Tender For Repair / Mainteance Of Lt Panel / Feeder Piller Godos, Mccbs And Connected Works At Saa Under Ge (S) Tezpur.
Tender Value
35 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
9 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Mainteance Of Lt Panel / Feeder Piller Godos, Mccbs And Connected Works At Saa Under Ge (S) Tezpur.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing in replacement of Indoor/Outdoor LT cable end termination jointing kit ,1100 volt grade (earthed) 3.5/4 core 400 sqmm aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location complete all as specified and directed |
| 2 | All as in Item No - 01, but for 3.5 core 240 to 300 Sqmm complete all as specified and directed |
| 3 | All as in Item No - 01, but for 3.5/4 core 150 to 185 Sqmm complete all as specified and directed |
| 4 | All as in Item No - 01, but for 3.5/4 core 70 to 120 Sqmm complete all as specified and directed |
| 5 | All as in Item No - 01, but for 3.5/4 core 25 to 50 Sqmm complete all as specified and directed |
| 6 | All as in Item No - 01, but for 3.5/4 core 6 to 16 sqmm complete all as specified and directed |
| 7 | Supply and fixing of MCCB 400 amps, 4 pole,415 Volt microprocessor based type with breaking capacity 36 KA, and 100 % Icu including spreader terminals and Suitable for Isolation Adjustable Over Load setting ,Adjustable Short Circuit setting, ,Wide Range of snap fit Internal and External Accessories including Taking down MCCB complete all as specified and directed by Engineer-in-charge. |
| 8 | All as in Item No-07, But for 250 Amps.complete all as specified and directed |
| 9 | All as in Item No-07, But for 200 Amps.complete all as specified and directed |
| 10 | All as in Item No-07, But for 160 Amps.complete all as specified and directed |
| 11 | Supply and fixing of MCCB 100 amps, 4 pole,415 Volt Adjustable type with breaking capacity 16 KA, and 100 % Icu including spreader terminals and connected acessories complete all as specified and directed. |
| 12 | All as in Item No-11, But for 63 Amps. complete all as specified and directed |
| 13 | Supply, fixing and connecting in replacement of Manual On Load change over switch with sheet steel enclosure rating 63 Amps 4 pole, 440 volts grade in sheet metal enclouser fixing in surface of wall on wooden board with making all coonection, gland etc complete all as specified and directed |
| 14 | All as in Item No- 13, But for 100 Amps. complete all as specified and directed |
| 15 | All as in Item No- 13, But for 200 Amps.complete all as specified and directed |
| 16 | All as in Item No- 13, But for 400 Amps complete all as specified and directed |
| 17 | Supply /laid/ fixing/ connecting and testing in replacement of the following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 300 Sqmm x 3.5 core complete all as specified and directed |
| 18 | All as in Item No- 17 but for 240 Sqmm x 3.5 core complete all as specified and directed. |
| 19 | All as in Item No-17 but for 185 Sqmm x 3.5 core complete all as specified and directed. |
| 20 | All as in Item No-17 but for 120 Sqmm x 3.5 core complete all as specified and directed |
| 21 | All as in Item No- 17 but for 95 Sqmm x 3.5 core complete all as specified and directed |
| 22 | All as in Item No- 17 but for 50 Sqmm x 3.5 core complete all as specified and directed |
| 23 | All as in Item No- 17 but for 16 Sqmm x 4 core complete all as specified and directed |
| 24 | Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, etc. complete all as specified and as directed. |
| 25 | Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 26 | Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.. |
| 27 | M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230 mm spreding thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and as directed. Note : punned thickness will only be measured for payment purpose. |
| 28 | M&L for sub class 'B' brick for protection of UG cable in tranches of old size brick complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| 29 | M&L for sub class 'B' brick for protection of UG cable in tranches of old size brick complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender