Tender For Infrastructure Development Work Of Collectorate Building With Electrification Work Distt-Shahdol (M.P.)
Tender Value
3.12 Crore
Estimated cost
Bid Submission
06 Nov 2026
14 days left
EMD
3.12 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Shahdol → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Infrastructure Development Work Of Collectorate Building With Electrification Work Distt-Shahdol (M.P.)
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. |
| 2 | Removal of old Tarfelt i/c disposal as directed by Engineer in charge. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge.15.6.3-In cement mortar. |
| 4 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 5 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in- Charge.15.2.2 - Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). |
| 6 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade.M-20 Grade Concrete |
| 7 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in :6.7.2- Having 75 kg / cm2 average compressive strength.6.7.2.2- Cement mortar 1:6 (1 cement : 6 sand) |
| 8 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .5.16.3 Cold twisted bars (CTD) |
| 9 | 20 mm cement plaster of mix1:6 (1 cement : 6 sand) |
| 10 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead:15.15.1- Of area 3 sq. metres and below. |
| 11 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :21.1.1- For fixed portion.21.1.1.1- Anodised aluminium (anodisedtransparent or dyed to required shade according to IS: 1868, Minimum anodic coating of gradeAC15) |
| 12 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) :With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) |
| 13 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 14 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in :6.7 Having 50 kg / cm2 average compressive strength.6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) |
| 15 | Supplying and filling in plinth withcrusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing completeNote: - Maximum thickness of this layer shall be 20 cm. |
| 16 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :\a) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including roundingoff junction of vertical and horizontal surface.b) IInd course of 20mm cement plaster 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.c) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area.d) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) (with 5 years service guarantee) |
| 17 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete.Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of Chief Engineer will be required. |
| 18 | Wall painting by any mechanical or manual means with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade. |
| 19 | Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface) |
| 20 | Granite work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately).11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter |
| 21 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish wherever required etc. complete at all levels. Samples approved by Engineer-in- Charge.11.22.2-Granite fine grained dark crystal of other colours and various patterns |
| 22 | Providing and fixing stone slab table rubbed on both faces edges rounded and polished of size as required and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. |
| 23 | Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted single lever concealed basin mixture, (cartridge size 32 mm) 32 mm C. P. brass waste coupling length 130mm and 32 mm C. P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range)25.9.2-White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) |
| 24 | Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed S.S. screws having minimum density of 750 kg/m3 and screw withdrawal strength of 2200 N (Face) & 900 N (Edge), minimum compressive strength 58 N/mm2, modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately)9.167.2 Single rebate (100 mm X50 mm) |
| 25 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)9.170.2- 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter |
| 26 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodiccoating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete9.109.2- 250x16 mm |
| 27 | Providing and fixing aluminium handles ISI marked anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:9.113.1- 125 mm |
| 28 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.9.114.1-Single rubber stopper |
| 29 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coatingnot less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete9.110.6- 100x10 mm |
| 30 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm. |
| 31 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :17.1.2- Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests. |
| 32 | Providing and fixing white vitreous china Anti germ fluoro-polymer coated single piece W.C. dual flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete.Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) |
| 33 | Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) with sensotronic concealed type flushing valve battery & electrical oprated type (9V transformer) for urinal complete set with installation box with control cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required .25.12.2- White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) |
| 34 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, whiteP.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete including painting of fittings and cutting and making good the walls and floors etc. wherever required17.8.1- Single squatting plate with 5 litreP.V.C. automatic flushing cistern. |
| 35 | Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating. 10 micron and chrome plating 0.3 micron, quarter turn) Angular stop cock. (Premium Range) |
| 36 | Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Wall Mixer with 115mm bend. (Premium Range) |
| 37 | Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn)Bib cock. (Premium Range) |
| 38 | Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Pillar cock. (Premium Range) |
| 39 | Providing and fixing C.P. brassgrating of approved quality and make conforming to IS: specification11.78.1-100 mm dia. |
| 40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability forhot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge.18.7.4-32 mm nominal outer dia .Pipes. |
| 41 | Providing and fixing in position best Indian Stainless steel made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 600 mm long. (Premium Range) |
| 42 | Providing and fixing Automatic Soap Dispensers, Capacity : 0.8L, Material: Aluminium /ABS, Finish : Chrome/Black (Premium Range) |
| 43 | Providing and fixing in position best Indian single Lever Auto Mixing Diverter (Cartridge Size 47mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range) |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability forhot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge.18.7.3- 25 mm nominal outer dia .Pipes. |
| 45 | 18.7.6-50 mm nominal outer dia .Pipes. |
| 46 | Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ringconforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm)17.58.2- 110 mm diameter |
| 47 | 75 mm diameter |
| 48 | Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality / premium in skirting, riser, dado and wall lining laid our 12mm thick cement mortar 113 including grouting the joints with white cement and matching pigments etc. complete11.83.1-For skirting, riser, dado and wall lining etc. glossy/ rustic /stain/matt finished in all colours and shades11.83.1.5-Size 800X1200 mm thickness 11-12mm |
| 49 | Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium qualityincluding grouting the joints with white cement and matching pigments etc. complete11.82.1.6-Size 800X1200 mm thickness 9-10 mm |
| 50 | Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours & shades, 1st quality/ premium quality in skirting, riser, dado and wall lining laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. completeIn light colour and shades as ivory, beige blanco, grey etc.11.78.1.1-(b) Size 600X600mm thickness 9-10mm |
| 51 | Providing and fixing of unplasticised rigid PVC rain water harvesting filter kit UV protected with filter, PVC valve, conforming to IS: 1392, working pressure 4 kg\sqcmTypeB, minimum capacity 20 kilolitre/ hour, of approved make including all accessories like unplasicied PVC pipe cliips of approved design with bombay nail of required length including making good the wall etc.complete for designed catchent16.19.3-110 mm diameter PVC pipe, having wall thickness 3.2 mm for 250 m2 catchment area |
| 52 | Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.12.32.2-110 mm diameter (minimum wall thickness 2.2mm) |
| 53 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.12.33.5 Bend 87.5°11.33.5.2- 110 mm bend (minimum wallthickness 2.2mm) |
| 54 | Providing and fixing soil, waste and vent pipes:Hubless Centrifugally cast (spun) iron pipe epoxy coated in side & out side including complete coupling assembly (EPDM rubber gasket stainless steel claim and external metallic/ protective shield as per IS:15905) |
| 55 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigidP.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as perspecification for :-3.1.1- Light point/fan points.3.1.1.1- Primary short point |
| 56 | Primary medium point |
| 57 | Primary long point |
| 58 | 3 Pin 6 Amp socket outlet on separate board3.1.3.1- Short point |
| 59 | Medium point |
| 60 | Long point |
| 61 | Call bell/buzzer points3.1.4.2- Medium point |
| 62 | Long point |
| 63 | Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materialsas per specification on same board. |
| 64 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) of ISI marked suitable size etc. as required as per specification3.3.1- 2x2.5 Sq.mm. |
| 65 | 4x2.5 Sq.mm. |
| 66 | 6x2.5 Sq.mm. |
| 67 | 8x2.5 Sq.mm. |
| 68 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigidP.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :-5.1.1- Light point/fan points.5.1.1.1- Primary short point |
| 69 | Primary medium point |
| 70 | Primary long point |
| 71 | 3 Pin 6 Amp socket outlet on separate board5.1.3.1- Short point |
| 72 | Medium point |
| 73 | Long point |
| 74 | Call bell/buzzer points5.1.4.2- Medium point |
| 75 | Long point |
| 76 | Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigidP.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. |
| 77 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification5.3.1- 2x2.5 Sq.mm. |
| 78 | 4x2.5 Sq.mm. |
| 79 | 6x2.5 Sq.mm. |
| 80 | 8x2.5 Sq.mm. |
| 81 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-8.1.1- On separate board8.1.1.2- Medium point |
| 82 | Long point |
| 83 | Extra long -I |
| 84 | Extra long -II |
| 85 | Extra long -III |
| 86 | Supplying and fixing PVC conduit as required confirming to IS 9537 (Part-3), ISI marked along with accessories on surface etc. as required.15.1.2- PVC conduit 25 mm. (MMS) |
| 87 | Supplying and fixing factory fabricated hot dip galvanized switch box for normal flush type accessories of minimum 1.2 mm thickness for up to 200mmx250mm size boxes and 1.6mm minimum thickness for higher size boxes, earth terminal stud with nut and washer, including 3 mm thick synthetic phenolic resin bonded laminated sheet conforming to grade P-I of IS:2036-1974 on surface/concealed including all necessary accessories, painting etc. as required as per specification:18.1.1- MS box 100 mm X 100 mm X 60mm |
| 88 | MS box 200 mm X 150 mm X 60 mm |
| 89 | MS box 180 mm X 100 mm X 60 mm |
| 90 | MS box 200 mm X 250 mm X 60 mm |
| 91 | MS box 250 mm X 300 mm X 60 mm |
| 92 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc.as required for:-18.3.1- 1 Or 2 Module PVC box |
| 93 | 3 Module PVC box |
| 94 | 6 Module PVC box |
| 95 | 8/9 Module PVC box |
| 96 | 12 Module PVC box |
| 97 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.19.1.1- 1.5 sq. mm. wire19.1.1.1- 1 X 1.5 sq. mm. |
| 98 | 3 X 1.5 sq. mm. |
| 99 | 2.5 sq. mm. wire19.1.2.1- 1 X 2.5 sq. mm. |
| 100 | 4.00 sq. mm. wire19.1.3.3- 3 X 4.00 sq. mm. |
| 101 | 6.00 sq. mm. wire19.1.4.1- 1 X 6.00 sq. mm. |
| 102 | 3 X 6.00 sq. mm. |
| 103 | Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid steel ISI marked conduit of suitable size (Conduit included) including accessories long neck threaded type, connection painting etc, as required as per specification. (Refer General Notes for Classification ofConduit Wiring Point No.10)21.1.4- 4 Wire sub main21.1.4.3- 6.0 sq. mm. cable |
| 104 | Rewiring in existing surface/concealed rigid steel/PVC nonmetallic conduit with PVC insulated cable with copper multi strand conductor FRLS of ISI marked and other materials as required including replacement of wornout/damaged/missing material, painting etc. complete as per specification. This shall include all work, arrangement required for wiring but shall exclude switch, ceiling rose, fitting etc.24.1.1- Light/fan/3 Pin 6 Amp socket outlet on separate board/call bell/buzzer points :-24.1.1.1- Short point |
| 105 | Medium point |
| 106 | Long point |
| 107 | Circuit wiring24.1.3.2- 2 X 2.5 sq. mm. |
| 108 | 3 Pin 6 Amp socket outlet point on same board |
| 109 | 3 Wire sub main24.4.3- 3 X 6.00 sq. mm. |
| 110 | 4 Wire sub main24.6.3- 4 X 6.0 sq. mm. |
| 111 | Supply of I.S.I. Marked iron clad / metal clad triple pole and neutral switch fuse (conduit entry ) /cable gland entry with two earthing terminals --25.2.5- 200 Amps. 415/500 Volts. |
| 112 | Supplying of ISI Marked Change over switches in sheet enclosure confirming to IS : 4064 / IS : 13947 (part I & III ) with side handle operated 4 pole with two earthing terminals25.4.5- 200 Amps. 415/500 Volts. (off load ) |
| 113 | Supply & fixing of I.S.I.marked Porecelain Rewireable fuse unit of approved make or confirming to I.S.S. 2086-198225.16.4- 63 Amps /415 Volts |
| 114 | 100 Amps /415 Volts |
| 115 | 200 Amps /415 Volts |
| 116 | Supplying of metal clad ISI marked busbar chamber made of heavy gauge iron sheet complete with copper strip and busbar supports as per specification conforming to IS -406426.1.4- 200 Amp 415 VOLTS, 4 way |
| 117 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC: 60898 :2002 & 60947-2 but without enclosures :-27.8.1- Single pole27.8.1.2- MCB SP 6Amp to 32Amp 10kA rating |
| 118 | Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with kA value rating 10 kA of approved make conforming to IS:13947-Part III :1993 & IEC:60947- 3:2001 (without enclosures ) :-27.10.2 Double pole27.10.2.2- Current rating upto 63Amp |
| 119 | Four pole27.10.4.2- Current rating upto 63Amp |
| 120 | Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)-27.11.6- 12 Way double door IP 43 protection |
| 121 | Supplying of approved make TPN MCB DB metal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator):27.12.1- 4 Way (4+12) |
| 122 | Fixing of metal clad enclosure on 25X 25 X 5 mm angle iron clamp including supplying and fixing of clamp as required duly embedded in masonry including cable connection and other required material as per specification :-28.2.3-Fixing of 200 Amp TP or TPN main switch or 200 Amp change over switch/200 Amp 415 Volt Isolators and busbar 4 way |
| 123 | Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only)28.4.1- MCB/Isolator SP/DP |
| 124 | MCB/MCCB Isolator TP/TPN/FP |
| 125 | Labour charges for fixing sheet steel enclosures, MCB/MCCBDB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete :-For item no :-28.8.1- 27.11.1 to 27.11.7 ; 27.12.1 to 27.12.3 & 27.13.1 |
| 126 | Supply and fixing as per specification call bell/buzzer of approved make with necessary materials complete.29.3.2- Buzzer |
| 127 | Ding dong bell |
| 128 | Multi sound bell |
| 129 | Remote/cordless bell |
| 130 | AUDIO CABLESSupply and fixing of PVC insulated copper flexible speaker wire twin FRLS 1100 Volts as per IS:694-1990 of approved make29.5.1.3- (48/0.20 mm) Twin core 1.50 sq.mm. |
| 131 | Supply and fixing of multi core round FRLSH PVC insulated copper (flexible) conductor & PVC sheathed cables 1100Volts as per IS:694-1990 of approved make29.6.3- (30/0.25 mm) Three core 1.5 sq.mm. |
| 132 | Supply and fixing of MPP condenser 440 Volt single phase of approved make as required as per specification29.16.1- Condenser 2.5 mfd 440Volt |
| 133 | Supply and fixing of approved make flush type step type electronic fan regulator including connection etc. as required on existing board29.23.1- 100 Watt |
| 134 | Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board29.25.2- 100 Watt(2 module) |
| 135 | Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments.30.1.2- Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE.. |
| 136 | Supplying, erection and testing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and including raw bolt/anchor hole fastener etc. complete finished and as required.30.2.2-400 mm sweep |
| 137 | Supplying, erection and testing of approved make 'Fresh air fan' AC 230-250 volts with connection and including frame bolt/anchor hole fasteners etc. complete finished and as required.30.4.5.- 300 mm sweep double ball bearing |
| 138 | Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self-closing louvers of decorative PVC blades mounting square frame of approved make complete with all necessary material as required30.5.4- 300mm RPM1300/1400 |
| 139 | Supplying and replacement of cooler fan 500 mm (20\\") ISI marked with all necessary material including connection complete of approved as required |
| 140 | Supply and replacement of ISI marked cooler submersible water pump complete with all necessary material including connection of approved make as required |
| 141 | Supply and fixing Led tube rod comprising of LED tube with non- integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598,IEC61347i/c connection wire, testing etc. to complete the job.31.3.3- Tube light LED 1 X 18Watt, Integral i/c batten aluminium body, PC diffuser. |
| 142 | Supply and fixing of recessed mounting type Led light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF> 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.31.4.2- LED luminiare 2' X 2', 42/45Watt, color temp 3000-6500k as required. |
| 143 | Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job..31.6.4- 12 Watt, color temp 3000-6500k as required. |
| 144 | Supply and fixing surface mounting LED down lighter, LED of 1 to 3Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job..31.7.4- 14/15 Watt, color temp 3000-6500k as required. |
| 145 | Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF>0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job.31.13.2- 60Watt, color temp 3000-6500k as required. |
| 146 | Supply, Installation, Testing and Commissioning of Electrical Napkin Incinerator Wall mounted factory fabricated with CRCA sheet steel of 1.2mm thickness duly powder coated suitable for 230V 50Hz AC Supply with auto cut-off feature having insulation of thermal ceramic sheet with glass wool of 4-5mm thick with MCB protection & aprox.2 meter flexible flue gas pipe with clamp.32.17.2- Sanitary Napkin Incinerator( Capacity 50 per Day) |
| 147 | Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required |
| 148 | Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required |
| 149 | Add extra for using salt and charcoal/coke forG.I. plate or copper plate earth electrode as required including excavation and refilling the pit in all type of soil, murrum |
| 150 | Supply and laying 4.0mm (8 SWG) dia. G.I. wire at 0.5 metre below ground level as conductor earth electrode including jointing etc. as required. |
| 151 | Supply and laying 4mm dia. copper wire at0.5 metre below ground level as conductor earth electrode including soldering etc. as required. |
| 152 | Supplying &installation of required capacity of single phase, 50 Hz, 220V, deep well submersible pump stainless steel body, as per IS of approved make, suitable for 4\\"/6 \\" tube well with control panel starter suitable for submersible pump with dry run protection, connections, including clamp, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope and connection cable.39.01.07- 1.5 HP with 10-11 stages, head metre 84-26, dischargeLPM 25-90 |
| 153 | 2 HP with 20-22 stages, head metre 147-42, dischargeLPM 15-55 |
| 154 | Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make.29.3.3- 6.0 sq.mm multi strand |
| 155 | Supplying and laying of approved make nylon rope 12 mm thick complete with binding for support of pump and motor. |
| 156 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor41.1.10- 4 core armoured41.1.10.3- 16 sq. mm. |
| 157 | 25 sq. mm |
| 158 | Laying of underground cable armoured./unarmoured as per specification in air suspended on existing approved type of iron clamp, G.I wire 7/1.6mm & shackle insulator/insulated strip complete.41.20.1- 1/2/3/4 Core cable upto 16 sq. mm |
| 159 | 1/2/3/3½/4 Core cable 25 sq. mm to 120 sq. mm |
| 160 | Supply, installation, testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required.46.3.1- Copper tube 1/4\\" |
| 161 | Copper tube 3/8\\" |
| 162 | Chemical servicing of window/split air conditioning unit 1TR/1.5TR/2TR/3TR capacity including cleaning of cooling & condensing units, filters, grills etc & all other parts oiling & greasing of fan motor, testing of A.C unit etc. |
| 163 | Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any.46.5.2- 1.5 TR |
| 164 | 2.0 TR |
| 165 | Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, minimum load power factor 0.8,power factor 0.99, having OVCD (over voltage cut-off device), having CVCF (constant voltage constant frequency, bypass parameters configurable, 2 stage charging(constant current/float charge), having temperature compensated charger, Fan speed control, digital signal processor controller, total harmonic distortion (current)-THDi (<10%@50% R Load, Input 1 phase voltage 230v, voltage range 110-300v, Output voltage (220AC/230AC/240AC ± 1%), Total harmonic distortion Voltage (THDv- <3% linear load, <5% nonlinear load, 90 % AC/AC efficiency, Over load capacity(105-110%: 3min, 111-130%: 30Sec), operating temperature with full load 0-40°C, communication features (RS232, USB com port, Intelligent slot(optional). UPS installation with all required material arrangements as47.1.1- 1 KVA (1 phase input & 1 phase output)47.1.1.3-For 120 minute backup, min. 3200 VAH |
| 166 | Supply, installation, testing and commissioning of 12/24 V Battery system in series/parallel combinations or as single as per requirement including interconnetion wiring, lugs and other required material as required with maunting stand/trolley, warranty period: Minimum 3 year47.5.2- 150/160 AH, Tall Tubular |
| 167 | Supplying and fixing of hot water storage water heatervertical with required safety, ABS body including connection pipe, foundation bolt and nut, connection pipe, stop cock, testing etc. to complete the job.57.9.1- 15 Ltr. (5 Star rating- standing losses ≤0.419 kWh/24 hrs/45°C) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender