Educational and Research Institute Boards / Undertakings / PSU Closing in 1 days TDR #58098137

Tender For Repair Work Of Swami Vivekanand Sabhagar, M.L.S University, Udaipur

Issued by Boards / Undertakings / PSU · Udaipur, Rajasthan
Tender Value
14.70 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
1 days left
EMD
29400
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair Work Of Swami Vivekanand Sabhagar, M.L.S University, Udaipur

BOQ

Name of Work:- Repair work of Swami Vivekanand Sabhagar, M.L.S University, Udaipur
Sl. No. Item Description
1Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.
2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
3Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
4Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :25 mm thick.
5Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finish :25 mm thick.
6Providing and fixing Granite stone slab mirrorpolished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Jhunjhunu / Jalore(Red/Choclate/Black/PinkColour)Above 3601 Cm2 Slabs, 15-18mm thick
7Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work Full Edge moulding
8Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing andpolishing complete For area of each slab from 2001 to 5000 Sqcm
9Providing and fixing 1st quality MAT & GLOSSY finished ceramic tile confirming to IS : 13755 and IS: 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).Size 600mm x 600mm, thicknes 7mm to 8mm
10Add extra for Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 , using 5kg. adhesive per sqm of tile area, in average 3mm thickness instead of cement mortar.
11S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws at not exceeding 150mm distance at all heights with all lead and lift with scafolding.
12Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade :Sal wood Grade - I.
13Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A'35 mm thick .Commercial Veneer both side
14Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
15Repair to damaged plaster with high performance curing free, quick setting cement mortar & confirming to ASTM C 1600 in ratio of 1:4 with following properties of cement :Compressive strength of 20 MPa within 4 Hours, Curing free, bond strength of 4 MPa within 24 Hours, Non shrink & Non toxic in following steps- (i) Chopping loose and cracked plaster to required depth, cleaning the exposed surface with wire brush, cleaning of plaster surface with water as necessary and getting dried. (ii) Plastering the surface with above mentioned highperformance cement sand mortar 1:4 upto depth of 25 mm complete with all scaffolding. (iii) No curing has to be done as the high performance cement used should be curing free. (This item is to be used in only emergency situation after decided by Engineer in charge) should be curing free.
16Repair to damaged RCC slabs, beams and columns etc for strengtheing with cement mortar 1 : 2 in following stepsi) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.ii) Applying Epoxy primer on the exposed steel bars.iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush.iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.vi) Cure the plastered surface for 15 days All work including scaffolding etc. complete in all respect.
17Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape,raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
18Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @ 0.253 kg/sqm.b) laying second layer of Fiber glass cloth when the first layer is still green . Overlaps of joints of fiber cloth should not be less than 10 cm .c) Third layer of 1.5 mm thickness consisting of slurry of cement @1.289 kg/sqm mixed with water proffing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will beallowed to air cure for 4 hours followed by water curing for 48hours. The entire treatment will be taken upto 30cm on parapetwall and tucked into groove in parapet all aroundd) fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured
19Providing gola 75x75 mm in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design :
20Finishing with neat cement (punning).
21Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., . The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane.3 mm thick
22Add 18% GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58098137
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 14.70 Lakhs
LAST DATE 27-10-2026
Authority
Authority Name Mohan Lal Sukhadia University
Work Description Tender for Repair Work Of Swami Vivekanand Sabhagar, M.L.S University, Udaipur
Basic Detail
Tender No NIT No 07/26-27 EO MLSU UDAIPUR
Bidding Type Tender
Location
City Udaipur
State Rajasthan
Key Dates
Publish Date 17 Oct 2026
Submission Date 27 Oct 2026
Open Date 28 Oct 2026
Finance
Tender Value 14.70 Lakhs
Tender Fee 590
EMD 29400
Exemption Not Available
Document List
93cac319-3493-4ef3-9489-4325204d21f1.html
BOQ_1071702.xls
FB6.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Oct 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

93cac319-3493-4ef3-9489-4325204d21f1.html

xls

BOQ_1071702.xls

pdf

FB6.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender