Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #58119655

Tender For Repair / Replacement Of Internal Water Pipe Lines / Ci Pipe And Water Tank At Other Connected Misc Work At Darjipura At Afs Baroda.

Issued by Statutory Bodies & Commissions/Committees · Vadodara, Gujarat
Tender Value
25 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
14 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair / Replacement Of Internal Water Pipe Lines / Ci Pipe And Water Tank At Other Connected Misc Work At Darjipura At Afs Baroda.

BOQ

Name of Work:- Repair / replacement of Internal Water pipe lines / CI Pipe and water tank at other connected misc work at Darjipura at AFS Baroda.
Sl. No. Item Description
1Taking up or down steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
2S&F medium grade galvanized tube with all fitting all fixed to wall and ceiling or laid in floor, complete all as specified and directed.
3Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)complete all as specified and directed.
4S&F in repair Low density polythylene (LDPE) pipes of pressure rating 6kgf/sq.cm (15 mm bore) complete all as specified and directed.
5Cutting chases, pinning in, Brick Walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, complete all as specified and directed.
6Dismantling of water tank and removal to store yard exc 500 and n.exc 1000 lt. complete all as specified and directed.
7S&F 1000 ltr rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted, complete all as specified and directed.
8Dismantling of water tanks exc 2000 and n. exc. 5000 ltr and removing to store, complete all as specified and directed.
9S&F 5000 ltr rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted, complete all as specified and directed.
10Dismantling of water tanks exc 5000 and n. exc. 10000 ltr and removing to store, complete all as specified and directed.
11S&F 10000 ltr rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted, complete all as specified and directed.
12Dismantling of water tanks exc 250 and n. exc. 500 ltr and removing to store, complete all as specified and directed.
13S&F 500 ltr rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted, complete all as specified and directed.
14S&F in repairs stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of size, complete all as specified and directed.
15S&F angle valves, cast copper alloy, Fancy ype,Chromium Plated 15 mm dia screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
16S&F cromimum plated with long shank (concealed type) stop valves cast copper alloy screwed down high pressure a handle screwed both and for iron pipe 15mm bore, minimum furnished weight not less than as per SSR Pt I, complete all as specified and directed.
17S&F 15mm bore brass bib cock CP cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule. minimum furnished weight not less than as per SSR Pt I, complete all as specified and directed.
18ditto as per item above but fancy type
19S&F in repairs pillar taps cast copper alloy with capston head CP screwed down high pressure with or without lettered “hot or cold” with long screwed shank and fly nuts for iron pipes 15 mm bore, complete all as specified and directed.
20ditto as item no 21 but fancy type, complete all as specified and directed.
21S&F Brass CP mixer 15mm bore, for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed.
22S&F in repairs, Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as directed by Engr-in-Charge.
23M&L cleaning of existing tanks of any description provided on roof including removing all scale and dirt etc. from tanks and from mouth of circulations pipes and washed with beaching powder all as directed by Engineer-in-Charge capacity exc 250 ltr and not exc. 500 ltrs omplete all as directed by Engr-in-Charge.Note :- Date of cleaning shall be marked on tank with synthetic enamel paint.
24M&L cleaning of existing tanks of any description provided on roof including removing all scale and dirt etc. from tanks and from mouth of circulations pipes and washed with beaching powder all as directed by Engineer-in-Charge capacity exc 500ltr and not exc. 1000 ltrs omplete all as directed by Engr-in-Charge.Note :- Date of cleaning shall be marked on tank with synthetic enamel paint.
25S&F in repairs Gun-metal, globe or gate valves of 20mm with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
26S&F Gun-metal, globe or gate valves of 25mm, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
27Dismatling floor, hearth or wall tiling including cement mortar bedding backing removing serviceable tiles and rubbish of the premises, complete all as specified and directed.
28M&L non skid ceramic coloured tiles area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm thick in floor etc 15mm thick screed bedding in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed.
29M&L non skid ceramic coloured tiles area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm thick in floor etc 15mm thick screed bedding in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed.
30M&L glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm / 300 x 200 x 7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match tile in dado,including 10 mm thick rendering in CM 1:4 even and fair to receive tiles etc, complete all as specified and directed.
31S&F PVC valveless, syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle incl brackets, 10 ltr capacity, fixed in repair.
32S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) fixed on floor /Nahani trap in repair all as specified and directed by Engr-in-Charge.
33S&F 150x150mm salt glazed stone ware gully trap ’P’ type grating fixed in repair in PCC 1:2:4 type B1 30x30x30cm with steel grating, complete all as specified and directed.
34S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white (european type) (excluding fixing bolt flushing cistern and flush pipe, complete all as specified and directed.
35S&F in repairs water closet vitreous china squatting pan ‘Orissa’ pattern of size 580x440mm white with integral foot rest front/back inlet (excluding flushing cistern and flush pipe) anti symphonize pipe etc and provision of cement concrete bedding in PCC 1:5:10 type B2 and making good the disturbed floor surfaces, complete all as specified and directed.
36S&F vitreous china semi-pedestal pattern white (anglo-indian type) white (excluding fixing both flushing cistern and flush pipe) complete all as specified and directed.
37S&F Plastic Water Closet seat, black,closed pattern with flat bottom and covered and mild steel chromium plated or aluminised hinging device, complete all as specified and directed.
38S&F in repair Vitreous China urinals, bowl type (back or corner wall type), omplete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing utomatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, complete all as specified and directed. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
39S&F in repairs wash hand basin vitreous china white flat back size 550x400 mm fixed on existing bracket incl. one No. CP brass fitting & PVC connection 15 mm bore 45 cm long heavy duty and connecting to existing GI pipe or stop valve, complete all as specified and directed.
40S&F PVC connection 15mm size with PTMT nuts of length 450mm long, complete all as specified and directed.
41S&F flush pipe of PVC 32mm dia for low level flushing cistern fixed in repair, complete all as specified and directed.
42S&F swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40 gms) complete all as specified and directed.
43M&L for special treatment to sunken portion (inc necessary dismantling of tiles and PCC along with req PCC at site of mix 1:2:4 of req thickness) with 10mm thick plaster in CM 1:4 with WPC Liq complast 421 and applying one coat each of Nitroproof 100 and Nitroproof 120 on plastered surface, Rendering again 10 thick plaster in CM 1:4 mixed with complas 421 in sunken portion of WC and CI pipe, joint shall be filled inc filling of lean conc 1:5:10 complete all as specifiesand directed.
44S&F in repairs Waste coupling of PTMT (half or full threaded) (Min wt 45 gms for 32mm) complete all as specified and directed.
45Waste coupling of PTMT (half or full threaded) (Min wt 60 gms for 40mm) complete all as specified and directed.
46S&F Ball valves in repair high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Min wt 142 gms) (bore dia 15mm) complete all as specified and directed.
47S&F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Min wt 210 gms) (bore dia 20mm) complete all as specified and directed.
48S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed.
49S&F in repairs brass chromium plated tubular towel rail, 20mm dia, 60 cm long between flanges complete all as specified and directed.
50Dismantling / taking up of CI/PVC or reinforced concrete drain pipes 75/100mm internal dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
51S&F CI soil waste vent and rain water pipe 75 mm bore (ISI Marked) in any length with or without ears with cement joint laid in floor/fixed to wall complete all as specified and directed. Make:- Nico or equivalent make approved by GE.
52S&F CI soil waste vent and rain water pipe 100 mm bore (ISI Marked) in any length with or without ears with cement joint laid in floor/fixed to wall complete all as specified and directed. Make:- Nico or equivalent make approved by GE.
53S&F in repair cast iron floor trap 75 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1, (1:2:4) complete all as specified and directed.
54S&F bends any radius diminishing piece or tapers of CI 100 mm dia complete all as specified and directed.
55S&F CI P or S trap 100 mm bore complete all as specified and directed.
56S&F 75mm bore CI branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
57S&F 100mm bore CI branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
58S&F 75mm bore CI bend (any radius) with duck foot or heel rest complete all as specified and directed.
59S&F 100mm bore CI bend (any radius) with duck foot or heel rest complete all as specified and directed.
60S&F CI cowl for 100mm bore pipes complete all as specified and directed.
61Cutting around pipe 100mm bore and open the lekage joint and repair with cement morter 1:1 with water proofing compound and making good the surface with CM 1:3 and touch with cement base paint(externally from first floor to third floor complete all as specified and directed.
62S&F in repair 40mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
63S&F in repair 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor, complete all as specified and directed.
64S&F in repair 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor, complete all as specified and directed.
65S&F 110 mm dia PVC (SWR) bends any length any type, complete all as specified and directed.
66S&F 75 mm dia PVC (SWR) bends any length any type, complete all as specified and directed.
67S&F 110mm PVC (SWR) branch piece double (double Y) equal or unequl, complete all as specified and directed.
68S&F 110mm PVC (SWR) branch piece double (Single Y) equal or unequl, complete all as specified and directed.
69S&F 75mm PVC (SWR) branch piece double (Single Y) equal or unequl, complete all as specified and directed.
70S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
71S&F stack clamp made of 50 mm X 5 mm flat iron and 16 mm dia round iron stay including nut bolts and securing ends of stay to wall or roof suitable for 100 mm bore pipe complete all as specified and directed.
72Rectification of No water supply caused due to air lock or blockage in internal or external water supply pipe line of any diameter by manual means or by using pressure pump, including tracing the cause, removing obstruction/air lock,flushing the pipeline and ensuring continuous and satisfactory flow of water up to the outlet,including taking down taps,pillar taps,angle/stop valves or simillar fittings for clearing blockages and refixing the same position complete all as specified and directed.
73S&F 8mm thick glass shelf size 450mmx100mm with SS brackets/rail as approved and directed by Engineer-in-Charge.
74S&F 8mm thick glass corner, radius not exceeding 300mm dia with SS brackets/rail as approved directed by Engineer-in-Charge.
75S&F in repairs brass chromium plated tubular towel rail, 20mm dia, 60 cm long between flanges complete all as specified and directed.
76S&F soap dish, any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed.
77S&F Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed.
78S&F PVC cover for water storage tank for 500ltr, complete all as specified and directed.
79S&F PVC cover for water storage tank for 1000 ltr, complete all as specified and directed.
80Rectification of leakage in concealed GI / PVC pipeline by carefully dismantling wall / floor tiles, chasing and explosing the concealed pipe, cutting out damaged / leaking portion and replacing the same with new GI/PVC pipe and fittings of required size including sockets, nipple, unions, elbows, tees etc as required. Testing the repaired pipe for leakage, refilling the chased portion with cement motar, making good the disturbed surface, refixing with new tiles with matching joints, including all necessary materials, tools for area n exc. 1.0 sqm, complete all as specified and directed.
81Repair to PVC door shutter and frame by dismantling the existing shutter, attending necessary repairs including tightening / repair / replacement of damaged hinges and fixed to frame and wall/tiles, complete all as specified and directed.
82Notes :(a) Notes for Bib tap / stop cock / pillar tap / CP /PVC Fittings / Cleaning of Water tanks: - Such type of complaints / repairs shall be resolved within 48 Hrs of intimation. If complaints not attended in stipulated period penalty at the double of the coated rate shall be imposed and no claim whatsoever on this account shall be entertained by the department, in case due to any technical reasons if it is not possible to resolve the issues within stipulated period, the contractor shall immediately inform the fact to Engr-in-Charge for further directions.
83Note for all items :- If any item gets repeated in this schedule, the lowest rate quoted for those same items by the L-1 bidder shall be considered for payment and decision of Accepting Officer i.e. GE(AF) Baroda in this regard shall be final and binding. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58119655
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 03-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacement Of Internal Water Pipe Lines / Ci Pipe And Water Tank At Other Connected Misc Work At Darjipura At Afs Baroda.
Basic Detail
Tender No 8208/E8
Bidding Type Tender
Location
City Vadodara
State Gujarat
Key Dates
Publish Date 19 Oct 2026
Submission Date 03 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Not Available
Document List
562f36ca-fa37-4d97-be2e-a52082b2ee5a.html
8208PS.pdf
BOQ_891385.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

562f36ca-fa37-4d97-be2e-a52082b2ee5a.html

pdf

8208PS.pdf

xls

BOQ_891385.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender