Tender For Work For Construction Of 132 Kv Line Bay At 132 Kv Substation Kazrahat Under Electricity Transmission Division-Iii, Sahupuri
Tender Overview
Project Description
Tender for Work For Construction Of 132 Kv Line Bay At 132 Kv Substation Kazrahat Under Electricity Transmission Division-Iii, Sahupuri
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Nov-2026 | Opening Dated Extended | Date | 25-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Part A: Erection |
| 2 | Erection of Auxiliary & Main structure consisting of columns, beams, peak mast etc. required for installation of 132 KV equipments. The job consists of shifting of all materials of structure parts with nut & bolts washer etc. from store to work site distance approx 200 Mtrs, erection of structure as per relevant drawing and procedures using flat & spring washers with each bolts and matching of holes also be done by contractor. All materials shall be supplied by UPPTCL free of cost. The labour and required T&P shall be arranged by contractor at his own cost. |
| 3 | Erection of following equipments as per instruction manual of various equipments and technical specification including shifting of equipments from store to site including all other associated work to complete the job satisfactorily: |
| 4 | 132 KV CB |
| 5 | 132 KV CT |
| 6 | 132 KV PT |
| 7 | 132 KV LI |
| 8 | 132 KV BI |
| 9 | 132 KV LA |
| 10 | 132 KV Post insulator |
| 11 | 132 KV CT Junction Box |
| 12 | 132 KV PT Junction Box |
| 13 | 132 KV C&R Feeder Panel |
| 14 | Laying of following size control cable in the cable trench from control panel, relay panel to various equipments, Junction Box as per cable schedule and drawing, its strapping/binding at every 1 meter distance with aluminium strip 25x1 mm size including carriage of cable drum from store to laying site and shifting back to store and all other associated work. |
| 15 | 2C x 2.5 mm² |
| 16 | 4C x 2.5 mm² |
| 17 | 6C x 2.5 mm² |
| 18 | Terminating of following size of control cable as laid above as per cable schedule including making necessary holes in glands plate or box wherever required. Supply and fixing of cable gland of appropriate size. Supply and fixing of ferrules for each size lug and all other associated work to complete the job satisfactory as per technical specification. |
| 19 | 2C x 2.5 mm² |
| 20 | 4C x 2.5 mm² |
| 21 | 6C x 2.5 mm² |
| 22 | Making and jointing of Jumpers from main Bus to different types equipments with panther conductor store to jumper site, cutting of proper size Jumper, fixing of Jumpers in proper sag, tightening of PG Clamps, Connectors and other all associated work. |
| 23 | Cutting, Strengthening, bending, laying of 75x10 mm & 50x6 mm M.S. Flat for earthing of main and auxiliary structure, equipments etc. Including welding with main earth mat below 500-700 mm below ground level with object to earth excavation of trenches its back filling painting with synthetic enamel green color above ground and all associated work to complete the job satisfactory. The MS Flat shall be provided by the Contractor. |
| 24 | Laying of 36/40mm MS round bar,800mm below ground level in soil including excavation of trench, cutting, welding/painting, its back filling and all other associated work for 132/33 kV Line-II Bay at 132kv s/s Kazrahat. MS round bar will be provided by department. |
| 25 | Fabrication of 4mtr long electrode of 36/40mm dia MS round bar having 150mm long conical shape and fixing vertically below the earthmat level and its wielding with main earth mat and its painting. |
| 26 | Fee for electrical safety to be paid by contractor for obtaining “No Objection Certificate” from office of Electrical safety U.P. Govt. Prayagraj/Lucknow before charging of new 01 No.132KV Bay,132KV LA at 132KV S/S Chunar work includes submission of safety challan fees, arrangement of liasioning and visit of Electrical safety officer, preparation of documentation file & Submission and related works to obtain NOC for proper completion all associated work for complete the job as per instruction of Engineer/In-charge. |
| 27 | Integration of 01Nos 132kV Feeder in existing RTU at 132kV Substation Kazrahat(With material i.e MFT, CMR, DI Cable, Connectors, CT & PT Terminal Blocks with required interfacing cable |
| 28 | Part B: Supply |
| 29 | 132 KV Isolator clamp suitable for ACSR twin panther conductor with N&B |
| 30 | CT Clamp twin panther 18 mm rod size with N&B |
| 31 | Terminal Connector for 145kV PT |
| 32 | PG Clamp Suitable for Panther to Panther with N&B |
| 33 | PG Clamp Suitable for Moose to Panther with N&B |
| 34 | Nut Bolt with washers 16x40mm |
| 35 | Nut Bolt with washers 16x45mm |
| 36 | Nut Bolt with washers 16x50mm |
| 37 | Nut Bolt with washers 16x90mm |
| 38 | Portable earthing/Discharge Rod (in Canvas Bag) of \\"F\\" Class Fiber Insulation suitable for working on Transmission Network Having System Voltage up to 145 KV (length of 10m) |
| 39 | 40MM MS Rod for Main Earth Mat |
| 40 | 40MM MS Electrode 3 M length |
| 41 | Single Tension Fitting for ACSR Panther |
| 42 | Single Tension Fitting for ACSR Moose |
| 43 | Single Suspension Fitting for ACSR Panther |
| 44 | Single Suspension Fitting for ACSR Moose |
| 45 | 132kV CT Junction Box |
| 46 | 132kV PT Junction Box |
| 47 | Fire Fighting CO2 Type of 22.5 KG |
| 48 | Supply of flexible copper bond (rope type) of size 450mm long, 16mm dia & both side copper lugs heaving hole of 16mm dia and complete with nut-bolt & washer. |
| 49 | Sand Buckets |
| 50 | Stand for 10Nos Sand Buckets |
| 51 | Tripping Coil assembly for 145kV CB(02Nos each Suitable for Siemens, ABB&CGL) |
| 52 | Closing Coil assembly for 145kV CB(02Nos each Suitable for Siemens, ABB & CGL) |
| 53 | Tripping Coil for 36kV VCB(02Nos each Suitable for Siemens, ABB, CGL, Stelmac & Shreem) |
| 54 | Closing Coil for 36kV VCB(02Nos each Suitable for Siemens, ABB, CGL, Stelmac &Shreem) |
| 55 | ABB Density Monitor 145kV Circuit Breaker |
| 56 | GI Perforated cable tray (225/250mm) |
| 57 | GI Perforated cable tray (75mm) |
| 58 | 150W LED Flood Light |
| 59 | a) Any additional requirement of works, minor consumables,T&P, manpower, hydra, crane, welding machine, etc not mentioned shall be met by contractor at his own cost. b) Painting of earthing flat and earthing MOM Box with two coats of enamel paint of green colour with all cost of men and material by contractor at his own cost. c) Parallel teams of skilled and Unskilled labour shall be deployed on each equipment in a bay so that the shutdown time may be optimized and work shall be completed in minimum possible time. d) The contractor shall ensure safety of the manpower involved in the job by providing proper safety equipments such as safety shoes, safety jackets, safety belt, helmets etc. and ensure all safety compliance during work. e) At the place where digging is required will be digged and then levelled by contractor after proper completion of work. f) Working of all protection and operation of equipments/ bays will treated as completed work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender