Tender for B.O.Q For Construction Of Double Storied Building For Composite School At Hss Chandilora
BOQ
| Sl. No. | Item Description |
| 1 | Part-A (Internal Electrification) |
| 2 | Wiring for Light point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in existing surface/recessed Conduits laid in slabs.The job including cost of Circuit Wire (6/8 points per circuit) in 2.5 sq.mm (with 1x2.5 sq.mm) for earth Multi strand Copper wire from Switch board to D.B complete (Havells/Polycab/Anchor Make) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front,Modular blanking plate where required & suitable GI box etc ISO/IEC Certified Havells/ Legrand/Panasonic/Anchor Rooma Plus/Schneider Make & shall be approved before execution of work. |
| 3 | Wiring for Ceiling fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in existing surface/recessed Conduits(Havells/Polycab/Anchor Make) complete with 01 No. of 6 Amp Modular Switch,Two Module Stepped Type Electronic Fan Regulator, Modular Plate,Cover in front and suitable GI box etc ISO/IEC Certified Havells/ Legrand/Panasonic /Anchor Rooma Plus/Schneider Make & shall be approved before execution of work. |
| 4 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor Make) including cost of Conduits with other accessories like bends,etc complete to be laid in wall and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Paint etc with 01 No. of 16Amp,Modular switch, Modular 01 No. of 3-PIN 16Amp Socket, Modular plate, cover in front,Modular blanking plate where required and suitable GI box etc ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor Rooma Plus/Schneider Make & shall be approved before execution of work. |
| 5 | Wiring for 6Amp Plug (Computer) with (P+N+E) 3 x 2.5 sq.mm FRLS PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab /Anchor Make),including cost of Conduits other accessories like bends etc complete to be laid in wall and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Paint etc with 02 No. of 6 Amp Modular Switch, 02 No.of Modular 6 Amp.of 5-PIN Socket,Modular Plate,Cover, Modular blanking plate where required and suitable GI box etc ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor Rooma Plus/Schneider Make & shall be approved before execution of work. |
| 6 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor Make) including cost of Conduits with other accessories like bends etc complete to be laid in wall/ceiling(Slab) & shall be approved before execution of work. |
| 7 | 2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. |
| 8 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/ Sub main in One run from Main Panel to Distribution Boards. |
| 9 | 2x4 sq.mm+ 1x4 sq.mm (P+N+E) for Inverter Sub main in One run from Main Panel to Distribution Boards. |
| 10 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Inverter Circuit in One run from switch boards to Distribution Boards. |
| 11 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider Make) |
| 12 | Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ABB/Schneider Make) |
| 13 | 40Amp. |
| 14 | 63Amp. |
| 15 | Supplying and Fixing of MCB 8-Way (4+ 24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider Make) |
| 16 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEMNecessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job. |
| 17 | Supply/Installation/Testing and Commissioning of 18W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Jaguar/Bajaj Make. |
| 18 | Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 19 | Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Polycab/LUKER USA Make.(Minimum 3-Star) |
| 20 | Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified. |
| 21 | Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires. |
| 22 | Supply/Laying of 25/32/38mm Dia PVC Conduit of Anchor/Ravinder/Polypack/Finolex Make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Paint/Tiles with same Colour etc. |
| 23 | Supply/Installation/Testing and Commissioning of AC/DC Bells of standard make with its batteries |
| 24 | Supply and Fixing of Modular 32Amp industrial Socket outlet having fitted with 32 Amps DP MCB and Top with Modular Plate,Cover in front & suitable GI box etc for AC Points |
| 25 | Supply and Fixing of single pole blanking plates on existing MCB boxes, excluding cost of Boxes. |
| 26 | Supply/Installation/Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/LUKER USA Make.(Minium 3-Star) |
| 27 | Desgin/Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall / floor mounted) compartmentalized , 415 volts TPN MCCB Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices(1) Normal Incoming160 Amp TPN MCCB with breaking capacity of 50 KA thermo magnetic adjustable based with extended Thimbles of Legrand/ Siemens/ ABB /Schinder /L&T make = 1 no 200 Amp TPN Bus bar Al Strips = 1 SetVolt meter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1set,Selector Switch = 1 No.Outgoing .(1) 125 Amps Double Pole MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 4 No for G/F Heating /AC Sub main(2) 63 Amps Double Pole MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 4 No for normal lighting sub main(3) 32 Amps Double Pole MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 4 No for G/F Sub main invertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) is to approved by Engineer Incharge before manufacturing |
| 28 | Supply/Installation/Testing & Commissioning of 1-phase 15 KVA,50 Hz Oil cooled unbalanced type Voltage Stabilizer SERVO control of Approved brand COPPER wound of Chinar/AE/Cosco Make ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications :Input voltage(Ph-Ph) ranging from 90 Volts to 240 Volts and a balanced output Voltage of 230 Volts, ±2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL, High cut/Low Cut /Time delay/Over Cut through Micro Controller and Spike Protection having 01 No. 63 Amp 3 Pole TP 36kA from input side & 63 AmpTPN from output side Complete job. |
| 29 | Supply/Fixing of Modular Neon Indicator,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells/ Legrand/Panasonic/Anchor Rooma Plus/Schneider Make & shall be approved before execution of work. |
| 30 | Supply/Installation/Testing and Commissioning of 3-Phase, Four Pole 100 Amp,415V Ac,50Hz offload Manual Changeover Switch side handle in enclosure Havells/L &T/ABB Make including S/F/Crimping of Suitable Size of thimbles for connections as per site requirement for bypassing 50 KVA AVR. as approved. |
| 31 | Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make. |
| 32 | Supply/Laying/Connecting and Commissioning of 50 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender