Tender For Annual Maintenance Contract (Routine, Preventive & Breakdown) Of 220/132/33Kv S/S Jhajhra And 132/33Kv S/S Purkul Against E-Tender Specification No.T-27/Se (O And M)/ Cr/D.Dun/2026-27
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Nov 2026
15 days left
EMD
75000
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance Contract (Routine, Preventive & Breakdown) Of 220/132/33Kv S/S Jhajhra And 132/33Kv S/S Purkul Against E-Tender Specification No.T-27/Se (O And M)/ Cr/D.Dun/2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Work For Annual Maintenance Contract (Routine, Preventive and Breakdown) at 220/132/33 KV S/S Jhajhra, Work of daily / routine maintenance activities through round the clock availability of highly skilled person and Supervisor as per scope of work for- |
| 2 | 3 Nos Highly Skilled person |
| 3 | 1Nos Experienced, ITI/ Diploma Supervisor |
| 4 | 220 KV Switch yard |
| 5 | (1) 220KV Bays - 9 Nos |
| 6 | (2) 220 KV Main Bus-1 |
| 7 | (3) 220 KV Main Bus-2 |
| 8 | (4) 220 KV Transfer Bus |
| 9 | (5) Power Transformer - 03 Nos (3*160MVA) T/F |
| 10 | 132 KV Switch yard |
| 11 | (1) 132 KV Bays - 10 Nos |
| 12 | (2) Power Transformer - 03 Nos 80 MVA (132/33 KV) T/F |
| 13 | (3) 132 KV Main Bus -1 |
| 14 | (4) 132 KV Main Transfer Bus |
| 15 | 33 KV Switch yard |
| 16 | (1) 33KV Bays - 13 Nos including capacitor bank bay |
| 17 | (2) 33 KV Main Bus |
| 18 | (3) 33 KV Transfer Bus |
| 19 | (4) 2 Nos 630KVA Substation Transformer Bays |
| 20 | Work comprises :- |
| 21 | (1) Routine visual checking thermovision scanning of red hot points, flash points, burned jumpers, CBs, Isolator, Bus Bar, CTs/PTs/CVTs, marshalling Box etc including scheduled cleaning, lubrication, tightening of connection/ jumpers, replacement of minor damaged parts of equipment, replacement of jumpers/clamps/connectors etc. |
| 22 | (2) Routine work of all power and station transformer, maintenance of their cooling fans, i.e oiling, greasing, cleaning etc, LT electrical connection, cleaning of oil collection pits, tightening of loose connection, replacing silica gel (Provided by department), provides help in oil top up as per directions of engineer in charge. |
| 23 | (3) Routine checking of complete length of control cable and power cables between indoor panels /equipment and outdoor equipments / Panels, cleaning replacement of damaged / burned cable, tightening and replacement of damaged terminals / connection / lugs etc. referruling whenever required. |
| 24 | (4) Routine maintenance of battery cells and battery chargers i.e. daily cleaning of battery room and battery cells, applying of petroleum jelly etc complete in all respect. |
| 25 | (5) Routine maintenance of indoor panels in C&R panels, ACDB, DCDB system, indoor outdoor illumination system etc including schedule cleaning, lubrication tightening of connectios / terminals, replacement of minor damaged parts of panels tracing of circuits. |
| 26 | (6) Any Others miscellaneous activity & helping in emergency situation. |
| 27 | Work For Annual Maintenance Contract (Routine, Preventive and Breakdown) at 132/33kV S/S Purkul, Work of daily / routine maintenance activities through round the clock Highly skilled person as per scope of work for- |
| 28 | 3 Nos Highly Skilled person |
| 29 | 132kV Switch yard |
| 30 | (1) 132kV Bays - 6 Nos |
| 31 | (2) Power Transformer - 02 Nos 40 MVA and 01 Nos 20 MVA (132/33 KV) T/F |
| 32 | (3) 132kV Main Bus -1 Nos |
| 33 | (4) 132kV Transfer Bus - 01 Nos. |
| 34 | 33 KV Switch yard |
| 35 | (1) 33KV Bays - 10 Nos including capacitor bank bay |
| 36 | (2) 33kV main bus - 03 Nos 2X40 MVA T/F and 1x20 MVA T/F |
| 37 | (3) 2 Nos 250KVA Substation Transformer. |
| 38 | Work comprises :- |
| 39 | (1) Routine visual checking thermovision scanning of red hot points, flash points, burned jumpers, CBs, Isolator, Bus Bar, CTs/PTs/CVTs, marshalling Box etc including scheduled cleaning, lubrication, tightening of connection/ jumpers, replacement of minor damaged parts of equipment, replacement of jumpers/clamps/connectors etc. |
| 40 | (2) Routine work of all power and station transformer, maintenance of their cooling fans, i.e oiling, greasing, cleaning etc, LT electrical connection, cleaning of oil collection pits, tightening of loose connection, replacing silica gel (Provided by department), provides help in oil top up as per directions of engineer in charge. |
| 41 | (3) Routine checking of complete length of control cable and power cables between indoor panels /equipment and outdoor equipments / Kiosk / Panels, cleaning replacement of damaged / burned cable, tightening and replacement of damaged terminals / connection / lugs etc. referruling whenever required. |
| 42 | (4) Routine maintenance of battery cells and battery chargers i.e. daily cleaning of battery room and battery cells, applying of petroleum jelly etc complete in all respect. |
| 43 | (5) Routine maintenance of indoor panels in C&R panels, ACDB, DCDB system, indoor outdoor illumination system etc including schedule cleaning, lubrication tightening of connections / terminals, replacement of minor damaged parts of panels tracing of circuits. |
| 44 | (6) Any Others miscellaneous activity & helping in emergency situation. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender