Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58096361

Tender For Repair And Maintenance Of Bus Bar Panel, Lt Panel, Acbs, Mccbs And Connected Items At Tigris, Tea Point Circle, Engr Mess, Arty Mess, Old Location 61 Cavalry, Cmp Unit, 972 Tpt Coy, 333 Fd Regt, Gun Shed, Mech C , Signal Coy, Hb Stadium,19

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
48 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
18 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Bus Bar Panel, Lt Panel, Acbs, Mccbs And Connected Items At Tigris, Tea Point Circle, Engr Mess, Arty Mess, Old Location 61 Cavalry, Cmp Unit, 972 Tpt Coy, 333 Fd Regt, Gun Shed, Mech C , Signal Coy, Hb Stadium,19 Haa, Hq Delhi Area, Did Line, Did Line Swimming Pool, Poultry Farm No 4, Maude Road And Adjoining Area Of Age Elect Supply Sldc Under Ge (U) Elect Supply Delhi Cantt-10

BOQ

Name of Work:- REPAIR AND MAINT OF BUS BAR PANEL, LT PANEL, ACBS, MCCBS AND CONNECTED ITEMS AT TIGRIS, TEA POINT CIRCLE, ENGR MESS, ARTY MESS, OLD LOCATION 61 CAVALRY, CMP UNIT, 972 TPT COY, 333 FD REGT, GUN SHED, MECH C , SIGNAL COY, HB STADIUM,19 HAA, HQ DELHI AREA, DID LINE, DID LINE SWIMMING POOL, POULTRY FARM NO 4, MAUDE ROAD AND ADJOINING AREA OF AGE ELECT SUPPLY SLDC UNDER GE (U) ELECT SUPPLY DELHI CANTT-10
Sl. No. Item Description
1Dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/LT panel boards etc and supply and fixing new cold rolled medium weight mild steel hinges and door handles in position as per existing requirement with necessary spot welding, screwing etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed by Engr in Charge.
2Material & Labour for replacement of existing unserviceable/damaged part/portion of the existing feeder pillar box/ panel boards with supply and fixing new part or portion fabricated out of 2 mm thick MS sheet in position including making necessary adjustments and alignments to make the existing feeder pillar box/panel board body to required shape and size(s) complete all as specified and directed by Engr in Charge.Note :- (a) The panel board repaired shall be made totally enclosed, weather proof for installing incoming/out going MCCB/switch fuses/ cable etc. complete all as directed.(b) The work is required to be executed in patch works and the rates quoted by the contractor are deemed to be with and including necessary cutting, welding, leveling, jointing and providing gasket for weather proof etc. as directed to match & accommodate with the existing feeder pillar box / panel board enclosures.(c) The replaced portion shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer with necessary filler coating.
3Disconnecting and taking out old existing unserviceable voltmeter of any description and in any position and supply, fixing, connecting, testing and commissioning of 3 phase digital electronic voltmeter class I, any range matching with in built selector switch, suitable for LT 415 Volts 50 Hz AC supply, flush pattern, square type, with adopter complete all as specified and directed by Engr in Charge.
4Disconnecting and taking out old existing unserviceable Ammeter of any description and in any position and supply, fixing, connecting, testing and commissioning of 3 phase digital electronic Ammeter class I, any range suitable for matching with existing CT ratio and in built selector switch suitable for LT 415 Volts 50Hz AC supply flush pattern, square type, 96mm x 96 mm with adopter complete all as specified and directed by Engr in Charge.
5Disconnecting and taking out old existing unserviceable Phase indication lamps and supply, fixing, connecting and, testing of LED type Phase indication lamp with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using suitable size copper cables wires and lugs complete all as specified and directed by Engr in Charge.
6M & L for preparation of old steel surfaces of steel/LT panel boards/feeder pillar boxes of any description & any position including removing disintegrated/detoriating part of paint and applying filler coat to obtain smooth surfaces and applying a coat of synthetic enamel paint using spray machine to obtain smooth finish complete all as specified and directed by Engr in Charge.
7Supply & fixing MCCB 415V AC, 4 pole should have reverse load and line termination, For 32-100 A:Should have breaking capacity of min.16 KA with thermal release adjustable from 80 to 100% & fixed magnetic release with Ics=Icu=100% For 100-160 A:Should have breaking capacity of min.25 KA with thermal release adjustable from 80 to 100% & fixed magnetic release with Ics=Icu=100% For 200-315 A:should have breaking capacity of min.25 KA with thermal release adjustable from 80 to 100 % and magnetic release adjustable from 5 to 10 In with Ics=Icu=100% . For 400-630 A:should have breaking capacity of 36 KA and thermal release adjustable from 80 to 100% and magnetic release adjustable from 5 to 10 In with Ics=Icu=100% with adjustable overload and adjustable short circuit protection in existing LT panel/provn of fixing arrangements by cutting and drilling busbar to exact size/provision of copper leads of suitable size at site to fix MCCB in existing panel including provision of thimbles and nut bolts of proper size and having following cap:-
8(a) MCCB 630 Amp 4 pole.
9(b) MCCB 400 Amp 4 pole.
10(c) MCCB 250 Amp 4 pole.
11(d) MCCB 200 Amp 4 pole.
12(e) MCCB 160 Amp 4 pole.
13(f) MCCB 100 Amp 4 pole.
14Material & Labour for cleaning of substations, removing of stones, mud, or any other type of material from the sub station including removing of bushes and throwing them out from cantt area complete all as specified and directed by Engr in Charge.
15Material & Labour for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate in wall or retaining walls, any thickness, size or shape including plaster, buttresses columns, pillars and posts including caps and bases complete all as specified and directed by Engr in Charge.
16Supply and Fixing of ACB as given below, fixed type, shall confirm to IEC 60947 /IS 13947 (Part 1 & 2). The minimum breaking capacity should be 50KA. The service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity (Icu) and short time with stand capacity (Icw) with ICS =Icu=Icw. The Icw value is for 1sec. The ACB shall have microprocessor based protection units with flexible and adjustable current - time protection settings for overload, short circuit, instantaneous short circuit and Earth Fault Protections. ACB should be suitable for a 3 phase service voltage, up to 690V for 50/60 Hz AC supply and shall have an insulation voltage of 1000V. All the protection units should have built in Dedicated inbuilt LEDs for fault indication for overload, short circuit and Earth Fault complete all as specified and directed by Engr in Charge.
17(a) ACB 800 Amp 4 pole.
18(b) ACB 1000 Amp 4 pole.
19Supply and Fixing of Junction box thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65 (weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands (IP-65) and/or grommets (IP-55). Size of enclosure: (205x255 x112) mm with suitable connecters for 2Ph/1Ph loop in loop out and branch out vibration proof connections complete all as specified and directed by Engr in Charge.
20Supply and fixing aluminium lugs of size 1000/800 Sqmm complete all as specified and directed by Engr in Charge.
21Supply and fixing aluminium lugs of size 630 Sqmm complete all as specified and directed by Engr in Charge.
22Supply and fixing aluminium lugs of size 400 Sqmm complete all as specified and directed by Engr in Charge.
23Supply and fixing aluminium lugs of size 300 sqmm complete all as specified and directed by Engr in Charge.
24Supply and fixing aluminium lugs of size 185 Sqmm complete all as specified and directed by Engr in Charge.
25Supply and fixing aluminium lugs of size 120 Sqmm complete all as specified and directed by Engr in Charge.
26Supply and fixing aluminium lugs of size 95 Sqmm complete all as specified and directed by Engr in Charge.
27Supply and fixing aluminium lugs of size 70 sqmm complete all as specified and directed by Engr in Charge.
28Supply and fixing aluminium lugs of size 50 sqmm complete all as specified and directed by Engr in Charge.
29Supply and fixing aluminium lugs of size 35 sqmm complete all as specified and directed by Engr in Charge.
30Dismantling and M&L for Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal Red colour and inclusive fixed with MS flat clamps 25x3mm 2 Nos, nuts, bolts for LT 440 volt of size 20x15cm complete all as specified and directed by Engr in Charge.
31Supply and fixing of (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 06 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engr in Charge.
32Supply and fixing of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 10 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engr in Charge.
33Supply and fixing of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 2.5 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engr in Charge.
34S&F of service connection with PVC insulated and PVC sheathed flat twin core cable 1100V grade heavy duty electric cable served all PVC sheathed in service connections suspended with suspension wire and loop insulators of size 06 Sqmm cross sectional area stranded aluminium conductor complete all as specified and directed by Engr in Charge.
35M&L for painting to transformer guard (XPM), fencing channels mounted on plinth to all steel parts of approx 30 to 50 sqm with silver aluminium paint one coat complete all as specified and directed by Engr in Charge.
36Supply and fixing of LED Flood lights 50 Watt made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engr in Charge.
37Supplying and installation of 3 Pole power contactor, type MNX 110 having 2 NO +2 NC contacts. Make :- L&T Cat part no CS94137 or equivalent in Havells/Schnider as approved by GE.
38Supplying and installation of Analog Time switch, 240 Volt AC, 50 Hz - 01 No. Make : L&T Cat No J648B1 or equivalent in Havells/Schnider as approved by GE.
39S&F of 3.5m long post top light pole aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish, plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to the pole complete all as specified and directed by Engr in Charge.
40S&F of 35 W post top lantern having protection IP 65/66 complete all as specified and directed by Engr in Charge. Please Enable Macros to View BoQ information
41S&F of 35 W post top lantern having protection IP 65/66 complete all as specified and directed by Engr in Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58096361
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48 Lakhs
LAST DATE 06-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Bus Bar Panel, Lt Panel, Acbs, Mccbs And Connected Items At Tigris, Tea Point Circle, Engr Mess, Arty Mess, Old Location 61 Cavalry, Cmp Unit, 972 Tpt Coy, 333 Fd Regt, Gun Shed, Mech C , Signal Coy, Hb Stadium,19 Haa, Hq Delhi Area, Did Line, Did Line Swimming Pool, Poultry Farm No 4, Maude Road And Adjoining Area Of Age Elect Supply Sldc Under Ge (U) Elect Supply Delhi Cantt-10
Basic Detail
Tender No GE ELECT/TOKEN-48/2026-2027
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 16 Oct 2026
Submission Date 06 Nov 2026
Open Date 09 Nov 2026
Finance
Tender Value 48 Lakhs
Tender Fee 500
EMD 96000
Exemption Not Available
Document List
BOQ_890876.xls
cc13adcd-92a2-49a5-a72a-04e8f9bb6c29.html
TD48.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_890876.xls

html

cc13adcd-92a2-49a5-a72a-04e8f9bb6c29.html

pdf

TD48.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender