Tender For Provn Of Otm Accn And Stores For Asc Supply Type A (Ph-I) At Damdim, Bagrakote Under Ge Sevoke Road
Tender Overview
Project Description
Tender for Provn Of Otm Accn And Stores For Asc Supply Type A (Ph-I) At Damdim, Bagrakote Under Ge Sevoke Road
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Nov-2026 | Date Corrigendum - 1 | Date | 25-Nov-2026 |
| 2 | 10-Nov-2026 | Revised BoQ - 1 | BOQ | 25-Nov-2026 |
| 3 | 10-Nov-2026 | Amendment - 1 with Revised Drgs | Other | 25-Nov-2026 |
| 4 | 10-Nov-2026 | Revised BoQ - 1 | BOQ | 21-Nov-2026 |
| 5 | 10-Nov-2026 | Amendment - 1 with Revised Drgs | Other | 21-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | BUILDINGS & STRUCTURE (Sch 'A' PART-I) |
| 2 | Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 14,45,99,000.00 inserted by the MES in Schedule ‘A’ Part-I. |
| 3 | EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II) |
| 4 | Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.47,52,478.74 inserted by the MES in Schedule ‘A’ Part-II. |
| 5 | INTERNAL WATER SUPPLY (Sch 'A' PART-III) |
| 6 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.5,54,748.16 inserted by the MES in Schedule ‘A’ Part-III. |
| 7 | INTERNAL ELECTRIFICATION (Sch 'A' PART-IV) |
| 8 | Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 30,04,557.51 inserted by the MES in Schedule ‘A’ Part-IV. |
| 9 | ROAD, PATH & CULVERT (Sch 'A' PART-V) |
| 10 | Lump sum price worked out by the Contractor for “(ROAD, PATH & CULVERT )” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 87,43,456.52 inserted by the MES in Schedule ‘A’ Part-V. |
| 11 | SEWAGE DISPOSAL (Sch 'A' PART-VI) |
| 12 | Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 17,51,287.39 inserted by the MES in Schedule ‘A’ Part-VI. |
| 13 | AREA DRAINAGE (Sch 'A' Part-VII) |
| 14 | Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 82,97,802.14 inserted by the MES in Schedule ‘A’ Part-VII. |
| 15 | FENCING, GATE & COMPOUND WALL (Sch 'A' Part-VIII) |
| 16 | Lump sum price worked out by the Contractor for “(PERIMETER FENCING)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 3,34,021.74 inserted by the MES in Schedule ‘A’ Part-VIII. |
| 17 | EXTERNAL WATER SUPPLY (Sch 'A' Part-IX) |
| 18 | Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 5,41,835.93 inserted by the MES in Schedule ‘A’ Part-IX. |
| 19 | EXTERNAL ELECTRIFICATION (Sch 'A' PART-X) |
| 20 | Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 60,50,853.61 inserted by the MES in Schedule ‘A’ Part-X. |
| 21 | LIGHTNING PROTECTION (Sch 'A' Part-XI) |
| 22 | Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,87,781.00 inserted by the MES in Schedule ‘A’ Part-XI. |
| 23 | HOT WATER SUPPLY (Sch 'A' PART-XII) |
| 24 | Lump sum price worked out by the Contractor for “(HOT WATER SUPPLY)” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.1,71,981.47 inserted by the MES in Schedule ‘A’ Part-XII. |
| 25 | DG SET (Sch 'A' Part-XIII) |
| 26 | Lump sum price worked out by the Contractor for “(DG SET)” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 15,145.80 inserted by the MES in Schedule ‘A’ Part-XIII. |
| 27 | COOLING APPLIANCE (Sch 'A' Part-XIV) |
| 28 | Lump sum price worked out by the Contractor for “(COOLING APPLIANCE)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,89,386.32 inserted by the MES in Schedule ‘A’ Part-XIV. |
| 29 | SEWAGE TREATMENT PLANT (Sch 'A' Part-XV) |
| 30 | Lump sum price worked out by the Contractor for “(SEWAGE TREATMENT PLANT)” as listed in Schedule ‘A’ Part-XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 15,145.80 inserted by the MES in Schedule ‘A’ Part-XV. |
| 31 | DEMOLITION & DISMANTLING (Sch 'A' Part-XVI) |
| 32 | Lump sum price worked out by the Contractor for “(DEMOLITION & DISMANTLING) ” as listed in Schedule ‘A’ Part-XVI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 6,69,253.75 inserted by the MES in Schedule ‘A’ Part-XVI. |
| 33 | MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XVII) |
| 34 | INTERNAL ELECTRIFICATIONS & F modular type, 3-pin, 20 A, 250 V socket outlet conforming to IS 1293, complete with 20 A, single-pole (SP), Type C, 230 V AC MCB having a minimum breaking capacity of 6 kA, conforming to the applicable IS/IEC 60898-1 standard, including modular box, cover plate, connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 35 | S & F engagement indicator light, LED type, rated 230 V AC, 50 Hz, with power consumption not exceeding 2 W, for visual indication of the ON/energised status of the electrical equipment or circuit, complete with insulated housing, suitable mounting arrangement, terminals, internal wiring, connections and all necessary accessories, including fixing, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 36 | S & F illuminated push button, flush-type, momentary, spring-return, LED illuminated, rated 230 V AC, 50 Hz, with minimum NO (Normally Open) contact, suitable for start/ON operation, complete with contact block, integral LED indicator, insulated housing, mounting arrangement, terminals, internal wiring, connections and all necessary accessories, including fixing, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 37 | S & F modular type, 1-module, RJ-11 telephone socket outlet with protective shutter, suitable for standard telephone connection, complete with modular faceplate, compatible mounting box, terminals and necessary connections, including fixing, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 38 | S & F modular type, 1-module, co-axial TV socket outlet, 75 Ohm impedance, suitable for standard TV antenna/cable TV connection, complete with compatible modular faceplate, mounting box, co-axial connector, terminals and all necessary accessories, including fixing, cable termination, connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 39 | S & F single-pole and neutral (SPN), modular type, double-door, 6-way, metallic distribution board, conforming to IEC 61439-3, suitable for flush or surface mounting, with provision for DP RCCB/RCBO/isolator/MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A rated copper busbar, fully shrouded neutral bar, earth bar, wire set, cable ties for cable management and pre-fitted masking sheet, with minimum IP43 degree of protection and IK09 impact resistance, complete with all necessary internal connections, mounting accessories and hardware, all as specified in IS 732:2019 and directed by the Engineer-in-Charge.**NOTE:** DP RCCB/RCBO/isolator/MCB as incomer and SP MCBs as outgoing shall be measured and paid for separately. |
| 40 | S & F 25 A, 230 V AC, 50 Hz, double-pole (DP), Type C, miniature circuit breaker (MCB), conforming to IS/IEC 60898-1, with rated short-circuit breaking capacity (Icn) of 10 kA, sliding bottom clamp, colour-coded ON/OFF indication on operating dolly, IP20-protected lower terminals with bi-connect facility and sliding shutters, complete with fixing, connections and all necessary accessories, all as specified in IS 732:2019 and directed by the Engineer-in-Charge. |
| 41 | S & F 16 A, 230 V AC, 50 Hz, double-pole (DP), Type C, miniature circuit breaker (MCB), conforming to IS/IEC 60898-1, with rated short-circuit breaking capacity (Icn) of 10 kA, sliding bottom clamp, colour-coded ON/OFF indication on operating dolly, IP20-protected lower terminals with bi-connect facility and sliding shutters, complete with fixing, connections and all necessary accessories, all as specified in IS 732:2019 and directed by the Engineer-in-Charge. |
| 42 | S & F load line distribution board, TPN, vertical, 6-way, double-door type, metallic enclosure, suitable for semi-flush wall mounting, complete with incoming 4-pole MCCB, suitably rated copper busbars, neutral link, earth bar, blanking plates, internal wiring, cable terminals, mounting accessories and all necessary hardware, conforming to applicable requirements of IEC 61439-3, complete in all respects, all as specified and directed by the Engineer-in-Charge.**NOTE:** Outgoing MCBs shall be measured and paid for separately. |
| 43 | S & F load line distribution board, TPN, vertical, 8-way, double-door type, metallic enclosure, suitable for semi-flush wall mounting, complete with incoming 4-pole, 63 A, 415 V AC, 50 Hz MCCB having a minimum breaking capacity of 25 kA at 415 V AC, suitably rated trip unit, 100 A rated copper busbars, suitably rated neutral link, earth bar, blanking plates, internal connections, cable terminals, mounting accessories and all necessary hardware, conforming to applicable requirements of IEC 61439-1 and IEC 61439-3, complete in all respects, all as specified and directed by the Engineer-in-Charge.NOTE: Outgoing MCBs shall be measured and paid for separately. |
| 44 | S & F 63 A, 4-pole, moulded case circuit breaker (MCCB) with thermal-magnetic trip unit (TMD), suitable for 3-phase, 415 V AC, 50 Hz electrical supply, conforming to IEC 60947-2, with adjustable overload protection (Ir: 0.7–1.0 × In), adjustable short-circuit protection (Isd: 5–10 × Ir), inbuilt instantaneous protection with double-break, roto-active contact system, earth-fault protection, compression-lug connectors and all necessary mounting and connection accessories, having rated ultimate short-circuit breaking capacity (Icu) of 16 kA and rated service short-circuit breaking capacity (Ics) equal to 100% of Icu, complete with fixing, connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 45 | M & L for 1.1 kV grade, XLPE insulated, 3-core, 1.5 sq mm, aluminium conductor, armoured power cable, conforming to IS 7098 (Part 1), with stranded compacted aluminium conductors conforming to IS 8130, PVC inner sheath, galvanised steel strip/wire armouring and PVC Type ST-2 outer sheath conforming to IS 5831, complete with laying, jointing, termination and all necessary accessories, as specified and directed by the Engineer-in-Charge. |
| 46 | S & F 24 W, 1 ft × 1 ft, LED surface-mounted panel light, suitable for 230 V AC, 50 Hz supply, having a luminous efficacy of not less than 100 lm/W, luminous flux of not less than 2,400 lumens, power factor ≥ 0.90, total harmonic distortion (THD) ≤ 20%, correlated colour temperature (CCT) of 4000–6500 K and colour rendering index (CRI) ≥ 80, with an input voltage range of 140–270 V AC, complete with high-efficiency LED driver, diffuser, housing and manufacturer-approved surface-mounting frame or metal brackets for direct ceiling mounting, including suitable fasteners, electrical connections, testing and commissioning, conforming to applicable requirements of IS 16102 (Part 1) and IS 16102 (Part 2), all as specified and directed by the Engineer-in-Charge. |
| 47 | S & F 9 W/10 W LED bulkhead light, suitable for 230 V AC, 50 Hz supply, having luminous efficacy not less than 100 lm/W, luminous flux not less than 900 lumens for 9 W and 1,000 lumens for 10 W, input voltage range of 140–270 V AC, power factor ≥ 0.90, colour rendering index (CRI) ≥ 80 and correlated colour temperature (CCT) of 4000–6500 K, complete with LED driver, impact-resistant diffuser, robust housing, suitable surface-mounting arrangement, terminals, internal wiring and all necessary accessories, conforming to applicable requirements of IS 10322 (Part 5/Sec 1) and IS 16102 (Part 1), including fixing, connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 48 | S & F 12 W LED surface-mounted downlight, suitable for 230 V AC, 50 Hz supply, having luminous efficacy not less than 100 lm/W, luminous flux not less than 1,200 lumens, input voltage range of 140–270 V AC, power factor ≥ 0.90, colour rendering index (CRI) ≥ 80 and correlated colour temperature (CCT) of 4000–6500 K, complete with high-efficiency LED driver, aluminium or equivalent heat-dissipating housing, opal diffuser, surface-mounting arrangement, terminals, internal wiring and all necessary accessories, conforming to applicable requirements of IS 16102 (Part 1) and IS 16102 (Part 2), including fixing, connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 49 | S & F 5 W LED mirror light, suitable for 230 V AC, 50 Hz supply, having luminous efficacy not less than 100 lm/W, luminous flux not less than 500 lumens, input voltage range of 140–270 V AC, power factor ≥ 0.90, colour rendering index (CRI) ≥ 80 and correlated colour temperature (CCT) of 4000–6500 K, complete with LED driver, corrosion-resistant housing, opal diffuser, suitable wall/mirror mounting arrangement, terminals, internal wiring and all necessary accessories, conforming to applicable requirements of IS 16102 (Part 1) and IS 16102 (Part 2), including fixing, connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 50 | S & F 5 W LED study light, suitable for 230 V AC, 50 Hz supply, having luminous efficacy not less than 100 lm/W, luminous flux not less than 500 lumens, input voltage range of 140–270 V AC, power factor ≥ 0.90, colour rendering index (CRI) ≥ 80 and correlated colour temperature (CCT) of 4000–5000 K, complete with LED driver, glare-reducing diffuser, housing, adjustable or fixed mounting arrangement as required, terminals, internal wiring and all necessary accessories, conforming to applicable requirements of IS 16102 (Part 1) and IS 16102 (Part 2), including fixing, connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 51 | S & F 5 W, 2-star energy-efficient LED lamp, having luminous flux not less than 501 lumens, suitable for 230 V AC, 50 Hz supply, with B22 bayonet-cap base, complete with a B22 lamp holder made of high-grade, flame-retardant, heat-resistant engineering plastic, fitted with brass electrical contacts and suitable terminals, rated for 230 V AC and compatible with the lamp, conforming to applicable safety requirements, including fixing, connections, testing and all necessary accessories, all as specified and directed by the Engineer-in-Charge. |
| 52 | S & F wall-mounted fan, 400 mm sweep, steel body, single-phase, 230 V AC, 50 Hz, with 3 blades, rated input power not exceeding 60 W, having air delivery of not less than 90 CMM, complete with single-phase AC motor, protective frame, adjustable louvers, wall-mounting bracket, compatible speed regulator, necessary wiring, fasteners and all accessories, conforming to applicable requirements of IS 374, including fixing, electrical connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 53 | Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 17.21 to 17.22 |
| 54 | The BUILDING PANEL shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 100A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection.[B] INCOMING[i]80A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. On hrs & interrupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set |
| 55 | [C] OUTGOING[i]63A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos (MDB#A & 1-SPARE)[ii]32A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 04 Nos (FMDB#B, C, D & SPARE)[iii]16A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 1P MCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos (SECURITY LIGHT)[iv] LED phase indicators (Red, Yellow, Blue)- 07 Set |
| 56 | INTERNAL WATER SUPPLYS&F 15 mm bore, 3-in-1 type, single lever wall mixer for hot and cold water, wall mounted, with provision for connection to hand shower and overhead shower including hand shower, complete with 115 mm long bend pipe, connecting legs and wall flanges, manufactured from high-quality heavy-duty brass with durable corrosion-resistant chromium-plated finish, robust construction, smooth and leak-proof operation, suitable for the working pressure and temperature of the system, conforming to latest applicable IS/BIS standards, complete with all necessary fittings, connections, fixing accessories, testing and commissioning, complete in all respects as specified and directed. |
| 57 | S&F 15 mm bore, heavy-duty fancy type chromium plated (CP) basin inlet connection/angle valve, made of high-quality cast copper alloy/brass, screwed type, suitable for high-pressure water supply, with accurately machined threaded ends suitable for iron pipe or union connections, durable and uniform chromium plating, robust and leak-proof construction, complete with all necessary washers, seals, nuts, fixing accessories and connections, conforming to the latest applicable IS/BIS standards, including testing for leakage and proper operation, complete in all respects as specified and directed. |
| 58 | S&F 15 mm bore, two-way, heavy-duty fancy type screw-down bib cock, chromium plated, with crutch/butterfly handle and wall flange, suitable for high-pressure water supply and screwed connection to iron pipe, manufactured from good quality cast copper alloy/brass, with durable and uniform chromium-plated finish, robust and leak-proof construction, conforming to IS 781:1984 and IS 8931, complete with all necessary washers, seals, wall flange and fixing accessories, including installation, testing for leakage and proper operation, complete in all respects as specified and directed. |
| 59 | SEWAGE DISPOSALM&L for laying 150 mm internal dia Double Wall Corrugated Polyethylene (DWCPE) sewer pipe, SN-8 stiffness class, conforming to IS 16098 (Part 1), including trench preparation, bedding, alignment and laying to required line and gradient, jointing with manufacturer/OEM recommended compatible couplers and sealing rings, installation strictly in accordance with the pipe manufacturer's/OEM's recommended laying and jointing procedure, including testing, complete with all necessary materials, labour, tools, tackles, accessories and equipment, complete in all respects as specified and directed. |
| 60 | M&L for laying 200 mm internal dia Double Wall Corrugated Polyethylene (DWCPE) sewer pipe, SN-8 stiffness class, conforming to IS 16098 (Part 1), including trench preparation, bedding, alignment and laying to required line and gradient, jointing with manufacturer/OEM recommended compatible couplers and sealing rings, installation strictly in accordance with the pipe manufacturer's/OEM's recommended laying and jointing procedure, including testing, complete with all necessary materials, labour, tools, tackles, accessories and equipment, complete in all respects as specified and directed. Please Enable Macros to View BoQ information |
| 61 | M&L for laying 200 mm internal dia Double Wall Corrugated Polyethylene (DWCPE) sewer pipe, SN-8 stiffness class, conforming to IS 16098 (Part 1), including trench preparation, bedding, alignment and laying to required line and gradient, jointing with manufacturer/OEM recommended compatible couplers and sealing rings, installation strictly in accordance with the pipe manufacturer's/OEM's recommended laying and jointing procedure, including testing, complete with all necessary materials, labour, tools, tackles, accessories and equipment, complete in all respects as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents