Road Transport and Highways Government Departments Closing in 0 days TDR #58121740

Tender For Special Repairs (Sr) Works For Improvement Of Cross Drainage System By Construction Of Reinforced Cement Concrete Box Culverts At Flood-Prone Locations On Nh-66 In The State Of Goa During Fy 2026-27.

Issued by Government Departments · goa, Goa
Tender Value
5.05 Crore
Estimated cost
Bid Submission
23 Nov 2026
0 days left
EMD
10.11 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs (Sr) Works For Improvement Of Cross Drainage System By Construction Of Reinforced Cement Concrete Box Culverts At Flood-Prone Locations On Nh-66 In The State Of Goa During Fy 2026-27.

BOQ

Name of Work:- Special Repairs (SR) works for Improvement of cross drainage system by construction of R.C.C. box culverts at flood-prone locations on NH-66 in the State of Goa during FY 2026-27.
Sl. No. Item Description
1Clearing and Grubbing Road Land .(Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.)i) By Manual Means:-A) In area of light jungle
2Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.)v) Marshy SoilA) Manual means (upto 3 m depth)
3Rubble packing with hard laterite stone under floors including watering, ramming & consolidating etc. complete
4Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications A) PCC Grade M15
5Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications.A) PCC Grade M25Case I) Using concrete Mixer
6Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in chargeA) 110 mm dia
7Supplying and laying Terra Geo-Composite Drain consisting of a HDPE/PP/PE geonet core sandwiched between non-woven needle-punched geotextile filter layers behind abutments/retaining walls. The composite drain shall have a minimum tensile strength of 20 kN/m(MD/CD per ASTM D4595), in-plane flow capacity of 1.5 l/m.s at 100 kPa (ASTM D4716), and CBR static puncture resistance of 3000N (ASTM D6241). The geotextile filter shall feature a perpendicular permeability of ≥70 l/sqm.s(ASTM D4491) and an Apparent Opening Size (AOS) of ≤150microns(ASTM D4751). All properties must represent Minimum Average Roll Values (MARV) verified through an NABL-accredited laboratory test report. Make or Supply by GEOQUEST India , SOLMAX as directed by the Engineer in charge.
8Providing and erecting a \\"Thrie\\" metal beam crash barrier comprising of following three factory made unites-viz. 1) Thrie Beam 2) Spacer Block 3) Vertical Post. The Thrie beam 3mm thick cold roll formed guard rail raw material Conforming to IS-5986-2011 with minimum Grade 255 & with minimum yield stress of 255 Mpa which is fixed by bolted connection to spacer block C-channel of size 75mmx150mm & 5mm thick, 54.6cm height spaced 2meter centre to centre, fixed to Vertical Post C-channel of size 75mmx150mm &5mm thick cold roll formed section made from HR coils raw material conforming to IS-5986-2011 with minimum Grade 255 & with minimum yield stress of 255MPa, with 85cms free height above road or Ground level, and embedded to 115cms deep in cement concrete block of size 35cm*35*115cm of minimum grade M15 (1:2:4) or as directed by Engineer Incharge, assembled & fixed as per drawings of MORTH&H Circular No.RW/NH/33022/1/94-DO/III, dated 24/6/1994 & construction operation as per 811 or relevant MORT&H specifications for Roads & Bridge Works (latest edition). All fittings (bolts,nuts,fasteners,washers etc.) shall be conforming to IS:1367 & IS:1364 & galvanished by hot dip zinc coated process @0.55kg/m2 conforming to relevent IS specifications all etc.complete
9Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and nserviceable materials separately)I) By Manual MeansA) Bituminous courses
10Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, ncluding T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres)i) Lime/Cement ConcreteI) By Manual MeansB) Cement Concrete Grade M-15 & M-20
11Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.)i) Ordinary SoilA) Manual Means (Depth upto 3 m)
12Rubble packing with hard laterite stone under floors including watering, ramming & consolidating etc. complete
13Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specificationsA) PCC Grade M15
14Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications
15Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications.D) PCC Grade M25Case I) Using Concrete Mixer
16Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge.A) 110 mm dia
17Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.
18Granular Sub-base with Close Graded Material (Table:- 400-1)Plant Mix Method (Construction of granular sub base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 ).
19Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density)
20Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means.)
21Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.)ii) for GradingII (19 mm nominal size)
22Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom
23Bituminous Concrete (Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired ompaction as per MORTH specification clause No. 507 complete in all respects).i) for Grading-I (13 mm nominal size)
24Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
25Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)
26Road Markers/Road Stud with Lense Reflector (Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973)
27Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409).A) Using Concrete Mixer
28Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M30 grade made by heavy duty block making machine with strong vibratory compaction using 3 ton roller and of aprpoved size and design / shape laid in 50 mm thick compacted bed of course sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.
29Providing and inserting nipples with approved fixing compound MC Fix ST of MC Bauchemie or Equivalent after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy
30Sealing of cracks/porous concrete by injection process through nipples/ Grouting With Admixture MC Ein preshilf EH of MC Bauchemie or Equivalent)complete as per Technical specification. A) Cement Grout
31B) Cement Mortar (1:1) Grouting
32Sealing of crack / porous concrete with Epoxy Grout (MC Dur 1264 of MC Bauchemie or Equivalent)by injection through nipples complete as per clause 2803.1.
33Removal of defective concrete, cleaning the surface thoroughly, applying the shotcrete mixture mechanically with compressed air under pressure, comprising of cement, sand, coarse aggregates, water and quick setting compound Centrament Rapid 640 of MC Bauchemie or Equivalent)in the proportion as per clause 2807.1., sand and coarse aggregates conforming to IS: 383 and table 1 of IS: 9012 respectively, water cement ratio ranging from 0.35 to 0.50, density of gunite not less than 2000 kg/cum, strength not less than 25 Mpa and workmanship conforming to clause 2807.6.
34Eproxy bonding of new concrete to old concrete
35Replacement of damaged concrete railing.
36Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications
37Patching of damaged concrete surface with polymer concrete (MC Dur 1250 & Accelerated compound Torkrethilfe BE of MC Bauchemie or Equivalent) and curing compounds Emcoril AC, initiator and promoter, available in present formulations, to be applied as per instructions of manufacturer and as approved by the Engineer. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58121740
AUTHORITY Government Departments
TENDER VALUE 5.05 Crore
LAST DATE 23-11-2026
Authority
Authority Name Ministry Of Road Transport And Highways
Work Description Tender for Special Repairs (Sr) Works For Improvement Of Cross Drainage System By Construction Of Reinforced Cement Concrete Box Culverts At Flood-Prone Locations On Nh-66 In The State Of Goa During Fy 2026-27.
Basic Detail
Tender No 13/1/2026-27/PWD/ WDXIV/NH/ASW/14 dt 19.10.2026
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 19 Oct 2026
Submission Date 23 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 5.05 Crore
Tender Fee 10000
EMD 10.11 Lakhs
Exemption Not Available
Document List
BOQ_976076.xls
f7aab34b-309e-4e81-9447-008ce5d934ed.html
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_976076.xls

html

f7aab34b-309e-4e81-9447-008ce5d934ed.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender