Tender For Construction Of 2 Nos Manholes Of Size 1.83 X 1.52 Mtr For 450Mm I/D Reinforced Cement Concrete Np3 Pipe Including Plugging Of Existing Manholes And Pumping Arrangment During Execution Of Work Etc. Complete In All Respect Along Master Road
Tender Overview
Project Description
Tender for Construction Of 2 Nos Manholes Of Size 1.83 X 1.52 Mtr For 450Mm I/D Reinforced Cement Concrete Np3 Pipe Including Plugging Of Existing Manholes And Pumping Arrangment During Execution Of Work Etc. Complete In All Respect Along Master Road Between Sector - 53/54, Gurugram And All Other Works Contigent Thereto. A/C Rs. 9.21 Lakhs
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-Oct-2026 | Extension of date | Date | 28-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Plugging of both side existing M.H`s of master sewer line of various sizes at upstream and downstream for cleaning of blockage and repairing of settled master sewer line with dismantling of RCC slab, placing of jamuna sand bag, providing labour for plugging and cleaning of M.H`s, M.S. Sheet, hiring hydra for lifting of M.S. Sheet, safety equipment etc. complete in all respect. For 450mm to 600mm i/d master sewer line |
| 2 | Pumping arrangement for diversion of flow after plugging and during execution of work for repairing of settled master sewer line with 2 Nos pumps atleast 20 to 50 HP with 3 Gen Set of 62.5 KVA including cost of diesel, panel board, PVC houz pipe as per site requirement, electrician and pump operator round the clock etc. complete in all respect. For 450mm to 600mm i/d master sewer line |
| 3 | [1.PM057] PM057. Hire charges for JCB with bucket capacity more than 0.75 cum with fuel and driver [Rate] |
| 4 | [11.5.1]12 mm cement plaster of mix : 1. 1:2 (1 cement: 2 fine sand) [Through Rate] |
| 5 | [21.121.7]Providing, lowering, laying, cutting, jointing and testing RCC pipe class NP-3 as per IS- 458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with 3 mm thick HDPE Lining and manufactured through vertical viberated casting process with rubber rings ISI marked anti termite confirming to IS 5382 as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting ofconcrete beds and side of trenches, if required jointing with rubber rings intrenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints, cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.45, and item 21.46 including cartage loading and unloading complete in all respect, the internal diametre of the sewer being- Note : E/w to be measured and paidseparately. 7. 450 mm i/d [Through Rate] |
| 6 | [21.28]Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge [Through Rate] |
| 7 | [21.43]Extra over the rate laid down in this schedule for cement concrete work more making and finishing benching and complicated floor work in manholes, including formation of channels and bulldozing and smooth finishing the surface accurately to template. [Through Rate] |
| 8 | [21.93.1]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening [Through Rate] |
| 9 | [3.CA001] CA001. Good earth [Rate] |
| 10 | [34.40]Portable Barricade in Construction Zone Installation of a steel portable barricade with horizontal rail 300 mm wide, 2.5 m in length fitted on a A frame made with 45 x 45 x 5 mm angle iron section, 1.5 m in height, horizontal rail painted (2 coats) with yellow and white stripes, 150 mm in width at an angle of 450, A frame painted with 2 coats of yellow paint, complete as per IRC:SP:55-2001 [Through Rate] |
| 11 | [4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate] |
| 12 | [6.1.2A]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2A. 1:2:4 (1 cement : 2 coarse sand(zone-III) including manufactured sand derived from Recycled concrete aggregate (RCA) up to 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25% ) [Rate] |
| 13 | [6.1.4A]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4A. 1:3:6 (1 Cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA)). [Rate] |
| 14 | [6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate] |
| 15 | [6.26.1]Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) [Through Rate] |
| 16 | [6.29.1]Centering and shuttering including strutting, propping etc. and removal of form work for : 1. Foundations, footings, bases for columns [Through Rate] |
| 17 | [6.29.2]Centering and shuttering including strutting, propping etc. and removal of form work for : 2. Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. [Through Rate] |
| 18 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] |
| 19 | [6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate] |
| 20 | [7.20.1]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate] Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender