Tender For Special Repairs For Replacement Of Electrical Cope Points (Industrial & Domestic) At Pier 1 At Nsry (Kar).
Tender Value
39.20 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
14 days left
EMD
78400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs For Replacement Of Electrical Cope Points (Industrial & Domestic) At Pier 1 At Nsry (Kar).
BOQ
| Sl. No. | Item Description |
| 1 | Supply, install, testing and commissioning of factory-built, CPRI approved make , outdoor type feeder pillar panel, suitable for 415V, 3 Phase, 4 Wire, 50 Hz AC system, fabricated out of SS304 stainless steel suitable for marine/jetty environment, with IP65/IP66 protection, complete with two horizontal compartments, 800 Amps copper busbar systems, and pedestal mounting. copper bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating of suitable Amps for phases and Amps for neutral fixed on porcelain insulators. the panel shall be both front and back openable type adequate space all around accessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings accessories including dismantling of existing socket along with all accessories : |
| 2 | Note for Item No.1.00 above:- Compartment 1 (a) MCCB 630A, 36KA -01Nos Incoming.(b) multi function meter which shows Amps( 800Amps),Voltage ( 500Volts) with and including CTs-01 (c) Internal wiring of panel with stranded copper cable of suitable size. (d) Neon phase indicating lamp(Set of three)-01 Nos. Compartment 2 (a) MCB 63 A , 4 pole- 1Nos with weather proof socket type as per existing.(b) MCB 32A ,4 pole- 1Nos with weather proof socket type as per existing. (c) MCB 16Amps , 2 pole ( 1Phase ) -1 No with weather proof socket type as per existing. (d) Stencilling of panel board including marking of distributions. |
| 3 | Supply, install, testing and commissioning of factory-built, CPRI approved make, outdoor type feeder pillar panel, suitable for 415V, 3 Phase, 4 Wire, 50 Hz AC system, fabricated out of SS304 stainless steel suitable for marine/jetty environment, with IP65/IP66 protection, complete compartments, 800 Amps copper busbar systems, and pedestal mounting. copper bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating of suitable Amps for phases and suitable Amps for neutral fixed on porcelain insulators. the panel shall be both front and back openable type adequate space all around accessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings accessories including dismantling of existing socket along with all accessories : Compartment :(a) MCCB 630A -01Nos Incoming.(b) multi function meter which shows Amps( 800Amps), Voltage ( 500Volts) with and including CTs-02. (c) Internal wiring of panel with stranded copper cable of suitable size. (d) Neon phase indicating lamp(Set of three) - 01 Nos. (e) Stencilling of panel board including marking of distributions. |
| 4 | Supply, install, testing and commissioning of factory-built, CPRI approved make , outdoor type feeder pillar panel SS316 DC feeder pillar panel complete.”(a) Providing and fixing of factory-built outdoor type DC feeder pillar panel, suitable for 220 Volts DC, 2-pole system, fabricated out of SS316 stainless steel suitable for marine/jetty conditions, with IP65/IP66 protection, dust, weather and vermin proof construction, complete with single compartment and pedestal mounting. |
| 5 | Note for Item No 3.00 above: COMPARTMENT CONFIGURATIONSingle Compartment (DC System)1 No. 400 Amps MCCB , 220V DC, 2-Pole connects to copper busbar Heavy-duty DC-rated Suitable for continuous load. BUSBAR SYSTEM Material: Electrolytic Copper BusbarsRating: 600 Amps minimumConfiguration:Positive (+) busbarNegative (–) busbarInsulation: Heat shrink sleeved (Red for +, Black for –)Mounting: SMC / Epoxy supports (marine grade)Proper spacing maintained for DC clearance PANEL CONSTRUCTION (OUTDOOR – MARINE)Material: SS316 (corrosion resistant)Protection: IP65/IP66Door: Single/double door (as required)Neoprene gasket sealingMounting: SS / HDG pedestal CABLING: Existing DC cables to be reused |
| 6 | Supply and laying of 2 runs of 2C x 150 sq.mm Copper conductor, XLPE insulated, armoured cable suitable for 220V DC system, including termination with heavy-duty lugs, double compression glands, dressing, clamping and testing, complete including taking down all as specified and directed by Engr-in-charge. Note: 2 runs of 2C x 150 Sqmm copper conductor XLPE cable shall be measured as one length (units). |
| 7 | Supply & lay or fixing or passing through pipe or in cable ducts, 3 core 240sqmm 1100 volts AC grade, XLPE, armoured, electric power cables (heavy duty) with aluminium conductor including dressing, clamping, gland and termination with copper lugs for 630 Amps , 3 pole cope points complete including taking down as specified and directed by Engr-in-charge. |
| 8 | Supply & lay or fixing or passing through pipe or in cable ducts, 4 core 16sqmm 1100 volts AC grade, XLPE, armoured, electric power cables (heavy duty) with aluminium conductor including dressing, clamping, gland and termination with copper lugs for 63 Amps, 4 pole cope points complete including taking down all as specified and directed by Engr-in-charge. |
| 9 | Supply & lay or fixing or passing through pipe or in cable ducts, 4 core 10sqmm 1100 volts AC grade, XLPE, armoured, electric power cables (heavy duty) with aluminium conductor including dressing, clamping, gland and termination with copper lugs for 32 Amps, 4 pole cope points complete including taking down all as specified and directed by Engr-in-charge. |
| 10 | Supply & lay or fixing or passing through pipe or in cable ducts, 2 core 6sqmm 1100 volts AC grade, XLPE, armoured, electric power cables (heavy duty) with aluminium conductor including dressing, clamping, gland and termination with copper lugs for 16 Amps, 2 pole cope points complete including taking down all as specified and directed by Engr-in-charge. |
| 11 | M&L for providing and carrying out insulation resistance testing of all LT cables, busbars and electrical installations using calibrated Megger (1000V), including phase-to-phase, phase-to-earth and polarity tests for DC systems, recording of values and submission of reports, complete as per IS standards complete including taking down all as specified and directed by Engr-in-charge. |
| 12 | Supply and making of heat shrinkable end termination for 3C x 240 sq.mm Aluminium, XLPE insulated, armoured cable (415V AC system) including glands, lugs, ferruling, insulation and termination complete including taking down all as specified and directed by Engr-in-charge. |
| 13 | Supply and making of heat shrinkable end termination for 2C x 150 sq.mm Copper, XLPE insulated, armoured cable (220V DC system) including double compression glands, tinned copper lugs, hydraulic crimping, polarity identification, insulation and termination to MCCB/busbar complete including taking down all as specified and directed by Engr-in-Charge. |
| 14 | Supply and making of heat shrinkable end termination for 4C x 16 sq.mm Aluminium, XLPE insulated, armoured cable (415V AC system) including glands, lugs, ferruling, insulation and termination complete including taking down all as specified and directed by Engr-in-Charge.. |
| 15 | Supply and making of heat shrinkable end termination for 4C x 10 sq.mm Aluminium, XLPE insulated, armoured cable (415V AC system) including glands, lugs, insulation and termination complete including taking down all as specified and directed by Engr-in-Charge. |
| 16 | Supply and making of heat shrinkable end termination for 2C x 6 sq.mm Aluminium/Copper, XLPE insulated, armoured cable (230V AC system) including glands, lugs, insulation and termination complete including taking down all as specified and directed by Engr-in-Charge.. |
| 17 | M&L for taking out existing earth plate electrode including excavation, removal of earth lead, charcoal, salt and all connected fittings complete, making good disturbed surfaces, and depositing the serviceable earth plate and accessories in schedule of credit complete all as specified and as directed by Engr-in-charge. |
| 18 | M&L for copper strip 32x6mm with saddles and fixing screws etc for connecting with Electrical panel to earthing test point through tunnels complete all as specified and directed by Engr-in-charge. |
| 19 | M&L for Earthing complete with copper plate 60×60cm ×3.15mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including copper strip earth strip 32x6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 20 | M&L of PCC 1:2:4 type B2 ( 40mm graded crushed stone aggregate) PCC foundation for pillar boxes including grouting with nuts and bolts and finishing complete all as specified and directed by Engr in charge. |
| 21 | S&F MCCB 630 Amps ,415 volts, 4 pole , 50KA with knob suitable to fix in existing Lt panel at substation with knob in repairs all as specified and directed by Engr in charge . |
| 22 | S&F Multi function meters to fix inside the existing Lt panel which indicates, Amps, volts, PF etc in repairs all as specified and directed by Engr in charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender