Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58115564

Tender For Provn Of 12 X Solar Street Light At Army Public School Tezpur At Solmara Military Station And Underground Electric Cabling For Otm Accn Of 4004 Fd Hosp Under Ge (N) Tezpur

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
18.91 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
18 days left
EMD
37900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of 12 X Solar Street Light At Army Public School Tezpur At Solmara Military Station And Underground Electric Cabling For Otm Accn Of 4004 Fd Hosp Under Ge (N) Tezpur

BOQ

Name of Work:- PROVN OF 12 X SOLAR STREET LIGHT AT ARMY PUBLIC SCHOOL TEZPUR AT SOLMARA MILITARY STATION AND UNDERGROUND ELECTRIC CABLING FOR OTM ACCN OF 4004 FD HOSP UNDER GE (N) TEZPUR
Sl. No. Item Description
1BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : PROVN OF 12 X SOLAR STREET LIGHT AT ARMY PUBLIC SCHOOL TEZPUR AT SOLMARA MILITARY STATION AND UNDERGROUND ELECTRIC CABLING FOR OTM ACCN OF 4004 FD HOSP UNDER GE (N) TEZPUR Contract No : GE(N)/TEZ/ OF 2026-2027 (8299/E8) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words)
2Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ.
3Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 35 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ.
4Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 50 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ.
5Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 70 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ.
6M&L for GI pipe 40 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. including taking up old unserviceable existing complete all as specified and directed.
7M&L for GI pipe 80 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. including taking up old unserviceable existing complete all as specified and directed.
8M&L LT cable jointing kit heat shrinkable type 1100 V grade 70 Sqmm of size all as specified and directed
9M&L LT cable jointing kit heat shrinkable type 1100 V grade 50 Sqmm of size all as specified and directed
10M&L LT cable jointing kit heat shrinkable type 1100 V grade up to 35 Sqmm of size all as specified and directed
11S & F in replacement Moulded Case Circuit Breaker (MCCB), 63Amps 16KA, 4P, 415V, 50 Hz, Adjustable Thermal & Fixed magnetic type Conforms to IS13947-2 & IEC-60947-2 Ics=100%Icu as per IEC 60947-II,Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge.
12S & F in replacement Moulded Case Circuit Breaker (MCCB), 100Amps 25KA, 4P, 415V, 50 Hz, Adjustable Thermal & Fixed magnetic type Conforms to IS13947-2 & IEC-60947-2 Ics=100%Icu as per IEC 60947-II,Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge.
13S & F in replacement Moulded Case Circuit Breaker (MCCB), 40Amps 25KA, 3P, 415V, 50 Hz, Adjustable Thermal & Fixed magnetic type Conforms to IS13947-2 & IEC-60947-2 Ics=100%Icu as per IEC 60947-II,Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge.
14M & L Air termination, single pointed, copper rod 12mm dia and 300mm long icluding necessary fixing arrangement using MS clamps,nuts & bolts complete all as specified and directed.
15S & F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed
16M & L Alluminium strip 25 x 3.15 mm with procelain saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
17S & F Galvanised iron strip 32 x 6mm buried in ground or fixed to Roof, Walls by using appropriate insulating Boxes with screws complete all as specified and directed.
18Supply and fixing copper strip 32 x 6 mm fixed in ducts / on wall / in trenches / floors etc for earthing complete fixed to equipment / test point / earth electrode complete all as specified and directed
19Supply and fix LT cable tray of suitable size not less than 350 X 25 X 2.5mm GI Perforated Tray all as specified and directed.
20Supply and fix LT cable tray of suitable size not less than 300 x 60 x 50 mm PVC Perforated Tray all as specified and directed.
21Material and labour for PCC 1:3:6 type C-2 using 20 mm graded stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement including demolition of old unserviceable existing PCC work complete all as directed and specified
22Cutting of wall/hard standing for laying of cables and making good the existing surface with using PCC type B1 (1:2:4) using 20mm graded aggregate excavation and earth work complete all as specified and directed
23Supply, install, testing & commissioning of LT busbar chamber of size (0.60x0.60x1.0)m CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 50X50X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete including PCC foundation comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS:The bus-bars shall be made up of 04 Nos Aluminium 600 A rated not less than 60mmx10 mm, duly insulated with 1100 V grade standard colour coded PVC sleeves PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.INSTRUMENTATION SYSTEM :(a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(b) 3 Ph Digital Voltmeter CI 1.0 - 01 No (c) MCCB 200Amp,4P,25KA -01Nos (d)Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 01 Nos.NOTE : 1) Design / Drawing / BOM of the LT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
24Supply, Installation, Testing and Commissioning of all in one integrated LED solar street fitting 85 watt consists of solar photovoltaic module, battery, battery management system, control electronics, LED driver, PIR sensor, inter-connecting cables and pole mounting piece integrated into the luminaire as asingle unit. Solar street light with IP65 ingress protection having a 2000 lumen output, 28Wp high efficiency polycrystalline solar panel, highly efficient MPPT based charge controller and 12.8 V, 13.6 Ah IP68 Lithium Ferro Phosphate(LiFePO4) battery with proper battery management system. LED lumen efficacy shall be at least 175lm/W and LED driver should have >90% efficiency. Typical correlated colour temperature should be 5700K with CRI>70. It should have a PIR sensor to ensure battery optimisation with help of a suitable dimming profile. The luminaire should be housed in IK 08 impact resistance certified aluminum pressure diecast housing with anti- corrosive coating and must have a UV stabilized polycarbonate cover. The luminaire shall have a specially designed pole mounting piece that enables lateral as well as post top mounting and installation at varying tilts from 0 to 15 degrees for optimal light distribution including suitable galvanized steel pole of suitable lenght complete all as specified and as directed by Engnr-in-charge.
25Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations etc, or for shafts, wells, cesspits, man holes, pier holes etc not exc 10 sq m on plan and getting out in soft / loose soil complete all as specified and directed.
26Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
27Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
28Material and labour for sand cushioning for cable protection using clean dry sand complete all as specified and directed.
29Supply and laying in trenches brick common burnt clay building brick, sub class 'B' designated- 75 with width equal to length of brick for cable protection complete.
30Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for inserting GI tubing upto 100 mm bore complete all as specified and directed.
31Materials and labour for earthing complete with MS galvanised steel earth plate electrode 600mm x 600mm x6mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level, connected with 32x6mm galvanised iron or steel earthing lead to be protected by galvanized iron pipe 40mm bore (medium grade) and other end connected to earthing test point including providing funnel and watering pipe 20mm bore galvanized iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate) 50 mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work, excavation, returned filling and removal of surplus earth upto a distance not exceeding 50 m etc all shown on electrical plate No. 3 of MES schedule Part-I (2009) complete including test point and testing on completion, complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58115564
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 18.91 Lakhs
LAST DATE 07-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 12 X Solar Street Light At Army Public School Tezpur At Solmara Military Station And Underground Electric Cabling For Otm Accn Of 4004 Fd Hosp Under Ge (N) Tezpur
Basic Detail
Tender No GE(N)/TEZ/2026-2027/8299
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 17 Oct 2026
Submission Date 07 Nov 2026
Open Date 09 Nov 2026
Finance
Tender Value 18.91 Lakhs
Tender Fee 500
EMD 37900
Exemption Available
Document List
BOQ_891318.xls
deb5e457-17cc-436d-8350-bd66bf72f5e9.html
ReTender8299.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_891318.xls

html

deb5e457-17cc-436d-8350-bd66bf72f5e9.html

pdf

ReTender8299.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender