Tender For Upgradation Of Play Fields Parks At Various Sports Complexessub Head : Refurbishment, Expansion & Up-Gradation Of Gymnasium, Aerobic, Admin Block, Toilet Block And Corridor Area At Siri Fort Sports Complexestimated Cost : Rs. 1,24,15,123/-
Tender Overview
Project Description
Tender for Upgradation Of Play Fields Parks At Various Sports Complexessub Head : Refurbishment, Expansion & Up-Gradation Of Gymnasium, Aerobic, Admin Block, Toilet Block And Corridor Area At Siri Fort Sports Complexestimated Cost : Rs. 1,24,15,123/-
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.a. All kinds of soil. |
| 2 | Supplying chemical emulsion in sealed containers including delivery as specified. A. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 3 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : a. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level.a. (1 cement : 5 coarse sand (zone-lll) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for.A. Shelves (Cast in situ) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for.A. Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.A. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in.a. Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :a. Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 12 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.A. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 13 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 14 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red.a. Area of slab over 0.50 sqm |
| 15 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 16 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 17 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 18 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 19 | Extra for using glazed vitrified wall tiles of size 1200x600 mm instead of ceramic glazed wall tiles |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.A. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 21 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.A. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 22 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 23 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily Glazed Vitrified tiles Matt/Antiskid finish of sizea. Size of Tile 600 x 600 mm |
| 24 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & anufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily Glazed Vitrified tiles Matt/Antiskid finish of sizea. Size of Tile 600 x 1200 mm |
| 25 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.a. Size of Tile 600x600 mm |
| 26 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.a. Size of Tile 600x1200 m |
| 27 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. |
| 28 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 29 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.a. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent |
| 30 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :a.12.5 mm thick tapered edge gypsum moisture resistant board |
| 31 | 12 mm cement plaster of mix :a. 1:4 (1 cement: 4 coarse sand) |
| 32 | 15 mm cement plaster on rough side of single or half brick wall of mix:a. 1:4 (1 cement: 4 coarse sand) |
| 33 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 34 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : a. Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 35 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | Painting with aluminium paint of approved brand and manufacture to give an even shade: a. One or more coats on old work |
| 37 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 38 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 39 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.A. In cement mortar |
| 40 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.A. For thickness of tiles 10 mm to 25 mm |
| 41 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 42 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin-charge. |
| 43 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.a 15 mm nominal dia Pipes . |
| 45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.a. 20 mm nominal dia Pipes |
| 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall.a. 32 mm nominal dia Pipes |
| 47 | Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length a. 15 mm nominal bore |
| 48 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 49 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 50 | Painting with PU paint including prepration of surface by sanding ,application of base coat of approved brand and approved color to give an evn shade complete as per direction of engineer in charge . |
| 51 | Dismantling of existing maple wood sports/wooden flooring including wooden runners, plywood underlay, and shock pads/EPDM foam (if any), carefully taking out tongue & groove (T&G) planks without damaging the edges, removing nails/screws/clips, sorting, and stacking of serviceable materials within 50 metres lead and disposal of unserviceable materials as per the direction of Engineer-in-Charge. |
| 52 | Providing and fixing thin rim table top wash basin of size 495x395x150 mm without pop waste of standard pattern, cutting and making good the walls and plateform wherever required, complete as per direction of Engineer-in charge. a. model no. JDS-WHT-25909 of make Jaquar or equivalent or betterin cost and specification etc |
| 53 | Providing and fixing CP brass single lever exposed part kit of Single Lever Basin Mixer -chrome with flange & button assembly model no. OPP-CHR-15233NKPM make of Jaquar or equivalent or better in cost and specification etc, complete as per direction of Engineer-incharge. |
| 54 | Providing and fixing single lever concealed body part kit of basin mixer model no. ALD-CHR-441 of make Jaquar or equivalent or better in cost and specification etc, complete as per direction of Engineer-incharge. |
| 55 | Providing & fixing rimless wall hung water closet with PP soft closet slim seat cover hinges, accessories set of mode no. ARS-WHT-39951UFSM complete. i/c paining of fitting & brackets, cutting & making good the walls & hiiks wherever required of make Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-in-charge. |
| 56 | Providing & fixing wall hung water closet's control plate model no. JCP-CHR-152415 of make Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-in-charge. |
| 57 | Providing & fixing wall hung water closet's single piece slim concealed body mode no. JCS-WHT-2400 with automatic flushing cistern with standard flush pipe & C.I. Clamps complete i/c paining of fitting & brackets, cutting & making good the walls & hiiks wherever required of make Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-in-charge. |
| 58 | Providing and fixing C.P. brass toilet paper roll holder with flap with CP brass flange of approved make including fixing with PVC rawl plugs & screws etc. model no. Cat.-ACNCHR-1153 S of Jaquar or equivalent model of approved make all complete as per direction of Engineer-in-Charge. |
| 59 | Providing and fixing C.P. brass automatic soap dispenser, including fixing with PVC raw plugs & screws etc. model no. Cat.-SDR-BLC-DJ0160ASN of Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-inCharge |
| 60 | Providing and fixing S.S. grab bar 680 mm long including fixing with PVC rawl plugs & screws etc. model no. WAC-WHT-BR0600N of Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-in-Charge. |
| 61 | Providing and fixing C.P. brass towel rack of size 600 mm , with brackets fixed to wooden clats / rawl plugs with CP brass screws of approved make etc. complete as per direction of Engineer-in-Charge. Model no. ACN-CHR-1181FHS of make Jaguar or equivalent or better in cost and specification etc . |
| 62 | Providing and fixing C.P. brass Hand shower (Health Faucet) having flexible tube of required length and wall hook of approved make etc. model no. Cat-ALD-CHR-573 of Jaquar or equivalent or better in cost and specification etc,all complete as per direction of Engineer-inCharge. |
| 63 | Providing and fixing C.P. brass Bottle Trap 32mm Size with 250mm x 300 Long Wall Connection Pipes & Wall Flange of approved make etc. model no. Cat.-ALD-CHR-769L300X190 of make Jaquar or equivalent or better in cost and specification etcof approved make all complete as per direction of engineer in charge |
| 64 | Providing and fixing C.P. brass Stainless Steel basin waste of size 32 mm , model no. ALD-CHR-705 of make Jaquar series or equivalent or better in cost and specification etc. complete as per direction of Engineer-in-Charge |
| 65 | Providing and fixing Curved shaped urinal partition with frosted glass of size Size H: 900 W: 450 Thickness: 8mm of approved model no. JSE-CHR-810UC450 make Jaquar series or equivalent or better in cost and specification etc. complete as per direction of Engineer-in-Charge |
| 66 | Providing and fixing C.P. brass double hook including fixing with PVC rawl plugs & screws etc. model no. Cat.-CAN CHR-1161 N of Jaquar or equivalent or better in cost and specification as per direction of Engineer-in-Charge. |
| 67 | Providing and fixing C.P. brass paper towel dispenser with c/z including fixing with PVC rawl plugs & screws etc. model no. Cat.-PTD-SAP-DT0106CSN of Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-inCharge |
| 68 | Providing and fixing C.P. brass bolt touch free infrared hand dryer including fixing with PVC rawl plugs & screws etc. model no. Cat.-HDR-SSF-AK2803D of Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-in Charge |
| 69 | Providing and fixing single lever exposed part kit of shower , model no FUP-CHR-29079NKPM of make Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-in Charge |
| 70 | Providing and fixing C.P. brass overhead shower model no OHS 1613 with shower arm 20mm dia and 450 mm long model no SHA-CHR-479L450 , of make Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-in Charge |
| 71 | Providing and fixing single lever conceled body for the shower model no ALD-CHR-079N ,including fixing with PVC rawl plugs & screws etc of make Jaquar or equivalent or better in cost and specification etc, all complete as per direction of Engineer-in Charge |
| 72 | Providing and fixing Urinal pot With Fixing Accessories, having pre & post flushing model no.-URS-WHT-13263 of make Jaquar or equivalent or better in cost and specificificaion , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification |
| 73 | Providing and fixing Urinal Sensor With fixing Accessories, Sensor Flushing Valve for Urinal with Complete Kit model no. SNR-STL-51077E4MAD Jaquar or equivalent or better in cost and specificificaion complete all as per manufacturers specification and direction of Engineer-incharge |
| 74 | Proiding and fixing tile insert shower drain size chanel of minimum size 100x100x32 mm and minimum weight 400 gm (+5%) built up with 1.2mm thick 304 Grade stainless steel , specially desinged for tiles up to 13 mm thickness, came with a drain frame/drain cover,tray/drain body , cockroach etc all complete as per direction of Engineer in charge |
| 75 | Proiding and fixing tile insert shower drain size chanel of minimum size 800x100x85 mm and minimum weight 1.96 kg (+5%) built up with 1.2mm thick 304 Grade stainless steel , specially desinged for tiles up to 13 mm thickness, came with a drain frame/drain cover,tray/drain body , cockroach etc all complete as per direction of Engineer in charge |
| 76 | Providing and fixing Locker system -3 tier locker made of heat, bacteria, water, chemical, scretch and impact resistant,made of 03 mm (sides and back portion) and 09 mm (Top ,bottom,Shelves) thick solid compact laminate pannel i/c doors self side panel, top and bottom panels finished with approved texture ,shade as per the detail drawing and and as per the IS 2046 (Indian standard ) . the compact item should have Green guard certificate . It should be Anti bacteria. This also include providing and fixing in possition necessary hardware made of alluminium(Grade -6063-T6) & Stainless steel(Grade 304) (1) Cam lock (2) hinges (3) Front section (4) Back section (50 Infill section (6) Rubber linning (7) screw and bolt . Lockers shall be constructed with 4 aluminium interlocking supporting frame work making it strong nd rigid . Standard dimensions of lockers unit shall be width 300 mm x depth 450 mm x height 1800 mm. (a) Locker system -3 tier of make Greenlam Sturdo. Marino or equivalent. |
| 77 | Providing and fixing Locker system -2 tier locker made of heat, bacteria, water, chemical, scretch and impact resistant03 mm (sides and back portion) and 09 mm (Top ,bottom,Shelves ) thick solid compact laminate pannel i/c doors self side pane, top and bottom panels finished with approved texture ,shade as per the detail drawing and and as per the IS 2046 (Indian standard ) . the compact item should have Green guard certificate . It should be Anti bacteria(Shree Ram House). This also include providing and fixing in possition necessary hardwaremade of allumonium(Grade -6063-T6) & Stainless steel(Grade 304) (1) Cam (2) hinges (3) Front section (4) Back section (50 Infill section (6) Rubber linning (7) screw and bolt . Lockers shall be constructed with 4 aluminium interlocking supporting frame work making it strong nd rigid . Standard dimensions of lockers unit shall be width 300 mm x depth 450 mm x height 1200 mm.(a) Locker system -2 tier of make Greenlam Sturdo. Marino or equivalent. |
| 78 | Providing and fixing bench ( make of merino or greenlam or equivlent ) Made of MS Frame and top made of heat, bacteria, water, chemical, scretch and impact resistant 18 mm thick solid compact laminate pannel with overall size of bench as 1200x450x450 ,standard mild steel accessories etc as per drawings and specifications and as directed by Engineer-in-charge. |
| 79 | Providing and fixing change room cubicles ( includes 600 mm door size width)of reputed make like Greenlam, Merino Formica ( R) or equivalent made up of thermosetting resign treated high pressure ,self-supporting decorative compact laminates with permanently incorporate anti-bacterial agents during manufacturing .Compact board should be resistance to water immersion through permissible increase on thickness and mass 1.35kg/cm3 and fulfilled the criteria of FSC and Green Guard Gold Certification and manufactured under EN438-2&3:2005 standard. 12mm thick compact board should be Moisture resistant, Impact resistant, termite resistant, Scratch resistant, Weather and climatic shock resistant. Finish of compact laminates should be suede finish which includes door, pilasters and intermediate panels finished with approved texture/shades as per IS2046 and fulfilled the criteria of fire retardant under BS-476/9 7 and EN438-6 with classification of BS1D0 standard, all complete as per manufacturer’s specification and as per the direction of Engineer-in-charge.Hardware and Fixing:- All hardware, fittings and accessories as per manufacturer's specifications shall be in stainless steel grade SS 304. The pilasters are anchored to the flooring using SS 'L\\" angles and covered with SS plates all of grade 304. To ensure that there is no lintel at the top.Accessories :- Standard accessories include SS Hinges, SS door knob, SS thumb turn indicator, SS coat hook, SS shoe box and SS channels etc. all in SS 304 grade as per manufacturer’s specifications.Floor mounted Cubicles shall be of size as under:Door size - 600mm x 1800 mm. There will be no section above top of door.-(a) Toilet cubicles, change room cubicles & shower rooms of size 1580mmx1050mmx2100mm (Size may be vary according to requirement) (Height is including 100mm gap form bottom). |
| 80 | Providing and laying high-performance, multi-layered heterogeneous indoor sports vinyl flooring of approved make and shade (Responsive Active Sport / Polaris or Wonderfloor Braavo Elite engineered for high-impact aerobic and fitness applications.The flooring system shall have a minimum total thickness of 6.5 mm with a pure PVC transparent wear layer of not less than 0.7 mm to 1.0 mm, reinforced with a high-performance Polyurethane (PUR) factory surface treatment for scratch, scuff, and sweat resistance. The core construction must incorporate an embedded, bi-directional fiberglass grid/tissue matrix to provide absolute dimensional stability against expansion or contraction. The backing must consist of a high-density, closed-cell PVC cushion foam engineered to provide point-elastic shock absorption (minimum 25-30% energy absorption conforming to EN 14904 standards) and a minimum impact sound insulation of 15 dB to 19 dB.The work shall include thoroughly cleaning the existing base sub-floor, removing all dust, laitance, oil, and grease. The base concrete/IPS surface must be leveled by applying a 2mm to 3mm thick cementitious self-levelling compound (such as Ardex, Dr. Fixit, or equivalent approved make) to achieve a perfectly smooth, patch-free finish. The flooring shall be fixed permanently using high-strength, low-VOC acrylic emulsion flooring adhesive (such as Fevicol SR 908 / Eurocol or equivalent) applied uniformly with a notched trowel. All joints and seams must be grooved and thermowelded seamlessly using matching PVC welding rods and a hot-air welding gun, followed by flush-trimming the joints to ensure a completely water-tight, monolithic, hygienic workout surface. |
| 81 | Providing and laying heavy-duty, high-density Laminated Rubber Flooring Tiles of make Fab Flooring or approved equivalent make , having a finished overall thickness of 25 mm. The tiles shall be of modular square dimensions measuring 20\\" x 20\\". The product must feature a factory-finished, non-porous laminated top surface layer in a grey color profile or desired to ensure high wear resistance, sweat/moisture resistance, and ease of maintenance. The core bottom layer must consist of premium vulcanized impact-absorbing rubber compound suitable for heavy free-weight and gym applications. The item is to be installed seamlessly over a prepared leveled sub-floor using recommended flooring adhesives, strictly conforming to the manufacturer's installation guidelines ,all complete as per direction of Engineer-in Charge |
| 82 | Providing and fixing distortion-free commercial-grade wall mirror,consisting of 5 mm thick silver-coated float glass mirror panels of approved make (Saint-Gobain (Miralite Pure) / Modiguard). The mirror assembly shall be mounted systematically over a rigid, moisture-impervious backing substrate made of 8 mm thick High-Density High-Moisture Resistance (HDHMR) board (Action Tesa / Greenpanel), which is mechanically anchored to the masonry walls/columns using high-tensile counter-sunk fasteners The individual glass panels shall be permanently bonded to the HDHMR substrate using specialized neutral-cure, non-corrosive mirror-fix silicone adhesive applied in vertical ribbons, reinforced with heavy-duty double-sided spacer tape.Note :The rate shall be inclusive of all scaffolding, safety arrangements ,complete in all respect as per the direction of Engineer-in-Charge. |
| 83 | Providing and applying premium, high-durability, weather-resistant Exterior Texture Plaster / Paint system of Asian Paints (Ultima Allura / Apex Duracast series), Kansai Nerolac (Excel Texture series), or Berger Paints (Solitaire / Florentina / Ruff & Tuff series), texture profile, and shade over external walls, elevations, pillars, and columns at all heights and levels, including preparing the substrate, structural scaffolding, and safety systems. Surface Preparation & Priming: The wall surface shall be thoroughly cleaned using a high-pressure water jet or mechanical wire brushes to remove all loose mortar, laitance, dust, dirt, and existing organic growth. All structural hairline cracks must be filled using approved exterior crack-filler compound. One coat of specialized weather-shield or water-proofing exterior primer of approved make shall be applied uniformly as an undercoat base layer. Texture System Material & Execution Matrix: The texture system shall consist of pure acrylic, silicone-resin, or silicone-silicate base matrix polymers, loaded with graded quartz aggregates, marble crystals, or mineral flakes, applied systematically using stainless steel trowels, spatulas, honeycomb rollers, or mechanical hopper spray guns to achieve the designated design architectural pattern. The system must possess high water-vapor permeability, superior UV-light color retention, and integrated anti-algae/anti-fungal biocides .Note :The rate shall be inclusive of all scaffolding, safety arrangements for working for external walls, elevations, pillars, and columns at all heights and levels, including preparing the substrate,complete in all respect as per the direction of Engineer-in-Charge. |
| 84 | Jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS: 13592 suitable for rubber ring joints, including all necessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soil , suspended from floor under false ceiling or embedding the pipes laid under floors / building after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by Engineer-in-charge.(a) 110 mm Diameter |
| 85 | Providing and fixing factory made system aluminum with glazing for Door/Windows having profile of aluminium alloy & temper of EN AW 6060 T 66/6063 confirming to EN 573-3 & Mechanical Properties (Strength, Corrosion, Resistance) confirming to standard EN 755-2, extrusion tolerances confirming to EN-12020-2 of Schuco System Aluminium /fenista system aluminium/ or equivalent with glazing of 10 mm thick Single Glazing Clear Toughened Glass of make Saint Gobin or equivalent designed and engineered to conform to structural wind load requirements under IS 875 (Part III) standards for Delhi .The window frame and structural mullion sections shall consist of premium 74 mm structural profile blocks (AC39PT02 matrix) factory-coated in Diamond Grey Textured finish or as per required shade on both sides. System must be fitted with internal square bead glazing with peroxide cured EPDM gasket with tolerances in accordance with DIN ISO 3302-1 and plastic glazing clips to compensate for tolerances. Maximum acceptable gap between glazing beads is 0.2 mm. The rate includes masonry packing clips ,special arched curve fabrication profile charges, thermal welding of joints, internal steel reinforcements, specialized structural fasteners, and premium weatherproof sealants. etc as per drawings and specifications and as directed by Engineer-in-charge. |
| 86 | Providing and fixing factory made system aluminum with glazing ,engineered in an Arched Fixed configuration for exterior elevations of required size in a single-panel Fixed configuration having profile of aluminium alloy & temper of EN AW 6060 T 66/6063 confirming to EN 573-3 & Mechanical Properties (Strength, Corrosion, Resistance) confirming to standard EN 755-2, extrusion tolerances confirming to EN-12020-2 of Schuco System Aluminium /fenista system aluminium/ or equivalent with glazing of 12 mm thick Glazing Clear Toughened Glass of make Saint Gobin or equivalent designed and engineered to conform to structural wind load requirements under IS 875 (Part III) standards for Delhi . System must be fitted with internal square bead glazing with peroxide cured EPDM gasket with tolerances in accordance with DIN ISO 3302-1 and plastic glazing clips to compensate for tolerances. Maximum acceptable gap between glazing beads is 0.2 mm. The rate includes masonry packing clips ,special arched curve fabrication profile charges, thermal welding of joints, internal steel reinforcements, specialized structural fasteners, and premium weatherproof sealants. etc as per drawings and specifications and as directed by Engineer-in-charge. |
| 87 | Providing and fixing of Expanded Metal Mesh lay-in ceiling system using GI grid work with Main Runners of size 15mm X 38mm X 3600mm X0.3mm and Cross Runners of Size 15mm X 38mm X 1200mm X0.3mm and 15mm X 38mm X 600mm X0.3mm which snap locked in with each other forming a 600 X 1200mm grid work. The suspension system comprises a Raw plug fixed to the true ceiling and mend to 4mm GI rod with butterfly clip arrangement which holds the Main runners at every 1.2m intervals. Finally expanded Metal Mesh Lay In Tiles of Size 595mmX1195mmX1.2mm (T) are laid upon the formed grid. The price should include the cost of making any cuts and openings for lights and other fittings with custom border Frames to facilitate proper seating or services on the mesh tile. The end tiles are to be tailor made as per site conditions framed all side and seated between the wall angle and T grid to finish the ceiling ,all complete as per drawings, specification and direction of the Engineer in Charge |
| 88 | Providing and fixing modular workstation partitions of 50mm to 60mm thickness and up to 1200mm height. The framework shall be made of extruded aluminium powder-coated sections. The lower portion (below worktop) shall be finished with minimum 9mm thick Pre-Laminated Particle Board (PLB) and the upper portion finished with fabric pin-up board / magnetic whiteboard / clear glass as per approved design. The rate includes inbuilt wire management raceways at desk and skirting levels. |
| 89 | Providing and fixing workstation table tops made of 25mm thick Pre-Laminated Particle Board (PLB) (Exterior Grade) conforming to IS:12823. All exposed edges to be sealed with 2mm thick PVC edge banding tape using hot melt glue. The table top shall be supported on partition frames or powder-coated MS legs as per site layout, including necessary heavy-duty brackets and hardware. |
| 90 | Providing and placing 3-drawer mobile pedestal unit of approximate size 400mm (W) x 450mm (D) x 650mm (H). Made of 18mm thick PLB with PVC edge banding. Includes one pencil drawer, one box drawer, and one file drawer operating on heavy-duty telescopic channels, complete with central locking mechanism, handles, and lockable castors. |
| 91 | Providing and fixing sliding ABS plastic or powder-coated metallic Keyboard tray with in-built mouse pad, mounted under the worktop on heavy-duty telescopic channels. |
| 92 | Providing and placing mobile CPU trolley made of heavy-duty powder-coated MS sheet or high-grade ABS plastic, equipped with lockable castors and adjustable width mechanism. |
| 93 | Less GST Correction factor @ 0.027 on DSR items from 01 to 49 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender