Tender For Annual Rate Contract Of Repairing Work Of Starter Panel In Various Schemes Under City Sub Division Chittorgarh.
Tender Value
4 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
4 days left
EMD
8000
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chittorgarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Rate Contract Of Repairing Work Of Starter Panel In Various Schemes Under City Sub Division Chittorgarh.
BOQ
| Sl. No. | Item Description |
| 1 | P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay, Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT's, provision for potential free contacts making connection, testing etc. as required. All as perStar - Delta Starter with following Motor rating |
| 2 | Motor rating 4.0 KW |
| 3 | Motor rating 5.5 KW |
| 4 | Motor rating 7.5 KW |
| 5 | Motor rating 9.0 KW |
| 6 | Motor rating 11.0 KW |
| 7 | Motor rating 15.0 KW |
| 8 | Motor rating 18.5 KW |
| 9 | Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical Annexure \\"A\\" attached with this BSR . |
| 10 | Up to 14 Amp |
| 11 | 14 to 23 Amp |
| 12 | 20 to 33 Amp |
| 13 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB)made of flame retardent & heat resistant material having followingcurrent rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4 pole MCCB With Thermal Magnetic release |
| 14 | up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting |
| 15 | up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 16 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 17 | 1 x 1.5 sq.mm |
| 18 | 1 x 4.0 sq.mm |
| 19 | 1 x 6.0 sq.mm |
| 20 | 1 x 10.0 sq.mm |
| 21 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 22 | 12.0 mm thick |
| 23 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 24 | Above 5 HP and up to 10 HP |
| 25 | Above 10 HP and up to 15 HP |
| 26 | Above 15 HP and up to 20 HP |
| 27 | Above 20 HP and up to 30 HP |
| 28 | Labour charges for removing electric fault in wiring/making connection through lugs (with the help of cramping tool) of motor pump set with starter at headworks of water supply scheme/Tubewell/Openwell including cost of insulation tape etc. |
| 29 | Labour charges for replacment of defective empere meter/volt meter with new on existing panel board in pump house./Tubewell/Openwell (new voltmeter/ampere meter will be provided by department. |
| 30 | Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site. (Parts will be supplied by department.) |
| 31 | 5 to 15 HP |
| 32 | 16 to 30 HP Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender