Agriculture Boards / Undertakings / PSU Closing in 11 days TDR #58097900

Tender For Armo:Improvement Of Power Supply & External Security Lighting Along With Renovation & Wiring For The Proposed Divisional Office Lucknow Inside Godown E1 At Fsd Talkatora Under Do Lucknow.

Issued by Boards / Undertakings / PSU · Lucknow, Uttar Pradesh
Tender Value
98.13 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
11 days left
EMD
1.96 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Armo:Improvement Of Power Supply & External Security Lighting Along With Renovation & Wiring For The Proposed Divisional Office Lucknow Inside Godown E1 At Fsd Talkatora Under Do Lucknow.

BOQ

Name of Work:- ARMO:Improvement of Power Supply & External Security Lighting along with Renovation & Wiring for the proposed Divisional Office Lucknow inside Godown E1 at FSD Talkatora under DO Lucknow.
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
23 X 10 sq. mm
33 X 4 sq. mm
43 X 2.5 sq. mm
5Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Confoming to relevent BIS/IS standard or equivalent)a) 25mm
6Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
7Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
8Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
9Single pole
10Double pole
11Supplying and fixing of following rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple Pole & Neutral 63A
1270 Watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120lm/Watt).Supplying, Installation, Testing & Commissioning of 70Watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95,IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Color Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C).
13Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required conforming to relevant BIS/IS codes.
14Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Confoming to relevent BIS/IS standard or equivalent)
155/6 amps switch
1615/16 amps switch
173 pin 5/6 socket outlet
186 pin 15/16 socket outlet
19Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required. (Confoming to relevent BIS/IS standard or equivalent)
20Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Confoming to relevent BIS/IS standard or equivalent)
2112 Module (200mmX150mm)
226 Module (200mmX75mm)
23Supply of 1200 mm sweep ceiling fan suitable for 230 V ±10%, 50 Hz single-phase AC supply, complete with energy-efficient motor (as per BEE norms), aerodynamically balanced aluminium blades, double ball bearing assembly for smooth and silent operation, minimum air delivery of 210 CMM, and rated speed of about 300–320 RPM. The fan shall be provided with powder-coated finish, rust-resistant body, thermal overload protection, and shall conform to relevant IS standards (IS: 374). The item includes supply of down-rod, shackle assembly, canopy, terminal block, and all standard accessories, complete in all respects as approved by the Engineer-in-Charge.
24Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
25Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C
2636 Watt LED Panel light 2x2 ft. (System lumen efficacy ≥105<120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
27Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size as per direction in charge.
283.5X70 sqmm
293.5X50 sqmm
303.5x35 sqmm
314x25 sqmm
324X16 sqmm
334X10 sqmm
342X10 sqmm
35Supplying and fixing of light class G.I. pipe of 50 mm dia.(nominal) 3metres length along the pole for protection of underground cable as required.(conforming to IS-1239 part 1 (2004) or equivalent)
36Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
37Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
38Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (conforming to IS 12943 (1990) or equivalent)
393.5X50 sqmm (35mm)
403.5x35 sqmm (32mm)
414x25 sqmm (28mm)
424X16 sqmm (28mm)
432X10 sqmm (19mm)
44Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (Confoming to relevent BIS/IS standard or equivalent)
45Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. (Confoming to relevent BIS/IS standard or equivalent)
46Supplying , installation , testing and commissioning of cubical type panel with size (2.5x1.5x.4 Mtr) suitable for operation at 415 (+/-) 6% Volts,50Hz,3 Phase 4 Wire system made out from CRCA sheet steel 2.0 mm and covers shall be cold rolled sheet thickness not less than 1.6mm fabricated factory finished followed-42 by powder coated painting & provided with gaskit to make dust vermin proof degree of IP , hinged type openable door , loaking arrangement , detachable gland plate , connection , interconnections with suitable size (400 Amp capacity) 4 strip high conductivety elctrical aluminium (ALU) busbar codifies in red,yellow,blue and black colour and PVC insulated copper conductor cable 1100Volt grade for internal wiring including providing and fixing digital type Ampere meter, Voltmeter, Indication LED lamp, Selector switch,Labeling comprise white letters on black background including foundation works etc as required with following:-(Confoming to relevent BIS/IS standard or equivalent)1) MCCB 320Amps 36KA-01No 2) MCCB 250Amps 36KA-05No 3) MCCB 200Amps 36KA-02No 4) MCB DP 40 Amps -02 Nos 5) MCB TPN 63 Amps -02 Nos 6) 4 strip AL Busbar 400Amp- 01 Set
47Supplying , installation , testing and commissioning of cubical type,inverted V shaped top, outdoor feeder pillar panel with size (1.0x1.0x.4 Mtr) suitable for operation at 415 (+/-) 6% Volts,50Hz,3 Phase 4 Wire system made out from CRCA sheet steel 2.0 mm and covers shall be cold rolled sheet thickness not less than 1.6mm fabricated factory finished followed-42 by powder coated painting & provided with gaskit etc. to make dust & vermin proof degree of IP ,Weather Proof, hinged type openable door , loaking arrangement , detachable gland plate , connection , interconnections with suitable size (200 Amp capacity) 4 strip high conductivety elctrical aluminium (ALU) busbar codifies in red,yellow,blue and black colour and PVC insulated copper conductor cable 1100Volt grade for internal wiring including providing and fixing digital type Ampere meter, Voltmeter, Indication LED lamp, ,Labeling comprise white letters on black background including foundation works etc as required with following:- (Confoming to relevent BIS/IS standard or equivalent) 1) 4P MCCB 200 Amps.36KA-01 Nos 2) 4P MCCB 160 Amps.36KA-02 Nos 3) 4P MCCB 100 Amps.36KA-01 Nos4) 4P MCCB 63 Amps.30KA-01 Nos5) MCB DP 40 Amps -02 Nos6) TPN MCB 63Amp-02 Nos7) 4 strip AL Busbar 150Amp- 01 Set
48Supply and Fixing of 7 mtrs single section Hot dip Galvanized(as per BS EN ISO 1461) octagonal Street light pole (specification not less than, top dia 70 mm, Bottom dia 130 mm & base plate 220mm*220mm, 12 mm thickness IS 2062, 4 Nos. of \\"J'\\" type 20mm dia.,600mm length, with projected length of 125mm, Foundation bolts) having 3 mm thickness, of grade S355 and a vandal resistance, water proof door opening of approximate 400-500mm length at an elevation of 450-500mm from base plate for cable connection and including of GI bracket (of minimum 1000 mm length each from pole) supporting to min 02 street lights, on RCC foundation grade- M20 with base of depth 1200 mm including 200-250 from Free Ground level and width of 400-450 mm including the cost of foundation bolts, excavation and back filling complete in all respects as required as per relevant BIS/IS standards as per the direction and approval of engineer-in-charge .
49Supplying and laying of following size HDPE pipe(PN 6, PE 63) ISI marked along with all accessories like socket, bend, couplers etc. as per latest standard IS Code, Part II complete with fitting and cutting, jointing etc. Direct in ground (75cm below ground level)including excavation and refeling the trench but excludingsand cushioning and protective covering etc.complete as requied. 90 mm dia (OD=90 mm & ID=76 mm nominal)
50Supply , Installation, of suitable size 3mm phenolic laminated sheet having 1 nos. terminal having 5 point for 3 phase, 1 netrual & 1 earth on and 1 no. SP MCB 5/6A , interconnection etc are required.
51120 Watt LED Street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy≥105<120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED Fixture powder coated pressure die cast aluminium body with driver as per requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD< 10% as per IEC 61000-3-2, P.F. ≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 °K / 4000 °K / 5700 °K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching ) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105<120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90 °C).
52Supplying and drawing of Flexible PVC round insulated copper cable of following size a) 3 X 1.5 SQMM
53Supplying and laying of 40mm DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct inground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
54Dismantling of over head lines comprising of copper/ABC Cable/ aluminium overhead conductor, G.I. wire, cross arms, insulators etc. as required.
55Dismantling of pole/ street light standard/ strut embedded in brickballast foundation etc. as required.
56Demolishing Cement Concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer In-charge. Nominal concrete 1:3:6 or richer mix (including equivalent designh mix)
57Providing, laying and fixing of 50 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings as required (Confoming to relevent BIS/IS standard or equivalent)
58Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
59Supplying, Installation, Testing and Commissioning of Inverter Type- Cooling only 4.0 TR with 5 Star BEE Rating Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping withinsulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required. Inverter Type- Cooling only 4.0 TR with 5 Star BEE Rating
60Supply of Exaust Fan 225/300 mm sweep
61Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
62Credit for dismantelled/damaged items:
63Aluminium Scrap (i.e., ABC Cable etc.)
64Iron Scrap (Old panel, poles, etc.) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58097900
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 98.13 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Armo:Improvement Of Power Supply & External Security Lighting Along With Renovation & Wiring For The Proposed Divisional Office Lucknow Inside Godown E1 At Fsd Talkatora Under Do Lucknow.
Basic Detail
Tender No UP/EM/13/ARMO/2026-27
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 16 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value 98.13 Lakhs
Tender Fee Ref. Documents
EMD 1.96 Lakhs
Exemption Not Available
Document List
89965f24-70d4-468c-b5d3-a35bfe175073.html
BOQ_978172.xls
MTF_Talkatoran.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

89965f24-70d4-468c-b5d3-a35bfe175073.html

xls

BOQ_978172.xls

pdf

MTF_Talkatoran.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender