Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #58115525

Tender For Repair And Maintenance Of Transformers, Vcb, Rmu, Battery Charger, Relay And Connected Items At Cassel Road Sub Stn, Urban Village, Mall Road, Polo Road, Church Road, Tigris Road, Did Line, 19Haa, Station Road, Mandir Marg, Maude Road, 4 N

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
49 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
15 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Transformers, Vcb, Rmu, Battery Charger, Relay And Connected Items At Cassel Road Sub Stn, Urban Village, Mall Road, Polo Road, Church Road, Tigris Road, Did Line, 19Haa, Station Road, Mandir Marg, Maude Road, 4 No P/F, Harbaksh Stadium, Tubarak Lines, 972 Tpt Coy, Mech C And Adjoining Area Of Age Elect Supply Sldc Under Ge (U) Elect Supply Delhi Cantt-10

BOQ

Name of Work:- REPAIR AND MAINT OF TRANSFORMERS, VCB, RMU, BATTERY CHARGER, RELAY AND CONNECTED ITEMS AT CASSEL ROAD SUB STN, URBAN VILLAGE, MALL ROAD, POLO ROAD, CHURCH ROAD, TIGRIS ROAD, DID LINE, 19HAA, STATION ROAD, MANDIR MARG, MAUDE ROAD, 4 NO P/F, HARBAKSH STADIUM, TUBARAK LINES, 972 TPT COY, MECH C AND ADJOINING AREA OF AGE ELECT SUPPLY SLDC UNDER GE (U) ELECT SUPPLY DELHI CANTT-10
Sl. No. Item Description
1Supply, installation and testing in replacement Numerical Relay draw out type in HT 11 KV VCB Panel comprising of new and modern numerical scheme for detecting, indicating and tripping the breaker on faults over-current and earth-fault in any of the three phases, Trip circuit supervision relay, 5% pick up for OC and 5% for EF. The relay shall also have the following features as minimum complete all as specified and directed by Engr-in-Charge:-(i) Programmable rated current 1A & 5A, (ii) Last 8 fault record & 200 event record with time stamping, (iii) 4 analog CT & 3 PT input, 8 DI & 8 DO, (iv) Communicable on IEC61850 protocol, (v) Disturbance recording upto 300 cycles, (vi) Self supervision function. The relay shall be fully integrated with the feeder, internally capturing feeder statuses if available including Breaker On, Off, Spring Chrgd, Test, Service, AC-Fail, Trip circuit healthy relay, PT supervision, inter panel tripping, Master trip relay, local remote and display the same locally on a built-in LCD screen and suitably labeled status LEDs. Relay shall have facility to locally Trip/Close the breaker as a backup to TNC switch provided separately on the panel. The relay shall be fixed on new 2mm CRCA sheet of matching existing VCB panel color and suitable size covering all blank space formed by removing old mechanical type IDMT relay complete including associated wiring and integration with existing HT VCB panel complete all as specified and directed.Make :- Crompton Greaves IDMT relay Model No:- CGI-14(S) DC 24Volts/Schneider IDMT relay and Siemens Relay.
2M&L for alternative arrangement by hiring, transportation of transformer of capacity 500 / 630 KVA in place of unserviceable transformer on hire basis for 15 days including, installation, connecting and testing of transformer and return back after installation of repaired transformer complete all as specified and directed by Engr-in-Charge.Notes:-(i) Contractor must arrange hired transformer including transportation and installation at site immediately after receipt of verbal/telephonic/written complaint from JE/Engr-in-Charge within 1 day. Any delay beyond 1 day post receipt of complaint shall be penalized @ Rs 3500/- per day and shall be recovered from next due RAR.(ii) Repairing of transformer must be completed within 15 days after receipt of verbal/ telephonic/ written complaint from JE/Engr-in-Charge. In case of any delay, no extra claim will be entertained towards hiring charges beyond 15 days and the contractor shall not be allowed to shift the hired transformer until replaced by repaired transformer. In case of any kind of fault / defect occurred in hired transformer, the contractor shall have to arrange further replacement without any additional cost and shall repair the defect from his own expenses.(iii) Contractor should check the available infrastructure and to be sure regarding safety of hired transformer before installation. The rate quoted is deemed to be including transportation cost, earthing lead etc.
3M&L for transportation of transformer of capacity upto 630 KVA from MES Yard to site location using Hydra/Crane and truck as per requirement to replace defective transformer including installation, testing and connecting at site and to deposit the same to MES Yard after receipt and installation of repaired transformer at site complete all as specified and directed by Engr-in-Charge.Note:- Contractor must arrange for transportation and installation for replacement of transformer at site immediately after receipt of verbal/telephonic/written complaint from JE/Engr-in-Charge within 1 day. Any delay beyond 1 day post receipt of complaint shall be penalized @ Rs 2500/- per day and shall be recovered from next due RAR.
4Disconnecting electrically and mechanically indoor/outdoor transformers inside the substation or outdoor type on outside plinth upto 630 KVA capacity, carefully for major/minor repairs complete all as specified and directed by Engr-in-Charge.
5Opening the top cover of transformer step down 11 KV to 0.440 KV, of capacity upto 630 KVA of any make, model & type out door/ indoor type, draining out oil, dismantling of cover & taking out damaged coils & fitting new coils, refitting the covers after cleaning/treatment, making all electrical connections providing sundry items & reassembling after repairs to the entire satisfaction of the Engr-in-Charge, testing after repair complete all as specified and directed by Engr-in-Charge. Note: New coils with allied material shall be measured and paid separately. However the rate quoted under Col 6 are inclusive for providing sundry items i.e. bolts, nut & washers etc.Note for Item No 4 & 5 : - In case the defective transformer not repaired & installed at site within the specified period of 15 days from the date of handing over of defective transformer/complaint to contractor, a penalty recovery @ Rs 2500/- per day will be charged from his dues.
6(a) Repairs to the transformer of capacity upto 630 KVA as follows complete all as specified and directed by Engr-in-Charge :-(i) Rewinding of HT/LT leg coil complete using copper wire /strip of appropriate gauge, size and turn as per existing with double paper coated insulation including all requisite insulating materials like packing sleeves, separator, tapes etc. heating, varnishing the core and winding assembly after framing up top and bottom steel structure of transformer all as specified and directed. (ii) Replacement of all insulating materials other than incorporated for rewinding of HT/LT coils as per existing.(iii) Fixing only HT procelain bushing with studs, nuts, washers 3 Nos. and LT procelain bushing with studs, nuts, and washers 4 Nos. and connection with primary and secondary windings and reconnecting with the main terminals as required and directed. (iv) Fixing only breather assembly, conservator, oil temperature gauge after proper cleaning, minor repairs etc. as required and directed.(v) Replacement of all unserviceable gasket from top cover, HT/LT bushing with new one by using rubberised gasket sheet 4.0mm/6.0mm thick duly pasted with suitable adhesive .(vi) Replacement of unserviceable bolts with new one and fixing of existing serviceable bolts, nuts, washers of different sizes and tightening properly.(vii) Repositioning of core and winding assembly inside the tank, assembling complete unit and making the transformer ready for filling oil and subsequent testing as directed. (viii) Filling/topping up of new transformer oil of required quantities .(b) M& L for transportation of repaired transformer to the original position (from where taken-down), disconnecting the alternative transformer, taking down the same, Re-installation of repaired indoor/outdoor transformer on 4/6 pole structure/plinth/inside sub station, connecting electrically and mechanically, testing and commissioning complete all as specified and directed by Engr-in-Charge. Note :-HT/LT leg coils copper wire/strip and transformer oil required shall be measured and paid separately under relevant items of this Schedule here-in-after as supply only.
7Supply only HT coils with super enamelled copper wire /DPC of high quality duly matching with the existing guage and impedance complete all as specified and directed by Engr-in-Charge.
8Supply only LT coils with super enamelled copper wire strip/DPC of high quality duly matching with the existing guage and impedance complete all as specified and directed by Engr-in-Charge.
9M&L for ON load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer installed at various site on plinth/4/6 pole structure of any capacity and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed by Engr-in-Charge.Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under item No 10 here-in -after as supply only.
10Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in transformer or for topping up as required and directed complete all as specified and directed by Engr-in-Charge.
11Supplying and fixing in replacement, Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 630 KVA and re-connecting electrically and mechanically, testing complete all as specified and directed by Engr-in-Charge.Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers and provision of pad type bus bar almuminium of approppiate size /capacities of transformers with nut bolt & washers.
12Supplying and fixing in replacement, Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 630 KVA and connecting electrically and mechanically, testing complete all as specified and directed by Engr-in-Charge.Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers and connections.
13Supplying and fixing in replacement, all unserviceable gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 630 KVA and re-connecting electrically and mechanically, testing complete all as specified and directed by Engr-in-Charge.Note. The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers etc.
14Supplying and fixing in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers, capacity upto 630 KVA complete all as specified and directed by Engr-in-Charge.
15Supply and fixing Thermometer of transformer upto capacity 630 KVA complete all as specified and directed by Engr-in-Charge.
16Material & Labour for painting of transformer installed on plinth/4/6 pole structures at various site of capacity 100 TO 630 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and directed by Engr-in-Charge.
17S&F in replacement MS angle iron, flat,Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-Charge.
18S&F in replacement 3.15mm dia MS wire 75x75mm mesh , made up into mattress or cages appx 2.00 mtr height and fixed with flate iron /angle by welding in position complete all as specified and directed by Engr-in-Charge.
19Supply and filling in replacement silica gel in breather of transformer complete all as specified and directed by Engr-in-Charge.
20M&L in replacement 32x6mm galvanised iron strip for earth continuity conductor for earthing of transformer , GOD , 4/6 pole , structure etc complete all as specified and directed by Engr-in-Charge.
21Material and labour for servicing /testing of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 1250 /800/630 Amps and rating 11 KV complete all as specified and directed by Engr-in-Charge:-(a) Details of servicing of breaker :-(i) Adjustment of mechanism if required.(ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth.(iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts.(iv) Check for rust and wear.(v) Check Spring Tension and pitting of the Cluster Contacts.(vi) Visual check for rust and deformation.(vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc.(viii) Check for loosened connections, rust, damaged lead wires.(ix) Check whether the contacts are damaged by arcing.(x) Checking of control circuit & tighten the connections if any.(xi) Check close & trip coil.(xii) Checking of Jaw Contacts Conditions and repair/adjust.(xiii) Replace the jaw contacts,If required.(xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish.(xv) Replacement of Dashpot/shock absorbers .(xvi) Replacement of carbon brush of spring charging motor(b) The following test shall be carried out :-(i) Primary Injection Test of CT / PT(ii) Closing & Opening Timing Test for all three poles.(iii) IR Test with megger in open and closed condition.(iv) Contact resistance test for all three poles(v) Closing coil resistance (vi) Tripping coil resistance.(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :-(i) Over current and earth fault relay(d) Testing of followig Aux relay(i) DC Supply supervision relay. (ii) Master trip relay
22Supplying ,fixing & testing in replacement master trip relay , 50/24 Volt DC in control panel including wiring complete all as specified and directed by Engr-in-Charge.
23Supplying ,fixing & testing in replacement Trip circuit supervision relay , 50/24 Volt DC in control panel including wiring complete all as specified and directed by Engr-in-Charge.
24Supplying ,fixing , testing of SF 6 gas pressure supervision relay , 50/24 Volt DC in control panel including wiring complete all as specified and directed by Engr-in-Charge.
25Supply installation & commissioning in replacement of 24V/40A Float Cum Boost Battery Charger unit including battery bank comprising 02 Nos of 12 Volts-100 AH sealed maintenance free battery. The CCCV battery charger consisting of copper wound, air cooled transformer, 01 Set single phase full wave bridge rectifier consisting of diodes and SCRs, liberally rated mounted on heat sink and complete with resistor/condenser network for surge supperssion . During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DC digital ammeter , DC digital voltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom . The battery charger shall be divided into two compartments. The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1(c) On load input power factor - > 0.8(d) On load unit watt efficiencies-> 80% (e) No load losses of complete charge-< 10% (f) Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell .(j) Float charging -2.15 V/Cell(k) Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode.(l) Reverse polarity -No damage will caused . A visual indication for reverse polarity will appear with an audio alarm.(m) Short circuit-MCB protecton provided.
26Material and labour for Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of synthetic enamel paint by spray machine on all sides of 11 KV VCB panel including writing of MES /SM No and details of feeder as directed by Engr-in-charge on graphic plastic sheet complete all as specified and directed by Engr-in-Charge.
27Disconnecting HT supply from 11 KV , 630 Amps RMU , 5/4 way and servicing and overhauling of RMU , checking of tripping mechanism , greasing of moving contacts , cleaning of carbon from main contacts , checking of spring tension ,Checking of loosened bolts and nuts, checking of loosened connections, rust, damaged lead wires, checking of spring charging motor , Improvement of resistance of CTs , PT, epoxy insulator and epoxy body by applying post heated varnish complete all as specified and directed by Engr-in-Charge:-
28Material and labour for checking the existing pressure of SF6 Gas in Gas Chamber of 11 KV , 630 Amps RMU , 5/4 way before filling and topping up the SF6 gas in the chamber of RMU including supervision of gas filling/topping up process and checking the pressure of gas after filling complete all as specified and directed by Engr-in-Charge.
29Supplying and fixing in replacement operating mechanism (2PA Mechanism W/O hex Rod) for 11 KV , 630 Amps RMU , 5/4 way complete all as specified and directed by Engr-in-Charge.
30Supply and fixing in replacement cable Boots 11 KV , in 630 Amps RMU , 5/4 way complete all as specified and directed by Engr-in-Charge.
31Supplying and fixing in replacement associated ring-core cast-resin insulated CTs 100/50/1 -1 Amp , 2.5 VA, 10P10 for protection in 11 KV, 630 Amps RMU complete all as specified and directed by Engr-in-Charge.
32Supplying and fixing in replacement associated ring-core cast-resin insulated CTs 60/30/1-1Amp , 2.5 VA, 10P10 for protection in 11 KV, 630 Amps RMU complete all as specified and directed by Engr-in-Charge.
33Supplying and fixing in replacement 1-Ph (11kV/rt3):110 VAC, 50VA Potential transformer in 11 KV, 630 Amps RMU (Ring main unit) complete all as specified and directed by Engr-in-Charge.
34Supplying and fixing in replacement 1-Ph (11kV/rt3):110VAC, 500VA Auxiliary transformer in 11 KV, 630 Amps RMU (Ring main unit) complete all as specified and directed by Engr-in-Charge.
35Suplying and laying as replacement in sub station fixing 3.3 to 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification as per IS 15652 2006 complete all as specified and directed by Engr-in-Charge:-
36Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
3795 Sqmm to 185 Sqmm, 3 core.
38240 Sqmm to 300 Sqmm, 3 core.
39Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size complete all as specified and directed by Engr-in-Charge:-
4095 Sqmm to 185 Sqmm, 3 core.
41240 Sqmm to 300 Sqmm, 3 core.
42Supplying, installation, commissioning and testing of 11 KV Current Transformer (CT`s), indoor type, resin cast epoxy type, of 13.1 KA/Sec having ratio 400/200/5-5 Amps having Core1: Class 5P10, 10VA for protection , Core2: Class 0.5, 10VA for metering and associated wiring including taking down old UNSV CTs complete all as specified and directed by Engr-in-Charge.
43All as per item No 38 here-in-before but having ratio 200/100/5-5 complete all as specified and directed by Engr-in-Charge.
44All as per item No 38 here-in-before but having ratio 150/75/5-5 complete all as specified and directed by Engr-in-Charge.
45All as per item No 38 here-in-before but having ratio 100/50/5-5 complete all as specified and directed by Engr-in-Charge.
46Supplying and fixing Potential Transformers, Draw-out type in existing HV panel for easy maintenance, 11kV/rt3:110V/rt3, 50VA, Cl.0.5 with associated gun-type HRC fuses and MCBs for HT/LT isolation including taking down old UNSV PTs complete all as specified and directed by Engr-in-Charge.
47Supplying, installation, commissioning and testing of PT unit three phase, three limbs, upto 11 KV draw-out type, resin cast dry type, single ratio having primary voltage 11 KV & secondary voltage 110 volts, 50 VA class-1 including necessary bus bar connections & wiring for metering including taking down old UNSV PTs cocomplete all as specified and directed by Engr-in-Charge.
48S&F LED indication lamp for breaker ON/OFF/TRIP/Breaker Spring Charged/R-Y-B etc for 11 KV control panel and associated wiring, if reqd, including taking down old UNSV LED indication complete all as specified and directed by Engr-in-Charge.
49Supply and installation Anti-condensation space-heater withThermostatic control in cable and circuit breaker compartments of HT switchgears including taking down old UNSV heater complete all as specified and directed by Engr-in-Charge.
50S&F of vacuum interrupter suitable for 400/630/800 amps, 11 KV HT VCB including taking down old UNSV vacuum interrupter complete all as specified and directed by Engr-in-Charge:-
51S&F of isolating contact assembly suitable for 400/630/800 amps, 11 KV HT VCB including taking down old UNSV contact assembly complete all as specified and directed by Engr-in-Charge.
52S&F of fixed contact block complete suitable for 400/630/800 amps, 11 KV HT VCB including taking down old UNSV contact block complete all as specified and directed by Engr-in-Charge.
53S&F of moving contact block complete suitable for 400/630/800 amps, 11 KV HT VCB including taking down old UNSV moving contact block complete all as specified and directed by Engr-in-Charge.
54S&F of motor & gear assembly 230V AC suitable for 400/630/800 amps, 11 KV HT VCB, testing & puting on load including taking down old UNSV motoer gear assembly complete all as specified and directed by Engr-in-Charge.
55S&F of spring gear suitable for 400/630/800 amps, 11 KV HT VCB including taking down old UNSV spring bearing gear complete all as specified and directed by Engr-in-Charge.
56S&F of closing coil assembly 24 volts DC suitable for 400/630/800 amps, 11 KV HT VCB including taking down old UNSV closing coil complete all as specified and directed by Engr-in-Charge.
57S&F of tripping coil assembly 24 volts DC suitable for 400/630/800 amps, 11 KV HT VCB including taking down old UNSV tripping coil complete all as specified and directed by Engr-in-Charge.
58Supply and fix close/trip coil 24V DC for 11 KV HT VCB of capacity 400/630/800 Amps capacity including taking down old UNSV close/trip coil complete all as specified and directed by Engr-in-Charge.
59S&F of panel door lock suitable for 400/630/800 amps, 11 KV HT VCB including taking down old UNSV panel ddor lock complete all as specified and directed by Engr-in-Charge.
60Supplying & Fixing auxillary switch (7 No + 7NC) suitable for 400/630/800 amps, 11 KV HT VCB including taking down old UNSV auxillary contact complete all as specified and directed by Engr-in-Charge.
61Supply and fix T&C Switch for Breaker ON/OFF purpose in HT 11 KV VCB panel including associated wiring, if reqd, for proper functioning of switch including taking down old UNSV T& C switch complete all as specified and directed by Engr-in-Charge.
62S&F of Digital Ammeter (CT secondary site selectable 5A) for 11 KV VCB Control Panel including taking down old UNSV meter complete all as specified and directed by Engr-in-Charge.
63S&F of Digital Volt meter Secondary voltage 110 V for 11 KV VCB Control Panel including taking down old UNSV meter complete all as specified and directed by Engr-in-Charge.
64S&F and installation battery 12 volts,100 AH, dry type in replacement of old unserviceable battery in battery charger with suitable size of new copper battery terminal and lugs and initialy charging, commissioning and testing complete including taking down old UNSV battery complete all as specified and directed by Engr-in-Charge.
65S&F and installation battery 12 volts, 26 AH, dry type in replacement of old unserviceable battery in battery charger with suitable size of new copper battery terminal and lugs and initialy charging, commissioning and testing complete including taking down old UNSV battery complete all as specified and directed by Engr-in-Charge.
66Supply and fixing in replacement of Electronic Trivector meter, 3 phase 4 wire suitable for 11 KV VCB HT Panel complete all as specified and directed by Engr-in-Charge.
67Supply, installation, testing, and commissioning in replacement of an existing unit, a 3-Phase, 4-Wire Electronic Trivector Meter (TVM). The meter must be completely suitable for operation on a 1.1 kV LT (Low Tension) Switchgear Panel. The scope includes all necessary mounting accessories, control wiring connections, programming, and calibration as specified and directed by the Engineer-in-Charge. System Compatibility: 3-Phase, 4-Wire, LT System 1.1kV insulation grade)Approved Makes: L&T / Secure Meters / Schneider Electric
68Removing the waste building materials at our substation, such as rock, sand, bricks, tiles and mud need to be loaded onto a vehicle and disposed of at a location outside.Its the contractor responsibility to arrange for the disposal site etc complete all as specified and directed by Engr-in-Charge.
69Material and labour for spreading if stone aggregate of normal size not more than 25mm under 4/6 pole HT structure/surrounding area of outdoor RMU manually without damaging any equipments , cable or parts , spreading & levelling of finished gravel uniformly in layers n. exc. 15cm thick watered and rammed to true surface all as specified and directed complete all as specified and directed by Engr-in-Charge.
70Material and Labour only for Applying two coats of synthetic enamel paint over steel,wire mesh and iron surfaces old painted surfaces of any description and clamps, bolts above GL exceeding 10cm width or girth complete all as specified and directed by Engr-in-Charge.
71M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engr-in-Charge.
72Supply and fixing LED lights fitting 1x 40W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
73M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregates) as in floors or paving 50mm thick and finished even and fair with out using extra cement complete all as specified and directed by Engr-in-Charge.
74M&L for Preparation of new/old plastered surfaces and applying two coats of cement base paint including priming surface with chalk whiting complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information
75M&L for Preparation of new/old plastered surfaces and applying two coats of cement base paint including priming surface with chalk whiting complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58115525
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 07-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Transformers, Vcb, Rmu, Battery Charger, Relay And Connected Items At Cassel Road Sub Stn, Urban Village, Mall Road, Polo Road, Church Road, Tigris Road, Did Line, 19Haa, Station Road, Mandir Marg, Maude Road, 4 No P/F, Harbaksh Stadium, Tubarak Lines, 972 Tpt Coy, Mech C And Adjoining Area Of Age Elect Supply Sldc Under Ge (U) Elect Supply Delhi Cantt-10
Basic Detail
Tender No GE ELECT/TOKEN-59/2026-2027
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 17 Oct 2026
Submission Date 07 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Not Available
Document List
BOQ_891270.xls
f9776fb1-ea13-4c9c-81e1-a0e253db038a.html
TD59.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.