Tender For Repair And Maintenance Of Various Capacity Of Ro Plant, Oil Heater, Fire Hydrant System Installed At Comd Hosp (Wc) Under Age E/M (Ch) Of Ge (U) Chm
Tender Value
20 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
10 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Various Capacity Of Ro Plant, Oil Heater, Fire Hydrant System Installed At Comd Hosp (Wc) Under Age E/M (Ch) Of Ge (U) Chm
BOQ
| Sl. No. | Item Description |
| 1 | Servicing & repair/replacement of defective/unserviceable parts of RO Plant having capacity 60 litres per Hrs including testing of the RO plant for entire satisfaction of Engr-in-Charge.Note:(a) The Contractor will be responsible for continuous serviceability of each RO during the contract period.(b) Unserviceable parts shall be measured and paid separately under the respective items as supply only |
| 2 | Supply only Spun/ paper filter 20\\". Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 3 | Supply only Carbon filters 20\\". Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 4 | Supply only Membrane complete assembly 40/80 flow rate 20\\".Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 5 | Supply only Superior quality RO connection pipe of size 3/4\\" dia including all connected fittings |
| 6 | Supply only Booster pump motor 0.5 HP , single phase, 230 volts suitable for 60 LPH RO. |
| 7 | Supply only solenoid valve for 60 LPH RO. |
| 8 | Supply only Primary filter housing complete body with candle , elbow & top cover 20\\" complete all as specified and directed. Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 9 | Supply only Carbon filter housing complete body with candle , elbow & top cover 20\\". Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 10 | Supply only Membrane Housing with membrane suitable for 60 LPH RO.Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 11 | Supply only Stainless steel fabricated of grade SS 304 stand for 60 LPH RO. |
| 12 | Supply only flow resistance (FR) suitable for 60 LPH RO. |
| 13 | Supply only TDS adjustor suitable for 60 LPH RO |
| 14 | Supply only flow valve suitable for 60 LPH RO |
| 15 | Supply only SMPS DC output power supply 5 Amp, 24/36 Volts. |
| 16 | Supply only high pressure switch suitable for 60 LPH RO |
| 17 | Supply only low pressure switch suitable for 60 LPH RO. |
| 18 | Supply only Apec aqua plastic RO direct inlet quick valve straight connector 1/2\\" for female thread and 1/4\\" push fit for RO water purifiers suitable for 60 LPH RO. |
| 19 | Supply only water cooler 20/25 mm tap connector with female brass inserT 15x30x50 suitable for 60 LPH RO. |
| 20 | Servicing & repair/replacement of defective/unserviceable parts of RO Plant having capacity 25 litres per Hrs including testing of the RO plant for entire satisfaction of Engr-in-Charge.Note:(a) The Contractor will be responsible for continuous serviceability of each RO during the contract period.(b) Unserviceable parts shall be measured and paid separately under the respective items as supply only. |
| 21 | Supply only Spun filter 10\\" Make: Polyline, Ion Exchange, Aquafresh, Livpure, Kent |
| 22 | Supply only Carbon filters 10\\" Make: Polyline, Ion Exchange, Aquafresh, Livpure, Kent |
| 23 | Supply only Membrane complete assembly 100 GPD Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 24 | Supply only Booster pump 300 GPD, single phase, 230 phase. |
| 25 | Supply only RO solenoid valve for 25 Ltrs plant 24 VDC. |
| 26 | Supply only Primary filter complete body with candle , elbow & top cover 10\\" complete all as specified and directed. Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 27 | Supply only Stainless steel stand fabricated of grade SS 304 for 25 LPH RO. |
| 28 | Supply only Carbon filter housing complete body with candle , elbow & top cover 10\\", Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 29 | Supply only Membrane Housing with membrane suitable for 25 LPH RO.Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 30 | Supply only SMPS DC output power supply 2.5 Amp, 24/36 Volts. |
| 31 | Supply only Superior quality RO connection pipe of size 1/4\\" dia including all connected fittings |
| 32 | Supply only flow resistance (FR) suitable for 25 LPH RO. |
| 33 | Supply only TDS Adjustor suitable for 25 LPH RO. |
| 34 | Supply only flow valve suitable for 25 LPH RO |
| 35 | Supply only high pressure switch suitable for 25 LPH RO |
| 36 | Supply only low pressure switch suitable for 25 LPH RO |
| 37 | Supply only Apec aqua plastic RO direct inlet quick valve straight connector 1/2\\" for female thread and 1/4\\" push fit for RO water purifiers suitable for 25 LPH RO. |
| 38 | Supply only water cooler 15/20 mm tap connector with female brass insert 15x30x50 suitable for 25 LPH RO |
| 39 | Servicing & repair/replacement of defective/unserviceable parts of RO Plant having capacity 100 litres per Hrs including testing of the RO plant for entire satisfaction of Engr-in-Charge.Note:(a) The Contractor will be responsible for continuous serviceability of each RO during the contract period.(b) Unserviceable parts shall be measured and paid separately under the respective items as supply only. |
| 40 | Supply only Spun filter suitable for 100 Ltrs RO Make: Polyline, Ion Exchange, Aquafresh, Livpure, Kent |
| 41 | Supply only Carbon filters suitable for 100 Ltrs RO Make: Polyline, Ion Exchange, Aquafresh, Livpure, Kent |
| 42 | Supply only Membrane complete assembly suitable for 100 Ltrs RO Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 43 | Supply only Booster pump suitable for 100 Ltrs RO, single phase, 230 phase. |
| 44 | Supply only RO solenoid valve for suitable for 100 Ltrs RO plant 24 VDC. |
| 45 | Supply only Primary filter complete body with candle , elbow & top cover suitable for 100 Ltrs RO complete all as specified and directed. Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 46 | Supply only Membrane Housing with membrane suitable for 100 LPH RO.Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 47 | Supply only SMPS DC output power supply suitable for 100 LPH RO, 24/36 Volts. |
| 48 | Supply only Superior quality RO connection pipe of size 1/4\\" dia including all connected fittings |
| 49 | Supply only flow resistance (FR) suitable for 100 LPH RO. |
| 50 | Supply only TDS Adjustor suitable for 100 LPH RO. |
| 51 | Supply only flow valve suitable for 100 LPH RO |
| 52 | Supply only high pressure switch suitable for 100 LPH RO. |
| 53 | Supply only low pressure switch suitable for 100 LPH RO. |
| 54 | Supply only Apec aqua plastic RO direct inlet quick valve straight connector 1/2\\" for female thread and 1/4\\" push fit for RO water purifiers suitable for 100 LPH RO. |
| 55 | Supply only water cooler 15/20 mm tap connector with female brass insert 15x30x50 suitable for 100 LPH RO |
| 56 | Servicing & repair/replacement of defective/unserviceable parts of RO Plant having capacity 220 LPH, Trolly mounted of capacity per Hrs including testing of the RO plant for entire satisfaction of Engr-in-Charge.Note:(a) The Contractor will be responsible for continuous serviceability of each RO during the contract period.(b) Unserviceable parts shall be measured and paid separately under the respective items as supply only. |
| 57 | Supply only sand Media as per sample as specified and directed |
| 58 | Supply only carbon Media as per sample |
| 59 | Supply only Chemical (Resin and sodium chloride) |
| 60 | Supply only cartridge filter as per sample Make - Ion Exchange, Aquafresh, Livpure, Kent |
| 61 | Supply only TDS adjustor for 220 LPH RO plant as per sample. |
| 62 | Supply only motor pump 0.5 HP as per sample |
| 63 | Supply only high pressure pump of size 2 HP suitable for 220 LPH RO plant as per sample |
| 64 | Supply only multi pot valve as per sample |
| 65 | Supply only pressure pump seal as per sample |
| 66 | Supply only display for 220 LPH RO plant as per sample |
| 67 | S&F as in replacement PVC insulated flexible copper conductor cable 1.5 Sqmm 3 core, 1100 Volts grade conforming to IS 694 (FRLSH) complete all as specified and as directed by the Engr-in-Charge. |
| 68 | S &F as in replacement PVC insulated flexible copper conductor cable 1.0 Sqmm 3 core, 1100 Volts grade conforming to IS 694 (FRLS) complete all as specified and as directed by the Engr-in-Charge |
| 69 | S&F as in replacement Plug top 5 Amp, 3 pin including making electrical connection with existing cable complete all as specified and directed. |
| 70 | Supply, laying & fixing in wall, floor and ceiling CPVC Pipe 20 mm dia medium grade with all fitting and including cutting chases of wall and making good all disturbed surfaces as per existing with wall putty and distemper complete all as specified and directed by Engr-in-Charge |
| 71 | Supply, laying & fixing in wall, floor and ceiling CPVC Pipe 25 mm dia medium grade with all fitting and including cutting chases of wall and making good all disturbed surfaces as per existing with wall putty and distemper complete all as specified and directed by Engr-in-Charge. |
| 72 | Supply, laying & fixing in wall, floor and ceiling CPVC Pipe 32 mm dia medium grade with all fitting and including wall cutting of wall and making good all disturbed surfaces as per existing with wall putty and distemper complete all as specified and directed by Engr-in-Charge. |
| 73 | Supply & fixing in replacement of CPVC /PPR gate/ ball valve of size 20 mm dia suitable for existing RO pipe line complete all as specified and directed. |
| 74 | Supply & fixing in replacement of CPVC/ PPR gate/ ball valve of size 25 mm dia suitable for existing RO pipe line complete all as specified and directed. |
| 75 | Supply & fixing in replacement of CPVC/ PPR gate valve of size 32 mm dia suitable for existing RO pipe line complete all as specified and directed. |
| 76 | Material and labour in replacement for Sub main wiring with 2 run of 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC concealed conduit with and including 1.5 Sqmm (nominal area) FR, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified & directed |
| 77 | Supply and fix switch modular 6 Amps , one way, 230 volts, 1 Module complete all as specified & directed . |
| 78 | Supply and fix socket modular 6 Amps , one way, 2/3 pin, 230 volts. , 2 Module complete all as specified & directed. |
| 79 | Supply and fix modular white cover plate with frame 3 Module complete all as specified & directed. |
| 80 | Supply and fix modular metal flush box 3 Module complete all as specified & directed. |
| 81 | Servicing of water cooler of capacity 40 to 80 liters with washing chemical and warm water and replacing defective minor parts such as nut & bolts, PVC pipes and connected items complete all as directed by Engr-in-Charge. |
| 82 | Supply & fixing as in repairs fan motor, Single phase, 230 Volts complete all as directed by Engr-in-Charge |
| 83 | Supply & fixing as in repairs thermostat, AC single phase, 230 Volts complete all as directed by Engr-in-Charge |
| 84 | Supply & fixing as in repairs Self-closing taps, 15 mm bore brass chromium plated complete all as directed by Engr-in-Charge. |
| 85 | Supply & fixing as in repairs Fan Blade steel as per existing size complete all as directed by Engr-in-Charge. |
| 86 | Supply & fixing as in repairs brass ball valve 25 mm size complete all as directed by Engr-in-Charge. |
| 87 | Supply & fixing as in repairs float valve as per existing size complete all as directed by Engr-in-Charge |
| 88 | Servicing of Oil filled room heater with checking of power connections and repairing defective fins, replacing of control switches complete all as directed by Engr-in-Charge |
| 89 | Supply & fixing as in repairs heating element of cap 1.5 KW of oil filled room heater complete all as directed by Engr-in-Charge |
| 90 | Supply & fixing as in repairs thermostat, AC single phase, 230 Volts of oil filled room heater complete all as directed by Engr-in-Charge. |
| 91 | Supply & fixing as in repairs of castor wheels for portability of oil filled room heater complete all as directed by Engr-in-Charge. |
| 92 | Taking up and refixing of power card after repairing of oil filled room heater complete all as directed by Engr-in-Charge. |
| 93 | Excavation in trenches in hard/dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of pipes in trenches and getting out including leveling of bottom surface and trimming of sides complete all as specified and directed |
| 94 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick each as in soft/loose soil, complete all as specified and directed |
| 95 | Removing of surplus soil / excavated material to a distance not exceeding 50 metre and depositing where directed complete all as specified. |
| 96 | Supply and fixing as in repairs Hydrant landing valve type A (ISI marked) with single head outlet of 63mm dia conforming to IS 5290 complete all as specified and directed |
| 97 | Supply and fixing in repair branch pipe stainless steel 63 mm instantaneous inlet, made with thread outlet 15mm bore nozzle, conforming to IS 903, complete all as specified and directed. |
| 98 | Supply and fixing in repair RRL hose type A 15 Mtr long conforming to IS-636 with male and female coupling complete all as specified and directed. |
| 99 | Supply and fixing in repair hose reel 20 mm dia and 30 meter long with SS jet nozzle conforming to IS-8132 complete all as specified and directed. Please Enable Macros to View BoQ information |
| 100 | Supply and fixing in repair hose reel 20 mm dia and 30 meter long with SS jet nozzle conforming to IS-8132 complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender