Metro Rail Boards / Undertakings / PSU Closing in 3 days TDR #58125414

Tender For Repair & Replacement Of Miscellaneous Electrical Work At L-2, L-3 And Various Pump Room Of Dmrc.

Issued by Boards / Undertakings / PSU · New Delhi, Delhi
Tender Value
58.56 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
3 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair & Replacement Of Miscellaneous Electrical Work At L-2, L-3 And Various Pump Room Of Dmrc.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 10-Nov-2026 Addendum 1 Date 16-Nov-2026

BOQ

Name of Work:- Repair & Replacement of miscellaneous electrical work at L-2, L-3 and various Pump Room of DMRC.
Sl. No. Item Description
1Total of Schedule-A + Schedule-B
2Total of Schedule-A
3Total of Schedule-B OEW-2328 APPENDIX- 3A PROFORMA FOR STATEMENT OF MINOR DEVIATIONS (Refer Clause C 2.2(d) and C 15.1 of ITT) 1. The following are the particulars of minor deviations from the requirements of the Tender Document: Sr. No Clause Deviations Price reduction for each deviation/s Note : 1. The Tenderer shall indicate price reduction against each deviation in Appendix-3A of BOQ. This price is the price which the tenderer shall reduce from this tender price if deviation(s) is/are accepted by the Employer. 2. Where there is no deviation, the statement should be returned duly signed with an endorsement indicating ‘No Deviations’. In case, Performa of deviations is not submitted or submitted as blank, it will be construed that the tenderer has not proposed any deviations from tender documents. 3. It shall be noted that in case Nil/Zero/NA Price quoted by Tenderer in Appendix-3A then it shall mean that contractor has quoted same price for deviation and undeviation bid. 4. If the tenderer proposes deviations in tender documents, and/or any other terms and conditions of the tender, other than in this Appendix, it will have no effect. Signature of authorized signatory On behalf of Tenderer OEW-2328 BOQ Preamble
4The bill Quantities shall be read in conjunction with Notice Inviting Tenders, Instructions to tenderers, General and Special Conditions of Contract, Employers Requirements and other relevant documents
5BoQ consists of two schedules i.e. Schedule-A & Schedule-B as detailed in Tender documents.
6The rates and prices to be tendered in the unit Priced Bill of Quantities are for completed and finished items of works and complete in all respect. It will be deemed to include Duties, Taxes, Octroi, Royalty etc., cost of all plants, labour, supervision, materials, transport, all temporary works, erection, maintenance, utility identification, contractor’s profit and establishment/ overheads, together with preparation of design and drawings, all general risks, insurance liabilities, compliance of labour laws and obligations set out or implied in the contracts. For taxes and duties refer clause C2.4 & C2.5 of ITT & clause 10 of SCC.
7Tenderers shall quote their offer in Indian Rupees (₹) only. Tenderers are required to quote percentage (%) (Excess/Less) in figures in the appropriate highlighted cells in Excel sheet namely 'BoQ1' against given schedules.
8If the tenderer fails to quote percentage against BOQ item, the tender may be treated as incomplete and non- responsive and shall be rejected.
9Errors will be corrected by the employer for any arithmetical errors in computation or summation as per contract conditions.
10The Financial Proposal (as per BOQ) shall be uploaded online on the website https://etenders.gov.in/eprocure/app. The rates/ percentages shall be quoted in the excel file provided in the bid documents. The tenderer shall download the excel file and quote percentage in figures against BOQ amount in the appropriate highlighted cells in Excel sheet namely \\"BoQ1\\". After quoting their rates the excel file shall be uploaded accordingly. The rates shall not be offered/quoted elsewhere in the technical submission/ tender submission.
11The work executed against all the BOQ as detailed in tender document would be paid as per relevant clause of Employer's Requirement (ER).
12The price offer in BOQ shall be given without consdering any deviation mentioned in Appendix-3 of FOT i.e. price in this box shall be quoted as per tender condition without any deviation. Please Enable Macros to View BoQ information Delhi Metro Rail Corporation Limited Bill of Quantity Name of work- OEW-2328 \\"Repair & Replacement of miscellaneous electrical work at L-2, L-3 and various Pump Room of DMRC.\\" S.No. Description of work Unit Qty Unit rate (INR) Amount (INR) Schedule-A Cabling
13Supplying, drawing & Commissioning of following sizes of Copper conductor Armoured LSZH cable PVC insulated sheaathed armoured XLPE power cable of 1.1 KV grade in the existing surface/recessed steel/PVC conduit as required through trench shaft/undercroft/utility shaft etc a. 3 Core 10 Sq mm mtr 2500.0 750.0 1875000.0 b. 4 Core 25 Sq mm mtr 500.0 2075.0 1037500.0 c. 3 Core 06 Sq mm mtr 500.0 246.13 123065.0 d. 8 core 01 sqmm mtr 400.0 283.0 113200.0
14Supplying and making end termination with brass double compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. a. 3 Core 10 Sq mm nos 100.0 450.0 45000.0 b. 3 Core 6 Sq mm nos 15.0 300.0 4500.0 c. 4 Core 25 Sq mm nos 40.0 473.0 18920.0
15Supply, laying and commissioning of PVC insulated FRLSZH, single core copper condutor wires and its termination in the existing GI conduit of the following sizes as per ISS/IE rule and site condition. a. 6 sqmm mtr 500.0 328.0 164000.0
16Supply and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc as required a. 160 Amp nos 1.0 8000.0 8000.0 b. 250 Amp nos 1.0 12359.0 12359.0
17Supplying and fixing following rating, double pole, (Single phase and Neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a. 10 Amp nos 20.0 2000.0 40000.0
18Supplying and fixing following rating, four pole, (three phase and neutral), 415V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required a. 32 Amp nos 20.0 3366.0 67320.0
19Supplying and fixing following rating, double pole, (Single phase and Neutral), 240V, Residual Current Breaker with Overcurrent (RCBO), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a. 40 Amp nos 12.0 2535.0 30420.0
20Supplying and fixing following rating, double pole, (Single phase and Neutral), 240V, Electronic Overload Circuit Relay (EOCR), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a. 1.2A - 7A nos 2.0 2453.0 4906.0 b. 25A nos 2.0 3972.0 7944.0 c. 60A nos 2.0 4546.0 9092.0
21Supply and fixing of three-pole, 230V, LC1D25 contractor designed for motor control and switching load complete with connections, testing and commissioning etc as required. a. 25 Amp nos 20.0 5201.0 104020.0
22Supply & fixing of current transducer RANGE- 4-20mA Output- 0-10V DC suitable for PLCs. data logger & control system
23Supply & fixing of voltage transducer RANGE- 4-20mA Output- 0-10V DC suitable for PLCs. data logger & control system
24SITC of AE make watt transducer (3P-3E-4W), Input - 0-3810.4 WRange- 0-1280 KW, PTR- 440 V, CTR- 1600 / 5 AOutput 1&2- 4 - 20mA DC AT 500 ohmsaccuracy + - 0.5 %Aux. Supply- 240 VAC
25SITC of Converter Module for DG Set - INPUT- DC Ma, RANGE- 4-20 mA, Output- 0-10 VDC, Isolation - 3 Point Aux. Supply 24 VDC.
26Supply and installation of 3 phase 415 volt with 5 point R,Y,B,N,G for earth, IP rating = 65, with four pole MCB, industrial power socket 100/125 ampere. Total Amount of Schedule-A (Excluding GST) 4527714.0 GST @ 18% 814988.52 Total Amount of Schedule-A (Including GST) 5342702.52 Schedule B: Repair of existing electrical panel
27SITC of Electrical panel lock size -15-20 mm material-Stainless steel & silver finish Lock type- Pin type
28Supply & Replacement of Electrical panel hinges including welding work (Hinge should be Screw mounted having two round hole ,Material-stainless steel, Min Size- 41x36(LxW)
29Supply & Replacement of Electrical panel doors/cabinet Rubber Gasket to make panel dust and Vermin Proof. (Dia- 15mm or as per site condition).
30Supply & Replacement of rusted MS steel sheet of electrical panel with complete welding and screw tightening as per site requirement having thichness 14 gauge.
31Supply & Replacement of transparent fibre sheet with rubber bidding for window/vision panel with their respective fittings. (thickness- 4mm or as per site requirement). Note: size of fibre sheet may vary at different site.
32Supply & fixing of terminal block (Voltage rating- 600V, Current rating- 15A-65A, wire size- 0.5 - 4.0 mm2, panel mount type with scre tighten, IP-65) a. 05 Amp nos 200.0 150.0 30000.0 b. 16 Amp nos 200.0 200.0 40000.0
33Providing and laying in position cement concrete of 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources.
34Supply, fabrication, cutting, welding , finishing , fixing of MS base channel frame made with ICMC 125 X65X5 M.M channel incl. suitable size of hole for fixing of angle frame incl. nuts, bolts ,plain and spring washers etc.
35Supply,installation, testing & commissioning of three phase 100 AMP bus bar box size- approx 2 ft x1.5 ft x1ft made out from 18 SWG MS sheet duly painted with grey powder coated paint with locking arrangements including channel & RCC foundation work as per site condition.
36Supply, installation, testing and commissioning (SITC) of 5/7.5 HP borewell (submersible pump) control panel suitable for 3-phase, 415V, 50Hz AC supply, comprising of suitable rating MCCB/Isolator as incomer, DOL/Star-Delta starter (as per motor rating), contactor, thermal overload relay, single phasing preventer, voltmeter with selector switch, ammeter with selector switch and CTs, indicating lamps, control fuses, push buttons (start/stop), auto/manual selector switch, and all necessary control wiring. The panel shall be made of CRCA sheet steel, dust and vermin proof, powder coated, wall/floor mounted as required, with proper earthing terminals. The panel shall include all interconnections, cable termination, glands, lugs, and accessories required for complete operation of the borewell submersible pump
37Supply, Installation, testing and commissioning of water level SENSOR with water level INDICATOR in PTM underground water tank for four level i.e. 25%,50%75%100%. Total Amount of Schedule-B (Excluding GST) 435034.2 GST @ 18% 78306.16 Total Amount of Schedule-B (Including GST) 513340.36 Total Amount of Schedule-A & B (Excluding GST) 4962748.2 Total Amount of Schedule-A & B (Including GST) 5856042.88

AI Tender Summary

OUR REF NO 58125414
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 58.56 Lakhs
LAST DATE 16-11-2026
Authority
Authority Name Delhi Metro Rail Corporation Limited
Work Description Tender for Repair & Replacement Of Miscellaneous Electrical Work At L-2, L-3 And Various Pump Room Of Dmrc.
Basic Detail
Tender No OEW-2328
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 10 Nov 2026
Submission Date 16 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 58.56 Lakhs
Tender Fee 5900
EMD 1 Lakhs
Exemption Not Available
Document List
bcf89c9f-59b4-421a-95f9-221aa2f50e0c.html
BOQ_343140.xls
TenderDoc.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

bcf89c9f-59b4-421a-95f9-221aa2f50e0c.html

xls

BOQ_343140.xls

rar

TenderDoc.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender