Drinking Water Supply and Sanitation Government Departments Closing in 4 days TDR #58116400

Tender For Annual Rate Contract Of Repairing Work Of Starter Panel In Various Schemes Under City Sub Division Chittorgarh.

Issued by Government Departments · Chittorgarh, Rajasthan
Tender Value
4 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
4 days left
EMD
8000
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chittorgarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Annual Rate Contract Of Repairing Work Of Starter Panel In Various Schemes Under City Sub Division Chittorgarh.

BOQ

Name of Work:- Annual rate contract of repairing work of starter panel in various schemes under City sub division Chittorgarh.
Sl. No. Item Description
1P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay, Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT's, provision for potential free contacts making connection, testing etc. as required. All as perStar - Delta Starter with following Motor rating
2Motor rating 4.0 KW
3Motor rating 5.5 KW
4Motor rating 7.5 KW
5Motor rating 9.0 KW
6Motor rating 11.0 KW
7Motor rating 15.0 KW
8Motor rating 18.5 KW
9Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical Annexure \\"A\\" attached with this BSR .
10Up to 14 Amp
1114 to 23 Amp
1220 to 33 Amp
13SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB)made of flame retardent & heat resistant material having followingcurrent rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4 pole MCCB With Thermal Magnetic release
14up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting
15up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
16Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
171 x 1.5 sq.mm
181 x 4.0 sq.mm
191 x 6.0 sq.mm
201 x 10.0 sq.mm
21P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
2212.0 mm thick
23Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
24Above 5 HP and up to 10 HP
25Above 10 HP and up to 15 HP
26Above 15 HP and up to 20 HP
27Above 20 HP and up to 30 HP
28Labour charges for removing electric fault in wiring/making connection through lugs (with the help of cramping tool) of motor pump set with starter at headworks of water supply scheme/Tubewell/Openwell including cost of insulation tape etc.
29Labour charges for replacment of defective empere meter/volt meter with new on existing panel board in pump house./Tubewell/Openwell (new voltmeter/ampere meter will be provided by department.
30Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site. (Parts will be supplied by department.)
315 to 15 HP
3216 to 30 HP Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58116400
AUTHORITY Government Departments
TENDER VALUE 4 Lakhs
LAST DATE 29-10-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Annual Rate Contract Of Repairing Work Of Starter Panel In Various Schemes Under City Sub Division Chittorgarh.
Basic Detail
Tender No nit34to41 ee phed cor
Bidding Type Tender
Location
City Chittorgarh
State Rajasthan
Key Dates
Publish Date 19 Oct 2026
Submission Date 29 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 4 Lakhs
Tender Fee 200
EMD 8000
Exemption Available
Document List
24b90b36-160d-489b-a33f-6a5d978c8cb0.html
BOQ_1071941.xls
td37.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

24b90b36-160d-489b-a33f-6a5d978c8cb0.html

xls

BOQ_1071941.xls

pdf

td37.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender