Tender For Special Repairs Of Building No P-139 (Chenab) And Allied Services At Nausena Baugh, Visakhapatnam
Tender Value
7.49 Crore
Estimated cost
Bid Submission
17 Nov 2026
19 days left
EMD
6.99 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs Of Building No P-139 (Chenab) And Allied Services At Nausena Baugh, Visakhapatnam
BOQ
| Sl. No. | Item Description |
| 1 | Removal existing treatment any type, any thickness and roughening the surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc., brushing neat cement slurry with 3 Kg., of cement per square metre, laying 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded aggregate ) laid on RCC slab to make surface levelled for proper slope finished even and fair, rendering 10 mm thick in CM 1:4 on concrete srfaces to make surface smooth to receive water proof treatment including mixing WPC as per manufacturing instructions, Supply and lay hyperlas standard 3 Kg/Sqm polymeric water proofing membrane incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100 gms/sqm followed by a coat of blown bitumen of grade 85/25 or 90 /15 @ 1.2 Kg/Sqm each at top and bottom of the membrane followed by a coat of bituminous aluminium primer @ 100 gms/Sqm complete including sealing all joints by thermo fusion with minium 10 cm overlap all as per manufacturer's instructions, M&L for cool roof tiles of size 300 x 300 x 7mm thick & SRI value more than 90 as on roof laid over screed bed over bedding layer of mortor 10mm thick in cement mortor 1:4 joint shall be kept as 3mm filled with epoxy grout and masking tape shall be put before putting the epoxy grout , grout shall be througly cleaned immediatlely complete all as specified and directed from 13th Storey to 16th Storey complete all as specified and as directed.Note : The colour / shade / design of tile shall be as approved by GE |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thickness complete all as specified and as directed. |
| 3 | Demolition of un-reinforced Cement Concrete including tiles of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 4 | All as per above item No. 3 but from 5th Storey to 8th Storey |
| 5 | All as per above item No. 3 but from 9th Storey to 12th Storey |
| 6 | All as per above item No. 3 but from 13th Storey to 16th Storey |
| 7 | M&L for 25 mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) as in sub base of floors complete all as specified and as directed. |
| 8 | All as per above item No.7 but from 5th Storey to 8th Storey |
| 9 | All as per above item No.7 but from 9th Storey to 12th Storey |
| 10 | All as per above item No.7 but from 13th Storey to 16th Storey |
| 11 | M&L for Non-skid coloured ceramic joint free tiles in light shade 7 to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tile over and including screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes complete all as specified and as directed. |
| 12 | All as per above item No. 11 but from 5th Storey to 8th Storey |
| 13 | All as per above item No. 11 but from 9th Storey to 12th Storey |
| 14 | All as per above item No. 11 but from 13th Storey to 16th Storey |
| 15 | M&L for coloured Non skid ceramic tiles 7 to 8 mm thick (Square / rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including screed bed 15 mm thick in CM(1:6) including dismantling of floor, hearth or wall tiling complete all as specified and as directed. |
| 16 | All as per above item No. 15 but from 5th Storey to 8th Storey |
| 17 | All as per above item No. 15 but from 9th Storey to 12th Storey |
| 18 | All as per above item No. 15 but from 13th Storey to 16th Storey |
| 19 | M&L for Coloured Non Skid ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.18 Sq. M but not exceeding 0.36 Sq. M, as in Skirtings etc., set ,over 10 mm thick backing coat in CM(1:3) and jointed in neat cement slurry and pointed in white or Coloured cement to match complete all as specified and as directed. |
| 20 | All as per above item No. 19 but from 5th Storey to 8th Storey |
| 21 | All as per above item No. 19 but from 9th Storey to 12th Storey |
| 22 | All as per above item No. 19 but from 13th Storey to 16th Storey |
| 23 | M&L for Coloured Glazed ceramic tiles area of each tile 450 x 300 x 7 mm thick, on vertical surfaces such as , dados and risers to steps etc.,over 10mm thick backing coat CM 1:3 set and jointed in neat cement slurry and pointed in white or Coloured cement to match complete all as specified and as directed. |
| 24 | All as per above item No. 23 but from 5th Storey to 8th Storey |
| 25 | All as per above item No. 23 but from 9th Storey to 12th Storey |
| 26 | All as per above item No. 23 but from 13th Storey to 16th Storey |
| 27 | M&L for Plain Cement Concrete Type E2 1:5:10 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 28 | All as per above item No. 27 but from 5th Storey to 8th Storey |
| 29 | All as per above item No. 27 but from 9th Storey to 12th Storey |
| 30 | All as per above item No. 27 but from 13th Storey to 16th Storey |
| 31 | M&L for rendering 10 mm thick on brick work or concrete surfaces in cement mortar 1: 4 mixed with WPC and finishing the surface even and smooth without using extra cement upto 04th storey complete all as specified and directed.NOTE: Water proofing compound shall be measured and paid separately under relevant item as supply only. |
| 32 | All as per above item No. 31 but from 5th Storey to 8th Storey |
| 33 | All as per above item No. 31 but from 9th Storey to 12th Storey |
| 34 | All as per above item No. 31 but from 13th Storey to 16th Storey |
| 35 | M&L for applying Chemical Injection Treatment in the form of Pressure Grouting by drilling 20 mm dia holes, 60 mm deep @ 100 cm grid at at junction of bottom floor and all the internal wall surfaces of the sunken slabs of toilet by injecting Cement Slurry mixed with Grout Admixture \\"CONBEXTRA EP 10\\" of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Batik India Pvt. Ltd. at 225 Grams for 50 KG of cement and applying a coat of Brush Bond RFX of M/s. Fosroc Chemicals or equivalent approved water proofing coating as per manufacturer's instructions complete all as required and as directed at site. |
| 36 | All as per above item No. 35 but from 5th Storey to 8th Storey |
| 37 | All as per above item No. 35 but from 9th Storey to 12th Storey |
| 38 | All as per above item No. 35 but from 13th Storey to 16th Storey |
| 39 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 40 | All as per above item No. 39 but from 5th Storey to 8th Storey |
| 41 | All as per above item No. 39 but from 9th Storey to 12th Storey |
| 42 | All as per above item No. 39 but from 13th Storey to 16th Storey |
| 43 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for and disposal off unserviceable materials, debris and rubbish outside MD Land complete all as specified and directed. |
| 44 | All as per above item No. 43 but from 5th Storey to 8th Storey |
| 45 | All as per above item No. 43 but from 9th Storey to 12th Storey |
| 46 | All as per above item No. 43 but from 13th Storey to 16th Storey |
| 47 | M&L for Reinforced Cement Concrete (Nominal Mix) Type B1 1:2:4 (using 20 mm graded stone aggregate) for slabs suspended on walls, beams and columns, in floors, roofs, landings and in shelves and the like complete all as specified and as directed. |
| 48 | All as per above item No. 47 but from 5th Storey to 8th Storey |
| 49 | All as per above item No. 47 but from 9th Storey to 12th Storey |
| 50 | All as per above item No. 47 but from 13th Storey to 16th Storey |
| 51 | M&L for Reinforced Cement Concrete (Nominal Mix) Type A1 1:11/2:3 (using 20 mm graded stone aggregate) for shelves and the like complete all as specified and directed. |
| 52 | All as per above item No. 51 but from 5th Storey to 8th Storey |
| 53 | All as per above item No. 51 but from 9th Storey to 12th Storey |
| 54 | All as per above item No. 51 but from 13th Storey to 16th Storey |
| 55 | Use and waste of form work fair finished flat steel form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200 mm thick complete all as specified and directed. |
| 56 | All as per above item No. 55 but from 5th Storey to 8th Storey |
| 57 | All as per above item No. 55 but from 9th Storey to 12th Storey |
| 58 | All as per above item No. 55 but from 13th Storey to 16th Storey |
| 59 | Use and waste of form work fair finished flat steel form work to sides and soffits of shelves including supports etc complete all as specified and directed. |
| 60 | All as per above item No. 59 but from 5th Storey to 8th Storey |
| 61 | All as per above item No. 59 but from 9th Storey to 12th Storey |
| 62 | All as per above item No. 59 but from 13th Storey to 16th Storey |
| 63 | M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 64 | All as per above item No. 63 but from 5th Storey to 8th Storey |
| 65 | All as per above item No. 63 but from 9th Storey to 12th Storey |
| 66 | All as per above item No. 63 but from 13th Storey to 16th Storey |
| 67 | M&L for Mild steel TMT round bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 68 | All as per above item No. 67 but from 5th Storey to 8th Storey |
| 69 | All as per above item No. 67 but from 9th Storey to 12th Storey |
| 70 | All as per above item No. 67 but from 13th Storey to 16th Storey |
| 71 | Demolition of brick work built in cement mortar including all quoins, pillars etc complete all as specified and as directed. |
| 72 | All as per above item No. 71 but from 5th Storey to 8th Storey |
| 73 | All as per above item No. 71 but from 9th Storey to 12th Storey |
| 74 | All as per above item No. 71 but from 13th Storey to 16th Storey |
| 75 | M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 up to 4th storey complete all as specified and directed. |
| 76 | All as per above item No. 75 but from 5th Storey to 8th Storey |
| 77 | All as per above item No. 75 but from 9th Storey to 12th Storey |
| 78 | All as per above item No. 75 but from 13th Storey to 16th Storey |
| 79 | M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed upto 4th storey |
| 80 | All as per above item No. 79 but from 5th Storey to 8th Storey |
| 81 | All as per above item No. 79 but from 9th Storey to 12th Storey |
| 82 | All as per above item No. 79 but from 13th Storey to 16th Storey |
| 83 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, where directed and leaving the work clear of any plastering complete all as specified and directed. |
| 84 | All as per above item No. 83 but from 5th Storey to 8th Storey |
| 85 | All as per above item No. 83 but from 9th Storey to 12th Storey |
| 86 | All as per above item No. 83 but from 13th Storey to 16th Storey |
| 87 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished even and smooth withut using extra cement complete all as specified and directed. |
| 88 | All as per above item No. 87 but from 5th Storey to 8th Storey |
| 89 | All as per above item No. 87 but from 9th Storey to 12th Storey |
| 90 | All as per above item No. 87 but from 13th Storey to 16th Storey |
| 91 | M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and 5mm thick in CM 1:4 mixed with WPC and finished fair and even without using extra cement complete all as specified and directed. NOTE: Water proofing compound shall be measured and paid separately under relevant item as supply only. |
| 92 | All as per above item No. 91 but from 5th Storey to 8th Storey |
| 93 | All as per above item No. 91 but from 9th Storey to 12th Storey |
| 94 | All as per above item No. 91 but from 13th Storey to 16th Storey |
| 95 | M&L for Rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and finished fair and even without using extra cement complete all as specified and directed. |
| 96 | All as per above item No. 95 but from 5th Storey to 8th Storey |
| 97 | All as per above item No. 95 but from 9th Storey to 12th Storey |
| 98 | All as per above item No. 95 but from 13th Storey to 16th Storey |
| 99 | S&F stainless steel sink with drainage board over all size of 915mm x 460 mm, bowl size 410 x 330 x 160 mm with plugs washers and waste coupling upto 16th storey including necessary supporting brackets complete all as specified and directed. |
| 100 | All as per above item No. 99 but from 5th Storey to 8th Storey |
| 101 | All as per above item No. 99 but from 9th Storey to 12th Storey |
| 102 | All as per above item No. 99 but from 13th Storey to 16th Storey |
| 103 | S&F stainless steel plate rack 1.50 mm thick of over all size 1200mm X 900 mmx 250 mm as per trade pattern upto 16th storey complete all as specified and directed. |
| 104 | All as per above item No.103 but from 5th Storey to 8th Storey |
| 105 | All as per above item No.103 but from 9th Storey to 12th Storey |
| 106 | All as per above item No.103 but from 13th Storey to 16th Storey |
| 107 | POLYMER MODIFIED MORTAR: Supply and apply a pre-batched one component Polymer Modified Protective Mortar 15mm thick (PMPM) for Repair of spalling and damaged concrete in RCC structure and superstructure works, scope of work shall be including supply of materials, application, manpower, machinery, tools, consumables, curing etc., complete as per the direction of engineer –in charge. Make:Sika Top -122 or Equivalent in Fosroc etc |
| 108 | All as per above item No. 107 but from 5th Storey to 8th Storey |
| 109 | All as per above item No. 107 but from 9th Storey to 12th Storey |
| 110 | All as per above item No. 107 but from 13th Storey to 16th Storey |
| 111 | M&L for Providing & Pouring Micro concreting M-40 grade :-(i) Dry the concrete substrate surface and clean it free of debris & dust(ii) Apply Epoxy bond of approved make coat on the sound concrete sub strate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above, pour Micro concreting M-40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, formwork, lead & lift of materials, transportation etc., to carry out the complete work up to 16th floor complete all as specified and directed. |
| 112 | M&L for high strength corrosion resistant TMT bars 10mm dia and over cut to length bent to shape as in repairs to existing RCC damaged structure by welding or tying with bindig wire as per site requirement complete all as specified and directed up to 16th floor. |
| 113 | Drilling of holes in RCC members for fixing additional reinforcement with anchorage using RendroC Lokfix upto 16 th floor complete all as specified and directed. |
| 114 | Removing the Veg/plant growth from the surface of building complete with roots at any height and applying chemical to prevent further growth and making good using CM (1:3) and applying the finishes to match with existing surface including removal of debris out side premises complete all as specified and as directed. |
| 115 | All as per above item No. 114 but from 5th Storey to 8th Storey |
| 116 | All as per above item No. 114 but from 9th Storey to 12th Storey |
| 117 | All as per above item No. 114 but from 13th Storey to 16th Storey |
| 118 | M&L for Preparing old surfaces of walls by brooming down or by steel wire brushing and applying one coat of white wash upto 4th storey complete all as specified and as directed. |
| 119 | Complete removal of existing treatment and applying two coats of acrylic emulsion over one coat of alkali resistant primer on surfaces of ceilings . |
| 120 | All as per above item No. 119 but from 5th Storey to 8th Storey |
| 121 | All as per above item No. 119 but from 9th Storey to 12th Storey |
| 122 | All as per above item No. 119 but from 13th Storey to 16th Storey |
| 123 | M&L for preparing newly plastered surfaces of ceilings and and applying three coats of white wash up to 4th storey complete all as specified and as directed. |
| 124 | All as per above item No. 123 but from 5th Storey to 8th Storey |
| 125 | All as per above item No. 123 but from 9th Storey to 12th Storey |
| 126 | All as per above item No. 123 but from 13th Storey to 16th Storey |
| 127 | M&L for Preparation of newly plastered wall surfaces and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification, Two or more coats on new work over plastered surface to prepare the surface even and smooth and one coat of primer with alkaliresistant priming paint and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth. |
| 128 | All as per above item No. 127 but from 5th Storey to 8th Storey |
| 129 | All as per above item No. 127 but from 9th Storey to 12th Storey |
| 130 | All as per above item No. 127 but from 13th Storey to 16th Storey |
| 131 | Complete removal of existing treatment on old plastered wall surfaces and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats over plastered surface to prepare the surface even and smooth and one coat of primer with alkali resistant priming paint and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed. |
| 132 | All as per above item No. 131 but from 5th Storey to 8th Storey |
| 133 | All as per above item No. 131 but from 9th Storey to 12th Storey |
| 134 | All as per above item No. 131 but from 13th Storey to 16th Storey |
| 135 | Preparing old surfaces of walls and applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shad (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and prepare the surface even and smooth complete all as specified and as directed. |
| 136 | All as per above item No. 135 but from 5th Storey to 8th Storey |
| 137 | All as per above item No. 135 but from 9th Storey to 12th Storey |
| 138 | All as per above item No. 135 but from 13th Storey to 16th Storey |
| 139 | M&L for Writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high complete all as specified and as directed. |
| 140 | All as per above item No. 139 but from 5th Storey to 8th Storey |
| 141 | All as per above item No. 139 but from 9th Storey to 12th Storey |
| 142 | All as per above item No. 139 but from 13th Storey to 16th Storey |
| 143 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. |
| 144 | All as per above item No. 143 but from 5th Storey to 8th Storey |
| 145 | All as per above item No. 143 but from 9th Storey to 12th Storey |
| 146 | All as per above item No. 143 but from 13th Storey to 16th Storey |
| 147 | M&L for 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 148 | All as per above item No. 147 but from 5th Storey to 8th Storey |
| 149 | All as per above item No. 147 but from 9th Storey to 12th Storey |
| 150 | All as per above item No. 147 but from 13th Storey to 16th Storey |
| 151 | M&L for 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 152 | All as per above item No. 151 but from 5th Storey to 8th Storey |
| 153 | All as per above item No. 151 but from 9th Storey to 12th Storey |
| 154 | All as per above item No. 151 but from 13th Storey to 16th Storey |
| 155 | M&L for 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to floors complete all as specified and as directed. |
| 156 | All as per above item No. 155 but from 5th Storey to 8th Storey |
| 157 | All as per above item No. 155 but from 9th Storey to 12th Storey |
| 158 | All as per above item No. 155 but from 13th Storey to 16th Storey |
| 159 | M&L for 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to floors complete all as specified and as directed. |
| 160 | All as per above item No. 159 but from 5th Storey to 8th Storey |
| 161 | All as per above item No. 159 but from 9th Storey to 12th Storey |
| 162 | All as per above item No. 159 but from 13th Storey to 16th Storey |
| 163 | M&L for 160mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 164 | All as per above item No. 163 but from 5th Storey to 8th Storey |
| 165 | All as per above item No. 163 but from 9th Storey to 12th Storey |
| 166 | All as per above item No. 163 but from 13th Storey to 16th Storey |
| 167 | M&L for 160mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to floor complete all as specified and as directed. |
| 168 | All as per above item No. 167 but from 5th Storey to 8th Storey |
| 169 | All as per above item No. 167 but from 9th Storey to 12th Storey |
| 170 | All as per above item No. 167 but from 13th Storey to 16th Storey |
| 171 | M&L for PVC (SWR) plain Floor / Nahani trap of 75 mm dia., outlet with grating including jointing with solvent cement complete all as specified and as directed. |
| 172 | All as per above item No. 171 but from 5th Storey to 8th Storey |
| 173 | All as per above item No. 171 but from 9th Storey to 12th Storey |
| 174 | All as per above item No. 171 but from 13th Storey to 16th Storey |
| 175 | M&L for 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed. |
| 176 | All as per above item No. 175 but from 5th Storey to 8th Storey |
| 177 | All as per above item No. 175 but from 9th Storey to 12th Storey |
| 178 | All as per above item No. 175 but from 13th Storey to 16th Storey |
| 179 | M&L for 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed. |
| 180 | All as per above item No. 179 but from 5th Storey to 8th Storey |
| 181 | All as per above item No. 179 but from 9th Storey to 12th Storey |
| 182 | All as per above item No. 179 but from 13th Storey to 16th Storey |
| 183 | M&L for 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 184 | All as per above item No. 183 but from 5th Storey to 8th Storey |
| 185 | All as per above item No. 183 but from 9th Storey to 12th Storey |
| 186 | All as per above item No. 183 but from 13th Storey to 16th Storey |
| 187 | M&L for 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 188 | All as per above item No. 187 but from 5th Storey to 8th Storey |
| 189 | All as per above item No. 187 but from 9th Storey to 12th Storey |
| 190 | All as per above item No. 187 but from 13th Storey to 16th Storey |
| 191 | M&L for 75 mm bore PVC (SWR) branch piece, single(single y)equal or unequal complete all as specified and as directed. |
| 192 | All as per above item No. 191 but from 5th Storey to 8th Storey |
| 193 | All as per above item No. 191 but from 9th Storey to 12th Storey |
| 194 | All as per above item No. 191 but from 13th Storey to 16th Storey |
| 195 | M&L for 110mm bore PVC (SWR) branch piece, single(single y)equal or unequal complete all as specified and as directed. |
| 196 | All as per above item No. 195 but from 5th Storey to 8th Storey |
| 197 | All as per above item No. 195 but from 9th Storey to 12th Storey |
| 198 | All as per above item No. 195 but from 13th Storey to 16th Storey |
| 199 | M&L for 75mm bore PVC (SWR) branch piece, single(single y)equal or unequal with access door complete all as specified and as directed. |
| 200 | All as per above item No. 199 but from 5th Storey to 8th Storey |
| 201 | All as per above item No. 199 but from 9th Storey to 12th Storey |
| 202 | All as per above item No. 199 but from 13th Storey to 16th Storey |
| 203 | M&L for 75mm bore PVC (SWR) junction single 'T' Equal / unequal complete all as specified and as directed. |
| 204 | All as per above item No. 203 but from 5th Storey to 8th Storey |
| 205 | All as per above item No. 203 but from 9th Storey to 12th Storey |
| 206 | All as per above item No. 203 but from 13th Storey to 16th Storey |
| 207 | M&L for 110mm bore PVC (SWR) junction single 'T' Equal / unequal complete all as specified and as directed. |
| 208 | All as per above item No. 207 but from 5th Storey to 8th Storey |
| 209 | All as per above item No. 207 but from 9th Storey to 12th Storey |
| 210 | All as per above item No. 207 but from 13th Storey to 16th Storey |
| 211 | Taking up or down 15 mm bore steel tubing and connections, complete all as specified and as directed. |
| 212 | All as per above item No. 211 but from 5th Storey to 8th Storey |
| 213 | All as per above item No. 211 but from 9th Storey to 12th Storey |
| 214 | All as per above item No. 211 but from 13th Storey to 16th Storey |
| 215 | Taking up or down 20mm dia bore steel tubing and connections, complete all as specified and as directed. |
| 216 | All as per above item No. 215 but from 5th Storey to 8th Storey |
| 217 | All as per above item No. 215 but from 9th Storey to 12th Storey |
| 218 | All as per above item No. 215 but from 13th Storey to 16th Storey |
| 219 | Taking up or down 25mm dia or 32mm dia bore steel tubing and connections, complete all as specified and as directed. |
| 220 | All as per above item No. 219 but from 5th Storey to 8th Storey |
| 221 | All as per above item No. 219 but from 9th Storey to 12th Storey |
| 222 | All as per above item No. 219 but from 13th Storey to 16th Storey |
| 223 | Taking up or down 40mm or 50mm dia bore steel tubing and connections, complete all as specified and as directed. |
| 224 | All as per above item No. 223 but from 5th Storey to 8th Storey |
| 225 | All as per above item No. 223 but from 9th Storey to 12th Storey |
| 226 | All as per above item No. 223 but from 13th Storey to 16th Storey |
| 227 | Supplying and laying of CPVC pipes 20mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors complete all as specified and as directed. |
| 228 | All as per above item No. 227 but from 5th Storey to 8th Storey |
| 229 | All as per above item No. 227 but from 9th Storey to 12th Storey |
| 230 | All as per above item No. 227 but from 13th Storey to 16th Storey |
| 231 | Supplying and laying of CPVC pipes 25mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 232 | All as per above item No. 231 but from 5th Storey to 8th Storey |
| 233 | All as per above item No. 231 but from 9th Storey to 12th Storey |
| 234 | All as per above item No. 231 but from 13th Storey to 16th Storey |
| 235 | Supplying and laying of CPVC pipes 40mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls / ceilings or laying in floors complete all as specified and as directed. |
| 236 | All as per above item No. 235 but from 5th Storey to 8th Storey |
| 237 | All as per above item No. 235 but from 9th Storey to 12th Storey |
| 238 | All as per above item No. 235 but from 13th Storey to 16th Storey |
| 239 | Supplying and laying of CPVC pipes 50mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 240 | All as per above item No. 239 but from 5th Storey to 8th Storey |
| 241 | All as per above item No. 239 but from 9th Storey to 12th Storey |
| 242 | All as per above item No. 239 but from 13th Storey to 16th Storey |
| 243 | S&F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule up to 4 th storey complete all as specified and as directed. |
| 244 | All as per above item No. 243 but from 5th Storey to 8th Storey |
| 245 | All as per above item No. 243 but from 9th Storey to 12th Storey |
| 246 | All as per above item No. 243 but from 13th Storey to 16th Storey |
| 247 | S&F in repairs Fancy type chromium plated 15 mm bore Angle/ plain Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 248 | All as per above item No. 247 but from 5th Storey to 8th Storey |
| 249 | All as per above item No. 247 but from 9th Storey to 12th Storey |
| 250 | All as per above item No. 247 but from 13th Storey to 16th Storey |
| 251 | S&F in repairs Chromium plated shower rose 125 mm size with or without swivel joints complete all as specified and as directed. |
| 252 | All as per above item No. 251 but from 5th Storey to 8th Storey |
| 253 | All as per above item No. 251 but from 9th Storey to 12th Storey |
| 254 | All as per above item No. 251 but from 13th Storey to 16th Storey |
| 255 | S&F 50 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs complete all as specified and as directed. |
| 256 | All as per above item No. 255 but from 5th Storey to 8th Storey |
| 257 | All as per above item No. 255 but from 9th Storey to 12th Storey |
| 258 | All as per above item No. 255 but from 13th Storey to 16th Storey |
| 259 | S&F 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs complete all as specified and as directed. |
| 260 | All as per above item No. 259 but from 5th Storey to 8th Storey |
| 261 | All as per above item No. 259 but from 9th Storey to 12th Storey |
| 262 | All as per above item No. 259 but from 13th Storey to 16th Storey |
| 263 | S&F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe in repairs complete all as specified and as directed. |
| 264 | All as per above item No. 263 but from 5th Storey to 8th Storey |
| 265 | All as per above item No. 263 but from 9th Storey to 12th Storey |
| 266 | All as per above item No. 263 but from 13th Storey to 16th Storey |
| 267 | S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed. |
| 268 | All as per above item No. 267 but from 5th Storey to 8th Storey |
| 269 | All as per above item No. 267 but from 9th Storey to 12th Storey |
| 270 | All as per above item No. 267 but from 13th Storey to 16th Storey |
| 271 | S&F in repairs Stainless steel Soap dish ,any type , fixed to plugs with CP brass screws complete all as specified and as directed. |
| 272 | All as per above item No. 271 but from 5th Storey to 8th Storey |
| 273 | All as per above item No. 271 but from 9th Storey to 12th Storey |
| 274 | All as per above item No. 271 but from 13th Storey to 16th Storey |
| 275 | S&F in repairs Towel Ring, Stainless steel , Fancy Type fixed with chromium plated brass screws and wooden / plastic cleats weighing minimum 90 gms complete all as specified and as directed. |
| 276 | All as per above item No. 275 but from 5th Storey to 8th Storey |
| 277 | All as per above item No. 275 but from 9th Storey to 12th Storey |
| 278 | All as per above item No. 275 but from 13th Storey to 16th Storey |
| 279 | S&F in rapairs Brass Chromium plated tubular towel rail, 20 mm dia., 'D' Type, 60 cm long between flanges complete all as specified and as directed. |
| 280 | All as per above item No. 279 but from 5th Storey to 8th Storey |
| 281 | All as per above item No. 279 but from 9th Storey to 12th Storey |
| 282 | All as per above item No. 279 but from 13th Storey to 16th Storey |
| 283 | S&F in repairs 600mm x 450mm beveled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washercomplete all as specified and as directed. |
| 284 | All as per above item No. 283 but from 5th Storey to 8th Storey |
| 285 | All as per above item No. 283 but from 9th Storey to 12th Storey |
| 286 | All as per above item No. 283 but from 13th Storey to 16th Storey |
| 287 | S&F in repairs Vitreous China (white) EWC type water closet floor mounted (size 560mm x 440mm x 395mm or nearest size) confirming to IS 2556 part II of pettern 1 having P trap with 10 litres PVC capacity valve less syphonic action type flushing cistern low level (white) with inlet, ball valve, float and handle including brackets (SLIM LINE or equivalent) including PVC flush pipe 32 mm dia, plastic seat cover of white colour to WC (which shall be thermosetting materal confirming to IS 2538, underside of seat shall be flat and seat shall be of solid moulding 3mm thick & cover shall be 3 mm thick), hinging device brass chromium plated 2 bolts per seat, 4 numbers rubber plastic buffers including removing the existing water closet complete upto 4th storey. |
| 288 | All as per above item No. 287 but from 5th Storey to 8th Storey |
| 289 | All as per above item No. 287 but from 9th Storey to 12th Storey |
| 290 | All as per above item No. 287 but from 13th Storey to 16th Storey |
| 291 | S&F in repairs Rotational moulded Polythene [HDPE] rectangle Water storage loft Tank, 225 Liters Capacity hoisted and fixed in position upto 16 th storey complete all as specified and as directed. |
| 292 | All as per above item No. 291 but from 5th Storey to 8th Storey |
| 293 | All as per above item No. 291 but from 9th Storey to 12th Storey |
| 294 | All as per above item No. 291 but from 13th Storey to 16th Storey |
| 295 | S&F 20 mm dia Ball brass Valves, high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule complete all as specified and as directed. |
| 296 | All as per above item No. 295 but from 5th Storey to 8th Storey |
| 297 | All as per above item No. 295 but from 9th Storey to 12th Storey |
| 298 | All as per above item No. 295 but from 13th Storey to 16th Storey |
| 299 | S&F in rapirs Vitreous China Ware Wash hand basin white,half pedestal, flat back, size 550 x 400 mm size with 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed including removing the existing Basin, pillar tap and brackets and fixing new brackets complete. |
| 300 | All as per above item No. 299 but from 5th Storey to 8th Storey |
| 301 | All as per above item No. 299 but from 9th Storey to 12th Storey |
| 302 | All as per above item No. 299 but from 13th Storey to 16th Storey |
| 303 | Taking down Chowkats or frames with shutters not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and as directed. |
| 304 | All as per above item No. 303 but from 5th Storey to 8th Storey |
| 305 | All as per above item No. 303 but from 9th Storey to 12th Storey |
| 306 | All as per above item No. 303 but from 13th Storey to 16th Storey |
| 307 | Taking down Chowkats or frames with shutters exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) complete all as specified and as directed. |
| 308 | All as per above item No. 307 but from 5th Storey to 8th Storey |
| 309 | All as per above item No. 307 but from 9th Storey to 12th Storey |
| 310 | All as per above item No. 307 but from 13th Storey to 16th Storey |
| 311 | S & F factory made single extruded WPC (Wood Polymer Composite) solid door/ window Frames/ Chowkhats of size 65 mm x 100 mm comprising of virgin PVC polymer of 'K' value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as spefied and as directed. |
| 312 | All as per above item No.311 but from 5th Storey to 8th Storey |
| 313 | All as per above item No. 311 but from 9th Storey to 12th Storey |
| 314 | All as per above item No. 311 but from 13th Storey to 16th Storey |
| 315 | S & F factory made single extruded WPC (Wood Polymer Composite) solid door/ window Frames/ Chowkhats of size 50 mm x 100 mm comprising of virgin PVC polymer of 'K' value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as spefied and as directed. |
| 316 | All as per above item No. 315 but from 5th Storey to 8th Storey |
| 317 | All as per above item No. 315 but from 9th Storey to 12th Storey |
| 318 | All as per above item No. 315 but from 13th Storey to 16th Storey |
| 319 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: stainless steel butt hinges and necessary S S screws shall be paid separately under relevant item. |
| 320 | All as per above item No. 319 but from 5th Storey to 8th Storey |
| 321 | All as per above item No. 319 but from 9th Storey to 12th Storey |
| 322 | All as per above item No. 319 but from 13th Storey to 16th Storey |
| 323 | S&F factory made Double rebated Wood Polymer Composite [WPC] solid door/ window Frames/ Chowkhats of size 65mm x 125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as specied and as directed. Note: The hold fasts/ lugs/ fasteners shall be measured and paid separately under relevant items of this Schedule/ BoQ. |
| 324 | All as per above item No. 323 but from 5th Storey to 8th Storey |
| 325 | All as per above item No. 323 but from 9th Storey to 12th Storey |
| 326 | All as per above item No. 323 but from 13th Storey to 16th Storey |
| 327 | M & L for cupboard shutters / Panelling work 19 mm thick, factory made from Block Board (BWR grade, IS:1659), finished on both sides with 1.0 mm thick decorative laminate (ISI marked, shade/pattern as approved by Engineer-in-Charge), edges lipped with matching mica strips, machine pressed with synthetic resin adhesive (as per IS:2046) to obtain uniform finish, including preparation of surfaces, rounding/finishing edges complete all as specified and directed. |
| 328 | All as per above item No. 327 but from 5th Storey to 8th Storey |
| 329 | All as per above item No. 327 but from 9th Storey to 12th Storey |
| 330 | All as per above item No. 327 but from 13th Storey to 16th Storey |
| 331 | S & F 30 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 332 | All as per above item No. 331 but from 5th Storey to 8th Storey |
| 333 | All as per above item No. 331 but from 9th Storey to 12th Storey |
| 334 | All as per above item No. 331 but from 13th Storey to 16th Storey |
| 335 | S & F 4mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face; fixed with screws to timber frame work including veneer polishing complete all as specified and as directed. |
| 336 | All as per above item No. 335 but from 5th Storey to 8th Storey |
| 337 | All as per above item No. 335 but from 9th Storey to 12th Storey |
| 338 | All as per above item No. 335 but from 13th Storey to 16th Storey |
| 339 | S & F 35 mm thick Factory made Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. The sizes of members of shutters shall be as specified in SSR Part I, Section 8, Clause 8.20 (a) complete all as specified and as directed. |
| 340 | All as per above item No. 339 but from 5th Storey to 8th Storey |
| 341 | All as per above item No. 339 but from 9th Storey to 12th Storey |
| 342 | All as per above item No. 339 but from 13th Storey to 16th Storey |
| 343 | S&F 35mm thick factory made second class hard wood, kiln seasoned and chemically pressure treated plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm thick veneered partilce board complete all as specified and as directed. |
| 344 | All as per above item No. 343 but from 5th Storey to 8th Storey |
| 345 | All as per above item No. 343 but from 9th Storey to 12th Storey |
| 346 | All as per above item No. 343 but from 13th Storey to 16th Storey |
| 347 | S & F Factory made Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. |
| 348 | All as per above item No. 347 but from 5th Storey to 8th Storey |
| 349 | All as per above item No. 347 but from 9th Storey to 12th Storey |
| 350 | All as per above item No. 347 but from 13th Storey to 16th Storey |
| 351 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 352 | All as per above item No. 351 but from 5th Storey to 8th Storey |
| 353 | All as per above item No. 351 but from 9th Storey to 12th Storey |
| 354 | All as per above item No. 351 but from 13th Storey to 16th Storey |
| 355 | M&L Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc.upto 16 th floor Complete all as specified and as directed. |
| 356 | M&L for Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with Stainless steel wire staples complete all as specified and as directed. |
| 357 | All as per above item No. 356 but from 5th Storey to 8th Storey |
| 358 | All as per above item No. 356 but from 9th Storey to 12th Storey |
| 359 | All as per above item No. 356 but from 13th Storey to 16th Storey |
| 360 | Dismantling ply wood cub board shutters including cubboard shelves complete all as specified and as directed. |
| 361 | All as per above item No. 360 but from 5th Storey to 8th Storey |
| 362 | All as per above item No. 360 but from 9th Storey to 12th Storey |
| 363 | All as per above item No. 360 but from 13th Storey to 16th Storey |
| 364 | M&L for Powder coated aluminium sections of approved colour for doors, Windows, Ventilators, Partitions, with frames and shutters fully or partly glazed, sliding / openable, with extruded aluminium sections not less than 1.5mm thick and powder coating not less than 60 micron thick including necessary jointing cleats, rubber beading, neoprene packing, aluminium snap beading, screws, powder coated aluminium fittings such as handles, aluminium butt hinges , aluminium tower bolts, stainless steel friction hinges, locking arrangements etc. complete all as specified and as directed. Notes:[a] The size of aluminium extruded sections shall conform to Designation 63400 all shall be as specified in relevant IS code and as specified in MES Schedule Part - I. [b] Panel inserts such as Glass / Particle board / Gauze shall be measured and paid separately at supply only rates.[c] Weight of aluminium sections shall only be accounted for payment purpose. Weight of aluminium Handles, Butt Hinges & Tower Bolts shall not be accounted for payment purpose. [d] The unit rate quoted shall be deemed to include for cost of jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges,Peg stays, locking arrangements etc., and fixing only of panel inserts of glass / particle board / gauge etc. |
| 365 | All as per above item No.364 but from 5th Storey to 8th Storey |
| 366 | All as per above item No. 364 but from 9th Storey to 12th Storey |
| 367 | All as per above item No. 364 but from 13th Storey to 16th Storey |
| 368 | Supply 4.8 mm thick Sheet tinted glass, ordinary quality fixed to aluminium windows in squares exceeding 0.5 Sq. M in each pane complete all as specified and as directed. |
| 369 | All as per above item No. 368 but from 5th Storey to 8th Storey |
| 370 | All as per above item No. 368 but from 9th Storey to 12th Storey |
| 371 | All as per above item No. 368 but from 13th Storey to 16th Storey |
| 372 | Supply only 4.8 mm thick Sheet tinted glass, ordinary quality fixed to aluminium windows in squares not exceeding 0.5 Sq. M in each pane complete all as specified and as directed. |
| 373 | All as per above item No. 372 but from 5th Storey to 8th Storey |
| 374 | All as per above item No 372 but from 9th Storey to 12th Storey |
| 375 | All as per above item No. 372 but from 13th Storey to 16th Storey |
| 376 | Supply only 4 mm thick figered glass, fixed to aluminium windows in squares not exceeding 0.5 Sq. M in each pane complete all as specified and as directed. |
| 377 | All as per above item No. 376 but from 5th Storey to 8th Storey |
| 378 | All as per above item No. 376 but from 9th Storey to 12th Storey |
| 379 | All as per above item No. 376 but from 13th Storey to 16th Storey |
| 380 | M&L for 12 mm thick Prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination & other side balancing white lamination, fixed to aluminium door up to 4th storey complete all as specified and as directed. |
| 381 | All as per above item No. 380 but from 5th Storey to 8th Storey |
| 382 | All as per above item No. 380 but from 9th Storey to 12th Storey |
| 383 | All as per above item item No. 380 but from 13th Storey to 16th Storey |
| 384 | S & F 200 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy up to 4th storey complete all as specified and as directed. |
| 385 | All as per above item No. 384 but from 5th Storey to 8th Storey |
| 386 | All as per above item No. 384 but from 9th Storey to 12th Storey |
| 387 | All as per above item No. 384 but from 13th Storey to 16th Storey |
| 388 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed. |
| 389 | All as per above item No. 388 but from 5th Storey to 8th Storey |
| 390 | All as per above item No 388 but from 9th Storey to 12th Storey |
| 391 | All as per above item No. 388 but from 13th Storey to 16th Storey |
| 392 | S & F 125 mm long extruded stainless steel Butt hinges with galvanized mild steel hinge pin complete all as specified and as directed. |
| 393 | All as per above item No. 392 but from 5th Storey to 8th Storey |
| 394 | All as per above item No. 392 but from 9th Storey to 12th Storey |
| 395 | All as per above item No. 392 but from 13th Storey to 16th Storey |
| 396 | S & F 100 long extruded stainless steel Butt hinges with galvanized mild steel hinge pin complete all as specified and as directed. |
| 397 | All as per above item No. 396 but from 5th Storey to 8th Storey |
| 398 | All as per above item No. 396 but from 9th Storey to 12th Storey |
| 399 | All as per above item No. 396 but from 13th Storey to 16th Storey |
| 400 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 401 | All as per above item No. 400 but from 5th Storey to 8th Storey |
| 402 | All as per above item No. 400 but from 9th Storey to 12th Storey |
| 403 | All as per above item No. 400 but from 13th Storey to 16th Storey |
| 404 | S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 405 | All as per above item No. 404 but from 5th Storey to 8th Storey |
| 406 | All as per above item No. 404 but from 9th Storey to 12th Storey |
| 407 | All as per above item No. 404 but from 13th Storey to 16th Storey |
| 408 | S & F door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring,, Overall length of cover plate 150 mm complete all as specified and as directed. |
| 409 | All as per above item No. 408 but from 5th Storey to 8th Storey |
| 410 | All as per above item No. 408 but from 9th Storey to 12th Storey |
| 411 | All as per above item No. 408 but from 13th Storey to 16th Storey |
| 412 | S&F Mild steel, bright finished or electro galvanised continuous (piano) hinges width of flaps (when open) 40mm complete all as specified and directed. |
| 413 | All as per above item No. 412 but from 5th Storey to 8th Storey |
| 414 | All as per above item No. 412 but from 9th Storey to 12th Storey |
| 415 | All as per above item No. 412 but from 13th Storey to 16th Storey |
| 416 | S&F Brass Hat and Coat hooks , Solid body, 175mm to 250mm size upto 16 th storey complete all as specified and directed. |
| 417 | All as per above item No. 416 but from 5th Storey to 8th Storey |
| 418 | All as per above item No. 416 but from 9th Storey to 12th Storey |
| 419 | All as per above item No. 416 but from 13th Storey to 16th Storey |
| 420 | S&F brass cup board lock 75mm size 4 lever with duplicate keys complete all as specified and as directed. |
| 421 | All as per above item No. 420 but from 5th Storey to 8th Storey |
| 422 | All as per above item No. 420 but from 9th Storey to 12th Storey |
| 423 | All as per above item No. 420 but from 13th Storey to 16th Storey |
| 424 | S&F SS handles extruded fabricated type 100mm size complete all as specified and as directed. |
| 425 | All as per above item No. 424 but from 5th Storey to 8th Storey |
| 426 | All as per above item No. 424 but from 9th Storey to 12th Storey |
| 427 | All as per above item No. 424 but from 13th Storey to 16th Storey |
| 428 | S&F magnetic catch complete all as specified and as directed. |
| 429 | All as per above item No. 428 but from 5th Storey to 8th Storey |
| 430 | All as per above item No. 428 but from 9th Storey to 12th Storey |
| 431 | All as per above item No. 428 but from 13th Storey to 16th Storey |
| 432 | S&F 300 mm, Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 433 | All as per above item No. 432 but from 5th Storey to 8th Storey |
| 434 | All as per above item No. 432 but from 9th Storey to 12th Storey |
| 435 | All as per above item No. 432 but from 13th Storey to 16th Storey |
| 436 | S&F Mortice night latch, of size 82mm, 7 levers ,Zink based die cast alloy body and two keys upto 4 th storey complete all as specified and directed. |
| 437 | All as per above item No. 436 but from 5th Storey to 8th Storey |
| 438 | All as per above item No. 436 but from 9th Storey to 12th Storey |
| 439 | All as per above item No. 436 but from 13th Storey to 16th Storey |
| 440 | S&F Stainless Steel curtain rod 25mm dia with suitable SS brackets and Designer knobs at ends matching to curtain rod of make as as approved by GE upto 4th storey complete all as specified and as directed.Note: Additional supporting bracket shall be provided if length is exceeding 1.2m and rate quoted shall include for the same |
| 441 | All as per above item No. 440 but from 5th Storey to 8th Storey |
| 442 | All as per above item No. 440 but from 9th Storey to 12th Storey |
| 443 | All as per above item No. 440 but from 13th Storey to 16th Storey |
| 444 | M&L for Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed. |
| 445 | All as per above item No. 444 but from 5th Storey to 8th Storey |
| 446 | All as per above item No. 444 but from 9th Storey to 12th Storey |
| 447 | All as per above item No. 444 but from 13th Storey to 16th Storey |
| 448 | M & L for Providing and injecting chemical emulsion for Anti Termite Treatment along the external wall below concrete or masonry apron using chemical emulsion at the rate of 2.25 litres per linear metre including drilling and plugging holes etc., in apron complete all as specified and as directed. |
| 449 | M&L for treating the soil under exiting floor using lindane emulsifiable conforming to IS : 632 with emulsion @ 1 liter per hole 300mm aprat including drilling and plugging 12mm dia hole with cement mortor 1:2 (1cement : 2sand) to match the existing floors complete all as specified and as directed. |
| 450 | M&L for treatment at point of contact to wood work by chemical emulsion (water base solutiobn) @ 0.5 ltr / hole by drilling 6mm dia holes at a downward angle of 45 degree at 1.5 mm centre to centre and sealing the same upto 4th storey complete all as specified and as directed. |
| 451 | All as per above item No. 450 but from 5th Storey to 8th Storey |
| 452 | All as per above item No. 450 but from 9th Storey to 12th Storey |
| 453 | All as per above item No. 450 but from 13th Storey to 16th Storey |
| 454 | S&F in repairs 600mm X 450mm Cabinet Mirror of selected quality and approved make, glass minimum 5mm thick and fixed to wooden plug with CP brass screws and cup washers upto 4th storey complete all as specified and as directed. |
| 455 | All as per above item No. 454 but from 5th Storey to 8th Storey |
| 456 | All as per above item No. 454 but from 9th Storey to 12th Storey |
| 457 | All as per above item No. 454 but from 13th Storey to 16th Storey |
| 458 | S&F PVC corner half round corner beading not exceeding 15 mm girth fixed to tile junctions complete all as specified and as directed up to 16 th storey. |
| 459 | S&F in rapairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.5 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 460 | All as per above item No. 459 but from 5th Storey to 8th Storey |
| 461 | All as per above item No. 459 but from 9th Storey to 12th Storey |
| 462 | All as per above item No. 459 but from 13th Storey to 16th Storey |
| 463 | S&F in repairs 15 mm bore chromium plated 2 way bib taps with wall flange, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron or CPVC pipe or for brass ferrule up to 4th storey. Make : Jaquar : OPP-CHR-15041PM or equivalent in other approved make as approved by GE |
| 464 | All as per above item No. 463 but from 5th Storey to 8th Storey |
| 465 | All as per above item No. 463 but from 9th Storey to 12th Storey |
| 466 | All as per above item No. 463 but from 13th Storey to 16th Storey |
| 467 | S & F in repairs Wall Mixer with Provision for Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges including all necessary fittings complete all as specified and as directed.Make: Jaquar catloque No-SOL-6273UPR or equivalent in other approved make as approved by GE |
| 468 | All as per above item No. 467 but from 5th Storey to 8th Storey |
| 469 | All as per above item No. 467 but from 9th Storey to 12th Storey |
| 470 | All as per above item No. 467 but from 13th Storey to 16th Storey |
| 471 | S&F in repairs readymade pully operated cloth drying system including 4 Aluminium pipes ,channel assembly , locking system ropes and fitted material 7 feet long (4 pipe set) all as specified and directed by Engineer-in-charge. Make : Easy dry or equivalent make as approved. |
| 472 | All as per above item No. 471 but from 5th Storey to 8th Storey |
| 473 | All as per above item No. 471 but from 9th Storey to 12th Storey |
| 474 | All as per above item No. 471 but from 13th Storey to 16th Storey |
| 475 | S&F in repairs Pillar taps, with fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 476 | All as per above item No. 475 but from 5th Storey to 8th Storey |
| 477 | All as per above item No. 475 but from 9th Storey to 12th Storey |
| 478 | All as per above item No. 475 but from 13th Storey to 16th Storey |
| 479 | M&L for in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long etc complete all as speicified and as directed. |
| 480 | All as per above item No. 479 but from 5th Storey to 8th Storey |
| 481 | All as per above item No. 479 but from 9th Storey to 12th Storey |
| 482 | All as per above item No. 479 but from 13th Storey to 16th Storey |
| 483 | S&F in repairs Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed. |
| 484 | All as per above item No. 483 but from 5th Storey to 8th Storey |
| 485 | All as per above item No. 483 but from 9th Storey to 12th Storey |
| 486 | All as per above item No. 483 but from 13th Storey to 16th Storey |
| 487 | Dismantling Structural steel work including doors, gates but excluding framed truss upto 16th floor etc. complete all as specified and as directed. |
| 488 | M&L for preparing old surfaces of steel and iron work of any description over 10 cm width or grith not otherwise described and applying two coats of synthetic enamel paint complete all as specified and as directed. |
| 489 | All as per above item No. 488 but from 5th Storey to 8th Storey |
| 490 | All as per above item No. 488 but from 9th Storey to 12th Storey |
| 491 | All as per above item No. 488 but from 13th Storey to 16th Storey |
| 492 | S & F powder caoted aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainlesssteel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around theopening complete as per requirement and direction of Engineerin-charge. |
| 493 | All as per above item No. 492 but from 5th Storey to 8th Storey |
| 494 | All as per above item No. 492 but from 9th Storey to 12th Storey |
| 495 | All as per above item No. 492 but from 13th Storey to 16th Storey |
| 496 | M&L for 75 mm thick Plain Cement Concrete type D-2 (1:4:8) ( using 40mm graded aggregates ) as in sub base etc. complete all as specified and as directed. |
| 497 | M&L for preparation of new plastered wall surfaces and applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and prepare the surface even and smooth complete all as specified and as directed. |
| 498 | All as per above item No. 497 but from 5th Storey to 8th Storey |
| 499 | All as per above item No. 497 but from 9th Storey to 12th Storey |
| 500 | All as per above item No. 497 but from 13th Storey to 16th Storey |
| 501 | M&L for Cutting holes into or through brick walls exceeding 400 sq. cm but not exceeding 0.10 Sqm built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed. |
| 502 | All as per above item No. 501 but from 5th Storey to 8th Storey |
| 503 | All as per above item No. 501 but from 9th Storey to 12th Storey |
| 504 | All as per above item No. 501 but from 13th Storey to 16th Storey |
| 505 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth etc complete |
| 506 | All as per above item No. 505 but from 5th Storey to 8th Storey |
| 507 | All as per above item No. 505 but from 9th Storey to 12th Storey |
| 508 | All as per above item No. 505 but from 13th Storey to 16th Storey |
| 509 | S&Fin repairs corner glass shelf assembly consisting of 5.5mm thick sheet glass shelf with chromium plated bracket guard etc complete. |
| 510 | All as per above item No. 509 but from 5th Storey to 8th Storey |
| 511 | All as per above item No. 509 but from 9th Storey to 12th Storey |
| 512 | All as per above item No. 509 but from 13th Storey to 16th Storey |
| 513 | Supply only Integral water proofing compound |
| 514 | Removing of debris to out side the premises to a distance of 15 KM all as directed by Engineer in Charge |
| 515 | M&L for 18 to 20mm Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in screed bed bedding layer,15 mm thick in cement mortar 1:6 complete all as required site including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and as directed. |
| 516 | All as per above item No. 515 but from 5th Storey to 8th Storey |
| 517 | All as per above item No. 515 but from 9th Storey to 12th Storey |
| 518 | All as per above item No. 515 but from 13th Storey to 16th Storey |
| 519 | M&L for 18 to 20mm Granite( of any type) work (table rubbed and polished) for wall lining (veneering to wall) 10mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 520 | All as per above item No. 519 but from 5th Storey to 8th Storey |
| 521 | All as per above item No. 519 but from 9th Storey to 12th Storey |
| 522 | All as per above item No. 519 but from 13th Storey to 16th Storey |
| 523 | M&L for Green marble slab 16 to 18 mm thick (table rubbed and polished ) machine cut as in flooring and landings of stair case over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and half rounding edges over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 upto 16 th storey complete all as specified and as directed. |
| 524 | All as per above item No. 523 but from 5th Storey to 8th Storey |
| 525 | All as per above item No. 523 but from 9th Storey to 12th Storey |
| 526 | All as per above item No. 523 but from 13th Storey to 16th Storey |
| 527 | M&L for demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc , laidd,bedded and pointed in any mortar complete all as specified and as directed. |
| 528 | M&L for 50 mm thick sand filling under floors or in foundations below interlocking tiles path including watering and consolidation complete all as specified and as directed. |
| 529 | M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and as directed. |
| 530 | M&L for Providing, cement concrete Type B1 1:2:4 ( using 20mm graded aggregate) in Mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 531 | M&L for Plain Cement Concrete Type B2, 1:2:4 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete etc complete all as specified and as directed. |
| 532 | M&L for Pre-cast Cement Concrete block masonry Type C1 ( using 20mm graded aggregates ) with solid blocks, exceeding 10cm in width and setting in cement mortar, complete in full brick thick walls set in cement mortar 1:6 complete all as specified and as directed. |
| 533 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement.complete all as specified and as directed. |
| 534 | M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate ) as in copings complete all as specified and as directed. |
| 535 | Extra for forming fair finished drain not exceeding 60 cm inner girth in cement concrete, using extra cement complete all as specified and as directed. |
| 536 | Demolition of reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal off unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and as directed. |
| 537 | M&L for Mild steel deformed or TMT bars 8 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed. |
| 538 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Soft / Loose soil Complete all as specified and as directed.Note: Demolition of drain pipe shall be measured and paid separately under relevant item. |
| 539 | Excavation in trenches, not exceeding 1.5 M wide and exceeding 1.5 M and not exceeding 3m depth for foundation, etc., and getting out in Soft/Loose soil.Complete all as specified and as directed.Note: Demolition of drain pipe shall be measured and paid separately under relevant item. |
| 540 | Demolition and breaking 150 mm dia., drain pipes (Salt glazed ware, AC or reinforced concrete ) set in cement mortar and disposal off unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and as directed. |
| 541 | Demolition and breaking 200 mm dia., drain pipes (Salt glazed ware, AC or reinforced concrete ) set in cement mortar and disposal off unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and as directed. |
| 542 | M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and as directed. |
| 543 | M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 200 mm bore complete all as specified and as directed. |
| 544 | M&L for 150mm dia Reinforced Concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed. |
| 545 | M&L for 200mm dia Reinforced Concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed. |
| 546 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil complete all as specified and as directed. |
| 547 | Removing Excavated soil to a distance execeeding 1.50 km but not exceeding 5 KM and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and as directed. |
| 548 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and as directed. |
| 549 | M&L for Plain Cement Concrete type D2 (1:4:8) (using 40 mm garded stone aggr) as in foundations, filling and mass concrete etc complete all as specified and as directed. |
| 550 | M&L for Precast Cement Concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) as in landings, bed plates, pintle blocks, anchorage blocks, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form work , complete all as specified and as directed. |
| 551 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 150 mm dia., of pipe complete all as specified and as directed. |
| 552 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 200 mm dia., of pipe complete all as specified and as directed. |
| 553 | M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate ) as in Benching of Manholes complete all as specified and as directed. |
| 554 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 555 | Taking down carefully by unscrewing from boards, TV Sockets, LAN sockets and Computer jack, etc. complete all as specified and as directed. |
| 556 | Taking down unserviceable main switches, DBs, bus bars chambers any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed. |
| 557 | Taking down unserviceable single pole and neutral enclosure with two pin and earth plug and socket any type/ any rating including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed. |
| 558 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. |
| 559 | Taking down of LED light any Type any Model and Make complete all as specified and as directed. |
| 560 | Taking down after disconnection the Exhaust fans any make, model, size and type from its position complete with all the parts i.e. down rod, canopies, fan blades etc.completeall as specified and directed. |
| 561 | Taking down after disconnection the Ceiling fans any make, model, size and type from its position complete with all the parts i.e. down rod, canopies, fan blades etc. and deposit in MES store yard complete all as specified and as directed. |
| 562 | Taking down existing storage type wate heater of any capacity of any type and size by disconnecting from Power socket, carring out necessary repair and painting including cleaning and inner water tank, removing of hard water deposites and connected back and refixing in original position including testing and commissioning complete all as specified and deposit of MES store yard. |
| 563 | Taking down after disconnection of existing electric meter any make model and type from wall complete all as specified and deposit of MES store yard. |
| 564 | M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) surface fitted type including Flush type metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed.Note : The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. |
| 565 | All as per item No. 564 above but for One light Point controlled by 2- Way Switch all as specified and directed. |
| 566 | All as per item No. 564 above but for one 5 Amp socket outlet point on same board complete all as specified and as directed. |
| 567 | All as per item No. 564 above but for one 5 Amps socket independent including 1.5 Sqmm earth continuty FRLSH Copper Cable all as specified and as directed. |
| 568 | All asper item No. 564 above but with 2.5 Sqmm FRLSH copper cable for one 15/5 Amps Multipurpose power point Including 2.5 Sq mm FRLSH copper conductor cable for earth continuity conductor and connecting it to earth all as specified and as directed. |
| 569 | All as per item No.564 abvoe but One 3 pin socket outlet 15 amps socket on independent board with 4 sqmm FRLSH PVC wire for phase and neutral and one run of 4 sqmm copper cable green in colour for earth continuty conductor complete all as specified and as directed. |
| 570 | S & F TV Socket outlet with metal box complete all as specified and as directed. |
| 571 | S & F switch Modular type single pole 6 Amps One Way AC 230V, 50HZ supply complete all as specified and as directed. |
| 572 | S & F switch Modular type single pole 6 Amps Two Way AC 230V, 50HZ supply complete all as specified and as directed. |
| 573 | S & F Bell Push Modular type single pole 6 Amps AC 230V, 50HZ supply complete all as specified and as directed. |
| 574 | S & F Modular type socket 5A AC 230V, 50HZ complete all as specified and as directed. |
| 575 | S & F Modular type switch 16A AC 230CV, 50Hz complete all as specified and as directed. |
| 576 | S & F Modular type Socket 6A/16A multi purpose AC 230CV, 50Hz complete all as specified and as directed. |
| 577 | S&F Modular Fan step regulator, 120W - 2 module complete all as specified and as directed. |
| 578 | S&F Celing rose surface backlite 63 mm dia two to three terminals complete all as specified and as directed. |
| 579 | S&F Buzzer, Ding Dong AC. 230 volts,single pole complete all as specified and as directed. |
| 580 | S&F Single pole and neutral enclosure with two pin and earth plug and socket with 20 amps MCB SP complete all as specified and as directed. |
| 581 | M & L Sub main wiring with 2runs of 2.5 Sqmm PVC insulated FRLSH Copper conductor cable including PVC conduit of Suitable along with one run of 2.5 Sq.mm FR copper cable for earth continuity conductor as earth lead for sub main wiring and connecting to common earth dolly complete all as specified and as directed.Note : 3runs of cable and one run of conduit shall be measured as one unit. |
| 582 | M & L Sub main wiring with 2 runs of 6.0 Sqmm PVC insulated FRLSH Copper conductor cable including PVC conduit of Suitable along with one run of 6.0 Sq.mm FRLS copper cable for earth continuity conductor as earth lead for sub main wiring and connecting to common earth dolly.( TPN to SPN DB) complete all as specified and as directed.Note : 3runs of cable and one run of conduit shall be measured as one unit. |
| 583 | S&F TPN DB 4 Way with 415 amps rated bus bar Double Door vertical type complete all as specified and as directed. |
| 584 | S&F 415 V, 10 KA 'C' curve Miniature Circuit Breaker (MCB) of Three poles and Netural current carrying capacity 63 AMP, in the MCB DB complete all as specified and directed. |
| 585 | S&F SPN DB 12 Way with 200 amps rated bus bar Double Door vertical type complete all as specified and as directed. |
| 586 | S&F 240V, 10 KA 'C' curve Miniature Circuit Breaker (MCB) of single pole and Netural current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 587 | S&F 240V, 10 KA 'C' curve Miniature Circuit Breaker (MCB) of single pole, current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 588 | S&F LED light fittings 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 589 | Fixing only LED tube light fitting any watt any make and model, obtained from Item No. 559 above 220V, AC and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 590 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 591 | Fixing only LED mirror light fitting any watt any make and model, obtained from Item No. 559 above 220V, AC and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 592 | S & F LED light fitting 1x9W/1X10W bulkhead,luminaires including LED light driver holder,connecting up with three core flexible copper,conductor cable of suitable size complete all as specified and as directed. |
| 593 | Fixing only LED bulkhead fitting any watt any make and model, obtained from Item No. 559 above 220V, AC and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 594 | S&F LED Building Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, with all accessories including 1.5 sqmm weather proof 3 core FRLS grade copper conductor to fitting including 40/32 mm dia medium grade 1.5 mtr length GI pipe for fixing of street lights including nuts, bolt and washer etc and taking down existing complete all as specified and as directed. |
| 595 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable forbatten fittings complete all as specified and as directed. |
| 596 | S & F in repairs LED Bulb, 9 Watts IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. |
| 597 | S& F in repair stationary louvers suitable for exhaust fan of 300 mm sweep made out of powder coated aluminium anodized sheet of minimum 1 mm thick with non removable blades fixed permanently at 45 degree angle for protection from rain including aluminium wire mess for protection of birds complete all as specified and as directed. |
| 598 | S & F Rigid non-metalic PVC conduit(20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and as directed. |
| 599 | S&F Aviation obstruction light of LED type integral light comprising of aluminium housing with polycarbonate enclosure,302 nos LED are provided along with other fixing aceessories internal prewired and including taking down existing light fittings of any complete all as specified and directed. |
| 600 | Fixing only exhaust fan of any Make, model, sweep and type including connecting up including provision of cable from ceiling rose/connector to fan obtained from Item No. 560 above all as specified and directed. |
| 601 | Fixing/ Hanging only Ceiling fan of any Make, model, sweep and type including connecting up including provision of cable from ceiling rose/connector to fan Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. obtained from Item No. 561 above all as specified and directed. |
| 602 | Scrapping and painting of existing MS Box of size 900x600x150mm inside the wall for fixing of DBs and meter complete all as specified and as directed. |
| 603 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI Earth wire 4 mm dia by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 15 mm dia light grade for protection of earth electrode 20 mm dia for watering including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of soil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one all as specified and directed and tested on completion |
| 604 | S & F in 4mm dia galvanised iron or steel wire Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all specified and directed. |
| 605 | Taking down old / perished earth pits and making good the disturbed surface of complete all as specified and as directed. |
| 606 | Taking down of Aluminium strip/ GI Strip of lightning conductor having any size and dimension (roof conductors)/down conductors) laid in trench/floor including taking down of clamps,nuts,bolts complete all as specified and as directed. |
| 607 | Taking down of Air termination, single pointed aluminium rod of any size complete all as specified and as directed. |
| 608 | S&F Aluminium strip of size 25x3.15 mm for lightning conductor (roof conductors)/down conductors) laid in trench/floor including necessery clamps,nuts,bolts and hylem sheet block complete all as specified and as directed. |
| 609 | Fixing only Aluminium strip of size 25x3.15 mm for lightning conductor (roof conductors)/down conductors) laid in trench/floor including necessery clamps,nuts,bolts and hylem sheet block obtained from item No. 616 above complete all as specified and as directed. |
| 610 | S&FAir termination, single pointed aluminium rod 12mm dia and 300mm long and fixed complete all as specified and as directed. |
| 611 | Fixing only of Air termination, single pointed aluminium rod 12mm dia and 300mm long and fixed obtained from item No. 607 above complete all as specified and as directed. |
| 612 | S&FTest terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 nos 125mm long hexogonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed. |
| 613 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip 32 x 6mm (up to 7.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of soil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one all as specified and directed and tested on completion |
| 614 | S&F GI strip of size 32x6mm for lightning conductor laid in trench / floor including necessery clamps, nuts, bolts,insulator and hylem sheet block complete all as specified and as directed. |
| 615 | Taking out after disconnectIon of existing LT panel any make model and capacity from the exisiting location with complete demolition of existing plinth/ foundation of LT panel including cleaning of site complete all as specified and as directed. |
| 616 | Taking down unserviceable XLPE Cable and making good disturbed surface complete all as specified and directed. |
| 617 | Supply and laying or fixing or passing through pipe, XLPE 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheating of PVC tape armoured with galvanized steel wire or tape and overall PVC Sheathed 16 Sqmm nominal cross section having 4 core complete all as specified and as directed. |
| 618 | S&F GI Tube light grade 40 mm dia with all fittings fixed to walls and ceiling or laid in floors for cable protection all as specified and directed. |
| 619 | LT Cubical Panel board CPRI approved made out of CRCA sheet 2.0 mm thick indoor Compartmenatal Type totally enclosed , Dust and vermin proof with front opening, hinged doors with projected raised platform of suitable size with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc made of rust proof material including all as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 630 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following :-Incoming:[a] MCCB AC 3 Phase 415 V, 50Hz 4 pole,400 A, breaking capactiy 36kA, Ics=100% Icu with adjustable type thermal and magnetic setting relays - 01 No.Outgoing:[a] MCB AC 3 Phase,415 V, 50Hz 4 pole, 63 A breaking capacity 10 kA with adjustable type thermal and magnetic setting relays - 13 Nos.(11 Nos TPN DB + 2 Nos Spare)[b] Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs [c] LED indicating lamps with colour Red, Yellow, Blue - 03 Sets (d) MCB SPN 20 Amps -2 Nos |
| 620 | S & F Hot- Dip Galvanised Cable tray of size 75mm depth, 300mm width and 2mm thick (14 SWG) and standard length for fixing to wall including tee, cross, horizontal/vertical bends and reducer as required for fixing or arrangement of cables in side the cable tray with zip ties such as electrical cable after taking out of cables from existing conduits of any make and sizes and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed. Make: MEM/OBO/Legrand |
| 621 | S & F Galvanised iron Coupler plate of size 75mm including necessary hardware work complete all as specified and directed. Make: MEM/OBO/Legrand Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender