Tender For Construction Of Control Room Building At 190Mva 132/33 Kva Grid Sub Station At Wanpoh On Existing Building Estimated Cost Lacs 196.58
Tender Value
1.96 Crore
Estimated cost
Bid Submission
10 Nov 2026
7 days left
EMD
3.93 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Control Room Building At 190Mva 132/33 Kva Grid Sub Station At Wanpoh On Existing Building Estimated Cost Lacs 196.58
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of existing |
| 2 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 3 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead a) Of area of 3 sqm. and below Of area beyond 3 sqm. |
| 4 | b) Big windows |
| 5 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. |
| 6 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge |
| 7 | Construction of Main Building |
| 8 | Engagement of Labor for site Clearance and al;l work as per the direction sof incharge engineer at site |
| 9 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil |
| 10 | Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified grade concrete M30 design mix, 450mm diameter and 15m length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embeded in the pile cap etc. all complete including removal of excavated earth with all lifts and leads(Length of pile for payment Shall be measured from top of shoe to the bottom of pile cap) By percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, 450 mm dia piles |
| 11 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer-in Charge. Routine test (Test Load 1.5 times the safe capacity) |
| 12 | Providing and laying of stone soling, hand packed, including carriage of same from approved source upto site of work complete. |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:4:8 (1Cement: 4 fine sand: 8 grade stone aggregate 40mm nominal size) |
| 14 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level |
| 15 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 16 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with:1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:2:4 (1Cement: 2 fine sand: 4 grade stone aggregate 20mm nominal size) |
| 19 | Centering and shuttering including strutting propping etc. removal of form work in Foundations, footings, bases of columns etc. for mass concrete. |
| 20 | Centering and shuttering including strutting propping etc. removal of form work in Columns, pillars, piers, abutments, posts and struts. |
| 21 | Centering and shuttering including strutting propping etc. removal of form work in Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 22 | Centering and shuttering including strutting propping etc. removal of form work in Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 23 | Centering and shuttering including strutting propping etc. removal of form work in Suspended floors, roofs, landings, balconies and access platforms |
| 24 | Centering and shuttering including strutting propping etc. removal of form work in Edge of Slabs |
| 25 | Reinforcement of RCC works including straightening, cutting, bending placing in position and binding all complete. Mild steel and medium tensile steel bars. |
| 26 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m |
| 27 | Providing and laying Boulder / GSB / Sand filling of including all carriages of material complete |
| 28 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in In cement mortar 1 cement: 6 fine sand mortar. |
| 29 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 30 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 31 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 32 | Providing and Laying of 40mm thick concrete flooring in rooms in M-15 (1:2:4) nominal mix (max size of aggregate 20mm) concrete. |
| 33 | Providing and applying average 12 mm thk cement plaster in single coat incement sand mortar 1:6 to all surfaces at all levels including surface preparation, staging, scaffolding as directed. |
| 34 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm anti skid. |
| 37 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.d curing complete as per the directions of engineer-in-charge.2 mm thick |
| 38 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour or shade 16mm thick |
| 39 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 40 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class imported kail wood |
| 41 | Providing and Fixing of 40 x 5mm MS Hold Fast 40cm Long including fixing to frames embedded in cement concrete block in 1:3:6 Mic including all carraiges. |
| 42 | Providing and fixing 35mm Thick panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge First class kail wood |
| 43 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside rooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. First Class kail wood |
| 44 | Providing and fixing glazed 35mm Thick shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws First class kail wood |
| 45 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood |
| 46 | Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture . |
| 47 | Providing and fixing of the following Hardware fittings. |
| 48 | Brass Handle 12\\" Long |
| 49 | Brass Handle 9\\" Long |
| 50 | L- drop 12\\" Long |
| 51 | Tower Bolt 9\\" Long |
| 52 | Tower Bolt 6\\" Long |
| 53 | Handle 6\\" mm |
| 54 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 55 | Providing and fixing of 0.5mm thick colour coated high rib iron profile sheets of approved profile as approved by Engineer-in-Charge in roofing including carriage of same upto site of work complete. The sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 mtr or as directed by Engineer-in-Charge. The sheet shall be fixed using self drilling /self tapping screws of size(5.5 x 55mm) with EPDM seal of same colour matching the shade of the sheets. including ridges valleys eaves of matching colour |
| 56 | Providing and fixing of Powder coated ridges or hips of matching colour of width 30cm over all width plain G.I sheet fixed with nails |
| 57 | Providing and fixing of planed eaves boarding 250x32 mm (nominal size) size of 2nd class kail wood |
| 58 | Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (The rate is excluding the cost of tiles which will be paid for separately). 12.64.1 GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 59 | Providing and fixing of 10mm thick Ready made wooden Panneling in sofits including cost of Budloow Wood Frame Work 50 x 40mm Section @ 600mm c/c bothways including cost of screws, etc in Softs, walls, gables, etc complete as per directions of engineer in charge. |
| 60 | Providing and laying of Dry random rubble masonry with hard stone in foundation and plinth using quarry stone. |
| 61 | Construction of brick masonry man hole in cement mortar 1:4 (1 cement: 4 coarse sand) , foundation concrete (1:4:8) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size finished with a floating coat of neat cement complete. Size 45 x 45 x 45cm deep including PVC manhole cover with frame. |
| 62 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.( of approved brand and manufacturing) |
| 63 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 64 | Providing and fixing of PVC pipe (Type “B”) in proper gradient. |
| 65 | 150mm Dia |
| 66 | 100mm Dia |
| 67 | 75mm Dia |
| 68 | 100mm Dia Plain Bend |
| 69 | 100mm Dia Door Bend |
| 70 | 100mm Dia Plain Tee |
| 71 | 100mm Dia Door Bend |
| 72 | Reducer 100mm to 75mm |
| 73 | 75mm Dia Plain Bend |
| 74 | 75mm Dia Floor Trap |
| 75 | Providing and placing on terrace (at all floor levels) polythene water storage tank with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but excluding all fittings and the base support for tank |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc 20mm nominal outer dia pipes. |
| 77 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc 25mm nominal outer dia pipes. |
| 78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc. 32mm nominal outer dia pipes. |
| 79 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 80 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 81 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg |
| 82 | Providing and fixing of Two in One Angle Valve of approved make including all accessories complete. |
| 83 | Providing and fixing of Wall Mixer of approved make including all accessories complete. |
| 84 | Providing and fixing of Health Fuacet with chain of approved make including all accessories complete. |
| 85 | Providing and fixing of CP Towel Rod 600mm Long of approved make including all accessories complete. |
| 86 | Providing and fixing of CP Soap Case of approved make including all accessories complete. |
| 87 | Providing and fixing of CP Connection 600mm-450mm long of approved make including all accessories complete. |
| 88 | Providing and fixing of CP Grating of approved make including all accessories complete. |
| 89 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in- charge. |
| 90 | Providing and fixing of Stain less steel paper holder with stand of approved make including all accessories complete. |
| 91 | Providing and fixing of the 300mmx 300mm Exhaust Fan (Crompton Make) as per approved specifications, complete. |
| 92 | Providing and fixing of 1.0 hp unidirectional flow motor of kirloskar or equivalent make and as per relvan IS specifications including all fittings viz; inlet & outlet connections & electric fittings complete as directed by Engineer incharge |
| 93 | Providing and fixing of 50 Ltr water heater (geysers) of approved make including cost of dash fasteners with nuts and washers, complete. |
| 94 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 95 | Supply and laying of manhole frame and cover Cast Iron heavy duty (2'-0\\" x 2'-0\\") of specified design and dimensions as directed by Engineer In Charge |
| 96 | Carriage of material by mechanical means. |
| 97 | Sand 15 km |
| 98 | Aggregates 15 km |
| 99 | Stone Solling (12 Km) |
| 100 | Bricks (20 Km Lead) |
| 101 | Electrification |
| 102 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 103 | Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. |
| 104 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. |
| 105 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 106 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Metre |
| 107 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 108 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 109 | Supplying and fixing Modular Blanking Plate on the existing Modular plate & Switch Box excluding modular Plate as required |
| 110 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 111 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 112 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 113 | 6 way (4 + 18), Double door |
| 114 | 12way (4 + 36), Double door |
| 115 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. |
| 116 | 12 way , Double door |
| 117 | Supplying and Fixing of Following Ratings of D.P MCB 240 Volts \\"C\\" Series in the Existing MCB D.B complete with connections,Testing and Commissioning Etc. as Required. |
| 118 | 63A D.P MCB 10 Ka \\"C\\" Curve |
| 119 | 16 A D.P MCB 10 Ka \\"C\\" Curve |
| 120 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 121 | 63 A F.P MCB 10 Ka \\"C\\" Curve |
| 122 | Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 123 | Single Pole |
| 124 | Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required. |
| 125 | Supplying,Installation,Testing and Commissioning of G.I Earthing Electrode of Size 50 x 3000mm with GI Pipe Outer Dia. 58 mm (+-) 5 %,Length 3000 mm,Inner & Outer GI Strip Size 32X6mm,Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs. |
| 126 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 127 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 128 | Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of Metal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required . |
| 129 | 300 mm |
| 130 | Supply installation testing and commissioning of IP20 led downlighter 15 W-18 W +/- 1 W LED Surface downlighter round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab . |
| 131 | Supply, Installation, Testing and Commissioning (SITC) of 01 No. 1.5 Ton, hot and cold, 3-Star rated split-type Air Conditioner of standard reputed make, complete with suitable-capacity voltage stabilizer for installation in the office of the Assistant Executive Engineer (AEE) including the dismantling, servicing, and reinstallation of 07 Nos. existing Air Conditioners installed in the Control Room |
| 132 | Supply installation testing and commissioning of IP:20 Aluminium Batten 40 W +- 1 W LED Surface Mounted 4 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 133 | Providing, fabricating, supplying and fixing of LED-illuminated, weather-resistant Aluminium Composite Panel (ACP) signboards for the main entrance gate of the Grid Sub-Station, Control Room Building and office of the Assistant Executive Engineer (AEE) and fixing of high-quality ACP room nameplates indicating the names of various rooms( as per the directions of Engineer Incharge) |
| 134 | Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Main Distribution Panel ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved. INCOMER Adj. TMR Based MCCB 100 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH (02 Nos) Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar( 150 Amps ) , MCB Strip,Indicating Lamps,Multifunction Meter,Ammeter,Voltmeter etc. of suitable size as Required.(Refer SLD for Interlocking) OUTGOINGS Manual Changeover 100 A F.P A.C -23 Duty(01 Nos) 63 A F.P MCB 10 Ka \\"C\\" Curve(04 Nos) 16 A D.P MCB 10 Ka \\"C\\" Curve(02 Nos) Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick. |
| 135 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 136 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.3.5 C X 70 Sq.mm A2XFY |
| 137 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) 3½ X 70 sq. mm (38mm) |
| 138 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 139 | Telephone socket outlet |
| 140 | Computer Socket RJ45 Modular type |
| 141 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 142 | 1 or 2 Module (75mmX75mm) |
| 143 | Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required. |
| 144 | 20 mm PVC Conduit |
| 145 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 146 | 2 Pair |
| 147 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable |
| 148 | Supply & Erection of lockable 12 U rack with 5A strip and two fan for distribution, mounting of patch panels, hubs, switches etc,, complete as per specification and as desired by EIC. |
| 149 | Supply & Erection of CAT 6, 16 port Jack panel for termination of CAT6 cable,Testing & certification of the network with Omni/Penta Scanner of each Cable. |
| 150 | Supply & Erection of Cat-6, 1Mtr Patch Cords complete as per specification and as desired by EIC. |
| 151 | Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC |
| 152 | Supply, Installation, Testing and Commissioning of 10/100/1000 Mbps Unmanaged Switches with Provision of 16 10/100/1000 Mbps ports as per specification and as desired by the Engineer Incharge. |
| 153 | Supply,Installation,Testing and Commissioning of Media Converter. |
| 154 | Supply & Erection of Termination Box complete as per specification and as desired by EIC. |
| 155 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T Compliant, UL/CSA, CE, FCC, EN, RoHS & NDAA Section 889 compliant. |
| 156 | Supplying and Laying of 20 Mtr HDMI Optical Fiber Cable AOC 2.0, 4K with Bandwidth 18Gbps |
| 157 | Supplying and Fixing of S.D Card 256 G.B in the Existing Camera |
| 158 | Supply & Erection of CAT 6, 16 port Jack panel for termination of CAT6 cable,Testing & certification of the network with Omni/Penta Scanner of each Cable. |
| 159 | Supply & Erection of Cat-6, 1Mtr Patch Cords complete as per specification and as desired by EIC. |
| 160 | Supplying,Installation,Testing and Commissioning of 55 Inches Ultra HD 4K LED Display Monitor with 3840 x 2160 pixels (Min.) |
| 161 | Supply , Installation , Testing and commissioning of 16 Channel NVR (Network Vedio Recorder) Embadded Linux based for recording upto 16CH @ D1 with 02 nos. SATA HDDs minimum 20TB storage or more (recording requirement all cameras recording at D1, 25fps for 30 days), H.265 HEVC/H.264/MJPEG codec decoding, Front Control Pannel with LEDs Indication, 2 nos. USB, ONVIF S, Time Sync with NTP, Encrypted Streaming & Control, 2-Way Audio Line & Out, PTZ Operation Pan, Tilt, Zoom, Support, Pre & Post Alarm Recording Support, Recording/Evidance Clip Export to USB, 16 Channel Syncronous Playback, Playback control i.e Play, Pause, Stop, Fast Forward, Backward, Timeline & Zoom; Snapshot, Web Client, Central Monitoring Softawre, iPhone; iPad; Android based Mobile clients, 01HDMI & 01VGA Output, 02 On Board HDDS each up to 10TB, Alarm Input (1 nos.), Alarm Output (01 nos.), NDAA Section 889 Compliant, Operating Temperature –10°C to 55°C, Certification : Certifications: ONVIF compliant, UL/CSA, CE, FCC, EN, NDAA & RoHS compliant.including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge. |
| 162 | SITC of 10TB 7200 rpm SATA 6 Gb/s 3.5\\" Internal Enterprise Hard Drive Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender