Tender For Proposal For Erection Of A Shed At 33/11 Kv Substation Premises For Storage Of Electrical Equipment And Maintenance Materials.
Tender Value
4.08 Lakhs
Estimated cost
Bid Submission
28 Oct 2026
6 days left
EMD
5109
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bokaro → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Proposal For Erection Of A Shed At 33/11 Kv Substation Premises For Storage Of Electrical Equipment And Maintenance Materials.
BOQ
| Sl. No. | Item Description |
| 1 | Proposal for erection of a shed at 33/11 KV Substation premises for storage of electrical equipment and maintenance materials. |
| 2 | MS square pipe |
| 3 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil |
| 4 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 5 | Labour for Shed work |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 foundation & plinth in cement mortar 1:6 |
| 8 | Providing and fixing percolated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 9 | Wiring for light point/fan/exhaust fan point' call bell point with 1.5 sqm. FR PVC insulted copper conductor single core cable in surface/recessed PVC conduit with piono type switch,, phenolic laminated sheet suitable size MS box and earthing the point with 1.5 sqm FR PVC insulated copper conductor single core cable etc. as required. Rate as per CPWD GROUP-B |
| 10 | Wiring for light point/fan/exhaust fan point' call bell point with 1.5 sqm. FR PVC insulted copper conductor single core cable in surface/recessed PVC conduit with piono type switch,, phenolic laminated sheet suitable size MS box and earthing the point with 1.5 sqm FR PVC insulated copper conductor single core cable etc. as required. Rate as per CPWD GROUP-C |
| 11 | Supplying and fixing 5 amp angula batten holders on the existing junction box/wooden block including connections etc. as required. |
| 12 | Supplying and fixing 3 pin 5 amp. Ceiling rose on the existing junction box /wooden block including connection etc. as required. |
| 13 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. required. |
| 14 | Wiring for circuit/submain wiring along with earth wire with size 2 X 2.0 sq.mm earth wire of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required |
| 15 | Wiring for circuit/submain wiring along with earth wire with size 2 X 2.5 sq.mm + 2.5 sq. mm each wire of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required |
| 16 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnections, powder painted including earthing etc. as required(but without MCB/RCCB/Isolator) 2 + 4 way single door. |
| 17 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender