Tender for Construction Of Boundary Wall Of Residence Of Honble Judge Of District Court Poonch(Under Untied)
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil : |
| 2 | Removal of unhygienic materials (so classified by the site engineer) from designated sites and its disposal as per directions, all inclusive |
| 3 | Dumping stone including cost of stones. On Horizontal on level. |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . All work up to plinth level with :1:5:10 ( 1 cement :5 coarse sand :10 graded stone aggregate 40 mm nominal size ) |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level including curing complete with:Cement mortar 1:6 (1 Cement : 6 coarse Sand).2nd Sort |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 8 | Foundations, footings, bases of columns etc. for mass concrete. |
| 9 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 10 | Steel work welded in built up sections/framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. |
| 11 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled withwhite lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 12 | Painting on G.S sheets with synthetic enamel paint of approved band and manufacture of required colour to give an even shade on New work (two or more coats) including a coat of approved steel primer but excluding acoat of mordant solution. |
| 13 | Carriage of material by M.T incl loading/unloading & stacking complete |
| 14 | Sand/Stone agg. below 40 mm nominal size avg. lead 11 Km by MT |
| 15 | Stone avg. lead 06 Km by MT |
| 16 | Earth Work avg. lead 03 Km by MT |
| 17 | Wiring for light point\fan point\call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor singel core casbel in furface \recessed medum class pvc conduit with modular switch , modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper comnductor singel cabel etc as req. |
| 18 | Wiring for light\power plug with 2x4 sq. mm FRLS PVC insulated copper conductor singel core cabel in surface\recessed medum class PVC conduit aslong with 1 no. 4 sq. mm. PVC FRLS insulated copper conductor singel core cabel in for loop earthing as req. |
| 19 | Wiring for cicuit/ submain wirring alongwith earth wire with the following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req |
| 20 | 2x1.5 sq. mm +1x1. sq.mm earth wire |
| 21 | 2x2.5 sq.mm+1x2.5sq.mm earth wire |
| 22 | 2x4.0sq.mm +1x 4.0 sq. mm rarth wire |
| 23 | Supply and drawing following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req |
| 24 | Supply and fixing of follo following size medum class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed comduit as req.25mm |
| 25 | Supply and fixing following modular switch/socket on the exisitying modular plate & switch box including connections but excluding modular plste etc. as req |
| 26 | 5/6 amp switch |
| 27 | 15/16 A switch |
| 28 | 3 pin 5/6 A socket outlet |
| 29 | 6 pin 15/16 A socket outlet |
| 30 | Supply and fixing two module steped type electronic fan regulator on exisiting modular plate switch box including connection bu excluding modular plate etc as req. |
| 31 | Supply and fixing modular blanking plate on existing modular plate &switch box excluding switch box etc. as,req. |
| 32 | Supply and fixing suitable G.I.box with modular plate and cover in front of surface or in recess, includijng providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc as req. |
| 33 | Supply and fixing suitable G.I.box with modular plate and cover in front of surface or in recess, includijng providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and15/16 A modular switch,connection ,painting,etc as req |
| 34 | Supply and fixing suiutable size of GI box with modular plate and cover in forent of surface or in recess,including providing and fixing 2 nos. 5/6 A modular socket outlet and 2 nos. 5/6 A modular swuitch, ,connection etc as rwq. (for light plug to be used in non residential buldings) |
| 35 | Supply and fixing following size/module GI. box alongwith modular base & cover plate for modular switches in recessed etc.as req.3 module (100mmx75mm) |
| 36 | Supply and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V. on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, intreconnection, powder painted including earting etc. as req. ( but without MCB/RCCB/isolator).4 way(4+12) Double Door |
| 37 | Supply and fixing 5 A to 32 A rating, 240/415 V, 10 KA, ''C'' curve ,miniature circuit breaker suitable for inductive load of following pole in exisiting MCB DB complete with connection, teasting and commessoning etc. as req. |
| 38 | Single pole |
| 39 | Single Pole and Neutral |
| 40 | Supply,Installation , Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 150 CM/Min (Minimum) |
| 41 | Providing and fixing of IP-20 SMD mid powerLED batten type integrted light fixture made from power coatedExtruded alum. housing with in built driver, complience 2.5 KV surg protected isolated driver, with short and open circuit protection .having efficiency .85% system lumin efficacy of ≥110 lm/ Watt,THD< 10%, PF ≥ 0.95, Cri.80, life time of minimum 50000 Burning Hours with 70% of intial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°k/6000°/6500°K(A per ANSI Bin) , maximum power consumption should not more then the specified rating and fixture shell be of BIS standard and teade mark certificate (T.C) Manufacture word Mark / Name Engraved/Embossing/Screen Printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 &Lm80) certificate /report from OEM shall be submitted. all as per approved by EIC. 20/22 Watt LED 4 feet with min. lumen output (2000-2200) lm |
| 42 | Supply and fixing of following electrical items as req |
| 43 | A/B holder |
| 44 | LED lamp 9 watt |
| 45 | supply, instalation of 16.0 sq mm twin core alum wire |
| 46 | supply,installation,tasting and commessoning of 200 Ah 12 V Batery Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender