Tender For Repair/Replacement And Maintenance Of Geyser, Fans, Solar Water Heater And Connected Items At Vsn Chiloda
Tender Value
48 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
14 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gandhinagar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement And Maintenance Of Geyser, Fans, Solar Water Heater And Connected Items At Vsn Chiloda
BOQ
| Sl. No. | Item Description |
| 1 | S&F in replacement PUF insulated, seven tank processed and pure polyster powder coated, FPC based non pressurized and non heat exchanger solar water heater storage tank of capacity 100 LPD, Max working pressure 0.5 Kg/cm2, anti corrosive and heat resistant inner coating, 50 mm thick machine injected PUF insulation of 38 kg/m3 density, 0.45 mm thick precoated GI sheet outer cladding complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. |
| 2 | S&F in replacement PUF insulated, sevemn tank processed and pure polyster powder coated, FPC based non pressurized and non heat exchanger solar water heater storage tank of capacity 1000 LPD Max working pressure 0.5 Kg/cm2, anti corrosive and heat resistant inner coating, 50 mm thick machine injected PUF insulation of 38 kg/m3 density, 0.45 mm thick precoated GI sheet outer cladding complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. |
| 3 | S&F in replacement Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290. Gde-E-165 complete all as specified and directed by Engineer-in-charge. |
| 4 | S&F in replacement flat plate collector of size 1033mm x2033mm x95mm, as per BIS 12933 part I, copper fin aboserber plates, 9 nos of 0.56 mm rthick copper tube riser having 12.7 mm outer diameter, rockwool insulation, brass flanges complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. |
| 5 | S&F in replacement solar water heater heating element for solar 3 Kw/3000 Watt, 1.5 inch flange Hex head nut type thread with tharmostat pocket solar heating coil as per existing sample, 230 Volt, 50 Hz, AC complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. |
| 6 | M&L for repair/servicing and descaling of flat plate collector/ tube collector solar water heater of capacity 1000 LPD by opening of panel, servicing, cleaning, drilling, removing the scaling, breezing, closing the panel, changing flange rubber, nut and bolts complete all as specified and directed by Engineer-in-charge .Note:- Servicing / De-scaling will be carried by OEM as approved by GE. |
| 7 | M&L for repair/servicing and descaling of flat plate collector/ tube collector solar water heater of capacity 100 LPD by opening of panel, servicing, cleaning, drilling, removing the scaling, breezing, closing the panel, changing flange rubber, nut and bolts complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. |
| 8 | S&F in replacement PUF insulated makeup tank of capacity 5 ltr (as per existing sample) to be fixed on any capacity solar water heater complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. |
| 9 | S&F in replacement Evacuated tubes double wall Glass-Glass type evacuated, 3.3 Borosilicte glass of thickness 1.6mm, selective coating with latest double walled magnetron sputtering technology, tube diameter 58 mm and length 1800 mm complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. |
| 10 | Supply and fix in repair stainless steel Geyser Assembly 6 hole/9 hole Rectangular/ Trinagular/ round of water heater for 25/50 Ltrs capacity AC 230V as per sample complete all as specified and directed by Eng-In-Charge. |
| 11 | Supply and fix in repair Outer Body with top and bottom cover of water heater for 25 Ltrs capacity AC 230V as per existing smaple complete all as specified and directed by Eng-In-Charge. |
| 12 | Supply and fix in repair Inner glass line tank for geyser cap 25 ltr of as per existing sample complete all as specified and directed by Eng-In-Charge. |
| 13 | Supply and fix in repair Water heater heating element for 25 Ltrs capacity 1.5/2 KW, Rectangular/triangle/round/Spiral as per sample complete all as specified and directed by Eng-In-Charge. Please Enable Macros to View BoQ information |
| 14 | Supply and fix in repair Water heater heating element for 25 Ltrs capacity 1.5/2 KW, Rectangular/triangle/round/Spiral as per sample complete all as specified and directed by Eng-In-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender