Tender For Preventive Maintenance Of Cooling Appliances At Various Locations And Preventive/Corrective Maintenance For Repair/Replacement Of Led Light Fittings At 172 Inf Bn And installation Baaz Under Ge C Bell Bay
Tender Value
33 Lakhs
Estimated cost
Bid Submission
11 Nov 2026
11 days left
EMD
66000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Preventive Maintenance Of Cooling Appliances At Various Locations And Preventive/Corrective Maintenance For Repair/Replacement Of Led Light Fittings At 172 Inf Bn And installation Baaz Under Ge C Bell Bay
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Servicing of Split type air conditioner in citu (Split type air conditioner comprises wiith out door and indoor unit complete) of capacity 1.5 TR of any make and any type cleaning of outdoor condenser coil with water pressure pump and indoor unit coil cleaning by proper bresh and checking of electrical circuit and replacement of defective electric blower fan motor,over load protector,relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning complete all as specified and directed. |
| 2 | Description all as per item No 1.00 here in before but capacity 2 TR |
| 3 | Description all as per item No 1.00 here in before but capacity 5 TR |
| 4 | M&L for servicing of Deep freezer of size upto 320 Ltr at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed. |
| 5 | M&L for servicing of Refrigerator any size at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed. |
| 6 | M & L for servicing of Water cooler of any capacity at existing location by cleaning of condenser, cooling coil, and other components with cooling coil Rinse solution & clean water, greasing of fan, motor including cleaning of storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of complete all as specified and directed. |
| 7 | S&F PVC connections 15 mm size with PTMT nuts of length 300 mm has inlet for hot/ cold water with brass nuts at both ends complete all as specified and directed. |
| 8 | S & F White cover plate with frame, 4 module complete all as specified and directed. |
| 9 | S & F White cover plate with frame, 8 module complete all as specified and directed. |
| 10 | S & F Modular Metal flush box, 4 module complete all as specified and directed. |
| 11 | S & F Modular Metal flush box, 6/8 module complete all as specified and directed. |
| 12 | M&L for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB including removal old unsv one complete all as specified and directed. |
| 13 | M&L for Modular AC BOX with a two pin and earth plug and socket complete with one single pole MCB including removal old unsv one complete all as specified and directed. |
| 14 | M&L for AC plug top complete all as specified and directed. |
| 15 | S&F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and directed. |
| 16 | Material & labour for filling up & charging of R - 22/ R-32/ R-410 refrigerant or any type of refrigerant gas suitable to the existing AC unit as per site requirement for window/spilt type air conditioner of capacity 1.5TR, refrigerator and water cooler of capacity 80/40 litres after completion of leak testing of complete system and making good by bracing complete all as specified and directed. |
| 17 | M & L for Brazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, as directed and testing commissioning including taking down & refixing of out door unit in same or new location complete all as specified and directed. |
| 18 | M & L for repair / maintenance of Refrigerator/ water cooler of any capacity including replacement of minor parts as required , checking of electrical circuit, compressor etc complete all as specified and directed. |
| 19 | Supply & fix electric blower fan motor of split AC 230 volt 1340 RPM single shaft with ball bearing for any make split AC 1/1.5/2.0 Ton capacity complete all as specified and directed. |
| 20 | Supply & fix outdoor unit fan motor 1/20 HP 230 Volt Split AC of capacity 1.5 ton complete all as specified and directed. |
| 21 | Supply & fix new swing motor of same quality and charecteristics suitable for any make of AC 1/1.5 / 2.0 Ton split / window type |
| 22 | Supply & fix overload protector for split type AC of capacity 1.5 ton carrier make complete all as specified and directed. |
| 23 | Supply & fix running capacitor 35/45/50/55 MFD and complete all as specified and directed. |
| 24 | Supply & fix starting capacitor 100/120 MFD complete and complete all as specified and directed. |
| 25 | Supply & fix outdoor Stand for mounting of existing outdoor unit including anchor fastners of suitable size & model complete all as specified and directed. |
| 26 | S&F as in repairs new outdoor unit for 1.5 TR capacity Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired but with compressor, capacitor complete set complete all as specified and directed. |
| 27 | Supply & fixing hermetically sealed 1.5 TR compressor of same make as that of the existing for split AC with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed |
| 28 | S & F for thermostat switch of any make of split AC 1.5 ton capacity including removal of old existing unsv one complete all as specified and directed. |
| 29 | S & F for PCB (Printed circuit board) of normal unit suitable for existing 1.5 ton capacity split AC including removal of old existing unsv one complete all as specified and directed. |
| 30 | S & F for PCB (Printed circuit board) of inverter type unit suitable for existing 1.5 ton capacity split AC including removal of old existing unsv one complete all as specified and directed. |
| 31 | S&F for copper tubing of sizes 3/8\\" size for suction / discharge line of any make split AC of capacity 1.5 ton with rubber insulation of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed. |
| 32 | Description all as per item No 31.00 here in before but of 5/8” size complete all as specified and directed. |
| 33 | Description all as per item No 31.00 here in before but of 1/4\\" size complete all as specified and directed. |
| 34 | Description all as per item No 31.00 here in before but of 1/2\\" size complete all as specified and directed. |
| 35 | S & F \\"as in repairs\\" for indoor unit fan motor split type air conditioner 1.5 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display system of make as per existing including removal of old existing unsv one complete all as specified and directed. |
| 36 | Supply only universal remote suitable for the existing model AC's including 02 Nos of batteries complete all as specified and directed. |
| 37 | S & F for flexible PVC pipe 20 mm dia drain pipe from indoor unit including removal of old existing unsv one complete all as specified and directed. |
| 38 | S&F ODU fan blade for AC including necessary fittings as required complete all as specified and directed. |
| 39 | S&F Out door unit condensor copper coil 1.5 TR / 2TR for AC including necessary fittings as required complete all as specified and directed. |
| 40 | S&F Out door unit condensor copper coil 1.5 TR / 2TR inverter type for AC including necessary fittings as required complete all as specified and directed. |
| 41 | S&F Out door unit condensor copper coil Single pole contactor for Outdoor Units for AC including necessary fittings as required complete all as specified and directed. |
| 42 | S&F Coil sensor & frosting sensor for indoor units for Outdoor Units for AC including necessary fittings as required complete all as specified and directed. |
| 43 | M&L for vinyl label of standard size 4x6 cm of MES Number fix on cooling appliances complete all as specified and directed. |
| 44 | Supply, installation, testing and commissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and directed. |
| 45 | M & L for removing and shifting and re install of split type AC 1.5TR / 2TR from old location to new location including all types of necessary fittings and fabrication work as required while shifting and replacement of old damaged minor parts with the new one complete all as specified and directed. |
| 46 | M & L for insulation on copper pipe complete all as specified and directed. |
| 47 | M & L for Point wiring One light point controlled by one, one way switch 5 Amps with 1.5 Sq mm two single core copper conductor multistranded FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing surface type and accessories of suitable size ISI marked and terminal boxes modular type of 1.0 mm thick of suitable size including fixing/grouting modular surface box as per site requirement incl provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor FRLS PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified and directed. |
| 48 | Description all as per Srl item No 48.00 above One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator but complete all as specified and directed. |
| 49 | Description all as per Srl item No 48.00 above One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board but complete all as specified and directed. |
| 50 | Description all as per Srl item No 48.00 above One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. but complete all as specified and directed. |
| 51 | Description all as per Srl item No 48.00 above but using 2.5 sq mm Two single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point incl running of 2.5 sq mm multistranded copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and directed. |
| 52 | S&F Modular switch 1 way 6 A, 1 Module complete all as specified and directed. |
| 53 | S&F Modular switch 1 way 16 A, 1 Module complete all as specified and directed. |
| 54 | S&F Modular Socket 6A-2/3 pin combined 2 module complete all as specified and directed. |
| 55 | S&F Modular Socket 6A/16A-2/3 pin combined 2 module complete all as specified and directed. |
| 56 | Taking down old unserviceable and Supply & Fix new wall mounted LED 18/20 watts 6500 K with out put of 2100 lumens, box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with integral LED T8 tube 18/20 watts complete all as specified and directed. |
| 57 | Taking down old unserviceable and Supply & Fix new ultra bright LED Tubelight 18/20 watts 6500 K with out put of 1800 lumens (single side connection) with very high efficacy suitable for installation in existing tubelight G13 lamp holders to give glare free light with necessary wiring complete all as specified and directed. |
| 58 | Taking down old unserviceable and Supply & Fix new surface mounting 10 Watt LED fitting 2 feet batten type with extruded aluminium housing complete all as specified and as directed . |
| 59 | Taking down old unserviceable and Supply & Fix new 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 3600 total lumen.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection 2KV ,ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz ,The system efficacy must be between80-100 lumen /watt ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than 0.95 , THD < 10% . Indivisual LED's should not be visible for glare free output ,colour temperature 6500k complete all as specified and directed. |
| 60 | Taking down old unserviceable and Supply & Fix new post top lantern LED type 35 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 66 protection with impact and corrosion resistant complete with driver and lamp including 3 core multistranded flexible copper wire from connecting from junction box to post top light complete all as specified and directed |
| 61 | Taking down old unserviceable and Supply & Fix new bollard type LED type, 8 watt, 300lumens, warm white, 230 volts AC outdoor type with decorative bollard light IP 66 , Ik10 impact protection with impact and corrosion resistant including 3 core multistranded flexible copper wire from connecting from junction box to post top light complete all as specified and directed |
| 62 | Taking down old unserviceable and Supply & Fix new energy saving new generation 10 watts LED bulk head fitting IP 66 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of suitable size from ceiling rose to fitting complete all as specified and as directed. |
| 63 | Taking down old unserviceable and Supply & Fix new LED security light fitting 25 W, IP 66 rating, made out of pressure die cast aluminium powder coated housing high impact resistant 4 mm thick toughened glass cover and matrix of power LEDs in built electronic driver, fitted with adjustable pole adopter to enable on site tilt angle setting and input power 25 W system lumens 85/W operating voltage 160-260 V complete all as specified and directed. Note :(i) Rates are deemed to be included for security light brackets made out of GI light grade tubing of 1.5 meter length and bend to shape including fixing MS flat iron clamps, bolts & nuts as per site requirement |
| 64 | Supply & Fixing tricolor ((Amber-White-Green) LED strip light fitting 18 meter length, IP 65 rating, minimum 6 watt per meter including driver, connector and all necessary fixing accessories on street light poles from bottom to top of the pole with 3 core multistranded flexible copper wire from connecting from junction box to strip light complete all as specified and directed |
| 65 | S & F 1.5 Sqmm Copper Cable conductor PVC round sheathed (flexible) FRLSH cable complete all as specified and as directed |
| 66 | S & F 2.5 Sqmm Copper Cable conductor PVC round sheathed (flexible) FRLSH cable complete all as specified and as directed |
| 67 | S & F Rigid non-metallic PVC conduit/ casing caping of required size exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysNov 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender