Tender For Repair / Replacement Of Road Guard Post, Perimeter Fencing Wall Led Street Light, Flood Lights And Landscape Lightning Including Replacement Of Unserviceable Cable Time Switches Contactors Etc At installation Hamla Under Ge(Nw) Bhandup
Tender Overview
Project Description
Tender for Repair / Replacement Of Road Guard Post, Perimeter Fencing Wall Led Street Light, Flood Lights And Landscape Lightning Including Replacement Of Unserviceable Cable Time Switches Contactors Etc At installation Hamla Under Ge(Nw) Bhandup
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre depth for laying of UG cable etc and getting out in soft / loose soil, complete all as specified and as directed. |
| 2 | Returning, filling in including spreading, leveling, watering and ramming in layers not exceeding 25 cm thick in soils, complete all as specified and directed. |
| 3 | Removing surplus excavated soil to a distance not exceeding 50.00 metre away and depositing where directed at a level not exceeding 1.50 metre above the starting point, complete all as specified and directed. |
| 4 | Material and labour for cable route marker made of Pre-cast cement concrete block masonry type C1 (1:3:6) (20 mm graded aggregrate) with solid blocks, exceeding 10 cm in width and setting in cement concrete mortar (1:6), including embosing DANGER / LT CABLE / MES on cable route marker and properly painting with approved colour, size of cable route marker 900 x 300 x 100 mm complete buried in ground for a depth of 45 cm & necessary earth work complete all as specified and directed |
| 5 | Supply and laying across road crossing reinforced concrete pipes, class NP2, laid and jointed complete with collars of size 250 mm complete all as specified and as directed |
| 6 | Supply and laying across road crossing reinforced concrete pipes, class NP2, laid and jointed complete with collars of size 300 mm complete all as specified and as directed |
| 7 | Material and labour for soling (or sub base) 150 mm spread thickness with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed. |
| 8 | M & L for cement concrete (1:3:6) (40mm graded aggregate) type C2 as in foundation of poles, stays, grouting of panel and making good disturbed road surfaces including necessary formwork (as / if required) complete all as specified and as directed. |
| 9 | M & L for cement concrete (1:2:4) type B1 using (20 mm graded aggregate) as in coping of poles, etc. and finishing the concrete surfaces fair and even including necessary formwork required at site(s), complete all as specified and as directed. |
| 10 | Supply & laying LT Aluminium conductor power cables, stranded conductor, XLPE insulated, cores laid up, PVC inner sheathed, armoured galvanised steel strip, extruded PVC type ST2 outer sheathed, 1100 V grade as per IS 7098 (Part 1) 1988 with upto date amendments, cross-sectional area 50 Sqmm 3½ core, passing in HDPE pipe laid in trenches / fixing on surface of wall in cable tray securing with GI cable clamps including brass cable glands at termination end points mild steel flat iron clamps of adequate size, etc. and testing complete all as specified and as directed. |
| 11 | Supply & laying LT Aluminium conductor power cables, stranded conductor, XLPE insulated, cores laid up, PVC inner sheathed, armoured galvanised steel strip, extruded PVC type ST2 outer sheathed, 1100 V grade as per IS 7098 (Part 1) 1988 with upto date amendments, cross-sectional area 35 Sqmm 3½ core, passing in HDPE pipe laid in trenches / fixing on surface of wall in cable tray securing with GI cable clamps including brass cable glands at termination end points mild steel flat iron clamps of adequate size, etc. and testing complete all as specified and as directed. |
| 12 | Supply & laying LT Aluminium Conductor Power Cables, stranded conductor, XLPE insulated, cores laid up, PVC inner sheathed, armoured galvanised steel strip, extruded PVC Type ST2 outer sheathed, 1100 V grade as per IS 7098 (Part 1) 1988 with upto date amendments, cross-sectional area 25 Sqmm 4 core, passing in HDPE Pipe laid in trenches / fixing on surface of wall in cable tray securing with GI cable clamps including brass cable glands at termination end points mild steel flat iron clamps of adequate size, etc. and testing complete all as specified and as directed. |
| 13 | Supply & laying LT Aluminium Conductor Power Cables, stranded conductor, XLPE insulated, cores laid up, PVC inner sheathed, armoured galvanised steel strip, extruded PVC type ST2 outer sheathed, 1100 V grade as per IS 7098 (Part 1) 1988 with upto date amendments, cross-sectional area 16 Sqmm 4 core, passing in HDPE pipe laid in trenches / fixing on surface of wall in cable tray securing with GI cable clamps including brass cable glands at termination end points mild steel flat iron clamps of adequate size, etc. and testing complete all as specified and as directed. |
| 14 | Supply & laying LT Aluminium Conductor Power Cables, stranded conductor, XLPE insulated, cores laid up, PVC inner sheathed, armoured galvanised steel strip, extruded PVC type ST2 outer sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto date amendments, cross-sectional area 10 Sqmm 4 core, passing in HDPE pipe laid in trenches / fixing on surface of wall in cable tray securing with GI cable clamps including brass cable glands at termination end points mild steel flat iron clamps of adequate size etc. and testing complete all as specified and as directed. |
| 15 | Laying only LT UG cable of any description and size (serviceable cable obtained from item No.16 here-in-after), laid in trenches / on surface of wall / along with pole in and passing through cable protection pipe & connecting to end termination point, switch fuse unit and testing, complete all as specified and as directed. |
| 16 | Taking down / out unserviceable UG Cables of any cross sectional area and connections and joints including pipes, bricks, etc of any description laid in trenches or fixed with walls / poles, segreating serviceable bricks / precast covers, pipes, cables etc, and keep in safe custody for reuse, or carrying to store complete all as specified and as directed. NOTE : Earthwork will be measured and paid under appropriate items. |
| 17 | Supply and laying corrosion - resistant, non-porous, high-density polyethylene (HDPE) pipe (Material PE-80) of size 50 mm, (1.5\\"), Pressure Rating (PN) : 6 kg/cm², SDR-21 wall thickness not less than 2.3 mm laid in trenches along with accessories complete for electrical usage as in cable protection pipe to protect cable from external physical damage complete all as specified and as directed. |
| 18 | Supply and laying corrosion - resistant, non-porous, high-density polyethylene (HDPE) Pipe (Material PE-80) of size 63 mm, (2 \\"), pressure rating (PN) : 6 kg/cm², SDR-21 wall thickness not less than 3 mm laid in trenches along with accessories complete for electrical usage as in cable protection pipe to protect cable from external physical damage complete all as specified and as directed. |
| 19 | Supply and laying corrosion - resistant, non-porous, high-density polyethylene (HDPE) Pipe (Material PE-80), size 75 mm (2.5 \\"), Pressure rating (PN) : 6 kg/cm², SDR-21 wall thickness not less than 3.57 mm laid in trenches along with accessories complete for electrical usage as in cable protection pipe to protect cable from external physical damage complete all as specified and as directed. |
| 20 | Supply and fixing PVC insulated and PVC round sheathed, 1.50 sqmm 3 core multicore annealed bare copper conductor (flexible) industrial cable for voltage grade 1100 Volt, conforming to IS 694 : 2010 complete all as specified and as directed. |
| 21 | Supply and fixing PVC insulated and PVC round sheathed, 1.0 sqmm 3 core multicore annealed bare copper conductor (flexible) industrial cable for voltage grade 1100 Volt, conforming to IS 694 : 2010 complete all as specified and as directed. |
| 22 | Supply and fixing in repairs heavy duty, easy to install, open type bakelite connector plate, 100 Amps 4 bolt type (TPN) 1100 volts grade with necessary nuts bolts and washers of adequate size, length and mounting support complete all as specified and as directed. |
| 23 | Supply and fixing in repairs heavy duty, easy to install, open type bakelite connector plate, 63 Amps 4 bolt type (TPN) 1100 volts grade with necessary nuts bolts and washers of adequate size, length and mounting support complete all as specified and as directed. |
| 24 | Supply and fixing in repairs high efficient, roadway (street) lighting luminaire, LED 90 wattage system (top opening 1-3W LED 100Lm/W) as light source, powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution, higher spacing between poles and maintenance - free system fitting. Make-Orient, Philips or Jaquar (OSL-GRY-LSRT015090XW) or equivalent make as approved by GE complete all as specified and as directed. |
| 25 | Supply and fixing in repairs high efficient, roadway (street) lighting luminaire, LED 70 wattage system as light source, powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution,higher spacing between poles and maintenance-free system fitting. Make-Orient, Philips or Jaquar (OSL-GRY-LSRT015070XW) or equivalent make as approved by GE complete all as specified and as directed. |
| 26 | Supply and fixing in repairs high-pressure die-cast aluminum with individual lens and PC cover flood light luminaire LED 100 W white IP66 10 kv 11000 lumen, as light source, powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, option of multiple wattages in both wide and narrow beam complete. Make - Orient, Philips) or Jaquar (OFL-GRY-LFLDSLS100XW) or equivaalent make as approved by GE complete all as specified and as directed. |
| 27 | Supply and fixing in repairs high-pressure die-cast aluminum with individual lens and PC cover flood light luminaire LED 150 W White IP66 10 kv 11000 lumen, as light source, powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, option of multiple wattages in both wide and narrow beam complete. Make-Orient, Philips) or Jaquar ( OFL-GRY-LFLDSLS150XW) or equivalent make as approved by GE complete all as specified and as directed. |
| 28 | Supply and fixing in repairs high-pressure die-cast aluminum with individual lens and PC cover flood light luminaire LED 200 W White IP66 10 kV 11000 Lumen, as light source, powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, option of multiple wattages in both wide and narrow beam complete. Make-Orient, Philips) or Jaquar ( OFL-GRY-LFLDSLS200XW) or equivalent make as approved by GE complete all as specified and as directed. |
| 29 | Supply and fixing, outdoor, decorative pole mounted, energy saving, long life aesthetically designed die-cast aluminium luminaire with high power 50 wattage system LED as light source, 240 Volts, Make - Jaquar Cat No-OGL-BLK-SLERALDCD050WWT0 or equivalent in crompton, Philips or equivalent make as approved by GE, powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests. Elegantly designed spun aluminum housing and heat sink for efficient thermal management, sturdiness and excellent corrosion resistance. Lens - Heat resistant toughened bell shaped transparent acrylic diffuser, powder coated black after phosphochromate treatment. Ingress protection (IP Rating) IP65, complete light fitting including taking down existing unserviceable complete all as specified and as directed |
| 30 | Supply and fixing in repairs LED Post top ring lighting luminaire, 40 watt system LED as light source, 240 Volts. Make Jaquar Cat No-OGL-BLK-PTRING01FD40WWT0 or equivalent in Philips, orient or equivalent make as approved by GE, powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests elegantly designed die-cast aluminium housing and high grade aluminum heat sink for efficient thermal management, studiness and excellent corrosion resistance. 2 nos die-cast aluminium arms provided to support the housing. Powder coated black after phosphochromate treatment fitting complete all as specified and as directed. |
| 31 | Supply and fixing in repairs LED aurora post-top lantern luminaire IP65 Rated Power 30 watt elegantly designed spun aluminium and high grade aluminium heat sink for efficient thermal management, sturdiness and excelent corrosion resistance. MS base provided to support the housing. Powder coated black after phosphocromate treatment Make - Orient / Equivalent in Lucar Philips, Jaquar ( OGL-BLK-PTAURORCD030CWT0) or equivalent make as approved by GE. |
| 32 | Supply and fixing in repairs landscape architectural outdoor lighting, LED bollard circular disc 10W warm white, die cast aluminium housing opal diffuser with in-built LED, 140 V - 270 V AC, Ingress protection (IP Rating) IP65, typically giving off light from the sides, suitable to illuminate walkways, steps or pathways. Make - Orient, Philips or Jaquar (OBL-GRY-LBLDDSC010XW) or equivalent make as approved by GE, complete all as specified and as directed. Note - PCC for foundation required shall be measured and paid seperately under relevant item of schedule,However nuts bolts washers of suitable size for embedding fitting in foundation shall deemed to be included in the unit rate quoted. |
| 33 | Dismantling unserviceable Steel tubular / Pipe Poles of any description and any size setting aside for reuse or transporting to store for stacking including demolition of cement concrete (as / if required) and made good disturbed ground, complete all as specified and as directed.NOTE : (i) Unserviceable poles will be dismantled at ground level and disturbed ground shall be made good as directed for which Earthwork, demolition of cement concrete, etc. will not be measured and paid separately.(ii) Earth work, demolition of cement concrete for taking out serviceable poles below ground level will be measured and paid seperately under relevant item |
| 34 | Erecting only LT Steel Tubular Swaged / Hot-Dip Galvanized (HDG) Octagonal Poles with decorative single / double arm bracket of any size / description upto 8.5 metres long including, mild steel bolts, nuts, screws, for (serviceable pole obtained from Item No. 33 here-in-before) complete all as specified and as directed.NOTE :–(a) Earthwork, cement concrete, etc. will be measured and paid under approprite Items.(b) Cost of transporting the Serviceable Pole to location of work within 500 mtr is deemed to be included in the quoted unit rate.(c) Foundation bolts (4 nos with 3 nos of nuts and washers in each) for hot-dip galvanized (HDG) octagonal poles as recommended by OEM for serviceable poles to reuse at same or other location shall be provided by the contrator without any extra cost from the department. |
| 35 | Supply and fixing made to assembly double arm bracket 1.5 mtr long suitable for 70 mm top octagonal pole complete all as specified and as directed |
| 36 | Supply and fixing made to Assembly double arm bracket two metre long suitable for 70 mm top octagonal pole complete all as specified and as directed. |
| 37 | Supply & erecting Hot-Dip Galvanized (HDG) Octagonal poles for street lighting in single section of seven metre height, top – 70 mm dia, bottom – 130 mm dia and 3 mm thickness sheet, base plate of minimum dimension 200mm x 200mm x 12 mm, including foundation bolts (4 nos with 3 nos of nuts and washers in each), with decorative single arm bracket for mounting the light fittings 1000 mm long, bent at an angle of 120 degree, with necessary holding brackets, hold fasts etc, bakelite sheet with one 6A SP MCB and stud connector (4 nos) inside the pole at door opening for cable connection, complete all as specified and as directed. NOTE : Earthwork, cement concrete for foundation, etc. will be measured and paid under approprite items. However steel required for foundation in planting and securing foundation bolt as recommended by OEM is deemed to be included in the QUOTED UNIT RATE. Please Enable Macros to View BoQ information |
| 38 | Supply & erecting Hot-Dip Galvanized (HDG) Octagonal poles for street lighting in single section of seven metre height, top – 70 mm dia, bottom – 130 mm dia and 3 mm thickness sheet, base plate of minimum dimension 200mm x 200mm x 12 mm, including foundation bolts (4 nos with 3 nos of nuts and washers in each), with decorative single arm bracket for mounting the light fittings 1000 mm long, bent at an angle of 120 degree, with necessary holding brackets, hold fasts etc, bakelite sheet with one 6A SP MCB and stud connector (4 nos) inside the pole at door opening for cable connection, complete all as specified and as directed. NOTE : Earthwork, cement concrete for foundation, etc. will be measured and paid under approprite items. However steel required for foundation in planting and securing foundation bolt as recommended by OEM is deemed to be included in the QUOTED UNIT RATE. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender