Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #58096380

Tender For Repair/ Maintenance Of Lt Panel Boards, Switch Gears, Earthings And Connected Misc Works Etc At Electric Supply Installation At installation Dronacharya Under Ge Fort Kochi

Issued by Statutory Bodies & Commissions/Committees · Ernakulam, Kerala
Tender Value
13.75 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
8 days left
EMD
27500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Lt Panel Boards, Switch Gears, Earthings And Connected Misc Works Etc At Electric Supply Installation At installation Dronacharya Under Ge Fort Kochi

BOQ

Name of Work:- REPAIR/ MAINT OF LT PANEL BOARDS, SWITCH GEARS, EARTHINGS AND CONNECTED MISC WORKS ETC AT ELECTRIC SUPPLY INSTALLATION AT INS DRONACHARYA UNDER GE FORT KOCHI
Sl. No. Item Description
1Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and making good bottom surface for laying /removing of cable, erection of poles in soft/ loose soil complete, all as specified and as directed.
2Material and Labour for removing excavated soil to a distance not exceeding 50 m and not exceeding 1.5 m above the starting point, and depositing where directed complete all as specified and as directed.
3Material and Labour for sand cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the Cable) and consolidated (punned) up to 180mm thickness, complete all as specified and as directed. Note: For the purpose of payment, punned thickness of Sand Cushioning only will be measured.
4Material and labour for burnt bricks subclass B laid in trenches for cable protection complete, all as specified and as directed.
5Returning filling in excavated soil in trenches, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
6Taking out unserviceable UG cables of any sizes from trenches/walls including all mounting accessories and GI tubing including making good to disturbed area complete all as specified and as directed
7Material and Labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 16 sqmm 4 core, 1100-volt grade, Earthed, Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc. with stranded aluminium conductor of size laid in trenches, ducts etc. complete all as specified and as directed.
8Material and Labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 25 sqmm 4 core, 1100-volt grade, Earthed, Heavy grade conforming to IS :7098 (Part 2) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc. complete all as specified and as directed.
9Material and Labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 50 sqmm 3.5 core, 1100-volt grade, Earthed, Heavy grade conforming to IS :7098 (Part 4) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc. complete all as specified and as directed.
10Material and Labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 70 sqmm 3.5 core, 1100-volt grade, Earthed, Heavy grade conforming to IS :7098 (Part 5) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc. complete all as specified and as directed.
11Taking down unserviceable LT panel of any type from existing position after disconnection of electric connection of all any size UG cables & temporary restoration of normal electric supply till final installation of New LT panel including making good disturbed surfaces if floor/walls etc complete all as specified and as directed.
12Supply, installation, commissioning and testing LT Panel Board of minimum size 2.0 Mtr (height) x 2.0 Mtr (breath) x 0.45m (depth) ,2.0 mm thick, factory made CPRI approved panel, weather, dust & vermin proof Indoor type, double door, front openable, and made LT panel through Stainless steel sheet compartmentalized design including stainless steel channel frame, and ISMC 75 at the base of panel only for grouted with PCC using 20 mm graded stone aggregate, duly providing rubber/ PVC gasket of suitable size all sides of door, with aluminium busbar 800 AMPs capacity wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB output of suitable length including aluminium bus bar of suitable size for neutral for connection of cable from main busbar, made out of 2.0 mm thick stainless steel with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 6 sqmm copper wire and connections of all outgoing/ incoming electrical cable connections with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm angering with 45 cm height from ground level at the base of panel. The panel shall be comprising of following accessories, complete all as specified and as directed.
13INCOMMING: -(a) MCCB, 4 Pole 415 Volts, 50Hz 250 Amps, 36 kA, thermal magnetic release, Ics =100% Icu, front face isolation with positive break indication with double break contacts with spreader and phase barrier - 01 No, Make - L/T, Havells, Schneider.(b) Multi-function digital energy meter with Rs 485 communication port with CTs.(c) Phase Indicator lamp assy RYB - 01 Set.(d) CT Coils of suitable ratio-01 Set. OUTGOING: - (a) MCCB, 4 Pole 415 Volts, 50Hz, 160 Amps, 25 kA, thermal magnetic release, Ics =100% Icu, front face isolation with positive break indication with double break contacts with spreader and phase barrier - 03 Each.(b) MCCB, 4 Pole 415 Volts, 50Hz, 100 Amps, 25 kA, thermal magnetic release, Ics =100% Icu, front face isolation with positive break indication with double break contacts with spreader and phase barrier - 02 Each.(c) MCCB, 4 Pole 415 Volts, 50Hz, 63 Amps, 25 kA, thermal magnetic release, Ics =100% Icu, front face isolation with positive break indication with double break contacts with spreader and phase barrier - 02 Each.(d) MCB, single pole & neutral, up to 32 Amps, with DBs, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed -0 2 Nos.(e) Automatic single dial time switch panel mounted flush to panel door, 230V AC quartz time base, with one selector switch for auto/manual selection Part No 15336, Type IH24h Make- Schneider/L&T/Legrand – 01 No (Bldg Security light)
14Supply, installation, commissioning and testing LT Panel Board of minimum size 1.0Mtr (height) x 1.0 Mtr (breath) x 0.45 m (depth) ,2.0 mm thick, factory made CPRI approved panel, weather, dust & vermin proof Indoor type, double door, front openable, and made LT panel through Stainless steel sheet compartmentalized design including stainless steel channel frame, and ISMC 75 at the base of panel only for grouted with PCC using 20 mm graded stone aggregate, duly providing rubber/ PVC gasket of suitable size all sides of door, with aluminium busbar 200 AMPs capacity wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB output of suitable length including aluminium bus bar of suitable size for neutral for connection of cable from main busbar, made out of2.0mm thick stainless steel with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 6 sqmm copper wire and connections of all outgoing / incoming electrical cable connections with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm angering with 45 CM height from ground level at the base of panel . The panel shall be comprising of following accessories, complete all as specified and as directed by Engineer-in-Charge.
151. Two (02) Nos of 10 HP (7.5 KW) capacity star delta starter fixing with is a three-phase motor control device designed to reduce starting current by initially running the motor in a star configuration before automatically switching to a delta configuration for full load operation. 2. Power rating 10 HP (7.5 KW), operational voltage 415 V, AC, three phase, frequency 50 Hz.3. Over load relay range: Typically, 6 A - 10A or 9 A-14 A depending on motor full load current specifies.4. Control / coil voltage: 415 V AC.5. Utilization category: AC 3 duty for induction motors.6. Contactors: Three inter connected 3 pole contactors, main star and delta, engineered with mechanical and Electrical interlocking to prevent simultaneous star - delta closure.7. Timer: Integrated electric or pneumatic timer that automatically shifts the connection from star mode to delta mode after a preset duration.8. Thermal overload protection: Protects the motor against continuous current overload and burning.9. Single phasing protector: Trips the system instantly / imbalance protector: Prevents reverse rotation and unbalance voltage stress on motor windings.
16INCOMMING: -(a) MCCB, 4 Pole 415 Volts, 50Hz, 63 Amps, 16 kA, thermal magnetic release, Ics =100% Icu, front face isolation with positive break indication with double break contacts with spreader and phase barrier - 01 Each.(b) Multi-function digital energy meter with Rs 485 communication port with CTs.(c) Phase Indicator lamp assy RYB - 01 Set.(d) CT Coils of suitable ratio-01 Set. OUTGOING: - (a) MCB, TP, 63 Amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed - 02 Nos
17Earthing complete with galvanised iron earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, earth plate connected with GI strip 32X 6 mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel, GI protection pipe 40 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connected to earthing test point all as specified or indicated including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around copper earth plate, GI pipe medium grade 20 mm nominal bore watering pipe, GI sheet funnel, wire mesh, PCC pit 1:2:4, (type B-1) RCC cover 50 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 8 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit/ chamber in PCC 1:2:4 (type B-1) including testing on completion complete all as specified and as directed.
18Material and Labour for servicing of LT Panel boards outdoor/indoor of sizes up to 250 x 150 x 50 cm installed at various locations by disconnecting from mains taking out burnt cable ends and reconnecting using internal connection with copper cables, necessary lugs, cable glands, gland plate, gaskets etc and scrapping out of rusted uneven surfaces and applying by spray painting two coats of paint of desired shade over a coat of metallic primer complete all as specified and as directed.
19Material and Labour for servicing of LT Feeder pillars outdoor/indoor of sizes up to 200 x 100 x 40 cm installed at various locations by disconnecting from mains taking out burnt cable ends and reconnecting internal connection with copper cables using necessary lugs, cable glands, gland plate, gaskets etc and scrapping out of rusted uneven surfaces and applying by spray painting two coats of paint of desired shade over a coat of metallic primer complete all as specified and as directed.
20Supply and laying GI tubing light grade including all accessories for encasing cables for mechanical protection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/sockets/reducers/saddles and necessary threading/drilling works complete including taking down old tubing all as specified and as directed of sizes:
2180 mm bore
2250 mm bore
2340 mm bore
24Supply and fix in replacement MCCB 415V 160 Amps TPN 25 KA thermal magnetic release with spreader terminals and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish including taking down old unserviceable MCCB complete all as specified and as directed.
25Supply and fix in replacement MCCB 415V 200 Amps TPN 36 KA thermal magnetic release with spreader terminals and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish including taking down old unserviceable MCCB complete all as specified and as directed.
26Supply and fix in replacement MCCB 415V 250 Amps TPN 36 KA microprocessor-based release with spreader terminals and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish including taking down old unserviceable MCCB complete all as specified and as directed.
27Supply and fix in replacement MCCB 415V 125 Amps TPN 25 KA microprocessor-based release with spreader terminals and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish including taking down old unserviceable MCCB complete all as specified and as directed.
28Supply and fix in replacement MCCB 415V 63 Amps TPN 25 KA microprocessor-based release with spreader terminals and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish including taking down old unserviceable MCCB complete all as specified and as directed.
29Supply and fix in replacement MCCB 415V 400 Amps TPN 26 KA microprocessor-based release with spreader terminals and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish including taking down old unserviceable MCCB complete all as specified and as directed.
30Material and Labour for clearing of Grass Shrubs and other growing by uprooting around poles and feeder pillars up to 10 cm in girth in various locations complete all as specified and as directed
31Material and Labour for GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit and including taking down old unserviceable materials complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58096380
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13.75 Lakhs
LAST DATE 06-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Lt Panel Boards, Switch Gears, Earthings And Connected Misc Works Etc At Electric Supply Installation At installation Dronacharya Under Ge Fort Kochi
Basic Detail
Tender No 8434/E8_GE_FORT_KOCHI
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 16 Oct 2026
Submission Date 06 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 13.75 Lakhs
Tender Fee 500
EMD 27500
Exemption Available
Document List
781fb34e-47fb-4965-9220-0ad3351c43be.html
8434Tenderdocu.pdf
BOQ_890802.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

781fb34e-47fb-4965-9220-0ad3351c43be.html

pdf

8434Tenderdocu.pdf

xls

BOQ_890802.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender