Tender for Provn Of 02 X Toilet Block Consisting Of 02 X Wc With Septic Tank And Soakage Well At Watchi Cob Against Job No 01/Rev/12S/2026-27 Under Age B/R (P) Of Ge 861 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in Hard/ Dense soil complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in Soft/ Loose soil complete all as specified and as directed by Engineer-in- charge. |
| 3 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil ( Except soft / Loose soil ) complete all as specified and as directed by Engineer-in- charge. |
| 4 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in any type of soil complete all as spefied and as directed by Engineer-in-Charge. |
| 5 | Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as spefied and as directed by Engineer-in-Charge. |
| 6 | Material & Labour for Hardcore of broken stone or boulders ,gauge exceeding 63mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Material & Labour for PCC 1:4:8 , Type - D2, using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. |
| 9 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. |
| 10 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. |
| 11 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Slabs supported on walls,beams and columns infloors,roofs, landings, balconies,canopies, deck slabs and inshelves and the like Slabs supported on walls,beams andcolumns in floors,roofs, landings, balconies,canopies, deck slabs and inshelves and the like complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. |
| 12 | Material & Labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Material & Labour for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Material & Labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Material & Labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, in square, rectangular or polygonal on rough finished surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Material & Labour for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. on flat rough finished surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Material & Labour for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) on rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Material & Labour for Brickwork with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Material and labour Brickwork with sub class 'B' old size burnt clay bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge. |
| 20 | Material & Labour for 100 mm thick PCC 1:4:8 ,Type-D2 ,using 40mm graded stone aggregates as in sub base of flooring complete all as specified and directed by Engineer-in-Charge. |
| 21 | Material and labour for 75 mm thick PCC (1:3:6) Type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection / path etc. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge |
| 22 | Material and labour for Rendering 15mm thick in Cement Mortar 1:4 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material and labour for Rendering 10mm thick in Cement Mortar 1:6 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material and Labour for Setting coat of 3mm thick of CM (1:2) ,trowelled to even and smooth finish over rendering 15mm thick in CM 1:4 on fair faces of brickwork finished surface even and smooth with using Liquid water proofing compound complete all as specified and directed by Engineer-in-Charge. The labour element for providing of Liquid water proofing is included in this item . Nothing shall be paid extra on this account. However Liquid water proofing shall be measured and paid seperately under appropriate item of Schedule,A, BoQ as supply only. |
| 25 | Material & Labour for Non skid ceramic coloured joint free tiles , thickness 7mm to 8mm thick (square/ rectangular), colour as approved by Engineer-in-charge area of each tiles exceeding 0.06 Sqm but not exceeding 0.11Sqm in floor etc set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 26 | Material & Labour for Glazed Coloured Ceramic tiles , size 300mm x 200mm /250/ 450mm /x 350mm x 7mm to 8mm thick, colour as approved by Engineer-in-charge as in vertical surfaces set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material and labour for preparation of new surface of walls, with and including two coats of cement base paint ,over with and including one coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material and labour for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 29 | Supply & Fixing Mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410 -W (Gde- E- 250) quality-A including distance pieces, cleats etc. complete all as speicied and as directed by Engineer in charge. |
| 30 | Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 31 | Supply & Fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 32 | Material & Labour for preparation of newely steel surfaces of any description, over 10 cm in width or girth or otherwise described , with and including applying two coat of syntheic enamal paint over with and including one coat of red oxide zinc chrome primer complete all as spefied and as directed by Engineer-in-Charge. |
| 33 | Supply & Fixing Box type steel ventilator with top hung shutters including hinges, steel handle, steel peg stay complete with glazing bar dovetailed/welded complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and Fixing 3mm thick sheet glass of ordinary quality and glazing with oil putty in square , not exceeding 0.50 Sqm each in pane complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply & Fixing Solid PVC door frame of size 50mm x 47mm made out of 5 mm single side prelam PVC sheet reinforced with MS square tube manufactured as per SSR Part-I specifications and drawings complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply & Fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and Fixing Butt hinges size of 100mm , medium weight cold rolled mild steel (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and Fixing 150mm long aluminium anodised barrel tower bolts of extruded section and fixed (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and Fixing 150 mm long Extruded aluminium alloy handles, cast type,anodised (ISI Marked ) as specified and directed by Engineer-inCharge. |
| 40 | Supply & Fixing water closet vitreous china squatting pan, Orissa pattern size 580mm x 440mm white with integral foot rests with and including provision of lime concrete bedding with and including 110mm bore PVC (SWR)'P' Trap and connection to drain and to flushing pipe anti symphonage pipe complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and Fixing PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle , with and including brackets, with and including 32 mm dia flush pipe of polyethylene of low or high density of PVC complete all as specified and as directed by Engineer-in- charge. |
| 42 | Supply and Fixing in Vitreous china wash hand basin, Vitreous china white, flat back, size of 630mm x 450 mm with Mild steel brackets, with and including cutting for and pinning in ends of brackets or erecting stand, with and including waste fittings of brasschromium plated ,with and including 32mm dia PVC waste pipe of required length complete all as specified and directed. as directed by Engineer-in-Charge. |
| 43 | Supply and Fixing 15mm bore Pillar tap fancy type Chromium Plated , (ISI marked) cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and fixing 15mm bore bib tap cast copper alloy, chromium plated, fancy type (ISI marked) with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge. |
| 45 | Supply and fixing 15 mm bore stop valve , Chromium Plated, cast copper alloy (ISI marked) screwed down both ends for iron pipe or for brass ferrule , high pressure with crutch or butterfly handle ,long shank and cup concealed type complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply & Fixing 15mm bore PVC connection with PTMT nuts of 600mm long complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply and fixing soap dish vitreous china white size 160mm x 160mm x 90mm approx all complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply & Fixing 15mm bore GI tubing medium grade with all new fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply & Fixing 20mm bore GI tubing medium grade with all new fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply & Fixing 20mm bore GI tubing medium grade with all new fittings laid in trenches complete all as specified and directed by Engineer-in-Charge. Note: Excavation and earth work shall be measured and paid seperately under appropriate items of schedule 'A' BoQ. |
| 51 | Supply and fixing 20mm bore Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for iron pipes complete all as specified and as directed by Engineer-in-charge. |
| 52 | Supply & fixing Rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position with and including Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in-charge. Note: The rate of 20mm bore ball valves, high pressure of PTMT is included in this iterm and nothing shall be paid extra on this account. |
| 53 | Supply and fixing PVC (SWR) 110 mm bore pipes single socketed ,Type-B (ISI Marked ) fixing with using adhesive, in any length laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.Note: Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule of BoQ. |
| 54 | Supply and fixing 110 mm bore PVC (SWR) Bends in any radius , Type-B (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 55 | Supply & Fixing 110 mm bore PVC(SWR) junction double (doubleT) equal or unequal, Type-B (ISI Marked) complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply and Fixing 110mm PVC (SWR) vent cowl Type-B (ISI Marked) complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply and fixing 600mm x 450mm size bevelled edge mirror selected quality 5mm thick glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including aluminium frame / beading alround made of aluminium channel, complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply & Fixing PVC (SWR) floor trap of , Type-B (ISI Marked ) ,75mm bore with grating including jointing to waste pipe fixed in cement concrete 1:2:4 Type B-1, using 20mm stone aggregates complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply only Liquid water proofing compound complete all as specified and as directed by Engineer-in-Charge. |
| 60 | Material & Labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregates as in lintel upto 1.5m clear span, cills, steps; seismic and other similar bends, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and thelikeincluding weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-Charge. |
| 61 | Material & Labour for Reinforced Precast cement concrete 1:2:4, Type B-1 , using 20 mm graded stone aggregates as in Cover Slabs for Manholes and similar article with plain face set in Cement Mortar 1:6 complete all as specified and directed by Engineer-in-Charge.NOTE :- Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. |
| 62 | Material and labour for PCC (1:3:6) typeC-2 using 40 mm graded stone aggregates as in concrete bed for drain pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested including form work complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm.(iii) Excavation , earth work , returning filling shall be measured and paid seperately under appropriate items of schedule 'A' BoQ. |
| 63 | Material and Labour for 150 mm bore RCC pipes Class NP-2 with socketed ends laid and jointed complete all as specified and directed by Engineer-in-Charge. |
| 64 | Material and Labour for Construction of soakage well of size 1.20 mtr dia x 3mtr effective depth includingearth work such as excavation in any type of soil, returning filling and removal of earth work , foundation in PCC 1:3:6 Type-C-1 using 20mm graded stone aggregates, Honey combing Brick massony built with burnt clay old size bricks ,Top ring made with RCC M-25 Design Mix ,intercepting chamber and screen made with burnt clay old size brick with cement mortar 1:4, RCC M-25 Design Mix cover slab , 150mm bore salt glazed stoneware interconnecting pipes , filled with brick bats compete all as shown in drawing No.CESZ/TD-36/ST/20 SHEET 1/2 AND 2/2 DATED 22-02-2020 |
| 65 | Supply and installation of LLDPE (Linear Low Density Polyethylene )Septic Tank of approved make of 20 user capacity, conforming to relevant specifications, including excavation in all types of soil,providing and laying 100mm thick Plain Cement Concrete 1:4:8 Type D-2, using 40mm graded stone aggregates as in bedding for placing the tank in position, connecting inlet and outlet pipes, filling around the tank with suitable material, and making good the disturbed surfaces complete in all respects as directed by the Engineer-in-Charge. Note: The rate of 100mm thick Plain Cement Concrete 1:4:8 Type D-2, using 40mm graded stone aggregates, excavation and earthwork , filling the suitable material and making good the disturbed surfaces is included in this item and nothing shall be paid extra on this account. |
| 66 | Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), in new PVC conduit complete with and including 1.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , drawn through with and including new PVC rigid conduit 20mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all new fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick ) and flush fixed with cement mortar 1:4 , 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover for switches 5Amp/6Amp , socket outlet 5Amp/6Amp and fan regulator, for light / fan point controlled by one way switch 5Amp / 6Amp, top cover fixed with brass screws & cup washers, with and including one single core 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. with and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge .Notes for serial item nos. 66.00 to 68.00 : (i) Switches one way 5 /6 Amp , , Switch Socket combination 5 /6 Amp and Switch Socket combination 15 1/6 Amp shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ. |
| 67 | All as per serial item No 64.00 of BoQ here-in-before but for Switch socket combination 2 in 1, 3 pin, 5 Amp on independent board controlled by one switch, complete all as specified and directed by Engineer-in-charge. |
| 68 | All as per srl item No 64.00 of BoQ here-in-before but 2.5 Sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked with and including one single core 2.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) as continues earth wire connected to earth dolly etc for Switch socket combination 2 in 1, 3 pin, 15 Amp independent board complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply and fixing Switch piano flush type 5/6 Amp single pole one way ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 70 | Supply & Fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal 240 volt (ISI Marked )complete all as specified and directed by Engineer-in-Charge. |
| 71 | Supply & Fixing Switch socket combination 2 in 1, 3 pin, 15 Amp flush type universal 240 volt (ISI Marked )complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply and fixing ceiling rose surface bakelite 65mm x 50mm three terminals ISI Marked complete all as specified and directed by Engineer-in-Charge. |
| 73 | Supply and fixing Lamp holder (Angular/Straight )ISI marked , insulated body , with back plate for batten fittings complete all as specified and directed by Engineer-in-Charge. |
| 74 | Supply and Fixing LED Lamp 10Watt ,230 Volt, AC Supply,, Energy efficien, long life complete all as specified and directed by Engineer-in-Charge.Notes :(a) Contractor has to furnish a replacement warranty of 02 years for LED Lamp from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. |
| 75 | Supply and Fixing Decorative ultra slim linear LED 20 Watt 4 Feet Long lighting fixture with extruded aluminium heat sink,environment friendly, Energy efficient , ready to use pack with and including LED Tube complete , with inbuilt electronic driver, PCB, Connector block complete all as per manufactureres instructions with and including connecting up with theree copper flexible cable from ceiling rose to fitting including connectiong up and fixed on with and including two nos.square box of required size complete all as specified and directed by Engineer-in-charge. Notes:(a) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 76 | Supply & Fixing LED Security street light fitting 35 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 77 | Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 8 way 230 V AC with 200 Amp rated copper bus bar, Double Door, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 78 | Supply and fixing MCB SP 06 to 32Amps , rupturing capacity not less than 10 KA 'C' curve 230 V AC, 50 Hz ,ISI Marked, with and including necessary attachment , thimbles etc. complete all as specified and directed by Engineer-in-charge. |
| 79 | Supply and fixing MCB SPN 32Amps , rupturing capacity not less than 10 KA 'C' curve 230 V AC, 50 Hz ,ISI Marked, with and including necessary attachment , thimbles etc. complete all as specified and directed by Engineer-in-charge. |
| 80 | Supply and fixing exhaust fan 300mm sweep PVC body with louver,240volts AC single phase,50Hz,ISI marked,including connection cable,nut bolt and other fixing material complete all as specified and directed by Engineer-in-Charghe. |
| 81 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 6 Sqmm 4.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 82 | Material and Labour for Cutting of existing CI / GI pipe line of 20mm to 50mm bore and inserting with and including NEW TEE of appropriate size and taping new connection with all accessories complete all as specified and as directed by Engineer-in-charge. Note: The rate of supply and fixing of NEW TEE of appropriate size is included in this item.Hence bidder shall be quoted his rates accordingly and nothing shall be paid extra on this account. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender