Tender For Repair / Maintenance Of Fencing Zone C Area Of Age B/R-I Under Ge (West) Lucknow
Tender Value
49 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
10 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Fencing Zone C Area Of Age B/R-I Under Ge (West) Lucknow
BOQ
| Sl. No. | Item Description |
| 1 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4 ) in patches finished even and smooth without using extra cement incl taking down existing plaster complete all as specified and directed. |
| 2 | Demolition of cement concrete (reinforced) in columns/beams and paving n.exc 15cm thickness below or above ground level complete all as specified and directed. |
| 3 | M&L for reinforced cement concrete 1:1.5:3, type A-1 (using 20 mm graded stone aggregate) precast cover slabs and the like etc complete all as specified and directed |
| 4 | M&L for MS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 5 | Dismantling RCC posts and struts any section including taking out embedded portion in concrete and making good disturbed surface complete all as specified and directed. |
| 6 | Dismantling chain link fencing, wire mesh, any type and stacking at site where as directed complete all as specified and directed. |
| 7 | Excavation in post holes not exceeding 0.50cum getting out in hard/dense soil, returning, filling in layers not exceeding 25cm and making good surfaces complete all as specified and directed. |
| 8 | M & L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in foundation filling for securing posts complete all as specified and directed. |
| 9 | M&L for mild steel frame brackets of angle cut to shape, including welding , bending, embeding in concrete and screwing etc. including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 10 | M&L in repair galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed. |
| 11 | S&F framed work such as gates,grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar workconforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 12 | Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed. |
| 13 | Fixing only chain link fencing including line wires, any mesh size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 14 | M & L for 5 to 10mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed. |
| 15 | M&L for preparation of new or previously untreated surfaces of steel & iron work of any description exc 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 16 | M&L for preparation of old steel surfaces of any description exc 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 17 | M&L for concentina punch type wire 610 mm dia of each coil avg weight not less than 1.06 kg/RM after stretching including coating of antirust compound fixed on angle iron bracktes top of compound wall icluding taking down existing concentina punch type wire etc. complete all as specified and directed. |
| 18 | Labour only for taking down and refixing/ restraining resecuring including making good concentina punch type wire (any dia) fixed on angle iron bracktes top of compound wall complete all as specified and directed. |
| 19 | Welding in repairs of steel gate metal exc 2.5cm but n exc 5cm in length and not exc 6mm thick complete all as specified and directed. |
| 20 | M&L in repair fibre glass 2mm thick reinforced translucent corrugated sheeting with two corrugations/plain side lap fixed with coach screw and washer in roof, wall etc any colour complete all as specified and directed. |
| 21 | Demolition of cement concrete and paving n exc 15 cm thick in floors and similar work etc complete all as specified and directed. |
| 22 | M&L for 75mm PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in sub base complete all as specified and directed. |
| 23 | M&L for chequered cement concrete tiles coloured glossy finish rubber moulding with mixture of white cement and pigments of size 30cmx30cmx25mm thick set, jointed and pointed in neat cement slurry in fooors incl 20 mm thick screed bed in CM 1:6 incl demolition of existing tiles etc complete all as specified and directed. |
| 24 | M&L for 60 mm coloured machine pressed rubber moulded precast concrete interlocking paver block (ISI Mark) incl any shape and size having double glossy finish top layer with in colour (Red/yellow) M-35 Grade grey cement and pigment incl demolition of existing paver blocks etc. complete all as specified and directed. |
| 25 | All as per item No 24 above but except Paver Blocks complete all as specified and directed. |
| 26 | M&L for sand filling under paver blocks/floors or in foundations including watering and consolidation complete all as specified and directed. |
| 27 | Demolition of Brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 28 | M&L Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 29 | All as per item No 28 above but except bricks complete all as specified and directed. |
| 30 | M&L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) in coping/ bed of drains complete all as specified and directed. |
| 31 | M&L for rendering 15mm thick on fair faces of brick work/ concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 32 | M&L for preparation of newly plastered wall surface and applying two coats of cement base paint over a coat of alkali-resistant primer complete all as specified and directed. |
| 33 | Excavation in trenches n.exc 1.5 m in depth for foundation n.exc. 10 sqm on plan and n.exc 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed. |
| 34 | Returning / filling in layers including spreding, leveling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed. |
| 35 | Removing excavated soil to a distance exc 250m but not exc 500m and depositing where as directed as a level n, exc 1.5m above the starting point complete all as specified and directed. |
| 36 | M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregates) in foundation filling and mass concrete complete all as specified and directed. |
| 37 | S & F of precast I-shaped column of size 2400mm x 200mm x 200mm (prepainted and colour is as per Engr-in-charge), having flange thickness of 60 mm and web thickness 80mm will place on pcc base size 750mmx750mmx100mm, grouted into pit size 600mmx600mmx900mm. using shuttering with concrete ratio 1:3:6, having a cap fixed at top of the column, having 4mm thick high tensile tendom steel 10 Nos in each column which is made of high performance self compacting concrete (SSC) of M-40 Grade, cured under controlled factory conditions, all manufacturing process must comply with indian standards, the curing process must be maintained using RO water and chiller plants for quality assurance, the formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components concrete mix design of IS-9103 with weight of each column at least 185 kg (tolerance limit 1.5%) complete all as specified and directed by Engineer-in-charge.NOTE - (i) PCC of sub base and grouting shall be measured and paid separately under relevant item of BOQ. (ii) Contractor to get the approval of precast factory within 15 days of commencement of work and all precast item will be supplied from single OEM to ensure quality. (iii) Please refer drawing sheet No 1/1 to 1/2 for pillars & panels is enclosed. (iv) Contractor shall upload MoU with precast fabricated manufacturer meeting all the condition and specification as mentioned in CA during the time of bidding. (v) Prior technical evaluation, rep of GE (West) Lucknow will visit to precast factory to verify eligibility criteria of Precast factory of uploaded MOU by bidder. If precast factory given in MOU will not meet eligibility criteria of Precast factory as given in MOU shall be liable to be rejected. (vi) The contractor is adivised to quote their rates as per MOU accordingly. |
| 38 | S & F of precast panel have oval size hollow design (prepainted, colour and design as per Engr-in-Charge) of size 3000mmx750mmx75mm having 8mm dia steel bars in panel which is made of high performance self compacting concrete (SSC) of M-40, cured under controlled factory conditions. all manufacturing process must comply with indian standards, the curing process must be maintained using RO water and chiller plants for quality assurance, the formwork used for casting should be made automobile grade water tight steel enabling the production of highly accurate and consistent components, concrete mix design of IS-9103 with weight of each panel at least 270 kg (depends on design) complete all as specified and directed.NOTE - (i) Contractor to get the approval of precast factory within 15 days of commencement of work and all precast item will be supplied from single OEM to ensure quality. (iii) Please refer drawing sheet No 1/1 to 1/2 for pillars & panels is enclosed. (iv) Contractor shall upload MoU with precast fabricated manufacturer meeting all the condition and specification mentioned in CA during the time of bidding. (v) Prior technical evaluation, rep of GE (West) Lucknow will visit to precast factory to verify eligibility criteria of Precast factory of uploaded MOU by bidder. If precast factory given in MOU will not meet eligibility criteria of Precast factory as given in MOU shall be liable to be rejected. (vi) The contractor is adivised to quote their rates as per MOU accordingly. |
| 39 | M&L for PCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in column footing including necessary form work complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender