Tender For Drinking Water Supply Scheme Under Barjala Binapani Gp Under Beup Fund/ S.H : Construction Of 01 (One) No. Semi Permanent Pump House Of Size (6.00 Mtr X 3.50 Mtr.) At Vaskar Kobra Para Including Laying Od Di, Gi And Pvc Pipe Line, Providin
Tender Overview
Project Description
Tender for Drinking Water Supply Scheme Under Barjala Binapani Gp Under Beup Fund/ S.H : Construction Of 01 (One) No. Semi Permanent Pump House Of Size (6.00 Mtr X 3.50 Mtr.) At Vaskar Kobra Para Including Laying Od Di, Gi And Pvc Pipe Line, Providing Domestic Connection Under The Jurisdiction Of Pwd (Dws) Sub-Division, Jirania During The Year 2026-27.(Group -Ii) (Deposit Work)
BOQ
| Sl. No. | Item Description |
| 1 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200)including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. A) For UPVC pipes in new work. a) All kind of Soils B) For GI/CI/DI pipes in new work. a) All kind of Soils |
| 2 | i) For pipes not exceeding 90 mm dia |
| 3 | ii) For pipes exceeding 90mm dia but not exceeding 300mm dia. |
| 4 | iii) For pipes exceeding 90mm dia but not exceeding 300mm dia. |
| 5 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. A. Class - 3 ( working pressure 6.0 kg / cm2) |
| 6 | i) 50 mm OD |
| 7 | ii) 90 mm OD |
| 8 | iii) 110 mm OD |
| 9 | iv) 140 mm OD |
| 10 | Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 11 | i) 50 mm dia |
| 12 | ii) 90 mm dia |
| 13 | iii) 110 mm dia |
| 14 | iv) 140 mm dia |
| 15 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 16 | i) 50 mm dia |
| 17 | ii) 90 mm dia |
| 18 | Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 19 | i) 90 x 90 mm dia |
| 20 | ii) 110 x 110 mm dia |
| 21 | Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 22 | i) 110 x 90 mm dia |
| 23 | ii) 140 x 110 mm dia |
| 24 | Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part 6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 25 | i) 90 mm dia |
| 26 | ii) 110 mm dia |
| 27 | Providing and fixing C.I. non-return valve of approved quality as per of CPWD specification and direction of the Engineer - in - charge. |
| 28 | i) 100 mm nominal bore |
| 29 | Providing and laying S & S Centrifugally Cast ( Spun ) Ductile Iron Class K-7 Pipes conforming to IS : 8329 as per CPWD specification and direction of the Engineer - in - charge |
| 30 | i) 150 mm dia Ductile Iron Class K-7 pipes. |
| 31 | Providing and laying D.I. specials of class K - 12 suitable for push - on jointing as per IS : 9523 as per CPWD specification and direction of the Engineer - in - charge. |
| 32 | i ) Upto 300 mm dia. |
| 33 | Charges for push-on ( Tyton ) joints to centrifugually ( Spun ) cast iron pipes or ductile iron pipes including testing of joints and including the cost of rubber gasket as per CPWD specification and direction of the Engineer - in - charge. |
| 34 | i) 150 mm dia |
| 35 | Charges for cutting D.I. pipe with steel saw by manual means as per CPWD specification and direction of the Engineer - in - charge. |
| 36 | i) 150 mm dia |
| 37 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. |
| 38 | i) 150 mm dia./ PN - 1.6 |
| 39 | ii) 100 mm dia / PN - 1.6 |
| 40 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge A. External work. |
| 41 | i) 15 mm dia. nominal bore |
| 42 | Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including boring and tapping the main as per CPWD specification and direction of the Engineer - in - charge. |
| 43 | i) 10 mm nominal bore |
| 44 | Providing and fixing G.I. Nipple of medium class as per CPWD specification and direction of the Engineer - in - charge. |
| 45 | i) 15 mm dia 150 mm long |
| 46 | Providing and fixing U.P.V.C. service saddle as per CPWD specification and direction of the Engineer - in - charge. |
| 47 | i) 50 mm dia with 15 mm dia opening |
| 48 | ii) 90 mm dia with 15 mm dia opening |
| 49 | iii) 110 mm dia with 15 mm dia opening |
| 50 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete including earth work as per specification and direction of the Engineer - in - charge (cost of fittings will be paid separately). |
| 51 | i) 15 mm dia |
| 52 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 53 | i) 15 mm dia |
| 54 | ii) 100 mm dia. |
| 55 | Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge. |
| 56 | i) 15 mm dia |
| 57 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. |
| 58 | i) 15 mm dia |
| 59 | Providing and fitting fixing CI bib cock (long handle) as per specification & direction of the Engineer-in-charge. |
| 60 | i) 15 mm dia PVC /plastic bib cock |
| 61 | Providing and fixing G.I. equal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 62 | i) 80 x 80 x 80 mm dia |
| 63 | Providing and fixing G.I. Unequal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 64 | i) 100 x 100 x 80 mm dia |
| 65 | Making road crossing by horizontal boaring for smooth laying of UPVC/CI/DI/GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge. A. By manual means Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender