top opening seperate driver compartment for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge. Make : Crompton/Havells/Philips or or equivalent to HAVELLS Endura Sunbeam GENX 45
85S&F in replacement 60 Watt LED street light (suitable for fixing on 40 mm dia MS pipe) Clamp with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge. Make : Crompton/Havells/Philips or or equivalent to Wipro-(LR02-102-XXX-57-G2)
86Supply and fixing non transparent looping SMC kiosks pole box 3 phase of size 310×210×120 mm made out of engineering plastic one piece moulding siemens gray colour with hold fast including 4 Nos aluminium strips 60 amp of requird size fixed on unbrakable insulator and one no single pole MCB 1 to 3 amp 'C' curve including taking out of old unserviceable one, complete all as specified and directed by Engr-in-Charge
87S & F rigid non metallic PVC conduit of size 25 mm dia exclusive of boxed (junction/terminal) but inclusive of all tee, bends, elbows, reucers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete all as specified and directed by Engr-in-Charge
88Supply and fixing street light bracket made out of 40 mm light grade GI tubing minimum 1.5 Mtr long with with suitable adapter to suit the opening of street light on one end alongwith integrated fabricated adapter round cup type with 02 Nos studs on outer side to fix the braket on top of existing steel tubular pole two way, with necessary MS clamps with one coat of red oxide and two coats of alluminium paint upon fabricated adapter including nut, bolts, washers complete all as specified and directed by Engr-in-Charge.
89S & F PVC insulated and sheathed 2.5 sq mm two core stranded, aluminium conductor cable from junction box/OH line to street light fitting or for engagement lights complete all specified & directed by Engr-in-Charge.
90Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 4 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specefied and directed by Engr-in-charge.Make :KEI/Polycab/Havells
91Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 6 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specefied and directed by Engr-in-charge.Make :KEI/Polycab/Havells
92Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 10 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specefied and directed by Engr-in-charge.
93Supply and Fixing LT Junction box cubical type of size 75x45x40 cm, 415 volts for outdoor use made out of CRCA Sheet 3.15 mm thick powder coated, machine passed front & rear opening with singal doors for each with privision of rubber beading and locking system including aluminium bus bar 4 srip of size 40mm wide and 6mm thick with provision of hole on bus bar with suitable gaps for each phase (R,Y & B) for fixing of cable mounted on PVC/ epoxy insulators, mounted on angle legs of size 25x25x5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete including all provision of opening for incomming/Outgoing cables with suitable lugs and testing complete all as directed by Engr-in-charge.
94Supply & Fixing Insulation Tape of size 25x3mm(20 Mtrs Long) including taking down the existing unserviceable one, complete all as specified and directed by Engr-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58130537
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint To Lt Distribution System At 222 Asc Bn, Fpd And Other Locations Under Ge(U) Udh Ur.
Basic Detail
Tender No GE/U-110/2026-27
Bidding Type Tender
Location
City Reasi
State Jammu and Kashmir
Key Dates
Publish Date 28 Oct 2026
Submission Date 09 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Not Available
Document List
6bbf66fe-824c-4f1f-a900-1bca3ba29fa1.html
BOQ_891490.xls
CA110.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 9 days
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

6bbf66fe-824c-4f1f-a900-1bca3ba29fa1.html

xls

BOQ_891490.xls

pdf

CA110.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender