Tender For 8588/E8 special Repair To Toilets , Roof Treatment And Allied Wks To Otm Accn Bldg No T-150 & T-151 (Office Complex) Of 116 Engr Regt Under Ge (East) Bareilly
Tender Value
43.19 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
17 days left
EMD
86400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bareilly → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for 8588/E8 special Repair To Toilets , Roof Treatment And Allied Wks To Otm Accn Bldg No T-150 & T-151 (Office Complex) Of 116 Engr Regt Under Ge (East) Bareilly
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster including racking out joints, hacking for key&scrubbing down with water etc complete all as specified and directed |
| 2 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 3 | Dismantling of stone slabs and tiles of any description or thickness in floors ,aprons laid,bedded and jointed in any mortar etc all as specified and directed. |
| 4 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above ground level complete all as specified and directed by Engineer-in-Charge. |
| 5 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 6 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge. |
| 7 | Excavating in trenches n. exc. 1.5 m wide, and n.exc. 1.5 m in depth for foundation etc. n.exc. 10 sqm on plan and n. exc. 1.5 mtr in depth and getting out hard/ dense soil complete all as specified and directed |
| 8 | Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engineer-in-Charge. |
| 9 | Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engineer-in-Charge. |
| 10 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixingor removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed |
| 11 | Taking up or down15 mm steel tubing and connections including cleaning for refixing or removal complete all as specified and directed by Engr-in-Charge |
| 12 | Taking up or down20 mm steel tubing and connections including cleaning for refixing or removal complete all as specified and directed by Engr-in-Charge |
| 13 | M & L for dismantling water tanks exc 500 but not exc 1000 Litres, and removing to store complete all as specified and as directed. |
| 14 | M & L 25 mm thick PCC 1:2:4 type B-1, using 25 mm graded stone aggregate as in floors to receive surface of tiles complete all as specified and directed. |
| 15 | M&L screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed. |
| 16 | M&L Non- skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile incl screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes complete complete all as specified and directed. |
| 17 | M & L 9 to 10 mm thick glazed coloured ceramic tiles ( square/ rectangular) with border , area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles incl 15mm thick rendering in cement mortar 1:4 to brick masonry wall surfaces for fixing tiles. complete all as specified and directed. |
| 18 | M&L for vitrified tiles 7 to 8 mm thick (square / rectangular )area of each tiles exc 0.18 sqm but not exceeding 0.38 Sqm in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles incl screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes completecomplete all as specified and directed |
| 19 | M&L for non skid ceramic tiles 7 to 8 mm thick (square / rectangular )area of each tiles exc 0.18 sqm but not exceeding 0.38 Sqm on vertical surfaces etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles incl 15mm thick rendering in cement mortar 1:4 to brick masonry wall surfaces for fixing tiles. complete all as specified and directed. |
| 20 | M&L 18-20 mm thick Granite of black colour (table rubbed and polished) in win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with full round bull nosing edging complete all as spd as directed |
| 21 | M & L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed . |
| 22 | M&L for reinforced cement concrete 1:1.5:3 type A-1 (using 20 mm graded stone aggregate ) ( nominal mix ) as in slabs supported on wall ,landing, balconies ,shelves and like including demolition of existing slab ,complete all as spd (reinforcement to be measured &paid under respective items ) |
| 23 | M&L form work to chajja, slab ,weather shade, troughs and similar items including edges for rough finished surfaces of concrete flat, complete all as specified. |
| 24 | M&L form work to edges of concrete flats, treads, breaks in floors window cill, concrete railing opening in conc wall , floor and roof n.exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20cm wide for rough finished surfaces of concrete, complete all as specified. |
| 25 | Supply and fix TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all as specified. |
| 26 | S&F 32 mm dia GI pipe ,medium grade as in spout pipe in suken floor complete all as spd and directed. |
| 27 | M&L for brick work with fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as spd and directed |
| 28 | M&L rendering 15 mm thick in CM 1:6 on brick masonry surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed. |
| 29 | M&L 15mm thick rendering in cement mortar 1:4 to brick masonry wall surfaces or on other than fair faces of brick masonary finished even and smooth without using extra cement with using water proofing liquid @ 0.15 Ltr per bag of cement complete all as specified and directed. |
| 30 | M&L rendering 10 mm thick in CM 1:4 as on concerete surface on ceilings finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 31 | M&L for applying cement slurry over existing roof surface @ 3 kg/Sqm incl mix with water proofing liquid @0.15 Ltr per 50 kg cement bags as per manufactureres instructions complete all as spd and directed |
| 32 | M &L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregrate laid over roof slab after applying cement slurry for filling undulationations finished even and smooth without using extra cement complete all as spd and directed. |
| 33 | M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150 ml per bag of cement complete all as specified and directed by Engineer-in-Charge.(Note : Water proofing liquid shall be measured and paid separately) Please Enable Macros to View BoQ information |
| 34 | M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150 ml per bag of cement complete all as specified and directed by Engineer-in-Charge.(Note : Water proofing liquid shall be measured and paid separately) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysNov 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender