Tender For Bid Document Of Aumentation Of Water Supply Scheme Dhandoi Block Qadian Distt. Gurdaspur (Under 15Th Finance Commission)
Tender Value
7.35 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
3 days left
EMD
14710
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurdaspur → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Bid Document Of Aumentation Of Water Supply Scheme Dhandoi Block Qadian Distt. Gurdaspur (Under 15Th Finance Commission)
BOQ
| Sl. No. | Item Description |
| 1 | Repair of 15 BHP Submersible Pump Set Complete in all respect of |
| 2 | Providing fixing of New Control Panel Board/Start Delta Oil Starter,Kit Kat,Shunt Capactor,Single Phase Preventor Complete in all respect. (15 BHP Motor) |
| 3 | Providing fixing of C.I delivery Pipe of size 80 mm i/d double flanged at both ends including jains and nut bolts complete in all respects |
| 4 | Supplying and laying C.I. specials as perIS:538completeasdesiredbyEngineer-in Charge conforming to ISI specifications.Note: If C.I specials of ISI Marked is used intead of specials confirming to ISI Specifications C.I. specials upto 300mm i/d(C.I. A/F Tee Air valve duly I.S.I. marked)1 x wt. @ 23 kg./each(Tee) |
| 5 | C.I. Blank Flange suitable for 80 mm i/d pipe duly I.S.I. marked |
| 6 | Providing, laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal Hisar) including cost ofspecials (such as tees, bends, sockets, elbows etc.) painting with anti corrosive bitumastic paint, testing, cutting, threading inside building complete.40mm i/d |
| 7 | Providing, fixing and jointing ISI Marked GunMetal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.40mm i/d Gun Metal peet valve heavy pattern. |
| 8 | Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete.C.I Double air valve (Size 40mm) |
| 9 | Cutting holes upto 23 cms quare through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. (b) Through wall 22.86 cm thick |
| 10 | Providing and fixing M.S Bore Pit Haudi Cover of size 0.90 mtr dia |
| 11 | Wiring in PVC insulated copper conductor single core FRLS cable (ISI marked), 1100volts grade to be laid in heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for having electronic fan regulators (socket size), bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20 Amp. Sockets and 6 Amp./16/20Amp. Swithces (flush piano type accessories) etc.and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (For Fan Box andElectronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:-Wiring fan point without fan box in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts (socket size). |
| 12 | Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. |
| 13 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket and switch including bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade complete. |
| 14 | Wiring 3 pin 16/20 amp. power plug control and switch. |
| 15 | Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent |
| 16 | Providing and fixing of electric tube set of reputed make |
| 17 | Dismantling brick or flagged stone flooring including concrete base. (Terrace Tiles) |
| 18 | Terracing consisting of tiles 22.86cm×11.43cum×3.83cm laid over25mm mud plaster, 7.50 cm mud filling on an other layer of 25mm mud plaster including two coats of bitumen laid hot @ 1.65Kg. Per Sqm on top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. |
| 19 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified |
| 20 | Scraping of Cement plaster |
| 21 | 12.5mm thick cement plaster 1:4 |
| 22 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed |
| 23 | Finishing walls with cement based water Soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade |
| 24 | Providing and fixing 14 gauge MS sheet garage doors with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15mm gusset plates including locking arrangement with handles etc. complete in respect(Door Size 1.4x2.5 m) |
| 25 | Applyingpriming coat withmetal primer on new steel on ironworkincluding preparation of surface. |
| 26 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 27 | Repair of 100 mm i/d Expansion joint Complete in all respect |
| 28 | Repair of 150 mm i/d Expansion joint Complete in all respect |
| 29 | Repair of 100 mm i/d Sluice Valve Complete in all respect |
| 30 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge). 150mm i/d Sluice Valves flanged |
| 31 | Scrapping White wash and colour wash |
| 32 | Water proofing of wet areas (Concrete/Masonary Surface) and any water retaining structures such as swimming pools, water tanks, Bathrooms,toilets, balconies, planters etc with high performance polymer modified cementitionous coating (DR.FIXITFASTFLEX/Equivalent ) to provide tough film build-up and high lye lastic film formation, which accommodates thermal movements soas to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning,washing and removing dust,dirt and loose particles from concrete/masonarysurface complete in all respects. for (OHSR) |
| 33 | Providing,Laying, fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISImarked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete asper specifications. manually 160mm o/d pipe of 10 Kgf. / sqcm |
| 34 | Household water connection ISI MarkedWater Connection Providing proposed water connection to house hold upto wall with providing laying jointing testing GI pipes lines 15mm i/d = 2.50mtr B Class as per CSR 28.36 (A) above GL Providing and fixing MDPE pipe 15mm i/d with specials 2.00 mtr (Below GL) including cost of specials such as tees bends sockets elbow etc cutting threading and testing in trenches in the ground and ISI 15mm i/d GM ferrule as per IS 2692 and 3\\" i/d clamp with CI bib cock 15mm i/d as per IS 210 with stainless steel spindle of approved make as per CSR 30.65 (b) Water Connections on Existing Pipeline and new pipe line |
| 35 | Repair of pipeline including cost of material, C.I D joint, nut bolts, dismantling and relaying of , bailing out water from trenches, backfilling after repair in original conditions AC pipe 6” i/d on( Bitumanuos Road) |
| 36 | PVC pipe 90 mm o/d on (Interlock Tiles +brick Paving) |
| 37 | Providing,Laying, fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISImarked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete asper specifications. manually (6kgf/ sqm) uPVC Pipe 63 mm o/d |
| 38 | uPVC Pipe 90 mm o/d |
| 39 | Dismantling and restoration brick paving complete in all respect as per DWSS standard approved analysis. PVC Pipe 63mm o/d |
| 40 | Hand boring Horizontly for crossing of pipe under road or any other obstacle byusing Auger/Bocki method.Including excavation ,stringing and jointing of pipe upto 160mm complete |
| 41 | Dismantling and restoration of Interlocking Road complete in all respect as per DWSS standard approved analysis. 63/90/110mm o/d |
| 42 | Providing & fixing 1.2mtr high fencing around the head works site with 1.65 meter post, placed every 2.5 meters apart, embedded in cement concrete blocks and every tenth post to be strutted with three rows of G.I. Barbed wire weighing 9.34 Kg per 100 meters (minimum) and fixing with GI staples tied to 6mm bar nib, with binding wire or by providing cut, including drilling holes in the post, including cost of posts, winding wire, strutted earth work in the post & aluminum painting complete in all respects as per DWSS standard Drawing and analysis. |
| 43 | Providing and Fixing angle iron pickets with angle 40 mm x 40 mm x 6 mm including cost of concrete block & Painting complete in all respect as per DWSS Standards Drawing & Analysis. |
| 44 | Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm as per DWSS standard Drawing and analysis. |
| 45 | Providing and fixing OHSR Jali |
| 46 | Providing and fixing OHSR Mainhole cover |
| 47 | Making Connecetion of Existing Ac Pipeline With Pvc Pipeline including Pvc / CI D joint and other specials required to fix Complete in all Repect. As per CSR Specifications Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