Tender For Provn Of Kote And Amn Store Alongwith Guard Room & Single Jcos Living Accommodation Under Ge 862 Ews
Tender Overview
Project Description
Tender for Provn Of Kote And Amn Store Alongwith Guard Room & Single Jcos Living Accommodation Under Ge 862 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 2 | Construction of building block for Kote complete all as shown on drawings and as specified. |
| 3 | Construction of building block for Small Arms Amn Store complete all as shown on drawings and as specified. |
| 4 | Construction of building block for Guard Rest Room complete all as shown on drawings and as specified. |
| 5 | Construction of building block for Santry Post complete all as shown on drawings and as specified. |
| 6 | Construction of building block for 08 x single JCO living accn complete all as shown on drawings and as specified. |
| 7 | Construction of building block (single row & 6 bays) for 4 x Car parking & 4 x Scooter shed for 8 x JCOs with ramp/apron, plinth protection complete all as shown on drawings and as specified. |
| 8 | Total Amount of Sch 'A' Part - II (Site Clearance and Development Work) |
| 9 | Total Amount of Sch 'A' Part - III (Internal Water Supply Work) |
| 10 | Total Amount of Sch 'A' Part - IV (Sec-I) (Internal Electric Supply Work) |
| 11 | Total Amount of Sch 'A' Part - V (Plumbing Work) |
| 12 | Total Amount of Sch 'A' Part - VI (Area Drainage Work) |
| 13 | Total Amount of Sch 'A' Part - VII (Protective Work) |
| 14 | Total Amount of Sch 'A' Part - VIII (Sec-I) (Sewage Disposal Work) |
| 15 | Total Amount of Sch 'A' Part - IX (Road, Path and Hard Standing Work) |
| 16 | Total Amount of Sch 'A' Part -X (External Water Supply Work) |
| 17 | Total Amount of Sch 'A' Part -XI (Sec-I) (External Electric Supply Work) |
| 18 | Total Amount of Sch 'A' Part -XII (Sec-I) (Lghtening Protection Work) |
| 19 | Total Amount of Sch 'A' Part -XIII (Sec-I) (Hot Water Supply Work) |
| 20 | Total Amount of Sch 'A' Part -XIV (Sec-I) (Fencing Work) |
| 21 | Sch 'A' Part - IV (Sec-II) (Internal Electric Supply Work) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 22 | Point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20mm dia medium grade (MMS) and all accessories are concealed in walls / roofs / floors / ceiling etc; including modular metal flush box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick including modular top cover plate as per numbers of switch modules for fixing of modular switches, sockets, fan regulators, red colour indicator, blank plates etc. as approved colours and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Note No1: All necessary accessories such as modular steel box, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used of same make/brand only. Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes. |
| 23 | All as per Item No. 15.01 here-in-before above but One light /fan point controlled by one switch on way |
| 24 | All as per Item No. 15.01 here-in-before above but one socket out let 5A point controlled by one switch one way on independent switch board. |
| 25 | All as per Item No.15.01 here-in-before above but one socket outlet 5A point controlled by one switch one way on same switch board. |
| 26 | All as per Item No. 15.01 here-in-before above but here-in-before but point wiring with 2.5sqmm for socket outlet 15A point controlled by one switch. |
| 27 | LED bulb 7/9 & 10 watts, 240 volts, 50Hz, pin type suitable for lamp holder, complete all as specified and as directed. |
| 28 | Street light bracket made out of 40mm dia, medium grade GI pipe of 1.2m length, both end hole for fixing street light/security light fitting on Steel tubular pole including MS clamps, back plates fabricated from structural steel section 50mmx6m, including nuts, bolts, washers, welding cold or hot, drilling of holes for bolts, in any shape or size including two coats of aluminium paint over a coat of red oxide primer after preperation of steel surfaces, complete all as specified and directed. |
| 29 | Sub main wiring with two run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm as earth continuity conductor connected to commen earth dolly complete all as specified and directed.Note No.2: Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes. |
| 30 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including medium grade GI protection pipe 15mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed. (Contd.../) |
| 31 | Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge. |
| 32 | Sch 'A' Part-VIII (Sec-II) (Sewage Disposal Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 33 | Construction of septic tank for 10 users (Brick construction) complete all as shown on drg No. CEUZ /TD-1585/2021 sheet 1/4 to 4/4 and as specified. |
| 34 | Construction of soakage well (Brick construction) 1.8m dia and 3.0m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. |
| 35 | Sch 'A' Part-XI (Sec-II) (External Electric Supply Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 36 | Supply, installation, commissioning and testing of cubical type LT panel, weather proof panel board, factory made, dust and vermi proof, powder coated, outdoor type, IP 65, double door shutter, made out of CRCA 3.15mm thick sheet for outer shell and 2.00mm thick sheet for inner shell with angle iron (50x50x6)mm and 'T' section with front openable double door shutter and rear opening complete with locking arrangements, floor mounting type with 200 amp rated Aluminium bus bar mounted on epoxy/porcelain insulators in totally enclosed chamber, suitable for 3 phase, 4 wire system, 415V, 50Hz, AC supply, prewired system with suitable copper wire PVC insulated with all control accessories and suitable glands etc; including PCC work, 0.6 mtr above ground level grouting etc; complete all as specified and directed and space for provisioning followings:- (Contd.../) |
| 37 | INCOMER MCCB(i) 4 pole MCCB 63 A, 50Hz, 415V with rupturig capacity 25 KA- 01 No.OUTGOING MCCB(i) TPN, MCB 32 A, 50 Hz, 415V with with rupturig capacity 25 KA- 01 No.(ii) MCB, SPN, 16A, 50 Hz, 230V- 04 No.(iii) MCB, SPN, 10A, 50 Hz, 230V- 04 No.(iv) Digital voltmeter (0-415) & Digital Ammeter (0-100) A with suitable CTs- 01 No.(v) LED phase indication lamps RYB -01 set.(vi) Internal wiring with PVC insulated copper conductor multi stranded cable 1100V grade including painting etc; |
| 38 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI medium grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. (Contd.../) |
| 39 | Note: -(i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge. |
| 40 | Street light bracket made out of 32mm dia, medium grade GI pipe of 1.2m length, bend to shape 120 degree, both end hole for fixing street light/security light fitting on steel tubular pole including MS clamps, back plates fabricated from structural steel section 32mmx3mm, including nuts, bolts, washers, welding cold or hot, drilling of holes for bolts, in any shape or size including two coats of aluminium paint over a coat of red oxide primer after preperation of steel surfaces, complete all as specified and directed. |
| 41 | Earth work in excavation by mechanical means Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 3m, including getting out in all kind of soil (the excavated soil) and disposal of surplus excavated soil, within a lead of 50m complete all as specified and directed.Note:- Contractor may at his discretion use any means for excavation and width required at site. However payment shall be made for authorized width only as defined in preamble para 3.2.3 to section 3 of MES SSR Part-II. |
| 42 | Sch 'A' Part-XII (Sec-II) (Lingtening Protection Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 43 | Earthing complete with copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to copper earth strip of size (20x3)mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. (Contd.../) |
| 44 | Note:- (i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge. |
| 45 | Sch 'A' Part-XIII (Sec-II) (Hot Water Supply Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 46 | Electric water heater, storage type steel body with glass coated insulated heating element, copper tank of 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc; complete all as specified and as directed. |
| 47 | Sch 'A' Part-XIV (Sec-II) (Fencing Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 48 | Punched tape concertina coil as per latest IS 6745-1972 with galvanised coating and punched type material as per IS deep drawn quality with galvanised coating having medium barbs fixed in position and secured to fence posts/straining Y- arm stretched to a length so as to achieve 600mm dia as in fencing including fixing with special galvanised fasteners such as J clips, C clips, U clips fixed at any height of security fence including necessary scaffolding complete all as directed.Size of Coil: 600mm dia and 2.5mm core wire thick.Type of strip: Heavy galvanised conforming to IS 1730 (1989).Type of core wire: Heavy galvanised conforming to IS 280-2006. Zinc coating to strip : 200GSM/SqmmZinc coating to line wire: 18 micronsTensile strength of wire: 1620 N/Sqmm.Weight: 9.00 Kg/per coil (± 5% tolerance).Stretchable length of each coil: 6m. Type of clip: Steel grade 'A' as per IS 2060 finished hot dip galvanised 20 micron.Steel strip: Width -19mm and thickness 0.5mm |
| 49 | Sch 'A' Part - XIII (Misc Items of work) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 50 | Hoter Siren WorkFire Alarm sounders/Sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 DB measured at 1.5m with sound output Variation of + 5 DB 500m range complete all as specified and directed. |
| 51 | Summer Appliances WorkSupply & fixing of desert cooler of electric driven (single phase), having nominal air flow capacity of 400 Cum per hour steel body including angle iron stand for fixing, complete all as specified and directed. |
| 52 | Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed and joint with adhesive, taflon tape etc; for 15mm bore of pipe complete all as specified and directed. |
| 53 | Brass CP wall central hole basin mixer for mixing hot & cold water screwed down for iron pipe and fixed and joint with adhesive, taflon tape etc; for 15mm bore of pipe complete all as specified and directed. |
| 54 | Deduction to be made from BOQ for Sch 'A' Part -II (Schedule of credit) Amount during AOC.Note: Tenderers shall not quote for this schedule. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender