Tender For Completion Of Incomplete Work Of Ca No : Ge/Mism/52 Of 2024-25 : special Repairs To Existing Electric Supply System At Old At Coy And special Repair/Replacement Of Pump Panel And Misc Works And Provn Of Rev Wk At Fd Wksp Coy Under Ge Missa
Tender Overview
Project Description
Tender for Completion Of Incomplete Work Of Ca No : Ge/Mism/52 Of 2024-25 : special Repairs To Existing Electric Supply System At Old At Coy And special Repair/Replacement Of Pump Panel And Misc Works And Provn Of Rev Wk At Fd Wksp Coy Under Ge Missamari
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 31-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-Nov-2026 |
| 2 | 07-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-Nov-2026 |
| 3 | 16-Nov-2026 | DATE CORRIGENDUM | Date | 21-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M & L earthing complete with Galvanised earth plate 610 x 610x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to GI earth strip 32X6 mm drawn through and including Galvanised Iron protection Pipe 40 mm bore (dia) Light grade up to height of the transformer foundation where transformer is situated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC 1:2:4 (20mm graded aggregrate ) cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 meter and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed. |
| 2 | Design, fabricate ,Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.15 mm thick CRCA steel sheet of suitable size and and angle iron 50x50x6mm, grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprise of following items and all specified in SSR part -I clause No 19.21 and connecting up all the LT UG cables including taking down old unserviceable panel boxBusbar: 1000 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance.Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : -(a) INCOMING(i) MCCB 160 Amps, 4 pole, 415 V, 35 kA - 1 No(ii) Digital ammeter with 3 Nos CTs & selector switch - 1set (iii) Digital Voltmeter with selector switch - 1 set (iv) R ,Y , B indicator Lamps 1 Set(v) onload change over 160 Amps - 1 No(b) OUTGOING(i) MCCB 100.Amps, 4 pole, 415 V, 25 kA -03 Nos (ii) MCCB 63 Amps 4 Pole , 415 V , 25 kA - 01 Nos |
| 3 | Surface dressing in soft loose soil n exc 15 cm deep and getting out, complete all as directed. |
| 4 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed. |
| 5 | Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 6 | Removing excavated material (soil) n exc 50 m & depositing where directed at a level n exc 1.5 m, complete all as directed. |
| 7 | M&L cement concrete with PCC type D2 1:4:8 using 40mm graded aggregate as in foundation, mass concrete complete all as specified and directed. |
| 8 | M&L for Nominal mix (1:1:5:3) using 20 mm graded aggrgate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass co, complete all as specified and directed. |
| 9 | M&L for Nominal mix (1:1:5:3) using 20 mm graded aggregate for columns, pillars,posts and struts, complete all as specified and directed. |
| 10 | M&L for Nominal mix (1:1:5:3) using 20 mm graded aggregate for beams, cantilevers, roof beam , lintels over 1.5 m span, etc, complete all as specified and directed. |
| 11 | M & L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, banding spirally for hooping columns, hooking end and binding with and including mild steel wire not less than 0.90 mm dia (annealed) complete all as specified and directed . |
| 12 | S&F mild steel TMT bar 5 mm dia and over upto and including 10mm dia in strrups as in including cutting, bending and binding with and including mild steel not less than 0.9 mm dia (annealed) complete all as specified and directed . |
| 13 | M&L Form work for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rought finished surfaces of concerete complete all as specified and directed. |
| 14 | M&L Form work for sides of pillars, posts, columns & similar works, square rectangular or polygonal flat, rought finished surfaces of concerete complete all as specified and directed. |
| 15 | M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc flat, rought finished surfaces of concerete complete all as specified and directed. |
| 16 | M&L for brick work with burnt old size bricks built in cement mortar 1:6 straight or curved on plan exceeding 6mtr mean radius and all as directed. |
| 17 | M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate) mixed with WPC as per manufactures instruction, complete all as specified and directed.Note:- WPC shall be measured & paid separately |
| 18 | M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth (without using extra cement), complete all as specified and directed.. |
| 19 | M&L for rendering 20mm thick with cement mortar 1:4 on fair faces of brick work in two layers (10mm and 10mm) sperately mixed with water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and fair complete all as specified and directed. Note:- WPC shall be measured & paid separately |
| 20 | Supply only integral Water proofing compund, complete all as specified and directed. |
| 21 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. |
| 22 | M&L Sand filling under floors or in foundations including watering and conosoldiation complete all as specified and directed. |
| 23 | M&L Hardcore of gauge n exc. 63 mm, Broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface,complete all as specified and directed. |
| 24 | M&L for 100mm thick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed.. |
| 25 | M&L Pre polished Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over cement screed 20 mm thick in cement mortar 1:6 complete all as specified and as directed. |
| 26 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, including dismantling floor tiling with cement mortar bedding and removing rubbish/debris off the premises complete all as specified and directed. |
| 27 | S&F Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm, Hangers 1.80 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Aluminium framework with screws and necessary preperation of surfaces and applying two of oil bound acrylic distemoer as approved complete all as specified complete and as directed. |
| 28 | Supply for anodised aluminium two track sliding window and ventilator frame side/top/shutters (weight of section not less that 0.55 Kg/RM) aluminium section without sash bar aluminium section including all necessary joining cleats,hold fast, rubber gasket anodised snap beading, anodised aluminium fittings, suitable aluminum handle and locking arrangement etc, two track for glass, including powder coated of any colour (thick of power coating not less than 50 micron) & providing AC hole complete all as specified and directed.. Note:- (i) Wire cloth /glass shall be measured and paid separately at SUPPLY only rates under appropiate items. (ii) Labour charges for fixing of wire cloth/glass panes is demeed to be included in unit the unit rate quoted. |
| 29 | S&F Prepainted galvalume aluminium zink coating (AZ-150) GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 30 | S&F Pre-painted galvalume aluminum zinc coating (AZ-150) GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.. |
| 31 | S&F Rolled mild steel Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe.410W. Gde-E- 250) quality A) including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 32 | S&F 30mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed |
| 33 | S&F 2nd class hard wood plain solid, straight chowkats and frames , wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. |
| 34 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed. |
| 35 | S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 36 | S&F 100mm MS butt hinges medium weight, complete all as specified and directed. |
| 37 | S&F 150mm aluminium handle cast type anodised, complete all as specified and directed. |
| 38 | M&L Preparation of new or previously untreated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling applying two coat of synthetic enamel paint over one coat of pink primer,complete all as specified and directed. |
| 39 | M&L preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over new surface over 1 mm thick wall care putty,complete all as specified and directed. |
| 40 | M&L preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 41 | M&L preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 42 | M&L for concealed point wiring with two single core 1.5 Sq.mm size FRLSH multistranded copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green FRLSH colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including 20mm(minimim) medium grade rigid PVC CONDUIT and conduit accessories i.e. joint boxes, terminal boxes for mounting or housing switches, socket outlets, fan regulators, etc. confirming to IS specifications, including Mild Steel Pressed Terminal Box 1.22mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, etc. with including cutting chases for conduits & sinkings for MS Sunken boxes & making good to walls, floors etc. complete all as specified & as directed for the following :- |
| 43 | All as per item No 42 herein before but light point controlled by one, one way switch 5 Amps |
| 44 | All as per item No 42 herein before but One 3 point 5 Amps socket outlets point controlled by one switch on the same board |
| 45 | All as per item No 42 herein before but One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board |
| 46 | All as per item No 42 above but with two run of 2.5 sqmm multi stranded Single core copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with one run of FRLSH PVC 2.5 Sqmm multi standard insulated sheathed copper wire as earth continuity conductor along with wiring and connecting to the common earth dolly on independent board. |
| 47 | S & F Switch piano (White) flush type single pole one way 5 Amp, 230 Volts complete all as specified. |
| 48 | S & F Socket outlet (White) 2 in 1, 5 pin, 5 Amps complete all as specified and directed. |
| 49 | S & F Switch socket combination(White) flush type multipurpose 5 pin 5 Amps two in one , 230 volts complete all as specified and as directed |
| 50 | S&F Switch socket combination (White) 2 in 1 5/6 pin, 15 Amp flush type universal,complete all as specified and as directed |
| 51 | S&F ceilling rose (White) three terminal surface bakelite type AC 50 Hz 230 Volt of size 65x50mm complete all as specified and as directed. |
| 52 | S & F ceiling fan regulator (White) step type, flush type heavy duty suitable to work on 230 Volt AC supply complete all as specified and as directed |
| 53 | S & F Lamp holder (White) with insulated body, with back plate suitable for batten fittings complete all as specified and as directed |
| 54 | S & F LED bulb 10 watt 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified. |
| 55 | S & F sheet metal enclosure MCB DB SPN , double door, 8 way with 200 amps rated bus bar 240 volts complete duly grouted laid and fixed in wall all as specified and directed. |
| 56 | S & F MCB DP 32 Amps 240 Volt, confirms to IS/IEC 60898 Breaking Capacity of 10 kA, B-curve, complete all as specified and directed |
| 57 | S & F MCB SP, 240 volts, 6-32A Amps 50 Hz ,confirms to IS/IEC 60898 Breaking Capacity of 10 kA, B-curve, complete all as specified and directed. |
| 58 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative ultra slim round profile LED lighting fixture with extruded polycarbonate , environmental friendly energy efficiebt ready to use pack with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 59 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 20 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete all as directed. |
| 60 | Supply and fixing ceiling fans without remote complete with blades, down rods, , fan hook and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 61 | S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 62 | M & L sand cushioning in trenches for cable protection with coarse sand laid dry in trenches with uniform thickness including consolidation complete all as directed. |
| 63 | Supply & Laying well burnt brick , locally available best quality (sub class \\"B\\" bricks ) laid in trences perpendicular to UG Cable protection complete all as specified. |
| 64 | Supply & Laying XLPE LT heavy duty UG Cable of size 16 Sqmm 2 Core laid in trences /floor/on wall/service connection PVC Insulated, sheathing and armd 1100 Volts grade with aluminium conductor including connection to the main switch/cut out MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed. |
| 65 | S & F GI Tubing light grade of size 40mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clam as per site requirement etc all as specified and directed. |
| 66 | M & L earthing complete with copper Earth Plate Electrode 600mm x 600mm x 3.15mm, thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to Copper earth strip 20x3 mm drawn through and including Galvanised Iron protection Pipe 32 mm bore (dia) Light grade up to height of the transformer foundation where transformer is situated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC 1:2:4 (20mm graded aggregrate ) cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 meter and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed. |
| 67 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. |
| 68 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. |
| 69 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. |
| 70 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. |
| 71 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. |
| 72 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sqmm 4 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. |
| 73 | Design, fabricate ,Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.15 mm thick CRCA steel sheet of suitable size and and angle iron 50x50x6mm, grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprise of following items and all specified in SSR part -I clause No 19.21 and connecting up all the LT UG cables including taking down old unserviceable panel boxBusbar: 200 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance.Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : -(a) INCOMING(i) MCCB 160 Amps, 4 pole, 415 V, 35 kA - 1 No(ii) Digital ammeter with 3 Nos CTs & selector switch - 1set (iii) Digital Voltmeter with selector switch - 1 set (iv) R ,Y , B indicator Lamps 1 Set(v) onload change over 160 Amps - 1 No(b) OUTGOING(i) Star Delta Starter of capacity 25 HP with MCCB 63.Amps, 4 pole, 415 V -04 Nos (ii) DOL Starter of capacity 5 HP with MCB TPN 40 Amps along with Ammeter , 4 Pole 415 Volts -06 Nos(iii) MCCB 63 Amps 4 Pole , 415 V , 25 kA - 01 Nos(iv) MCB SPN 40 Amps -02 Nos |
| 74 | Design, fabricate ,Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.15 mm thick CRCA steel sheet of suitable size and and angle iron 50x50x6mm, grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprise of following items and all specified in SSR part -I clause No 19.21 and connecting up all the LT UG cables including taking down old unserviceable panel boxBusbar: 160 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance.Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : -(a) INCOMING(i) MCCB 100 Amps, 4 pole, 415 V, 35 kA - 1 No (ii) Digital ammeter with 3 Nos CTs & selector switch - 1set (iii) Digital Voltmeter with selector switch - 1 set (iv) R ,Y , B indicator Lamps 1 Set(b) OUTGOING(i) Star Delta Starter of capacity 35 HP with MCCB 63.Amps, 4 pole, 415 V -01 Nos (ii) MCB SPN 40 Amps -02 Nos |
| 75 | Design, fabricate ,Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.15 mm thick CRCA steel sheet of suitable size and and angle iron 50x50x6mm, grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprise of following items and all specified in SSR part -I clause No 19.21 and connecting up all the LT UG cables including taking down old unserviceable panel boxBusbar: 125 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance.Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : -(a) INCOMING(i) MCCB 63 Amps, 4 pole, 415 V, 35 kA - 1 No (ii) Digital ammeter with 3 Nos CTs & selector switch - 1set (iii) Digital Voltmeter with selector switch - 1 set (iv) R ,Y , B indicator Lamps 1 Set(b) OUTGOING(i) Star Delta Starter of capacity 35 HP with MCCB 63.Amps, 4 pole, 415 V -01 Nos (ii) MCB SPN 40 Amps -02 Nos |
| 76 | Design, fabricate ,Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.15 mm thick CRCA steel sheet of suitable size and and angle iron 50x50x6mm, grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprise of following items and all specified in SSR part -I clause No 19.21 and connecting up all the LT UG cables including taking down old unserviceable panel boxBusbar: 200 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance.Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : -(a) INCOMING(i) MCCB 125 Amps, 4 pole, 415 V, 35 kA - 1 No (ii) Digital ammeter with 3 Nos CTs & selector switch - 1set (iii) Digital Voltmeter with selector switch - 1 set (iv) R ,Y , B indicator Lamps 1 Set(b) OUTGOING(i) Star Delta Starter of capacity 35 HP with MCCB 63.Amps, 4 pole, 415 V -02 Nos (ii) MCB SPN 40 Amps -03 Nos |
| 77 | Design, fabricate ,Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.15 mm thick CRCA steel sheet of suitable size and and angle iron 50x50x6mm, grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprise of following items and all specified in SSR part -I clause No 19.21 and connecting up all the LT UG cables including taking down old unserviceable panel boxBusbar: 630 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance.Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : -(a) INCOMING(i) MCCB 400 Amps, 4 pole, 415 V, 35 kA - 1 No (ii) Digital ammeter with 3 Nos CTs & selector switch - 1set (iii) Digital Voltmeter with selector switch - 1 set (iv) R ,Y , B indicator Lamps 1 Set(b) OUTGOING(i) Star Delta Starter of capacity 150 HP with MCCB 250.Amps, 4 pole, 415 V -05 Nos (ii) MCB SPN 40 Amps -03 Nos(iii) MCCB 63 Amps 4 Pole , 415 V , 25 kA - 01 Nos |
| 78 | Design, fabricate ,Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.15 mm thick CRCA steel sheet of suitable size and and angle iron 50x50x6mm, grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprise of following items and all specified in SSR part -I clause No 19.21 and connecting up all the LT UG cables including taking down old unserviceable panel boxBusbar: 630 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance.Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : -(a) INCOMING(i) MCCB 400 Amps, 4 pole, 415 V, 35 kA - 1 No (ii) Change Over Switch 400 Amps 4 Pole Rotary type -01 Nos (ii) Digital ammeter with 3 Nos CTs & selector switch - 1set (iii) Digital Voltmeter with selector switch - 1 set (iv) R ,Y , B indicator Lamps 1 Set(b) OUTGOING(i) Star Delta Starter of capacity 150 HP with MCCB 250.Amps, 4 pole, 415 V -05 Nos (ii) MCCB 320.Amps, 4 pole, 415 V, 25 kA -02 Nos (ii) MCCB 63 Amps 4 Pole , 415 V , 25 kA - 02 Nos Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender