Tender For Petty Repair Wks To Offrs Fam Ward, Officers Ward, Jco Ward, Offrs Waiting Area, Opd Area & Joint Filling In Plain Cement Concrete Tiling In Hospital Complex And Repair To Internal Electrical Wks Under Ge(S) Pune

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
48.98 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
15 days left
EMD
97960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Petty Repair Wks To Offrs Fam Ward, Officers Ward, Jco Ward, Offrs Waiting Area, Opd Area & Joint Filling In Plain Cement Concrete Tiling In Hospital Complex And Repair To Internal Electrical Wks Under Ge(S) Pune

BOQ

Name of Work:- PETTY REPAIR WKS TO OFFRS FAM WARD, OFFICERS WARD, JCO WARD, OFFRS WAITING AREA, OPD AREA & JOINT FILLING IN PCC TILING IN HOSPITAL COMPLEX AND REPAIR TO INTERNAL ELECTRICAL WKS UNDER GE(S) PUNE
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
2M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base / flooring complete all as specified and directed.
3M&L for vitrified tiles dark shade/fully body charged (600X1200X8-10 mm thick) in floors area of each tiles exceeding 0.42 sqm but not exceeding 1.0 sqm, over & including 20 mm thick screed bed in CM 1:6 complete all as spd and as directed.
4M&L for vitrified tiles dark shade/fully body charged (600X1200X8-10 mm thk) on vertical surface area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10 mm thick plaster in CM 1:6 complete all as spd and as directed.
5M&L for 400x400x7-8 mm thk anti-skid ceramic colored tiles 7 to 8mm thick (square / rectangular), as in floor etc. set and jointed in neat cement slurry & pointed in white or coloured cement to match laid over and including 20 mm thick screed bed in CM 1:6, including dismantling floor, hearth, removing rubbish off the MOD land complete all as speicified and directed. complete all as speicified and directed.
6M&L for coloured glazed ceramic designed tiles on vertical surface 600x 300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & incl. 10 mm thick backing coat in CM 1:6 to maintaine true plumb incl dismantling floor, hearth or wall tiling including taking down backing coat, removing rubbish off the MOD land complete all as speicified and directed.
7M&L for 16 -18 mm thick Granite slab (of any type/colour) work (table rubbed and polished) in steps, pillars;window cills/jamb, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. as counters of any radius etc laid over & including 20 mm thick screed bed in CM ( 1:6) including demolition of existing stone slab of any description all as specified and directed.
8M&L for 16 -18 mm thick Granite slab (of any type/colour) work (table rubbed and polished) on walls, skirtings and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc laid over 10 mm thick plastering in CM ( 1:6) including demolition of existing stone slab of any description all as specified and directed.
9Rounding to edges of stone slabs and polishing in edges, such as in steps,shelf cooking platform, and other similar situations complete all as specifed and directed.
10M&L for 16 to 18mm thick mirror polished kota stone over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over & including 20mm thick screed bed in CM 1:6 all as spd and as directed
11Taking down chowkats or frames with shutters (without taking out shuuters from the frame) exc 1.5 sqm and ne xc 4.00 sqm each including hold fasts and removing the same from site all complete as directed.
12S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
13Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
14S&F 150mm long aluminium, anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed by Engineer-in-Charge.
15S&F powder coated 150mm size aluminium handles, fabricated type, anodised and fixed complete all as spd and as directed.
16S&F of powder coated 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed etc complete all as specified and directed by Engineer-in-Charge.
17S&F 100mm Butt hinges, extruded alu minium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 etc complete all as specified and directed by Engineer-in-Charge.
18Dismantling of wrought or MS work of any description etc as directed.
19S&F for rolled mild steel conforming to grade E-250 (Fe-410W, quality A) as in post, main and cross beams, hip and jack rafters, purlins, where connected to common rafters and running rails and guides for sliding doors, fixed with angle clips or other connecting plates all as specified and directed.
20Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
21S&F in repair of 3 mm thick polycarbonate sheet with rubber EPDM of section(Domeset)and fixing the sheet between male and female aluminimum section with self tapping screws and rubber washer to make it leak proof incl dismantling of old poly carbonate sheet of any thickness in any position of roof covering or in other similar work complete all as specified and directed complete all as specified and directed.
22S&F Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame including 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specifications and directed by Engineer In- Charge.
23Vinyl Patch Installation: Installation of matching shade of Vinyl flooring of identical specifications,including Vinyl Patch Removal : Removal of Vinyl flooring by cuting in flooring Make: Tarkett/Gerfloor/Jeofloor.
24Vinyl Patch Welding: Welding using vinyl welding rods complete all as specified and directed.Make: Tarkett/Gerfloor/Jeofloor.
25Providing and carrying out tile gap sealing using non-shrink cementitious sealant MYK Laticrete after cleaning and preparing the joints, filling all tile gaps completely to achieve a durable and watertight finish Including Cutting out cracks in existing roofs or terracing, cleaning out, wetting. The rate shall include all materials, labour, tools, consumables, and incidental works complete as per the manufacturer's specifications
26Supply only PU (Polyurathane) material suitable for PU injection water proofing for walls,slabs, beams etc single or double component as per site requirement.Make: Dr Fixit, Asian Paints, Sika, Fosroc.Note: Engr-in-Charge/JE shall ensure quantum of material supplied by contractor strictly and purchase voucher/invoice of the material duly verified and defaced to be kept on record.
27Chemical treatment to arresting leakag/seepage in any building structure using PU injection grouting technology (Except PU material). The work consists of preparation of site hindrance free by moving/shifting of existing movable furniture etc. Supply and fixing of NRV mettalick packers/Nozzles (generally @300mm C/C by drilling 100mm bore) mixing and penetration of water proofing chemical using high pressure (not less than 0.20/mm2) curing, removal of nozzles and making good to drilled holes and including all others necessary activities to get best and guranteed water proofing works.Note: (1) All procedures must be strictly as per manufactures instruction and to fullly satisfaction of Engineer-in-Charge.(2) The work will be executed by authorised applicator of manufactures. The Documentary proof to be submitted to Engineer-in-Charge and kept in sub division record.
28Supplying & apply of two coat of sikka lastic 562 PU with and over a coat of flow -13300(2A+2B) primer including cleaning and removing of surface before application of primer & PU coat all as manufacturer instruction complete all as specified and directed by engr-in -charge.
29S&F in repair PVC low level flushing cistern 10 ltrs capacity approved make incl all internal fitting, pair of bracket, including inlet/outlet PVC pipe connections etc complete as directed by Engr-in-Charge.
30S & F in repairs Plastic water closet seat cover of any colour, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
31S & F in repair PVC connection 45 cm long 15 mm bore with 2 Nos brass check nuts fixed complete all as specified and directed.
32S & F in repair PVC connection 60 cm long 15 mm bore with 2 Nos brass check nuts fixed complete all as specified and directed.
33S & F in repair 600mmx450mm mirror of selected quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed.
34S & F in repairs PVC flexible waste pipe 32 mm bore complete all as specified and directed.
35S & F in repair 15 mm bore brass chromium plated Bib cock with wall flange and nozzle etc complete as specified and directed.
36S&F in repair 15 mm bore brass chromium plated pillar cock table mounted regular basin tap etc complete as specified and directed.
37S & F in repair Angle cock with wall flange 15mm bore brass chromium plated complete all as specified and directed by Engineer-in-Charge.
38S&F in repair brass chromium plated sink mixer with swinging casted spout (wall mounted model) with connecting legs and wall flanges for 15mm bore of pipe complete all as specified and directed.
39S&F in rapair 15mm bore brass chromium plated Basin Mixer for hot and cold water without popup waste with 450mm long Braided Hoses complete all as specified and directed. (Make : Jaquar Product code ARI-CHR-39001B or equivalent model in Kohler as approved by GE.
40S&F in repair Brass CP wall mixer for 15mm bore of pipe conforming to CAT No. CQT-23273UPR of \\"Jaquar\\" or of make Kohlar,Hindware complete all as spd and as directed.
41S & F in repairs,15mm bore brass chromium plated Two way bib cock with wall flange toilet fittings conforming to CAT No. FUS-29041 of jagur or of make Kohlar ,Hindware complete all as spd and as directed.
42S&F in repair brass chromium plated shower rose of size 125mm with or without swivel joints, including fixing to a steel pipe or union complete all as specified and directed.
43S & F in repairs 20mm dia D type tabularTowel rail 600 mm long brass chromium plated etc complete, all as specified and directed .
44S&F in repairs Meridien Towel Ring Square Chrome Plating etc complete, all as specified and direcrted.
45Glass shelf assembly Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
46S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
47Providing, fixing, and commissioning of Floor-Mounted Single-Piece European Water Closet (EWC) with flushing cistern of premium Vitreous China ceramic material with an anti-microbial/anti-germ glaze finish, dimensions 360x640x685 mm, having an S/P-Trap configuration . The assembly must feature an integrated flushing cistern with heavy-duty internal dual-flush mechanism (3/6 Litres Per Flush), Box Rim water delivery system, and include a heavy Polypropylene (PP) soft-close seat cover, stainless steel/corrosion-resistant hinges, complete floor fixing accessory kit with anchoring brackets/side caps, and a specialized wax seal gasket to guarantee zero-leak and odor-proof connections. All work shall be executed as per standard engineering specifications, tested for hydraulic flushing, and fully directed by the Engineer-in-Charge / Garrison Engineer (GE). (Preferred Make: Jaquar Solo Range Cat No. SLS-WHT-6851S110PP or Kohler/hindware)
48S&F in repairs vitreous china counter top wash hand basin (excluding taps, waste, pipe chain and plug) but including fixing on granite plateform complete all as speicified and directed. (Note : Granite support and top to be measured seperately)
49S&F in repairs CP Bottle trap 32mm Size with 300mm & 190mm Long Wall Connection Pipes & Wall Flange CAT No-ALD-769L300x190 of \\"Jaquar\\" or of make Kohler,Hindware complete all as specified.
50S&F in repair Toilet paper holder with flat recessed type brass CP or stainless steel Complete all as specified and directed
51S&F in repair Soap dish brass chromium plated. Cat ID AHS-1531 Jaquar or of make Kohler,Hindware complete all as spd and as directed.
52S&F in repair SS curtain rod 25mm bore all as specified and directed.
53S&F in Repair SS brackets suitable for 25mm bore curtain rod (minimum projection from wall 75mm) fixed in wall including drilling, rawl plug, screws etc complete all as specified and directed by Engineer-in-Charge.
54S&F in repair 150mm long aluminium, anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed by Engineer-in-Charge. .
55S&F in repair powder coated 150mm size aluminium handles, fabricated type, anodised and fixed complete all as spd and as directed.
56S&F in repair of powder coated 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed etc complete all as specified and directed by Engineer-in-Charge.
57S&F in repair 100mm Butt hinges, extruded alu minium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 etc complete all as specified and directed by Engineer-in-Charge.
58S&F in repair casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc complete all as specified and directed by Engineer-in-Charge.
59M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4), the surface even and Smooth without extra cement Including chicken wire mesh including taking down cement plaster on stoneor brick wall walls including raking out joints, hacking for key, scrubbing down with water all as specified
60M&L for rendering 10 mm thick in cement mortar 1: 6 on fair faces of Brick/AAC block/PCC block work or concrete surfaces finished even & smooth without using extra cement Including chicken wire mesh including taking down cement plaster on brick or stone surface of wall built in cement sand mortar including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
61M & L for preparation of New surface of wall apply two coats of Plastic emulsion paint over primer over plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth on wall complete all as specified & directed by Engineer-in-Charge.
62M & L Preparation of New surfaces and applying two coat of weather proof exterior acrylic emulsion paint (1st Quality) on walls, cornices, borders, facia of chajjas & projected columns complete all as specified and directed. Note :- Exterior acrylic emulsion paint shall be anti-fungal, dust resistant, water repellant, crack-bridging, weather proof type 1st Quality.
63S&F in repair following accessories of Auto sliding doors of OT in New Command hospital for efficient and effective performance of the doors complete all as s specified and directed by Engr-in charge and as per manufacturer (Make - WIESPL, PUNE)
64SDA04 DC Controller:
65DC Motor:
66Motor Pulley:
67Battery: 24V
68Adaptor for DCB controller:
69Teeth belt:
70Photo cell:
71Foot sensor: IR based sensor for Sliding of Door
72Taking down carefully aluminium / copper point wiring with surface/ concealed PVC conduit or wooden batten ( light, fan, socket, bell or power ) including sunk in cast iron / pressed steel terminal boxes except fitting such as switches, ceiling roses, lamp holders, sockets, regulators, call bells, light fittings of any sketch etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engr-in-Charge.
73M & L in replacement of for Point wiring with PVC insulated FRLSH 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade two single core, PVC insulated and unsheathed stranded FRLSH cable 1100 volts grade, in PVC rigid conduits heavy duty, medium grade, ISI marked (min 20 mm dia, size of conduit shall be according to max numbers of wires permissible to be drawn as per IE rule) with valid CML No, totally concealed in stone or brick wall/floor and open conduit on surface (inside room) along roof /ceiling and in surface conduit on RCC/ wodden partition wall / in corridor above false ceiling including all accessories as required complete including GI Metal Flush boxes (min thick ness 0.8 mm) with modular frame/cover plate of suitable size for mounting modular switches/sockets etc and PVC insulated muti stranded FRLSH copper conductor 1.5 Sqmm single core cable (Green colour) as earth conductor and connecting to common earth dolly complete all as specified and directed by Engineer in Charge for the following
74One light point/fan point /Exhaust fan point controlled by one switch
75One socket outlet 5 Amps controlled by one switch on the same board.
76One socket outlet 5 Amps controlled by one switch on independent board.
77One bell / buzzer controlled by one bell push.
78All as per item No.65 above but with 2.5 Sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 2.5 Sq mm PVC insulated multistranded copper conductor cable as continuous earth wire complete all as specified and directed by Engr-in-Charge.
79M & L in replacement of for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with pvc surface boxes with earth dolly duly as per site requirment , covered with modular white cover plate with frame /PVC frame suitable for modular switches/ flush type switch socket of including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
80One light point/fan point /Exhaust Fan point controlled by one switch
81One socket outlet 5 Amps controlled by one switch on the same board.
82One socket outlet 5 Amps controlled by one switch on independent board.
83One bell / buzzer controlled by one bell push.
84All as per item No.-67 above but with 2.5 Sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 2.5 Sq mm PVC insulated multi stranded copper conductor cable as continuous earth wire complete all as specified and directed by Engr-in-Charge.
85M&L in repair for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed (Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping/conduit shall be measured as one RM)
86M&L in repair for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 6 sqmm continuous earth wire complete all as specified and directed (Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping/conduit shall be measured as one RM)
87M&L in repair for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 1.5 Sqmm , 1100 Volts grade in and including PVC Conduit/casing n caping medium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM)
88M&L in repair for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM)
89M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area,multi core core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH conforming to IS with and including continuous earth wire of 2 run size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI MARKED PVC conduit including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. including taking down of old sub main wiring all as specified & directed. Note:-One meter of conduit along with 4 run of 6 sq mm wire and 2 run of 4 sq mm earth shall be measured as one unit length
90M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size with 10 Sqmm nominal cross sectional area,multi core core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH with and including continuous earth wire of 2 run size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI MARKED PVC conduit including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. including taking down of old sub main wiring all as specified & directed. Note:-One meter of conduit along with 4 run of 10 sq mm wire and 2 run of 6 sq mm earth shall be measured as one unit length
91S & F in replacement and replacement of Ding Dong Bell AC, 240 Volts single pole complete all as specified and as directed.
92S&F in replacement IP-43, protection metal double door Vertical TPN -DB 200 A rated busbar, pan assembly etc. with interconnection links, blanking plates, cable ties, identification labels TPN 4 way, 12 modules with provision to mount 125 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed/fixed on wall/board as required including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make-indo asian/legrand/havells
93All as per item No -76 but 8 way -24 module
94S&F in replacement,IP-43 ,MCB DB TPN 4 way ,double door, with busbar 415 V, and concealed/fixed on wall/board as required including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing
95Supply and fix in repair and replacement of sheet metal enclosures for SPN DB's 240 volts, factory made double door flush type, IP-42 protection and all as per IS-8623, made from sheet metal 8 way 100 amps rated bus bar to be fixed with wall all accessories complete including taking down unserviceable fitting complete all as specified and as directed by Engr-in-Charge.
96All as per item No-79 above but 12 way DB
97All as per item No-79 above but 4 way DB
98S & F in replacement of Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket with and including one single pole MCB 20 Amps 240 volts complete including taking down unserviceable fitting complete all as specified and as directed by Engr-in-Charge.
99S&F in replacement of MCB Single pole and neutral rated capacity 40 to 63A, 240 V breaking capacity 9KA C series
100S&F in replacement of MCB Single pole rated capacity 5 to 32 A, 240 V breaking capacity 9KA C series complete all as specified and as directed
101S&F in replacement MCB TPN 63 Amps ,10KA,415 V,'C' series complete all as specified and as directed
102S&F in replacement of 1100 Volts grade heavy duty service line cable PVC insulated aluminium conductor, twin core cable, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or cicrular of aluminium condoctors size 10 Sqmm stranded conductor all as directed incl taking down old unsv complete.
103All as per item No- 86 above but size 6 sqmm
104All as per item No- 86 above but size 4 sqmm
105M & L in replacement of earth continuity conductor or main earth lead fixed to wall or buried in ground or drawn in GI pipe with 4 sqmm GI Wirecomplete all as specified and directed.
106M & L in replacement of for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
107S & F in replacement of Modular switch1 way 6A,240 Volts 1 module compatible with existing modular frame complete all as specified and directed
108S & F in replacement of Modular switch 1 way 16A, 240 Volts 1 module compatible with existing modular frame complete all as specified and directed
109S & F in replacement of of Modular Bell push 6A 1 module compatible with existing modular frame complete all as specified and directed
110S & F in replacement of of Modular Socket, 6A - 5 pin combined 2 module compatible with existing modular frame complete all as specified and directed
111S & F in replacement of of Modular Socket 6A/16A - 2/3 pin combined 2 module compatible with existing modular frame complete all as specified
112S & F in replacement of of Modular Fan step regulator 100 W, 240 Volts 1 module compatible with existing modular frame complete all as specified
113M & L in replacement of in replacement of ceiling rose surface bakelight two to three terminal complete all as specified and directed
114M & L in replacement of Lamp Holder, insulated body, with back plate for batten fitting complete all as specified and directed .
115S & F repair of switch piano flush type pole one way 6 Amps, 240 V complete. Including old unsv taking down
116S & F in replacement of Socket outlet 5 pin 6 Amps, 240 V flush type complete. Including old unsv taking down
117S & F in replacement of Switch Socket combination with box 5 pin 6 /16Amps, 240 V flush type complete. Including old unsv taking down
118S & F in replacement and replacement of Bell push, flush type, 5 Amps complete.Including old unsv taking down
119S & F in replacement switch socket combination outlet flush type multi purpose with/without gang box 2 in 1, 3 pin 6/16 Amp, 230 Volts complete as directed.Including old unsv taking down
120Supply and fix in replacement of five step type fan regulator 100W, socket type all as specified and directed
121Supply and fix in replacement of slim fan regulator 100W, socket type complete all as specified and directed
122Supply & fix in repair recess mounting LED down light fitting of Powder coated die cast /Extruded aluminium Body of 9 Watt capacity and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver driver with SMPS and efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours CCT 3000°K / 4000°K / 5700°K /6500°K . System lumen efficacy ≥120 lm/Watt output compaitable with Existing Cut Out diameter and making good the pop/gypsum ceiling with good finish as existing with suitable fixing arrangement, connection complete all as specified and directed.
123All as per Item No 106 above but capacity 12 watt complete
124All as per Item No 106 above but capacity 15 watt complete
125All as per Item No 106 above but capacity 18 watt complete
126Supply & fix in repairs recess mounting LED spot/Cob light fitting die cast aluminium housing 18Watt capacity and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver driver with SMPS and efficiency >85%, Operating voltage AC 140-280 Volt, frequency 50 HZ, Operating temp range -10OC to 50OC, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.90, IP20, CRI >80, life time (LED,Driver & electrical circuitry), of minimum 30000 Burning Hours CCT 3000°K / 4000°K / 5700°K /6500°K . System lumen efficacy above 85 lm/Watt output and compaitable with existing cutout diameter and making good the POP / gypsum ceiling with good finish as existing with suitable fixing arrangement connection complete all as specified and directed by Engr-in-Charge.
127S & F in repar LED pannel Recess mounted -2'x2' of powder coated die cast /Extruded aluminium Body of 36 watt capacity and construction as per IS : 10322 with driver with SMPS as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50 hz, Operating temp range -10°C to 45°C, internal surge protection of 4 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), System lumen efficacy ≥120 lm/Watt output complete including cutting hole of required size in POP/false ceiling or surface making good disturbed / surface including taking down any type ceiling fitting complete all as specified and directed by Engr-in-Charge.
128Supply & fix in replacement of LED fixture surface mounted 2 ' X 2' ceiling light of Powder coated die cast /Extruded aluminium body of 36 watt capacity and construction as per IS : 10322 with driver with SMPS as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50 hz, Operating temp range -10°C to 45°C, internal surge protection of 4 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), System lumen efficacy ≥120 lm/Watt output complete all as specified and directed by Engr-in-Charge.
129Supply and fixing in replacement of Panel light 2x2 ft., of Powder coated die cast /Extruded aluminium Body of 36 watt capacity recesed type with Opal difuser and luminarie provided with PIR Sesor detection range 2.5 - 4 mtr hightt, 12 m walk scross motion PPGI Sheet Steel Housing suitable for roof ceiling /surface mounted including connecting up with driver three core flexible copper conductor cases of suitable size and construction as per IS : 10322 with driver with SMPS as per the requirement with Driver efficiency >85%, Operating voltage AC 140-280 Volt, frequency 50 hz, Operating temp range -10°C to 50°C, internal surge protection of >3.0 KV to 40.KV with Short & Open circuit protection ,THD < 15% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , CCT 3000°K / 4000°K /6500°K (As per ANSI Bin), System lumen efficacy 110 to120 lm/Watt output complete including cutting hole of required size in POP/false ceiling and making good disturbed surface complete all as specified and directed by Engr-in-Charge.
130S & F in repair LED pannel Recess/ Surface mounted -1' X 4' of CRCA Powder coated die cast /Extruded aluminium Body with SS Frame of 40 watt capacity natural white/worm white and construction as per IS : 10322 with driver with SMPS as per the requirement with Driver efficiency >85%, Operating voltage AC 140-280 Volt, frequency 50 hz, Operating temp range -10°C to 45°C, internal surge protection of 4 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , CCT 4000°K /5700°K 5700°K/6500°K (As per ANSI Bin), System lumen efficacy ≥120 lm/Watt output complete and including cutting hole of required size in POP/false ceiling or surface making good disturbed / surfacemounted including taking down any type ceiling fitting complete all as specified and directed by Engr-in-Charge.
131Supply and fixing in replacementceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor complete all as specified and directed.(Note: Old Ceilng fan should be deposited in MES store yard)
132Supply & fix in replacement LED batten extruded aluminium housing opal diffuser in built occupancy radar sensor of powder coated extruded aluminium Body of 20 watt capacity and construction as per IS : 10322 with driver with SMPS as per the requirement with Driver efficiency >85%, Operating voltage AC 140-300 Volt, frequency 50 hz, Operating temp range -10°C to 45°C, internal surge protection of > 3 KV with Short & Open circuit protection ,THD < 15% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , CCT 6500°K (As per ANSI Bin), System lumen efficacy ≥100 lm/Watt output complete and all as specified and directed by Engr-in-Charge.
133Supply & fix in replacement LED retrofit aluminium Tube Rod 20 watts single/double side wire connection complete and all as specified and directed by Engr-in-Charge.
134S& F In replacement of PVC modular gang box of following size Plain /Vertical/ Horizontal inclor including PVC modular frame fixing modular /flush switch socket regulator complete all as specified and directed.
135PVC modular gang box 3M
136PVC modular gang box 6M
137PVC modular gang box 8M
138PVC modular gang box 12 M
139S&F in replacement for white cover plate with frame 3 module complete all as specified and as directed.
140S&F in replacement for white cover plate with frame 6 module complete all as specified and as directed.
141S&F in replacement for white cover plate with frame 8module complete all as specified and as directed.
142S&F in replacement for white cover plate with frame 12 module complete all as specified and as directed.
143S&F in repair PVC unbreakable surface boxes for mounting flush type switches of size 4x4 all as specified and directed.
144S&F in repair PVC unbreakable surface boxes for mounting flush type switchesof size 6x6 all as specified and directed.
145S&F in repair PVC unbreakable surface boxes for mounting flush type switchesof size 4x7 all as specified and directed.
146S&F in repair PVC unbreakable surface boxes for mounting flush type switchesof size 6x8 all as specified and directed.
147S&F in repair PVC unbreakable surface boxes for mounting flush type switchesof size 8x10 all as specified and directed.
148M&L for secruing loose wiring and repair to point wiring with necessary rigid non metalic PVC casing caping double lock type/ PVC conduit ISI marked of size not less than 25 mm X 12 mm inclusive all accessories complete as specified and directed.
149S&F flexible heavy duty conduit pipe ivory grey in colour of dia not less than 25 mm complete all as specified and directed. Make: As per sample approved by Engr-in-charge
150S&F in repair of unserviceable Multicore Round PVC insulated copper Cables of size 1.5 sqmm single core FRLSH insulated multistranded copper conductor for working voltage 1100 volts sqmm complete all as specified and directed.
151S&F in repair of unserviceable Multicore Round PVC insulated copper Cables of size 2.5. sqmm single core FRLSH insulated multistranded copper conductor for working voltage 1100 volts sqmm complete all as specified and directed.
152S& F in replacement double MS hook with pin anchor fastner including fixing on hard concrete surface complete all as specified snd directed
153S& F in replacement Pin anchor fastner of size(12 X 75 ) including fixing on hard concrete surface complete all as specified snd directed
154S&F in repair of Plastic ventilation fan of 200 mm sweep inclduing replacing the plywood as per the site requirement complete all as per specified
155S&F in repair of Plastic ventilation fan of 250 mm sweep inclduing replacing the plywood as per the site requirement. complete all as per specified
156S&F in repair of Plastic ventilation fan of 300 mm sweep inclduing replacing the plywood as per the site requirementcomplete all as per specified
157S&F in repair of Plastic fan of 150 mm sweep inclduing replacing the plywood as per the site requirement complete all as per specified
158Supply and fix in replacement exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame complete all as specified and directed.
159Supply and fixing in replacement electric storage water heater 25 Ltr , 2 KW 5 star rating comprising of glasslid inner tank, Magnesum anode, copper heating element, multi function safety valve ,Adjustable thermostate degree of protectionIPX 4 including connection pipe complete all as specified and directed. (Note: Old Storage water heater should be deposited in MES store yard)
160S&F in replacement metal clad plug top 3 pin,20 Amps, 230 volts, ISI marked heavy duty for geyser connection cord all as specified and directed.
161Taking down ceiling fan/exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, with new Ceiling hook with rubber , connecting up and testing complete all as directed.Note : 1.Cost of spares such as capacitors, bearings etc will be measured and paid for separately under respective Item of sch A as supply only.
162Supply only capacitor of 2.5 mfd for ceiling fan/exhaust fan all as specified and directed.
163Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan.
164S&F in replacment fan blades sutable for existing ceiling fan fan of any sweep as per the sample given by the site-in-charge
165M& L for rewinding of fan 1200/1400 mm sweep of any type and size/sweep as described below, removing the burnt winding of fan motor rewinding with super enarneled copper winding wire of suitable gauge or of matching size to the exisiting wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and reflxing to original position all as directed by Engineer-in-charge for following :-
166All as per item No-145 above but exhaust fan/wall monted fan 200/ 350/400 mm sweep
167M&L for painting the ceiling fan of 1200/1400 mm sweep and exhaust 300 /350 mm sweepwith two coats of synthentic enamel paint by rubbing/removing the old paint carefully without any damage to the fan or fan blades all as specified.
168S&F in replacement of burnt out and unserviceable fan motor assembly complete including double bearing, copper windng with metal plate top & bottom side suitable for 1200mm sweep in any existing make complete all as specified and as directed by Engr-in-Charge.
169Supply and fix repair and replacement of hanging rod made out of GI Pipe medium grade 15 mm dia with U clamp, fastner ncluding drilling cutting threading etc complete all as specified and directed for ceiling fan 1200/1400 sweep of fwg size
1702 ft long
1713 ft long
1724 ft long
173S&F in replacement heating element of capacity 2 KW compaitable with existing 25 ltrs capacity geysers complete all as per specified.
174S&F in replacement thermostat 0-85⁰C compaitable with existing 25 ltrs capacity geysers complete all as per specified.
175Supply and fix in replacement of heavy duty stainless steel 304 grade Geyser pipe with PTMT nuts suitable for Hot or Cold water heavy duty of length 18 inch long complete all as specified and as directed.
176S&F in replacement of MCCB with rating of 125 Amps, 415Volts 4 pole with ICU 25 KA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS/IEC - 60947-2.MCCB should be with suitable spreaders and phase barriers for each terminals,nut bolt all as specified and directed.
177Dismantling and removing rusted louvers at any hight , size 300 -350 mm sweep exhaust fan and supply and fix MS louvers at any hight duly painted gray coloured size 300 to 350 mm sweep heavy duty exhaust fan alongwith four number mounting bracket with bolts, nuts washers etc complete all as directed.
178Supply and fix in replacement of heavy duty stainless steel 304 grade Geyser pipe with PTMT nuts suitable for Hot or Cold water heavy duty of length 36 inch inch long complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58130522
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.98 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Petty Repair Wks To Offrs Fam Ward, Officers Ward, Jco Ward, Offrs Waiting Area, Opd Area & Joint Filling In Plain Cement Concrete Tiling In Hospital Complex And Repair To Internal Electrical Wks Under Ge(S) Pune
Basic Detail
Tender No 8899 GE SOUTH PUNE
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 19 Oct 2026
Submission Date 09 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 48.98 Lakhs
Tender Fee 500
EMD 97960
Exemption Available
Document List
8899TenderDocs.pdf
BOQ_891361.xls
f844657d-4d40-430e-895a-e2d08b41b5c1.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.