Tender For Supply, Installation, Testing & Commissioning (Sitc) Of Energy Storage System
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Nov 2026
10 days left
EMD
1.11 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing & Commissioning (Sitc) Of Energy Storage System
BOQ
| Sl. No. | Item Description |
| 1 | Design, manufacture, supply and irection of structurally sound, high-load-bearing and modular battery rack systems fabricated from Mild Steel (MS)/Carbon Steel sections, using L-angle/square sections of size 40 × 40 × 4 mm or suitable equivalent section as per the required load capacity and site compatibility. The scope shall include cutting, drilling, welding, grinding, fabrication, leveling, alignment, provision of suitable supports/bracing and anchoring arrangements, as required at site. Suitable heavy-duty rubber pads of adequate thickness and load-bearing capacity shall be provided below the battery rack/supporting contact points to provide load isolation, minimize vibration and prevent direct metal-to-floor contact. The complete rack shall be properly surface-prepared, treated against corrosion and finished with durable powder coating. The rack shall be designed to safely accommodate the specified battery quantity and load, with adequate structural strength, stability, ventilation and accessibility for inspection and maintenance. The work shall be complete in all respects as per the approved design, site conditions and Engineer-in-Charge's instructions. |
| 2 | Supply, laying & testing of Single Core, 95 sq. mm, 1100 V grade, FRLSH, multi-stranded, flexible copper conductor cable conforming toIS 5831:1984 (latest) with ISI mark, PVC insulated, sheathed, erected on provided wall/ trusses/pole/cable trays /trench/ pipe suitable for industrial use, including necessary fixing arrangements, Cable ties & Cable management, ferrules, dressing, and testing as required at site. |
| 3 | Termination of Single Core, 95 sq. mm, 1100 V grade, FRLSH, flexible copper conductor cable using suitable tinned copper crimping lugs & heavy duty cable gland (IS:12943) at panel end (IS:8309/IS:8337), including cutting, stripping, dressing of cores, crimping, fixing, earthing, tagging, and making complete termination at both panel and user end as required at site. |
| 4 | Supply, Installation, Testing & Commissioning of 12 Volt, 160Ah, Factory charged SMF VRLA Batteries including all required connectors/fastners for interlinks, battery tags, seperators, terminal covers etc. complete as instructed by the engineer In-charge. |
| 5 | Supply, Installation, Termination & Testing of interlinks of single Core, Annealed Tinned Copper Conductor, Uninyvin cables rated for constant discharge current of 10 min of 160Ah battery & at least rated for 340 Ampere DC current conforming to IEC 60228 / IS 8130. Interlinks should be Heat Resistant for 105°C HR-PVC insulation cables with Fiber Glass, Nylon Braided Nylon Lacquering complete with appropriately sized crimped copper lugs at both ends, suitable fasteners (SS/brass as required) such as nuts, bolts, washers, etc. and all necessary accessories for secure termination and interconnection between individual batteries and battery banks, including routing, dressing, identification and making the system complete in all respects as required at site. (The length of the Interlinks shall be selected based on feasibility, ease of maintenance & handling, accessibility. The proposed cable routing/layout shall be submitted to IUCAA for review and approval prior to execution. The final cable size, length, routing, and installation arrangement shall be approved by the IUCAA Engineer, considering future maintenance requirements and ease of handling.) |
| 6 | Supply, Laying & Testing of single Core, Annealed Tinned Copper Conductor, Uninyvin cable rated for constant discharge current of 10 min of 160Ah battery & at least rated for 340 Ampere current, conforming to IEC 60228 / IS 8130, including routing, dressing, identification marking/tagging into the provided cable trench/trays and making the system complete in all respects as required at site. The cables should be Heat Resistant for 105°C HR-PVC insulation cables with Fiber Glass, Nylon Braided Nylon Lacquering |
| 7 | Supply, termination and installation of appropriately sized crimped copper lugs for the Uninyvin cables provided under the BoQ item number 6 above, including suitable SS/brass nuts, bolts, washers and other necessary accessories for secure termination and interconnection between switchgears, UPS systems and battery banks. The work shall also include the supply and installation of suitable PVC/brass cable glands at panel end cable terminations, complete in all respects as per cable size, equipment requirements and site conditions. |
| 8 | Disassembling, Shifting, Transportation & erection of two (2) ABB make 250 kVA UPS racks with loaded modules and one (1) Electrical DC Fuse Board (approx. 5 ft × 4 ft) from IUCAA to the Aditi Basement Room, approximately 800 Mtr. distance, including all necessary manpower, tools & tackles, crane/ lifting equipment, transportation, loading/unloading, handling, shifting and required accessories for safe execution of the work. The work shall be completed in all respects as per site conditions and requirements. |
| 9 | Overhauling of 2 Nos. ABB make, 250 kVA UPS systems along with all installed/loaded power modules, including complete cleaning, tightening of all electrical and mechanical connections, modules, control cards, cooling fans, busbars, terminals, cables and associated components; internal and external inspection of UPS panels, identification and rectification of loose connections, dust accumulation and other minor defects; and carrying out necessary servicing in accordance with the manufacturer's recommendations/guidelines and applicable relevant standards, |
| 10 | Positioning, Assembly, Reconnection, Commissioning, Synchronisation & Testing of the two (2) ABB make 250 kVA UPS systems with loaded modules, along with the associated supplied battery banks, at the designated shifted location. The work shall include all equipment and accessories required for commissioning & synchronisation as per applicable UPS/OEM standards and site requirements. The work shall be executed in presence of the OEM/authorised ABB service representative, including necessary functional checks, checking of electrical parameters, health condition and functional performance of individual modules, and battery systems. The work shall be completed in all respects to run both UPS in parallel. |
| 11 | Installation on wall, positioning, assembly and reconnection of the existing Electrical DC Fuse Board (approx. 5 ft × 4 ft) at the designated shifted location. The DB shall be installed with required fastners and as per applicable electrical safety standards and site requirements, followed by checking, testing, insulation resistance testing and functional verification of all outgoing/incoming circuits. |
| 12 | Supply, laying & testing of Single Core, 70 sq. mm, 1100 V grade, FRLS multi-stranded, flexible copper conductor cable conforming to IS 5831:1984 (latest) with ISI mark, Green colour, PVC insulated, sheathed, erected on provided wall/ trusses/pole/cable trays /trench/ pipe suitable for industrial use, including necessary fixing arrangements, Cable ties & Cable management, ferrules, dressing, and testing as required at site. |
| 13 | Termination/Jointing of Single Core, 70 sq. mm, 1100 V grade, FRLS flexible copper conductor cable using single compression cable gland (IS:12943) at panel end and suitable tinned copper crimping lugs (IS:8309/IS:8337), including cutting, stripping, dressing of cores, crimping, fixing, earthing, tagging, and making complete termination at both panel and user end as required at site. |
| 14 | Providing & erecting hot dipped galvanised perforated/ ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 15 | Providing & erecting hot dipped galvanised perforated/ ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 16 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. |
| 17 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware. |
| 18 | Supply, installation, testing and commissioning of an integrated UPS Remote Alarm Panel, suitable for receiving potential-free contact signals from the UPS and providing local audible and visual alarm indications. The panel shall operate on 100–270 V AC supply and shall be suitable for wall mounting in a metal enclosure. The system shall include potential-free contact inputs for visual LED indications of Load ON Battery, Mains ON, Inverter ON and Inverter Trip status/alarm signals from the UPS, with suitable interface circuitry, indication LEDs, buzzer and alarm acknowledgement facility. The complete system shall include all necessary SMPS/power supply, relays/interface modules, terminal blocks, wiring, MCBs, connectors, push buttons, LEDs, buzzer and internal accessorie as required for complete and reliable operation |
| 19 | Supplying Two sets of all required advanced Communication cables From UPS units to Remote Alarm Panels (suitable for or supplied UPS Remote Alarm Panel in BoQ item no. 18) with laying, crimping, terminating at both ends with all required lugs and gland. |
| 20 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV (Raychm, Jyoti Duratuf or equivalent) |
| 21 | Supply of NH FUSE 500A 500V, 500NHG3B LV, NH3, gL/gG Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender