Tender For Repairs /Replacement And Day To Day Maintenance Of Lt Distribution System Cables, Lt Panel, Lt Poles And Connected Items At Airfield And Harni C At Afs Vadodara
Tender Value
28 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
20 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs /Replacement And Day To Day Maintenance Of Lt Distribution System Cables, Lt Panel, Lt Poles And Connected Items At Airfield And Harni C At Afs Vadodara
BOQ
| Sl. No. | Item Description |
| 1 | M&L for repair and rectification of external LT electric supply complaints on 1100 Volts grade, over head system along with necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- |
| 2 | S&F in repair worn out jumpers, jointing and tightening with ACSR conductor.Note:- Single phase / two wire or 3 phase / 4 wire system will be considered as one job for payment purpose. |
| 3 | Taking out existing cable of following sizes from Junction boxes / LT Panels and cut out the worn out / burnt portion of cable, extend the cable from loop, excavation and re-fixed the same after providing new lugs using crimping tools, providing heat shrinkable end termination joint of suitable size as required and as directed by Enr-in charge:- |
| 4 | 3.5 Core 16 Sqmm to 50 Sqmm |
| 5 | 3.5 Core 70 Sqmm to 240 Sqmm |
| 6 | Note :- (i) Aluminium lugs, LT end Jointing Kits, Cable protection Pipe, Excavation, Returning Filling, Removing, Sand and PCC coping of poles if required at site will be measured and paid separately under relevant items.(ii) Taking out old Bricks / cover will be re-used as cable protection. |
| 7 | Supply only Aluminium cable lugs ( lugs are made from 99.5% pure aluminium) as per IS of following Size;-Note:- Each core of cable will be measured as one unit for payment. |
| 8 | 240 Sq mm |
| 9 | 185 Sq mm |
| 10 | 120 Sq mm |
| 11 | 95 Sqmm |
| 12 | 70 sqmm |
| 13 | 50 sqmm |
| 14 | 35 sqmm |
| 15 | 25 Sq mm |
| 16 | 16 sqmm |
| 17 | 10 sqmm |
| 18 | M&L for straight through joint outdoor type for LT UG cable including jointing kits heat shrinkable type complete suitable for aluminium conductor cables complete all as specified and directed of the following size. |
| 19 | Size of 25 to 50 sqmm 3.5 core |
| 20 | Size of 70 to 120 sqmm 3.5 core |
| 21 | Size of 150 to 185 sqmm 3.5 core |
| 22 | Size of 240 to 300 sqmm 3.5 core |
| 23 | S&F in repairs Glow sign board of size 2 m x 1.5 m x 0.20 m made out of 1.0 mm thick plain GI sheet all side except front side, aluminium beading \\"L\\" shape at all boarder exterior and interior side, front should be Flex sheet 2.0 mm thick of blue colour and written the subject matter as given by the Engr-in-charge in English capital letter in white colour with twin LED tube light fitting 1 x 22 watt (2 Nos) including all electrical connection with surface conduit wiring 1.5 Sqmm ((length not exceeding 8 meter) copper wire with drilling and necessary required arrangement for fixing of board including testing as all specified and directed. |
| 24 | Deployment of manpower / tools and minor spare etc for Repair / maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 125 KVARs and up 8/10 stages installed at various locations at AFS Harni camp or airfield Baroda area including carrying out complete maintenance / repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs / MCCBs for isolation (with all the accessoires) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts / new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed. |
| 25 | Notes:-(i) Rate quoted by tenderer is deemed to be inclusive of checking of system, replacement of defective control wiring, small part such as Push button, lugs any auxilary contatct, auto selctor switch etc and necessary servicing repair by expert technician and register will be maintaned for the same. (iii) The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs / MCCB and fixing / installing / testing and commissioning the complete system. (iii) Measure components such as capacitors bank, APFC relay, power contactor, control CT, MCBs / MCCB shall be measured and paid saperatly. |
| 26 | Supply & fix in repairs power factor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete all as specified and directed. |
| 27 | Supply & fix in repairs power factor correction capacitor, 10 KVAR, heavy duty 440 volts 50 Hz complete all as specified and directed. |
| 28 | Supply & fix in repairs power factor correction capacitor, 15 KVAR, heavy duty 440 volts 50 Hz complete all as specified and directed. |
| 29 | Supply & fix in repairs APFC relay eta CON L series with auto-set function 3-8 stage, Model eta CON L3 complete all as specified and directed.Make:- L&T or equivalent make in Schneider / HPL / Indo Asian. |
| 30 | Supply & fix in repairs, capacitor duty contactor, type MOC built in auxiliary contact blocks, 8.5 KVAR, 415 volts, 3 phase, 50 Hz, type MO C 8.5 complete all as specified and directed. |
| 31 | Supply & fix in repairs, capacitor duty contactor, type MOC built in auxiliary contact blocks, 12.5 KVAR, 415 volts, 3 phase, 50 Hz, type MO C 8.5 complete all as specified and directed. |
| 32 | Supply & fix in repairs, capacitor duty contactor, type MOC built in auxiliary contact blocks, 15 KVAR, 415 volts, 3 phase, 50 Hz, type MO C 8.5 complete all as specified and directed. |
