Tender For Laying Of Pipeline For Connecting The Exising Pri Pond At Chidiyatapu, Near The Community Hall, To The Chidiyatapu Water Treatment Plant (Wtp), Including Connecton Of The Hill Top Check Weirs To The Pri Pond, Along With Construction Of A P
Tender Overview
Project Description
Tender for Laying Of Pipeline For Connecting The Exising Pri Pond At Chidiyatapu, Near The Community Hall, To The Chidiyatapu Water Treatment Plant (Wtp), Including Connecton Of The Hill Top Check Weirs To The Pri Pond, Along With Construction Of A Pump House.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 5 | Columns, piers, abutments, pillars, posts and struts |
| 6 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 7 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work |
| 8 | PN - 10 Pipe, 90 mm OD (SDR-11) |
| 9 | PN - 10 Pipe, 110 mm OD (SDR-11) |
| 10 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work |
| 11 | 80 mm dia nominal bore |
| 12 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 13 | 50 to 80 mm nominal bore |
| 14 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 15 | 80 mm nominal bore |
| 16 | Providing and fixing gun metal non- return valve of approved quality (screwed end) :Horizontal |
| 17 | 80 mm nominal bore |
| 18 | Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : |
| 19 | Up to 300 mm dia |
| 20 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : |
| 21 | 100 mm diameter Class II |
| 22 | 150 mm diameter Class II |
| 23 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 24 | 80 mm diameter pipe |
| 25 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
| 26 | 80 mm nominal bore |
| 27 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : |
| 28 | 80 mm dia |
| 29 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : |
| 30 | 100 mm dia nominal bore |
| 31 | Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : |
| 32 | 100 mm dia |
| 33 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipe fitting Flange Core of size 90 mm. |
| 34 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipe fitting Flange Core of size 110 mm. |
| 35 | Providing and Fixing 3 Layer PP-R (Poly Propylene Random Copolymer) pipe fitting Flange of size 90mm |
| 36 | Providing and Fixing 3 Layer PP-R (Poly Propylene Random Copolymer) pipe fitting Flange of size 110mm |
| 37 | Supplying, Installation, Testing and Commisssioning of diesel water pump set comprising of Kirloskar make water-cooled diesel engine Model TV2, 16HP at 1800 RPM or its equivalent, coupled with Kirloskar make pump model 16 SR 6 pump, 6-stage, or its equivalent having suction and delivery 80X65 mm dia for pumping to total head of 95 meter at discharge to total head of 95 meter at discharge rate of 4 LPS with CI impeller including suitable common base frame, coupling, coupling guard, foundation and mounting bolt and nuts, M.S Flanges for both end, etc. as required complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender