Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58113927

Tender For Providing Of Mt Garage Shed At Wuzur Under Age B/R (P) Of Ge 861 Ews

Issued by Statutory Bodies & Commissions/Committees · Anantnag, Jammu and Kashmir
Tender Value
17.28 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
20 days left
EMD
35000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Providing Of Mt Garage Shed At Wuzur Under Age B/R (P) Of Ge 861 Ews

BOQ

Name of Work:- PROVN OF MT GARAGE SHED AT WUZUR UNDER AGE B/R (P) OF GE 861 EWS
Sl. No. Item Description
1Material and Labour for Excavating in post holes (or similar holes)each not exceeding 0.5 cum.getting out in hard/ dense soil,returning, filling in and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed by Engineer-in-Charge.
2Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in Hard /dense soil complete all as specified and as directed by Engineer-in- charge.
3Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in Hard/Dense soil complete all as specified and as directed by Engineer-in-Charge.
4Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as spefied and as directed by Engineer-in-Charge.
5Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in any type of soil complete all as spefied and as directed by Engineer-in-Charge.
6Material & Labour for PCC 1:4:8 , Type - D2, using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
7Material & Labour for PCC 1:3:6 , Type -C1, using 20mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
8Material & Labour for Brickwork with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
9Material & Labour for Hardcore of broken stone or boulders ,gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge..
10Material & Labour for 100mm thick plain cement concrete 1:3:6, Type C2 (using 40mm graded stone aggregates as in sub base of floor complete all as specified and as directed by Engineer-in-Charge.
11Material & Labour for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by Engineer-in-Charge.
12Material & Labour for Machine Pressed Precast Interlocking paver block with grey cement and no pigment, factory made, any shape and size, conforming to IS 15658-2006 of 100 mm thickness, made out of M-50 grade concrete laid over sand cushioining complete all as specified and as directed by Engineer-in-charge. Note:Sand cushioning shall be measured and paid seperately under approriate item of Schedule'A' BoQ.
13Supply & Fixing Mild steel work as in tubular trusses and tubular post including special shaped washer etc.complete using ERW or induction butt welded tubes conforming IS:1161-1979 Grade St-240 complete all as specified and as directed by Engineer-in-Charge.
14Supply & Fixing Mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410 -W (Gde- E- 250) quality-A includingdistance pieces, cleats etc. complete all as speicied and as directed by Engineer in charge.
15Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge.
16Material & Labour for preparation of newely steel surfaces of any description, over 10 cm in width or girth or otherwise described , with and including applying two coat of syntheic enamal paint over with and including one coat of red oxide zinc chrome primer complete all as spefied and as directed by Engineer-in-Charge.
17Material and labour for Rendering 10mm thick in Cement Mortar 1:4 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
18Material and labour for Rendering 15mm thick in Cement Mortar 1:6 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
19Material and labour for 75 mm thick PCC (1:3:6) Type C-2 using 40mm graded stone aggregate as Sub base in flooring finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge
20Material and labour for preparation of new surface of walls, with and including two coats of cement base paint ,over with and including one coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
21Material and labour for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge.
22Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), in new PVC conduit complete with and including 1.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , drawn through with and including new PVC rigid conduit 20mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all new fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick ) and flush fixed with cement mortar 1:4 , 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover for switches 5Amp/6Amp , socket outlet 5Amp/6Amp and fan regulator, for light / fan point controlled by one way switch 5Amp / 6Amp, top cover fixed with brass screws & cup washers, with and including one single core 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. with and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge .Notes for serial item nos. 22.00 to 24.00 : (i) Switches one way 5 /6 Amp , Switch socket combination 2 in 1, 3 pin, 5 Amp & Switch socket combination 2 in 1, 3 pin, 15 Amp shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.(ii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips as directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account.
23All as per serial item No 22.00 of BoQ here-in-before but for Switch socket combination 2 in 1, 3 pin, 5 Amp on independent board complete all as specified and directed by Engineer-in-charge.
24All as per srl item No 22.00 of BoQ here-in-before but 2.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked with and including one single core 2.50 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) as continues earth wire connected to earth dolly etc for Switch socket combination 2 in 1, 3 pin, 15 Amp complete all as specified and directed by Engineer-in-Charge.
25Supply and fixing Switch piano flush type 5/6 Amp single pole one way ISI marked complete all as specified and directed by Engineer-in-Charge.
26Supply & Fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal 240 volt (ISI Marked ) complete all as specified and directed by Engineer-in-Charge.
27Supply & Fixing Switch socket combination 2 in 1, 3 pin, 15 Amp flush type universal 240 volt (ISI Marked ) complete all as specified and directed by Engineer-in-Charge.
28Supply and Fixing in Decorative ultra slim linear LED 20 Watt 4 Feet Long lighting fixture with extruded aluminium heat sink,environment friendly, Energy efficient , ready to use pack with and including LED Tube complete , with inbuilt electronic driver, PCB, Connector block complete all as per manufactureres instructions with and including connecting up with theree copper flexible cable from ceiling rose to fitting including connectiong up and fixed on with and including two nos.square box of required size complete all as specified and directed by Engineer-in-charge. Notes:(a) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
29Supply and fixing ceiling rose PVC/ Polycarbonate insulated body type, 3 terminals, 240 volts, 5 Amps complete all as specified and directed by Engineer-in-Charge.
30Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 8 way 230 V AC with 200 Amp rated copper bus bar, Double Door, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account.
31Supply and fixing MCB SP 6 to 32 Amps, 230 volts , AC supply , rupturing capacity not less than 10KA,' C' Curve ,ISI Marked, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge.
32Supply and fixing MCB DP (Douple Pole) 22 Amps to 32 Amp , rupturing capacity not less than 10 KA 'C' curve 230 V AC, 50 Hz ,ISI Marked, with and including necessary attachment , thimbles etc. complete all as specified and directed by Engineer-in-charge.
33Supply and Fixing for LED floodlight 70W 230V AC Out door type with high pressure die cast aluminium hosing and heat resistant complete with light driver holder and diffuser, ploycarbonate body and ribbed opal diffuser complete with lamp, with impact and corrosion resistant including thermal management and all other accessories fitting arrangement as per manufacturer's instructions with and including electric connection connecting with using flexible copper wire twin core upto ceiling rose/ connector complete all as specified and as directed by Engineer-in- charge. Notes:(a) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
34Material and Labour Sub main wiring with two single core of size 4.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked , with and including PVC casing and capping medium grade of suitable size run on wall/surface with all fittings (ISI Marked) , drawn in , with and including one single core of size 4.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked as in contineous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in- charge. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. Notes:-(a) Cost of PVC casing and capping medium grade of suitable size , fittings and earth wire included in sub main wiring. (b) Three single core 4.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked with and Cost of PVC casing and capping medium grade of suitable size and fittings shall be measured as one length.
35Material and Labour Sub main wiring with two single core of size 6.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked , with and including PVC casing and capping medium grade of suitable size run on wall/surface with all fittings (ISI Marked) , drawn in , with and including one single core of size 6.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked as in contineous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in- charge. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. Notes:-(a) Cost of PVC casing and capping medium grade of suitable size , fittings and earth wire included in sub main wiring. (b) Three single core 6.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked with and Cost of PVC casing and capping medium grade of suitable size and fittings shall be measured as one length.
36Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 10 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
37Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 4.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
38Supply and Laying GI tubing 50mm bore Light grade with all fittings such as clamps laid in trenchs or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip for mechanical protection laid under plinths/floors/roadss/culverts or fixed on walls or concealed or along the steel poles means of M.S.F Clamps with necessary nolts & nut washers complete all as specified and as directed by Engineer - in charge.
39Material and Labour Steel tubular poles type 410 SP-31 (9.00mtr long) complete with cast iron base plate, finial, taper plug, bolts nuts & screws complete all as specified including internal surface of steel tubular pole through out and external surface up to planting depth shall be painted with bituminous paint and remaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer complete and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles all as specified. Note:- Necessary earthwork and cement concrete work shall be measured and paid seperately in respective items of respective schedules. (Note:- Excavation, earthwork and PCC shall be measured and paid separately under respective item of Sch.)
40Supply & Fixing LED Security street light fitting 35 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
41Supply and Fixing street light junction /pole box of size 250mm x 200mm x 150 mm made of MS sheet 1.6mm thick front openable with fixing screw painted with two coat of synthetic enamelled paint over one coat of red oxide zinc chrome primer with and including two nos of aluminium bus bar 20mm x 3 mm mounted on epoxy based post insulator and drilled holes for cable connection with and including one no. MCB SP 6 Amp curve 'C' , 10 KA complete all as specified and directed by Engineer-in-Charge.
42Supply & Fixing security light brackets made with light grade galvanised iron pipe 1.20mtrs long with 100-120 degree bend including arrangement of fixing at pole/wall/angle with help of flat iron clamps and suitable nuts and bolts including all material required or fitting all as specified and directed by Engineer-in-Charge.
43Supply and Fixing 1.5 Sqmm three core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable(flexible) 1100 volt grade ISI Marked complete all as specified and directed by Engineer-in-Charge.
44Supply and Fixing Change Over Switch 4 pole 415 volts on load of rating 63Amp with and including sheet enclosure complete complete all as specified and directed by Engineer-in-Charge.
45Supply and fixing MCCB 63 Amp , AC 415 Volt, 4 Pole , rupturing capacity not less than 36 KA . complete all as specified and directed by Engineer-in-charge.
46Supply,installing,testing and commissioning of CPRI approved LT panel outdoor type of size minimum 60 cm x 45cm x 60 cm (LxWxB) or larger suitable size weather/vermin proof,made out of 3.15mm thick CRCA sheet duly powder coated,mounted on 65mm x 65mm x 5mm (ISA 65 x 65mm ) biron angles frame of height 45cm from pCC bedding,factory assembled compartmentalized construction,free standing type including 3phase and neutral 100amps current carrying capacity Aluminium bus bar with epoxy insulated coating with colour code and insulated support,cable galleries inter connecting bus bar connection/linkage complete and conforming to IS 8623 and IP 54 class of protecxtion as per IS 2147 complete,including making connection of cables of incoming and outgoing with THimble/lusg,including the accessories as below comnplete and mounting the panel on ground floor with PCC(1:3:6) bedding upto a height of 45 cm above ground level complete all as specified and directed by Engineer-In-Charge.a) Aluminium Bus bar 100 Amps for 3 phase & Neutral - 1Setb) MCCB 4 Pole , 63 Amps , 35K , 415 V - 1No. (Incoming)c) MCB SPN 32 Amps , 230 V- 4Nos. (Outgoing)d)Digital Voltmeter with selctor switch 0 to 500 Volts- 1No.e)Digital Ammeter with selctor switch with suitable size CT's - 1No.f)LED type indicator Lamps (R
47Material and Labour for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
48Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI strip 25mm x 4mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washersand including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI mediumt grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) Earth continuity of GI strip 25mm x 4mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
49Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose)
50Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58113927
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 17.28 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Mt Garage Shed At Wuzur Under Age B/R (P) Of Ge 861 Ews
Basic Detail
Tender No GE 861 EWS-59(T)/2026-27
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 17 Oct 2026
Submission Date 09 Nov 2026
Open Date 11 Nov 2026
Finance
Tender Value 17.28 Lakhs
Tender Fee 500
EMD 35000
Exemption Not Available
Document List
b277ca3b-4862-43cb-892e-aa48b12a8d1f.html
BOQ_891148.xls
Tender59T.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.