Tender for Provision Of Temporary Shed For Maintenance Requirement At Air Force Station Arjan Singh Under Ge (P)(Af) Panagarh

BOQ

Name of Work:- PROVISION OF TEMPORARY SHED FOR MAINTENANCE REQUIREMENT AT AIR FORCE STATION ARJAN SINGH UNDER GE (P)(AF) PANAGARH
Sl. No. Item Description
1M & L for surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft and loose soil ( bushes, grass and jungles to be cleared with surface excavation.) complete all as specified and as directed.
2M & L for excavating over areas not exc 1.5m deep and getting out in soft and loose soil complete all as specified and as directed.
3M & L for excavating over areas exc 1.5m deep and n exc 3.0m deep and getting out in soft and loose soil complete all as specified and as directed.
4M & L for excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation, etc or laying cables etc and getting out in soft/loose soil complete all as specified and as directed.
5M & L for returning, filling in, including spreading, leveling, watering and well ramming in soft/loose soil in layers n. exc 25 cm complete all as specified and as directed.
6M & L for removing excavated material / soil from site to a distance not exc 50m and depositing, where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
7M & L for removing excavated material / soil from site to a distance exc 100m but n exc 250 m and depositing, where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
8M & L for hardcore of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface with broken stone and boulders as in plinth protection & hard standing complete all as specified and as directed.
9M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
10M & L for Plain Cement concrete (1:2:4) Type B1, using 20 mm graded stone aggregate as in copings, drain and like including necessary form work wherever required complete all as specified and as directed.
11M & L for extra for forming fair finished drain or channel 25 cm inner girth in cement concrete using extra cement including forms and moulds complete all as specified and as directed.
12M & L for Plain Cement Concrete (1:4:8) Type D2 using 40 mm graded stone aggregate as in foundation filling, mass concrete and like etc complete all as specified and as directed.
13M & L for Plain Cement Concrete (1:3:6) Type C2 using 40 mm graded stone aggregate as in foundation filling, mass concrete or in plinth protection and like etc complete and likecomplete all as specified and as directed.
14M & L for RCC (Design Mix M-25) using 20mm graded crushed stone agg as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, and mass concrete and like etc complete all as specified and as directed.
15M & L for RCC (Design Mix M-25) using 20mm graded crushed stone agg as in column, pillar, piers and like etc complete all as specified and as directed.
16M & L for RCC (Design Mix M-25) using 20mm graded crushed stone agg as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and as directed.
17M & L for RCC (Design Mix M-25) using 20mm graded crushed stone agg as in Chajjas and like etc complete all as specified and as directed.
18M & L for Brickwork using sub class 'B' old size fly ash bricks built in CM 1:6 straight or curved on plan exe 6mtr mean radius complete all as specified and as directed.
19M & L for Brickwork using sub class 'B' old size fly ash bricks built in CM 1:4 straight or curved on plan exe 6mtr mean radius complete all as specified and as directed.
20M & L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete (1:2:4), type B-0, with and including applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cum per sqm complete all as specified and as directed.
21Supply only Integral waterproofing compound
22M & L for Use & waste for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work and finished the surface rough complete all as specified and as directed.
23M & L for Use & waste for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping ) and finished the surface rough complete all as specified and as directed.
24M & L for Use & waste for formwork to sides of pillars, posts, struts, piers, columns and stanchions and finished the surface rough complete all as specified and as directed.
25M & L for Use & waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC / PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide and finished the surface rough complete all as specified and as directed.
26M & L for 10mm dia and above MS TMT bar as in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing clips complete all as specified and as directed.
27M & L for 6 mm dia and over upto 10mm MS TMT bar as in stirrups, spacers and binders complete all as specified and as directed.
28M & L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
29M & L for 1.60 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, complete all as specified and as directed.
30M & L for 25mm thick cement concrete (1:2:4) type B-1, (using 20mm graded stone aggregate) as in sub of floors complete all as specified and as directed.
31M & L for 20-22mm thick Machine cut kota stone slab as skirting over cement plaster base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick screed bed or bedding layer of cement mortar CM 1:4 complete all as specified and as directed.
32M & L for 20-22mm thick Machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed or bedding layer of cement mortar CM 1:4 complete all as specified and as directed.
33M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with Grey Cement and Pigment complete all as specified and as directed.
34M & L for 75 mm thick Cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection including joint filling with bitumen and sand in the ratio (1:2), finish the surfaces even and smooth with using extra cement complete all as specified and as directed.
35M & L for 3 mm thick (minimum) APP based Polymeric membrane minimum weighing 3 Kg per Sqm and reinforced with polyester non woven fabric (wt not less than 150 gm per sqm) laid on primed surface by forced application complete all as specified and as directed.
36M & L for applying a coat of approved bitumen primer @ 0.40 litre/Sqm over concrete surface complete all as specified and as directed.
37M & L for applying Bituminous aliminium paint @ 0.10 liter/sqm on Roof surfaces over APP Membrane complete all as specified and as directed.
38M & L for 10 mm thick plastering with WPC as per manufacturar instrctions on concrete roof surface in CM 1:3 finished the surfaces even and smooth without using extra cement complete all as specified and as directed. Note :- WPC will be measured and paid separatelly as \\"Supply\\" only.
39M & L for 15 mm thick plastering on external surfaces of wall in two layers (inner layer shall be 10mm thick and outer layer shall be 5mm thick with WPC as per manufacturar instrctions) on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and as directed.e :- WPC will be measured and paid separatelly as \\"Supply\\" only.
40M & L for 15 mm thick plastering on Internal surfaces of wall on fair faces of brick work or concrete surfaces in CM 1:6 and finished the surface fair and even complete all as specified and as directed.
41M & L for 5 mm thick plastering of ceiling concrete surfaces in CM 1:3 and finished the surface fair and even complete all as specified and as directed.
42M & L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint (Camouflage Paint ) over and including a coat of alkaline resistance primer on eternal surfaces of wall complete all as specified and as directed.
43M & L for preparation of newly plastered surfaces of wall and applying two coats of Oil Bound Distemper over and including a coat of alkaline resistance primer on internal surfaces of wall complete all as specified and as directed.
44M & L for preparation of newly plastered surfaces of wall and applying three coats of white wash on ceiling complete all as specified and as directed.
45M & L for preparation of new steel surface of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
46Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing to a distance exc 100 m but nexc 250 m complete all as specified and as directed.
47M & L for flame proof surface point wiring with PVC insulated 1100 volts grade 1.5 Sqmm single core stranded copper condctor FRLSH cable drawn in and including surface mounted ERW stove enamelled steel conduit not less than 20 mm dia with and including flame proof bends and elbows couplers bell mouth reducer junction box all as per relevant IS and type tested/approved by CMRI Dhanbad fixed with backed distance saddles and elevated MS spacer plate fixed with nettle fold GI screws along with 1.5 Sqmm PVC insulated soild stranded copper conductor FRLSH 1100 volts as earth continuity conductor connected to common earth dolly all as specifide for one light point /exhaust fan point controlled by one flame proof rotatory switch complete all as specified and as directed.
48S & F for switch flame proof rotary type with terminating box in LM 6,10 A single pole 230 V complete all as specified and as directed.
49S & F for flame proof socket & plug and switch combined rotary type with termination box LM 6 16 A single pole 230 V complete all as specified and as directed.
50S & F for LED bldg security light fitting not less than 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, bracket with clamp of switable size complete with minimum IP 65 protection complete all as specified and as directed.
51S & F for flame proof stand fan (Explosion proof /Exd /PESO & CIMER approved industrial type, heavy duty,LM 6, Non sparking) of 450 mm sweep single phase 230 volt, confirming to IS/IEC standared complete all as specifieed & as directed.
52S & F for weather proof, flame proof MCB DB of cast aluminium alloy LM -6 consisting of MCB TPN 63 Amps, 10 KA-01 No as incommer and MCB SPN 6 Amps -03 No MCB SP 10 Amps - 02 Nos MCB SP 16 Amps -01 Nos as out going complete all as specifed and as dircted.
53M & L for Wiring for circuit/submain wiring drawn into and including steel conduit of appropriate size alongwith copper wire 2x1.5 sq. mm +1x1.5 sq. mm earth wire of FRLSH PVC insulated stranded copper conductor, single core cable in surface as required. (2x1.5 sq. mm +1x1.5 sq. mm earth wire and steel Conduit shall be measured as 1 run) complete all as specifed and as dircted.
54S & F for LED light fitting 2 X 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable and flexible steel conduit with suitable size complete all as specifed and as dircted.
55Supply, laying and testing cable LT XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables ( heavy duty ) with stranded aluminium conductor 1100 volts grade of size 16 sq mm 4 core complete all as specifed and as dircted.
56Supplying and laying Bricks; common burnt clay building bricks, sub-class ‘B’ as cable protection complete all as specified and as directed.
57M & L for providing sand cushioning for protection of UG cable (8 cm deep before laying & 15 cm above the top edge of cable after laying) in trenches with dry (coarse) sand approved quality including filling, spreading and punning down to desired thickness complete all as specified & as directed. NOTE : Punned thickness only shall be considered for payment purpose.
58M& L for 40 mm bore galvanized iron tubing light grade with all fitting laid in trenches /wall /floor /under road /culvert for protection of cable including providing fixing clamps, bolts and nuts of suitable size as required comlete all as specified and as directed. Note: Excavation, earth work shall be measured and paid under relevent items as required separately.
59M & L for boring of holes under road, pavement, hard standing by trenchless technology method and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure comlete all as specified and as directed.
60Supply, install, testing and commissioning out door type cubical LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB amps rated to MCCB input and MCCB/MCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 25 x 25 x 5mm duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- Please Enable Macros to View BoQ information
61Supply, install, testing and commissioning out door type cubical LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB amps rated to MCCB input and MCCB/MCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 25 x 25 x 5mm duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58096399
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39.40 Lakhs
LAST DATE 13-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Temporary Shed For Maintenance Requirement At Air Force Station Arjan Singh Under Ge (P)(Af) Panagarh
Basic Detail
Tender No 8017/E8
Bidding Type Tender
Location
City Bardhaman
State West Bengal
Key Dates
Publish Date 17 Oct 2026
Submission Date 13 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 39.40 Lakhs
Tender Fee 500
EMD 78800
Exemption Available
Document List
4fd7b7a2-9f8b-4a27-a18f-97359ff8ba4d.html
BOQ_891051.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.