| 33 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 metre deep in soft / loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer-in-Charge. |
| 34 | Excavation in trenches not exc. 1.5 m wide and exc 1.5 meter but not exc 3.0 metre in depth in soft / loose soil and getting out and levelling of bottom surface to required level all as specified and directed by Engineer-in-Charge. |
| 35 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and as directed. |
| 36 | Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 37 | M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed.Note: Punned thickness (18 cm) shall be consider for measurement purpose |
| 38 | M&L laying well burnt old size bricks, sub class \\"B\\" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge. |
| 39 | M&L for 63 mm outer dia & 50 mm inner dia Double Walled Corrugated (DWC) HDPE pipe with all fittings, manufactured and tested according to IS 16205 (Part 24), laid in trenches, fixed to walls, laid on floors, fixed to poles, for protection of UG cable complete all as specified and directed by Engr-in-Charge. |
| 40 | M&L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations complete all as specified & directed. |
| 41 | M&L for PCC type B-1, 1:2:4 using (20 mm graded stone aggregate) for coping, including form work complete all as specified & directed. |
| 42 | Taking down dismantling of unsv LT UG cable complete all as specified and directed. |
| 43 | Supply and lay cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, laid in trenches / duct or fixed to wall / passing through pipe with suitable size crimping type cable lugs for stranded aluminium conductor of the following sizes complete all as specified and directed :-Notes : Earthwork, Sand and Covers shall be measured and paid separately. |
| 44 | 4 Core X 16 Sqmm |
| 45 | 4 Core X 25 Sqmm |
| 46 | 3.5 Core X 35 Sqmm |
| 47 | 3.5 Core X 50 Sqmm |
| 48 | 3.5 Core X 70 Sqmm |
| 49 | 3.5 Core X 95 Sqmm |
| 50 | 3.5 Core X 150 Sqmm |
| 51 | Supplying and fix 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed unarmoured twin core cable flat / round or circular size 10 sqmm 2 core. |
| 52 | Supplying and fix 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed four core cable flat or circular size 10 sqmm 4 core. |
| 53 | Taking out existing unwanted LT PCC pole by cutting from ground level and removed from site finishing the surface complete |
| 54 | Dismantling concrete struts, any size removed from site |
| 55 | Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6 mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including top street light bracket, painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30 cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2 m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide complete all as specified and directed.Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 56 | S&F new generation energy saving and environmental friendly long life LED street light made up to pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 1.0 Sqmm PVC insulated copper conductor twin core cable etc, fixing on pole with and , fixed to Pole in any position with flat iron clamps of size 30 x 6 mm GI pipe light grade breaker of 40mm dia of length 1200 mm including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed, fixing to wall/pole including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. |
| 57 | S&F New generation, post-top, energy saving, environmental friendly long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, with high power LED as light source of capacity 36 watts and all standard accessories etc fixed to main gate in any location and position complete all as specified and as directed. Make Cat Part No PCGLP 01400 of Make Polycab, Cat Part No HLPT-01-40-CW of Make Halonix, Cat Part No LLOP-30-C of make orient |
| 58 | S&F in repair LED Driver suitable for upto 72 watts LED light fittings complete all as specified and directed. Make : Philips / Wipro / H avells / ORIENT / Halonix. |
| 59 | S&F in repair LED Driver suitable for from 150W - 400W flood light watts LED light fittings complete all as specified and directed. Make : Philips / Wipro / Havells / ORIENT / Halonix. |
| 60 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed. |
| 61 | Supply and spread and levelling Graded coarse Aggregate in loose filling over dress earth surface of gauge 20-40 mm nominal size in the installation yard all as specified and as directed by Engr-in-Charge. |
| 62 | Trimming / pruning and removing of tree branches or any other foreign objects from HT / LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way / 4 way / 6 way conductor system. Notes: (i) The contractor is responsible for provision of Necessary T & P and safety equipment's to complete the job. |
| 63 | Deployment of tools & manpower for Boring /drilling (Horizontal) manually / mechanically under existing road max 10 M in width) suitable for passing pipe of any description of dia 40 to 100 mm complete all as specified and directed by Engineer in Charge |
| 64 | Supply & lay G I tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc including taking down old pipe all as specified and directed for following sizes :- |
| 65 | 40 mm dia bore |
| 66 | 50 mm dia bore |
| 67 | 100mm dia bore |
| 68 | Supply, install testing and commissioning weather and vermin proof LT bus bar junction box (Panel board) factory fabricated (CPRI approved) Outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle of size 50 mm x 50 mm x 6 mm for 60 cm height from ground level, suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable of sufficient Nos of circular cable entry holes at bottom only with suitable PVC / rubber / wooden bushes to prevent ingress of water / vermin etc, inside the enclosure, the required Nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone, including connecting with L.T armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium complete all as specified and directed by Engineer- in -charge( as per sample )and consisting of following :- |
| 69 | (a) Bus bars of Aluminium strips of 400 Amp current rating capacity, minimum 400 mm long or of length as actually required at site for 3 phase neutral, mounted on epoxy/FRP bus bar insulator complete with provision to connect 4 Nos cables with nut bolt fixing arrangement complete - 01 set(b) MCCB 160 Amp 4 Pole 25 KA rating fixed type- 1 Nos |
| 70 | M&L for ACSR conductor, steel reinforced for LT over head lines on poles including stretching tightening of poles insulator with binding wire of suitable size of ACSR conductor including disconnecting / taking out old existing unsv ACSR conductors complete all as specified and directed. |
| 71 | M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/taking out old existing unsv insulators complete all as specified and directed. |
| 72 | M&L for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/taking out old existing unsv insulators complete all as specified and directed. |
| 73 | S&F Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/taking out old existing unsv stay assembly complete all as specified and directed. |
| 74 | M/L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section, including nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint including disconnecting / taking out old existing unsv cross arms complete all as specified and directed. |
| 75 | S&F MCCB (Conforms to IEC:60947-II/IS:13947-II) in existing LT Panel box/Feeder Pillar boxes (KIOSK), Adjustable thermal and fixed magnetic setting of capacity 400 Amps, 4 Pole, 36 KA, 415 Volt including disconnecting / taking out existing old unsv / burned MCCB complete all as specified and directed. |
| 76 | All as per item No-45 here in before but of capacity 250 Amps, 4 pole, 35 KA |
| 77 | All as per item No-45 here in before but of capacity 200 Amps, 4 pole, 35/36 KA |
| 78 | All as per item No-45 here in before but of capacity 200 Amps, 4 pole, 25 KA |
| 79 | All as per item No-45 here in before but of capacity 160 Amps, 4 pole, 25 KA |
| 80 | All as per item No-45 here in before but of capacity 125 Amps, 4 pole, 25 KA |
| 81 | All as per item No-45 here in before but of capacity 100 Amps, 4 pole, 16 KA |
| 82 | All as per item No-45 here in before but of capacity 63 Amps, 4 pole, 16 KA |
| 83 | S&F MCB 63 Amp to 100 Amps, 4 pole, 415 Volts with breaking capacity 10KA, including disconnecting / taking out existing old unsv / burned MCB complete all as specified and directed. |
| 84 | S&F MCB, SP 6-32 Amps, 415 Volts with breaking capacity 10KA, including disconnecting / taking out existing old unsv / burned MCB complete all as specified and directed. |
| 85 | Taking down and relaying of existing exposed cable to underground of surface/re-using after jointing of straight through joint Kit of following sizes , complete all as specified and directed. (a) 3.5 Core 16 Sqmm to 240 Sqmm Note earth work shall be measured and paid separately. . |
| 86 | M&L for cutting of Road / PCC Hard standing / similar work, not exceeding 30 cm in width, not exceeding 45 cm in depth for passing of LT cable / Pipe etc, making good disturbed surface by returning filling with excavated material after laying of pipe / cable and top 20 cm portion filled with PCC (1:2:4) type B-1 using 20 mm graded aggregate, removing surplus excavated material to a distance not exceeding 50 metre complete all as specified and directed . |
| 87 | M&L for road crossing by adopting trench less boring work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by haidrolic pipe jacking technique complete including boring in any type of soils / hard rock, and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and as directed.Note: GI pipe shall be measured and paid separately. |
| 88 | M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including thoroughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos blue and 2 Nos white) from ground level, complete all as specified and directed. |
| 89 | M&L for Painting the existing LT PCC poles with 1 coats of weather proof exterior emulsion paint including painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 blue and 2 white) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black synthetic enamel paint on poles complete all as specified and directed. |
| 90 | Material and Labour for cleaning and removing of old paint of LT the panel, preparation of outer surface by grinder and remove all rusted portion, apply putty on rough surface, applying one coat of primer, spray painting of panel with two coats synthetic enamel paint of existing colour or Approved coloured as suggested Enr-in Charge complete including providing lock all as specified and directed . |
| 91 | Material and Labour for cleaning and removing of vegetation, bushes, surface dressing up depth not less than 10 cm to remove the vegetation up to root surrounding the all 11 KV Electric Installation premises all around approx. 25-30 Sqmtr area complete including providing lock all as specified and directed by Engr-in-charge.Note :- The cleaning vegetation required quarterly, cleaning of each Quarter measured one job for a installation. |
| 92 | Supply and fixing in repair steel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified. |
| 93 | Supply and fix in repair 1 Sqmm two core PVC insulated, PVC sheathed multistranded copper conductor flexible cable 1100 volts grade from junction box to street light fitting complete all as specified and directed by Engr in Charge. |
| 94 | S&F Junction box 290 x 200 x 130 mm Polycarbonate Hinged Enclosure box for cable in / out of street light LT cable, out door type, testing and commissioning with locking arrangements fixed on poles 4 pole 100 Amp Connector, including MCB SP - 01 Nos for connecting suitable size of XLPE UG cable all as specified and directed.Make Hensal / IDIS India / FINBOX |
| 95 | S&F On-Load changeover switch (In sheet steel enclosure), AC 21 (Side Handle), 4 pole of capacity 200 Amps, 415 Volts, 50 Hz, complete all as specified and directed. |
| 96 | Supply only of insulation tap roll of size 25 mm x 100 RM length for cable protection. |
| 97 | M&L for welding existing broken LT electric panel doors and fixing good quality hinges 2 Nos for each leaf of suitable size for making open and close the panel doors and fixing / welding angle / notch and Nut Bolts washers of suitable size to keep the door locked and including welding and making good any other broken portion of panel (double door also) complete all as specified and directed by Engr-In-Charge. |
| 98 | M& L for Repairing of LT Panel by cutting out Corroded / worn out body of LT Panel and supply & fixing 3.15 mm thick CRCA sheet with suitable Angle by suitable wielding, including painting of panel with approved colour by spray paint over a coat of red oxide primer complete. |
| 99 | M&L painting of LT panel / other electric equipment with one coat synthetic enamel paint by using approved colour of synthetic enamel paint by spray painting machine complete. |
| 100 | Deployment of manpower tools etc for Checking / testing of Earth resistance value of earthling Installed inside Harni camp and harni airfield area as requirement basis as directed by Engr in Charge or as schedule including pouring salted water ( 1 litre water with 300 gram salt) into earthing and bringing down the resistance value. including maintenance of existing earthing by cleaning the earth chamber funnel and cleaning of vegetation surrounding earthing pit up to 2 mtr. |
| 101 | Note: (i) The contractor will deploy a team for to test the resistance value of earthings in each zone to complete the process within one month. The entire process will be repeated as and when directed by engineer-in-charge upto completion of the contract. (ii) one earthing testing one time will be measured as one job for payment.(iii) Digital Earth tester will be arrange by the contractor his own. (iv) Date of testing and due date of testing is to be written on a register with sign of user rep & Engr-in Charge . (iv) Testing and correction action is to be done within one month from date of commencement . earthings is to be completed within one month. The contractor has to deploy electrician with helper and testing equipment and all the resources to complete the task within one month.(v) If any material required for improvement of resistance value which value is more than their permissible limit will be measured and paid separately. |
| 102 | M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed. |
| 103 | Earthing complete in repairs with galvanised steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as eGI strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed.Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order. |
| 104 | S&F in repair GI earth strip of size 32 x 6 mm buried in ground after testing point complete. |
| 105 | Supply and applying of power plus gel in 5 KG packaging for reducing Soil resistivity reducing /Earth resistance The gel applying in existing earth pit with diluted in water as directed by engineer-in-charge Make:- POWERTECH INDUSTRIES LTED PRAGATI / McML’s Earthing Solution (MES) / Ashlock |
| 106 | M&L for Spraying anti vegetation chemical mixed in water with spray machine to all 11 KV sub station harni camp and airfield complete all as specified and directed.Note:- anti vegetation chemical will be measured and paid separately as supply only. |
| 107 | Supply only anti vegetation chemical herbicide / weed killer complete all as specified and as directed. Make Tata Rallis, Bayer & UPL. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender