Tender For Special Repair / Replacement Of Internal Wiring, Fittings, Fixtures, Mcb Dbs, Earthing And Connected Items Of Md Accn (Jco/Or) Of 151 Base Hosp Under Ge Guwahati
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Nov 2026
10 days left
EMD
58000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair / Replacement Of Internal Wiring, Fittings, Fixtures, Mcb Dbs, Earthing And Connected Items Of Md Accn (Jco/Or) Of 151 Base Hosp Under Ge Guwahati
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and as directed. |
| 2 | Taking down carefully UNSV main switch and DB's including MCBs of of any size make, type and capacity and depositing at site complete all as specified and directed |
| 3 | M&L for providing point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVC concealed conduit of adequate size but not less than 20mm in dia and 1.2mm thick with all fittings and accessories including modular surface box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan point controlled by one way modular switches, including one run 1.5 sqmm (nominal area) PVC insulated flame retardant unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed for the following :- |
| 4 | One light/ Fan/Bell point controlled by one no one way switch complete all as specified and as directed. |
| 5 | One 3/5 pin socket outlet, 5/6 Amps on same board with other switch complete all as specified and directed. |
| 6 | One 3/5 pin socket outlet, 5/6 Amps on independent board with cable of 1.5 sqmm size & other switches |
| 7 | All as per item No.2.02 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 6 pin 6/16 Amps switch socket combination on independent board. |
| 8 | All as per item No.2.02 above but wiring with 4sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 6 pin 6/16 Amps switch socket combination on independent board. |
| 9 | Supply and fixing Modular switch one way 10 Amp, single pole, 240 Volts , one module complete all as specified and as directed. |
| 10 | Supply and fixing Modular socket outlet 3 pin plug, 6 Amps, universal socket 2 and 3 pin, 240 Volts complete all as specified and as directed. |
| 11 | Supply and fixing Modular switch one way modular type, 16 Amp, 240 Volts complete all as specified and as directed. |
| 12 | Supply and fixing Modular socket, 2-in-1, 6A/16A, 2 module, 240 volts complete all as specified and as directed. |
| 13 | Supply and fixing Modular Bell push with indicator 5/6 Amp, 1 module, 240 Volts complete all as specified and as directed |
| 14 | Supply and fixing Bell, Ding dong, AC, 230 volt single pole complete all as specified and as directed. |
| 15 | Supply and fixing in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting or PVC round or square box complete all as specified and as directed. |
| 16 | Supply and fixing ceiling rose 3 point/PVC/ polycarbonate, isolated body 250/230 volts ISI marked complete all as specified and as directed. |
| 17 | Supply and fixing modular electronic fan regulator, stepped type, 220 volt, 100 watt complete all as specified and as directed. |
| 18 | S&F as in repair LED tube light fitting, 1x20/22 watt, 220-240 volt, AC, inverter type with inbuilt rechargeable lithium battery back up for emergency operation, decorative box type complete with LED tube, electronic driver, holder, diffuser and automatic changeover during power failure with minimum of 3-4 hours battery backup suitable for wall/ceiling mounting including connecting up with three core flexiblwe copper conductor of suitable size from ceiling rose complete all as specified and as directed. |
| 19 | Supply and fixing as in repair 10W LED Bulkhead light, pressure die cast housing LED bulkhead with IP65 Protection and IK09 Impact resistance suitable for surface/wall mounted,complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 20 | S&F 12 watt LED inverter Bulb, inbuilt-Rechargeable lithium-ion battery, 230 AC operation, minimum 3 hours emergency backup, B22 cap, BIS approved complete all as specified and as directed. |
| 21 | Supply and fixing in repair LED street/bldg security light fitting 35 Watt, 230V, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 22 | M&L for 32mm bore light grade GI pipe fixed as bracket, on wall any type, not less than 1.5 m long and bent to shape as required complete with sutiable clamp made out of 25x4mm Flat iron duly fixed 12mm dia nuts, bolts, washers etc fixed complete with two coats of aluminium paint over a coat of red oxide incl taking down old brackets complete all as specified and as directed |
| 23 | M&L for sub main wiring with 6 Sqmm (nominal area) with two runs (Red for phase and black for neutral) of single core FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLS) ISI marked drawn in through and including non metalic PVC concealed conduit/ casing N Caping of adequate size but not less than 25mm dia/width & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including single core 6 Sqmm earth wire, PVC insulated & unsheathed FRLS copper conductor green in colour duly connected to earth wire complete including taking down old sub main wiring complete all as specified and as directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of PVC Conduit with accessories shall be measured as one length. |
| 24 | Supply and fixing factory made MCB distribution board in sheet steel enclosure double door glazed with 200 Amps rated bus bar, SPN, 8 ways, 240 Volts suitable for housing MCBs complete all as specified and as directed. |
| 25 | S&F MCB, SPN, 240 volts, 'C' Curve, 6-40 Amps, 10 KA, confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and as directed. |
| 26 | S&F MCB, SP, 240 volts, 'C' Curve, 10 to 32 Amps, 10 KA, confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and as directed. |
| 27 | M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SI Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc including taking down old earthing complete all as specified and as directed. Note:- Rate quoted by tenderers shall be deemed to include for following provisions-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd .[v]. GI protection pipe of size 15 mm bore light grade 7.5m. |
| 28 | M&L providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and Distempering two coats with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as permanufacturer's specification on new work complete all as specified and directed |
| 29 | S&F energy efficient exhaust fan of 300 mm sweep made of PVC body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted). |
| 30 | S&F energy efficient exhaust fan of 250 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted). |
| 31 | S&F energy efficient 1200 mm sweep, BEE 5-Star rated BLDC ceiling fan suitable for operation on 230V, single phase, 50 Hz AC supply, complete with copper wound BLDC motor, electronic regulator/remote control unit, aerodynamic aluminium blades, down rod of suitable length, canopies, shackle assembly, safety pin, fan hook, connecting leads, all fixing accessories, testing and commissioning complete all as specified and as directed. |
| 32 | S&F in repair of single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB of 20 Amps 240 volts 10 KA, C series complete all as specified and directed. |
| 33 | Supply, fabrication, installation and testing of LT Panel factory made, CPRI Approved Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, in door type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out thermoplastic polycarbonate of suitable size to accommodate accessories/ fittings with front double door opening/ lockable by the key from both side and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & MCB out going with copper extension links inside for 05 Nos Energy meter single phase 2 wire 220 Volts, AC, fixing with two single core PVC copper conductor unsheathed wire multistandred 6 sqmm including one MCB SPN 32 Amp with connected accessories with glass window at front side to visualise meter reading without opening of doors accessories and mounted on DMC/ epoxy insulator including provison for termination with incoming and out going cables. Panel mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with ttwo coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate).Item continued below as srl No.30.10 |
| 34 | Item continued from item No.30.00 All extension link/interconnection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Block of 04 Qtrs)Note:- (i) Rate of earthwork and PCC work etc are deemed to be inclusive in this item.(ii) Design of LT Panel including components, layout, their design as per IEC-61439 duly certified by ASTA or other approved agency.IN COMING:a) Copper strip busbar of 200 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos, b) 4 pole MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.Item continued to 30.20 |
| 35 | Item continued from 30.10.(c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) Make :- Legrand/L&T/Schneider.(d) Digital Ammeter of range (0- 250) Amps, flush mounting type with CT's of ratio 250/5 and selector switch - 01 set.(e) Digital voltmeter of range (0-500) volts, flush mounting type with selector switch - 01 No.OUTGOING:-(a) MCB, Single pole & neutral, 40 Amps, 240 volts, 'C' curve, 10 KA all complete as specified and as directed -05 Nos (for Each Qtr and stair case)(b) Existing Single phase smart prepaid meter including necessary electrical connections- 5 Nos(c) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter -01 No. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender