Tender For Establishment Of 33/11 Kv Ss With 1X8 Mva , 33/11 Kv Power Transformer And 4Nos 11 Kv Feeder Bay At Avatti In Cuddalore Edc In Villupuram Region Of Tnpdcl Under Turnkey Basis.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Nov 2026
21 days left
EMD
1.12 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cuddalore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Establishment Of 33/11 Kv Ss With 1X8 Mva , 33/11 Kv Power Transformer And 4Nos 11 Kv Feeder Bay At Avatti In Cuddalore Edc In Villupuram Region Of Tnpdcl Under Turnkey Basis.
BOQ
| Sl. No. | Item Description |
| 1 | Schedule I |
| 2 | Schedule II |
| 3 | GST Amount (Total GST Amount @18%) |
| 4 | 33KV CT (600-300-150/1A), outdoor type |
| 5 | 11KV CT (1200-600/1-1A), outdoor type |
| 6 | 11KV CT (400-200/1-1A), outdoor type |
| 7 | 33KV Potential Transformer with TC (Single phase unit) |
| 8 | 11KV Potential transformer with TC (Three phase unit) |
| 9 | 33KV Centre rotating AB switch without Support Structure |
| 10 | 11KV AB switch centre rotating without Support Structure. |
| 11 | Supply of reputed make long shackle 6lever Navtal lock with triplicate keys for AB switches and for any other purpose including the cost of ring and key token as directed by the field Engineer. |
| 12 | Supply of flexible copper tape 25x3sqmm /12mm rope for interlinking panel earthing and for any other purpose, on any sizes, including the cost of copper lugs at both ends as directed by the field Engineer |
| 13 | 33KV Lightning Arrester Station type |
| 14 | 11KV Lightning Arrester Station Type |
| 15 | 11KV Lightning Arrester Distribution Type |
| 16 | AC Panel for 33KV SS |
| 17 | 110 V DC annunciation panel Type B |
| 18 | 110V DC indoor C&R Panel for GC Breaker |
| 19 | 110V DC indoor C&R Panel for LV Breaker |
| 20 | 110 V DC indoor C&R Panel for Twin feeder |
| 21 | 110V, 120AH Battery set with stand |
| 22 | 110V, DC 24A, Battery charger |
| 23 | 14Core x 2.5 Sq.mm Copper cable armoured |
| 24 | 8Corex 4 Sq.mm Copper cable armoured |
| 25 | 4Core x 4 Sq.mm Copper cable armoured |
| 26 | 4Core x 2.5 Sq.mm Copper cable armoured |
| 27 | 2Core x 2.5 Sq.mm Copper cable armoured |
| 28 | 2CoreX16 sq.mm copper power cable |
| 29 | Zebra ACSR conductor |
| 30 | Supply of various types of hot dip galvanised fabricated steel structures confirming to IS 2062 Gr A at site as per the std.design/ Drawing, including Freight & Handling, Loading, unloading, Labour, machinery and Consumables and as directed by the field Engineer at the SS site. |
| 31 | 33 KV Four Pole structure (Incomer) |
| 32 | 33 KV Strung Bus structure |
| 33 | 33 KV Power Transformer Gantry structure |
| 34 | 33 KV AB switch structure (1.8 m centre) |
| 35 | 33 KV LAS Structure under Strung Bus (1.8 m centre) |
| 36 | 11 KV Feeder Bay structures with 4 Bays + 1 LV |
| 37 | 11 KV Station Transformer structure |
| 38 | Non-specfied hot dip galvanized structures for Extension, Alterations, and Deductions as per station requirement. |
| 39 | Heavy section using RSJ 250 x 125 mm /200X100mm |
| 40 | Light section (other than heavy section) |
| 41 | Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site. |
| 42 | 33 KV Breaker Platform |
| 43 | 11 KV Breaker Platform |
| 44 | Yard Fire Stand frame with top canopy cover |
| 45 | Battery Room Fire Stand |
| 46 | AC Junction Box fixing frame |
| 47 | 11 KV/433 V 100 KVA Station Transformer |
| 48 | 11 KV Horn gap fuse with insulator |
| 49 | Supply of 50mm Aluminium Bus bar |
| 50 | Supply of Fabricated main equipment board 2500 X 1500 mm out of 14 SWG M.S Sheet, alongwith painted MS Channels(100 x 50 MM) and MS Flat(65x65x6) (50x50x6) (50x6) and mounting the Board on to a Structure with all reuqired hardware. |
| 51 | Supply of 1000V/2000 MOhm Hand operated Meggar |
| 52 | Supply of Digital Multimeter as per IS standards |
| 53 | Supply & providing of Mechanical Foam type fire extinguishers with all accessories conforming to ISI Certification mark |
| 54 | 50 litre trolly mounted |
| 55 | 9 litre portable |
| 56 | Supply of Dry Chemical Powder type trolley mounted Cylindrical shape 25KG capacity fire extinguisher with initial charge & complete with rubber or braided hose, dry powder level indicator and all accessories confirming to the latest issue of ISI Certification mark |
| 57 | Supply of Dry Chemical Powder type Cylindrical shape 9/10 KG capacity fire extinguisher with initial charge & complete with rubber or braided hose, dry powder with level indicator and all accessories confirming to the latest issue of ISI Certification mark |
| 58 | Supply of Portable Dry Chemical Powder type cylindrical shape 5/6 KG capacity fire extinguisher wilth initial charge & complete with rubber or braided hose, dry powder with level indicator and all accessories confirming to the latest issue of ISI certification mark. |
| 59 | Supply of Fire/Water bucket of 10 lit capacity made out of 26Swg (0.46 mm) M.S.Sheet painted with white & red enamal paint in side & out side respectively bottom of bucket shall be ` U ` shapped out side of the bucket shall be written as Fire in English /Tamil in white enamal paint including cost of all materials. |
| 60 | Supply of Telescopic earth rod with copper wire 10 feet (SS type) as per IS Standard as directed by the field Engineer. |
| 61 | Supply of Discharge rod 10 feet (SS type) as per IS Standard as directed by the field Engineer. |
| 62 | Supply of First Aid Kit |
| 63 | Supply and Erection of Rubber mat of size 2000 × 1000 × 10 mm as directed by the field Engineer. |
| 64 | 22kV PT Insulators |
| 65 | 11KV PT Insulator |
| 66 | 11KV, 120KN Disc insulators (Antifog) |
| 67 | Supply and provision of M8, M10, M12 and M16 (full /Half thread) G.I.bolt and nuts of various sizes including plate/ spring washers as required and as directed by the field Engineer. |
| 68 | Labour for the Erection of 33/22/11kV Breakers complete set using Crane with proper levelling, proving holes cutting, jointing, wherever required, Erection of 3Nos CTs without crane, Providing conductor jumpers from Isolator/Bus to Breaker, Breaker to CT's, CTs to Isolators, Supply & Erection of Earthing steels Four Risers Breaker Structure from Earthmat/ electrode using 50x08 MSF, Providing Flexible tinned copper Earthing loops to the Breaker earthing points, Supply & painting of first primer coat of redoxide and two coats of Bus green Enamel paint on to the Earth risers including cost of reputed make paints, consumable, freight, etc, and as directed by the field Engineer. |
| 69 | 33 KV Breaker using crane arranged by the contractor |
| 70 | 11 KV Breaker using crane arranged by the contractor |
| 71 | Labour for the erection of Potential Transformers, Supply and Erection of Earthing steels using 50x8 MSF & Flexible tinned copper loops to equipment & Junction box earthing, structure earthing, Erection of Junction boxes, Supply and erection of Fixing steels, Painting of Primer Redoxide, Two coats of Bus Green enamel Paint on Earthing steels with supply of reputed make paints, including freight & all consumables as directed by the field Engineer. |
| 72 | 33KV Bus PT (3 Unit) |
| 73 | 11 KV Bus PT(Single unit) |
| 74 | Labour for the Erection of Control Panels includings consumables as directed by the field Engineer. |
| 75 | Simplex type/AC/DC/C&R Panel of Non-Grid type, Battery Chargers, Single feeder Control/ Relay Panels of Grid type (P&C) |
| 76 | Labour Charge for Erection of battery charger, including consumables as directed by the field Engineer |
| 77 | Labour for Erection of Battery set including two coats of painting of Acid proof paint on wooden stand (including any modification if required) and neatly stacking the Battery cells and fixing of connecting plates including any modifications/ alterations required as directed by field Engineer |
| 78 | Labour, Consumables for the Initial filling and First Charging of the Battery to the required AH input and thereafter atleast 3 cycles of Charge / Discharge of the Battery set till the battery is charged to its full Capacity as directed by the field Engineer. |
| 79 | Labour for erection of cable in duct/ trench/ clamping on structures - neat laying in the ducts with identification Aluminium tags in all duct corners for easy identification of cables including fabrication of clamps and fixing at uniform intervals as directed by the field Engineer |
| 80 | Upto 8Core |
| 81 | Above 8 core |
| 82 | Supply and glanding of ISI mark cable gland of suitable size of reputed make including removing of insulation of cables and providing suitable holes as required and as directed by the field Engineer. |
| 83 | 19 mm |
| 84 | 25 mm |
| 85 | 28 mm |
| 86 | Supply and termination of cable core end dressed neatly including the cost of cable socket (lug) ferrules, sleeves, tags, ties, stropes, etc., as directed by the field Engineer. (No.of core ends in unit of 1000). |
| 87 | Labour for the Erection of Strung bus and all related hardwares, fittings, clamps including Meggering, hoisting of insulators and consumables and as directed by the field Engineer. |
| 88 | upto 33kV Single Conductor Strung Bus/phase |
| 89 | Supply and fabrication and erection of Galvanized Iron eye bolts/ grout bolt with 20/22 mm rod confirming to IS with proper threading and 2 nos MS Nuts as directed by the field Engineer |
| 90 | Eye bolt |
| 91 | groutbolt |
| 92 | Labour for the Erection of Jumper/ Droppers using Moose/ Zebra/ panther Conductors including Modification of End clamps, providing holes etc wherever necessary as directed by the field Engineer. |
| 93 | Labour for erection of LAS station/ Distribution type single unit including monitors & accessories. |
| 94 | Supply & Fixing of Aluminium Power Connectors/ Clamps/ Fittings with SS Bolts and Nuts, including, freight etc., confirming to IS as per the drawing and specification. |
| 95 | Tension fitting Clamp 4 Bolted for Zebra |
| 96 | T Clamp for 2\\" Bus to Single Zebra |
| 97 | T Clamp for Zebra to Zebra |
| 98 | Switchend clamp for Single Zebra |
| 99 | Switchend clamp for 2\\" Busbar |
| 100 | Reducer clamp for 2\\" Bus to Zebra |
| 101 | PG Clamp for Zebra |
| 102 | Free end clamp for 2\\"Busbar |
| 103 | Corana Bell for 50mm Bus Bar |
| 104 | Seating Block for 2\\" Bus bar(for giving Elect Conn) |
| 105 | Fabrication, supply and fixing of C.T/P.T junction box of size 400x300x150 mm of 16 SWG(1.6mm) M.S.sheet with primer coat paint, Supply, Fabrication and erection of Box fixing Flats using 50x8 MSF, Supply and Fixing of 25x3mm² Braided Flexible tinned copper loops to box earth., Two coat of Enamel Paint, provision for fixing terminal blocks/ MCBs including consumables, freight, etc., as directed by the field Engineer on site requirements. (The box shall be vermin proof shall have sturdy hinges, & locking arrangements) |
| 106 | Supply and fixing Fuse (HRC Backlite)unit of reputed make with ISI as directed by the field Engineer including drilling &fixing. |
| 107 | 16 Amps |
| 108 | 63 Amps |
| 109 | Supply and fixing of HRC fuse of reputed make as directed by the field Engineer. |
| 110 | 16 Amps |
| 111 | 63 Amps |
| 112 | Supply and fixing of MCB of Havells/Schneider/MDS/ reputed make with ISI mark whereever required as directed by the field Engineer. |
| 113 | 32 Amps - 3 Phase, 4 Pole |
| 114 | 16 Amps - 1 Phase, 1 Pole |
| 115 | Fabrication, supply and fixing A.C.distribution box of size 750x750x250 mm out of 14SWG (2mm) M.S.Sheet including primer paint coat, Supply, Fabrication and Erection of Fixing Flat using 65x10MSF, supply & fixing of 3 nos 200A and 6 nos 100A Porcelain fuse units, Supply and Painting of Two coat of Enamel Paint including cost of materials, consumables, fright, etc., as directed by the field Engineer. The box shall be vermin proof shall have sturdy hinges, provision for mounting MCB and MCCB, detachable gland plate and locking arrangements. |
| 116 | Supply and fixing of AC single/ 3 phase 4 pole 415V ISI mark changeover switch of reputed make iron glad metal switch as required and directed by the field Engineer.63A |
| 117 | Labour for erection of Isolators with proper allingments including accessories, Meggering and cost of consumables and lubricants and as directed by the field Engineer. |
| 118 | 33 KV |
| 119 | 11 KV |
| 120 | Supply and erection of \\"B\\" class G.I.pipe for extension of tandem/ down pipe for A.B.Switches and for any other work required as directed by the field Engineer. |
| 121 | Labour for the Erection of the fabricated steel structures at the SS site with Supply of GI Bolts, Nuts & Washers (Spring/Flat as required) confirming to IS including Labour, machinery and Consumables as required & as directed by the field Engineer. |
| 122 | 33 KV Four Pole structure (Incomer) |
| 123 | 33 KV Strung Bus structure |
| 124 | 33 KV Power Transformer Gantry structure |
| 125 | 33 KV AB switch structure (1.8 m centre) |
| 126 | 33 KV LAS Structure under Bus Bar (1.8 m centre) |
| 127 | 11 KV Feeder Bay structures with 4Bays + 1 LV |
| 128 | 11 KV Station Transformer structure |
| 129 | Non-specified structures, Extension, Alterations, and Deductions as per station requirement. |
| 130 | Heavy section using RSJ 250 x 125 mm / 200 x 100 mm |
| 131 | Light section (other than heavy section) |
| 132 | Other station structure |
| 133 | 33 KV Breaker Platform |
| 134 | 11 KV Breaker Platform |
| 135 | Yard Fire Stand frame with top canopy cover |
| 136 | Battery Room Fire Stand |
| 137 | AC Junction Box fixing frame |
| 138 | Supply and Erection of 5m Grouting type lamp post of B class MS pipe (3 inch dia for 3mtrs & 2.5inch dia for 2mtrs) including single/double fitting (Straight or 'V' type) fixing arrangements, 1 inch dia B class pipe arms, yard light box fixing flat and one coat of redoxide and one coat of aluminium paint. |
| 139 | Supply and Erection of reputed make street light fitting with 1x(70-75)W or 2x(35-40)W, 240V CGL/ PHILIPS make LED Light. |
| 140 | Supply of Erection of yard light fuse unit mounting box of size 200x200x150mm (BxHxD) out of 18 SWG (1.22mm) M.S Sheet including primer paint as per Drawing including the Supply, Fabrication and Erection of Box fixing Flat using 50x8MSF, Two coat of enamel paints, provided with 16/20A rewirable Porcelain Fuse carrier unit, 16 A Bakelite connenectors including its cost materials, consumables, freight, etc and as directed by the fiels Engineer on site requirements. (The box shall be vermin proof, shall be provided with sturdy hinges, with provision for cable entry and locking arrangements). |
| 141 | Labour for the erection of Busbar including suitable Modifications of End Clamps, providing holes wherever necessary as directed by the field Engineer. |
| 142 | 50mm(1length) |
| 143 | 50mm with bend(1length) |
| 144 | Providing Earth bore 140/150 mm dia using power rig or 100/125 mm dia using hand bore set including the labour, lead, lift etc., sedimentary strata of clay & sand stone shale pebbles boulders etc., for earth Pits with supply and providing of Bentonite powder (Sodium Bentonite) 5Kg /Mtr depth of the bore mixed with low resistivity earths as directed by the field Engineer (Earth to be supplied by the contractor) |
| 145 | Supply of Various types of Steel materials confirming to ISS 2062 –Gr A including, Freight, Handling, etc., at site for Earthing with Labour for Fabrication & erection for Earthing including Labour, Machinery and Consumables as Required and as directed by the Field Engineer. |
| 146 | Labour for excavating and refilling of earth /trench for earthmat, cable, etc., of any size/depth narrow excavation as directed by the field Engineer. |
| 147 | Supply and providing of 450-600 mm dia, 300 mm height, 36 mm thick cement collar for identification of earth electrode location as directed by the field Engineer. |
| 148 | Labour charges for two coats of enamel painting in substation structures, steels etc., including the cost of reputed make paints and other consumables as directed by the field Engineer. |
| 149 | 33/22 KV Breaker Platform |
| 150 | 11 KV Breaker Platform |
| 151 | Yard Fire Stand frame with top canopy cover |
| 152 | Battery Room Fire Stand |
| 153 | AC Junction Box fixing frame |
| 154 | Labour charges for writing details in any finished surface/board including cost of enamel paints and other consumables as directed by the field Engineer. |
| 155 | Supply & Labour charges for two coats of enamel painting in any substation structures, steels, etc and wherever required including the cost of reputed make paints and other consumables as directed by the field Engineer. |
| 156 | Supply & fixing of LC/Key board out of 75x 25mm Alu. frame embedded with 12mm pre-laminated wood particle board using screw on rear side, 2Nos plain glass sliding shutter of 5mm thick fixed with metal roller on Alu.channel with locking arrangements, glass piece handle shutters, wall clamp, key hooks as directed by the field Engineer including cost of all materials & all consumables. |
| 157 | Labour charges for drawing layout and writing details/ Vinyl Printing in LC/ Key board including cost of enamel paint (Dulex, Asian, Berger preferred) and Other consumables as directed by the field Engineer. |
| 158 | Commissioining of 33KV SS electrical equipments (Except Power Transformer) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender